{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T10:20:18Z","timestamp":1781259618809,"version":"3.54.1"},"reference-count":47,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2024,2,22]],"date-time":"2024-02-22T00:00:00Z","timestamp":1708560000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,2,22]],"date-time":"2024-02-22T00:00:00Z","timestamp":1708560000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Traumatic dental injuries can occur due to various reasons such as accidents, sports injuries, fights, falls, and others. These injuries can affect the teeth, gums, and surrounding tissues, and can range from minor chips and cracks to severe fractures, dislocations, and avulsions (when the tooth is completely knocked out of the socket). The most common way to address this is by replacing affected teeth with dental implants. The purpose of this research is to evaluate the use of composite materials in dental implants and compare them with the traditionally used materials using a patient specific cone beam computed tomography (CBCT) based finite element model (FEM). To conduct this research, two different implant groups i.e., traditional implant and composite implant were designed using Titanium grade 4, zirconium oxide-reinforced lithium silicate (ZLS), and Zirconia (ZrO<jats:sub>2<\/jats:sub>). Six dental implants were designed namely Ti implant, ZLS implant, ZrO<jats:sub>2<\/jats:sub> implant, Ti-ZrO<jats:sub>2<\/jats:sub> composite, Ti-ZLS composite, and ZLS-ZrO<jats:sub>2<\/jats:sub> composite using 3D modelling software. Detailed full-scale 3D models of patient specific dental implant were developed and traumatic loading conditions were applied to the enamel of central incisor teeth or crown of dental implant, and maxilla was constrained in all directions. It was found that the use of composite materials for dental implants can reduce the stresses over the surface of abutment and implant as compared to traditional implants. The detailed models developed as a part of this study can advance the research on dental implants, and with further experimental validation allow the use of composite materials for fabrication of more stable dental implants.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad28ce","type":"journal-article","created":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T22:21:42Z","timestamp":1707862902000},"page":"025035","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Development of patient-specific finite element model for study of composite dental implants"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9276-3854","authenticated-orcid":true,"given":"Vivek","family":"Gupta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anshika","family":"Garg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6747-5110","authenticated-orcid":true,"given":"Nitesh","family":"Tewari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sukeshana","family":"Srivastav","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6266-078X","authenticated-orcid":true,"given":"Arnab","family":"Chanda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,2,22]]},"reference":[{"key":"bpexad28cebib1","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1111\/edt.12389","article-title":"World traumatic dental injury prevalence and incidence, a meta-analysis\u2014One billion living people have had traumatic dental injuries","volume":"34","author":"Petti","year":"2018","journal-title":"Dent. Traumatol."},{"key":"bpexad28cebib2","doi-asserted-by":"publisher","first-page":"601","DOI":"10.4103\/ijdr.IJDR_953_19","article-title":"Prevalence of traumatic dental injuries in India: a systematic review and meta-analysis","volume":"31","author":"Tewari","year":"2020","journal-title":"Indian J. Dent. Res."},{"key":"bpexad28cebib3","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1111\/edt.12481","article-title":"The association of overjet size and traumatic dental injuries\u2014a systematic review and meta-analysis","volume":"35","author":"Arraj","year":"2019","journal-title":"Dent. Traumatol."},{"key":"bpexad28cebib4","doi-asserted-by":"publisher","first-page":"41","DOI":"10.3390\/mca28020041","article-title":"Effect of adhesive materials in re-attachment of crown and crown\u2013root fractures of permanent maxillary anterior tooth: a computational study","volume":"28","author":"Garg","year":"2023","journal-title":"Math Comput. Appl."},{"key":"bpexad28cebib5","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1007\/s40496-018-0196-9","article-title":"Tooth repair and regeneration","volume":"5","author":"Angelova Volponi","year":"2018","journal-title":"Curr. Oral. Heal Reports"},{"key":"bpexad28cebib6","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1902\/jop.2002.73.7.687","article-title":"The single-tooth implant: a viable alternative for single-tooth replacement","volume":"73","author":"Mayer","year":"2002","journal-title":"J. Periodontol."},{"key":"bpexad28cebib7","doi-asserted-by":"publisher","first-page":"100","DOI":"10.3390\/prosthesis2020011","article-title":"Titanium alloys for dental implants: a review","volume":"2","author":"Nicholson","year":"2020","journal-title":"Prosthesis"},{"key":"bpexad28cebib8","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.prosdent.2004.08.003","article-title":"A review of selected dental literature on evidence-based treatment planning for dental implants: report of the committee on research in fixed prosthodontics of the academy of fixed prosthodontics","volume":"92","author":"Wood","year":"2004","journal-title":"J. Prosthet Dent."