{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T16:10:04Z","timestamp":1749917404031,"version":"3.41.0"},"reference-count":16,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T00:00:00Z","timestamp":1707782400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T00:00:00Z","timestamp":1707782400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective.<\/jats:italic> In this feasibility study, we explore an application of a Resistive Electrode Array (REA) for localization of a radioactive point source. The inverse problem posed by multichannel REA detection is studied from mathematical perspective and involves the questions of the minimal configuration of the conductive leads that can achieve this goal. The basic configuration consists of a circularly shaped REA with four opposite electrical lead\u2013pairs at its perimeter. <jats:italic>Approach.<\/jats:italic> A robust mathematical reconstruction method for a 3D radioactive source relative to the REA is presented. The characteristic empirical Green\u2019s function for the detector response of the REA is determined by numerically solving Laplace equations with appropriate boundary conditions. Based on this model, Monte Carlo simulations of the inverse problem with Gaussian noise are performed and the overall accuracy of the localization is investigated. <jats:italic>Main results.<\/jats:italic>  The results show a 3D error distribution of localization which is uniform in the (<jats:italic>x<\/jats:italic>, <jats:italic>y<\/jats:italic>)\u2013plane of the REA and strongly correlated in the orthogonal <jats:italic>z<\/jats:italic>\u2013axis. The overall accuracy decreases with higher distance of the source to the detector which is intuitive due to approximate flux dependence following the inverse square law. Further, a saturation in accuracy regarding the number of electrical leads and a linear dependence of the reconstruction error on the measurement noise level are observed. <jats:italic>Significance.<\/jats:italic> A broad range of REA detector configurations and their characteristics are investigated by this study for radioactive source localization allowing diverse practical applications with detector diameters ranging from millimeters to meters.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad25bd","type":"journal-article","created":{"date-parts":[[2024,2,2]],"date-time":"2024-02-02T23:04:15Z","timestamp":1706915055000},"page":"025027","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Radioactive source localization employing resistive electrode array (REA) detector"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5303-9334","authenticated-orcid":true,"given":"Wolfgang","family":"Hoegele","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4903-5306","authenticated-orcid":false,"given":"Victoria","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-2136-1442","authenticated-orcid":false,"given":"Elena","family":"Grace Vasquez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-8403-3486","authenticated-orcid":false,"given":"Indre","family":"Gineitaite","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6802-0014","authenticated-orcid":true,"given":"Erno","family":"Sajo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4127-9955","authenticated-orcid":true,"given":"Davide","family":"Brivio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6122-0600","authenticated-orcid":false,"given":"Piotr","family":"Zygmanski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,2,13]]},"reference":[{"key":"bpexad25bdbib1","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1088\/1361-6560\/ac762b","article-title":"Resistive electrode array (REA) for radiotherapy beam monitoring and quality assurance","volume":"24","author":"Zygmanski","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"bpexad25bdbib2","doi-asserted-by":"publisher","first-page":"4454","DOI":"10.1120\/jacmp.v15i2.4454","article-title":"Low-cost flexible thin-film detector for medical dosimetry applications","volume":"06","author":"Zygmanski","year":"2014","journal-title":"J .Appl. Clin. Med. Phys."},{"key":"bpexad25bdbib3","doi-asserted-by":"publisher","first-page":"4027","DOI":"10.1118\/1.4922202","article-title":"Technical Note: Nanometric organic photovoltaic thin film detectors for dose monitoring in diagnostic x-ray imaging","volume":"42","author":"Elshahat","year":"2015","journal-title":"Med. Phys."},{"key":"bpexad25bdbib4","doi-asserted-by":"publisher","first-page":"N121","DOI":"10.1088\/0031-9155\/60\/7\/N121","article-title":"Dosimetric properties of high energy current (HEC) detector in keV x-ray beams","volume":"60","author":"Zygmanski","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"bpexad25bdbib5","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1118\/1.598232","article-title":"High dose-rate brachytherapy treatment delivery: report of the AAPM Radiation Therapy Committee Task Group No. 59","volume":"25","author":"Kubo","year":"1998","journal-title":"Med. Phys."},{"key":"bpexad25bdbib6","doi-asserted-by":"publisher","first-page":"1921","DOI":"10.1002\/mp.14717","article-title":"Self-powered multilayer radioisotope identification device","volume":"48","author":"Brivio","year":"2021","journal-title":"Med. Phys."},{"key":"bpexad25bdbib7","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1088\/1748-0221\/17\/07\/T07001","article-title":"Real-time tracking of source movement by Cherenkov emission imaging for high-dose-rate brachytherapy","author":"Yogo","year":"2022","journal-title":"J. Instrum."},{"key":"bpexad25bdbib8","doi-asserted-by":"publisher","DOI":"10.1118\/1.4823758","article-title":"Source position verification and dosimetry in HDR brachytherapy using an EPID","volume":"40","author":"Smith","year":"2013","journal-title":"Med. Phys."},{"key":"bpexad25bdbib9","doi-asserted-by":"publisher","first-page":"1432","DOI":"10.3390\/jpm12091432","article-title":"Personalized superficial hdr brachytherapy-dosimetric verification of dose distribution with lead shielding of critical organs in the head and neck region","volume":"12","author":"Zwierzchowski","year":"2022","journal-title":"J. Pers. Med."},{"key":"bpexad25bdbib10","doi-asserted-by":"publisher","DOI":"10.1118\/1.4794487","article-title":"BrachyView: proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy","volume":"40","author":"Petasecca","year":"2013","journal-title":"Med. Phys."},{"key":"bpexad25bdbib11","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/17\/03\/C03018","article-title":"Radioactive source localization using a data driven MVA method","volume":"17","author":"Kyriakis","year":"2022","journal-title":"J. Instrum."},{"key":"bpexad25bdbib12","doi-asserted-by":"publisher","first-page":"9198","DOI":"10.3390\/s22239198","article-title":"Real-Time Gamma Radioactive Source Localization by Data Fusion of 3D-LiDAR Terrain Scan and Radiation Data from Semi-Autonomous UAV Flights","volume":"22","author":"Schraml","year":"2022","journal-title":"Sensors (Basel)."},{"key":"bpexad25bdbib13","doi-asserted-by":"publisher","first-page":"5490","DOI":"10.1002\/mp.14483","article-title":"Technical Note: Scintillation markers for real-time visual source tracking during skin high dose rate brachytherapy","volume":"47","author":"Huynh","year":"2020","journal-title":"Med. Phys."},{"key":"bpexad25bdbib14","doi-asserted-by":"publisher","first-page":"807","DOI":"10.3390\/s21030807","article-title":"Radioactive Source Localisation via Projective Linear Reconstruction","volume":"21","author":"White","year":"2021","journal-title":"Sensors (Basel)."},{"key":"bpexad25bdbib15","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1118\/1.1646040","article-title":"Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations","volume":"31","author":"Rivard","year":"2004","journal-title":"Med. Phys."},{"key":"bpexad25bdbib16","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1118\/1.1646040","article-title":"Update of AAPM Task Group No. 43 Report: a revised AAPM protocol for brachytherapy dose calculations","volume":"31","author":"Rivard","year":"2004","journal-title":"Med. Phys."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad25bd","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad25bd\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad25bd","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad25bd\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad25bd\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad25bd\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad25bd\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad25bd\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T15:33:34Z","timestamp":1749915214000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad25bd"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,13]]},"references-count":16,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,2,13]]},"published-print":{"date-parts":[[2024,3,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad25bd","relation":{},"ISSN":["2057-1976"],"issn-type":[{"type":"electronic","value":"2057-1976"}],"subject":[],"published":{"date-parts":[[2024,2,13]]},"assertion":[{"value":"Radioactive source localization employing resistive electrode array (REA) detector","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-10-11","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-02","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-13","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}