},{"key":"bpexad28cebib9","doi-asserted-by":"publisher","DOI":"10.1088\/978-0-7503-3671-0","article-title":"Nanotechnology in dental implants","author":"Chatterjee","year":"2021"},{"key":"bpexad28cebib10","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/978-981-19-7935-4_3","article-title":"Cold plasma in dentistry","volume":"148","author":"Kwon","year":"2023","journal-title":"Top. Appl. Phys."},{"key":"bpexad28cebib11","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1111\/prd.12416","article-title":"Prosthetic failures in dental implant therapy","volume":"88","author":"Sailer","year":"2022","journal-title":"Periodontol 2000"},{"key":"bpexad28cebib12","doi-asserted-by":"publisher","first-page":"79","DOI":"10.3390\/computation11040079","article-title":"Computational investigation of dental implant restoration using platform-switched and -matched configurations","volume":"11","author":"Afazal","year":"2023","journal-title":"Comput"},{"key":"bpexad28cebib13","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1002\/9781119800613.ch10","article-title":"Clinical applications of digital dental technology in implant prosthodontics","author":"Choi","year":"2023"},{"key":"bpexad28cebib14","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1039\/D1MH01621K","article-title":"Three interfaces of the dental implant system and their clinical effects on hard and soft tissues","volume":"9","author":"Kim","year":"2022","journal-title":"Mater Horizons"},{"key":"bpexad28cebib15","doi-asserted-by":"publisher","first-page":"301","DOI":"10.4103\/ccd.ccd_196_20","article-title":"Biomimetic properties of engineered periodontal ligament\/cementum in dental implants","volume":"11","author":"Mathew","year":"2020","journal-title":"Contemp Clin. Dent."},{"key":"bpexad28cebib16","doi-asserted-by":"publisher","first-page":"167","DOI":"10.4103\/0972-4052.167937","article-title":"Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study","volume":"16","author":"Selvaraj","year":"2016","journal-title":"J. Indian Prosthodont Soc."},{"key":"bpexad28cebib17","doi-asserted-by":"publisher","first-page":"84","DOI":"10.4103\/jdi.jdi_14_20","article-title":"A comparative study to evaluate the retention of conventional retention sleeve material versus retention.sil 600 in implant-retained overdentures: In vitro study","volume":"10","author":"Khan","year":"2020","journal-title":"J. Dent. Implant."},{"key":"bpexad28cebib18","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1016\/j.dental.2013.04.010","article-title":"Validation of finite element models for strain analysis of implant-supported prostheses using digital image correlation","volume":"29","author":"Tiossi","year":"2013","journal-title":"Dent. Mater."},{"key":"bpexad28cebib19","author":"Straumann","year":"2023"},{"key":"bpexad28cebib20","author":"BioHorizons","year":"2023"},{"key":"bpexad28cebib21","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.jmbbm.2019.02.025","article-title":"Fretting-corrosion behavior on dental implant connection in human saliva","volume":"94","author":"Corne","year":"2019","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"bpexad28cebib22","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1111\/cid.12742","article-title":"On osseointegration in relation to implant surfaces","volume":"21","author":"Albrektsson","year":"2019","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"bpexad28cebib23","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1111\/cid.12706","article-title":"PEEK materials as an alternative to titanium in dental implants: a systematic review","volume":"21","author":"Mishra","year":"2019","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"bpexad28cebib24","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1111\/jopr.13415","article-title":"Fracture resistance of single-unit implant-supported crowns: effects of prosthetic design and restorative material","volume":"31","author":"Donmez","year":"2022","journal-title":"J. Prosthodont"},{"key":"bpexad28cebib25","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1111\/cid.12894","article-title":"Comparison of strains for new generation CAD-CAM implant-supported crowns under loading","volume":"22","author":"Yilmaz","year":"2020","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"bpexad28cebib26","doi-asserted-by":"publisher","first-page":"4956","DOI":"10.1016\/j.jmrt.2019.06.043","article-title":"Zirconia in dental prosthetics: a literature review","volume":"8","author":"Grech","year":"2019","journal-title":"J. Mater Res. Technol."},{"key":"bpexad28cebib27","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.actbio.2018.03.007","article-title":"In vitro and in vivo studies on zinc-hydroxyapatite composites as novel biodegradable metal matrix composite for orthopedic applications","volume":"71","author":"Yang","year":"2018","journal-title":"Acta Biomater."},{"key":"bpexad28cebib28","doi-asserted-by":"crossref","first-page":"M550","DOI":"10.1097\/00002480-199207000-00095","article-title":"Performance of a hydrogel composite pericardial substitute after long-term implant studies","volume":"38","author":"Walker","year":"1992","journal-title":"ASAIO J"},{"key":"bpexad28cebib29","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ac669c","article-title":"Finite element analysis of a hybrid corrugated hip implant for stability and loading during gait phases","volume":"8","author":"Gupta","year":"2022","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexad28cebib30","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1615\/JLongTermEffMedImplants.v15.i6.70","article-title":"Composite resin in medicine and dentistry","volume":"15","author":"Stein","year":"2005","journal-title":"J. Long. Term. Eff. Med. Implants"},{"key":"bpexad28cebib31","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1016\/j.prosdent.2016.04.004","article-title":"Influence of implant abutment material on the color of different ceramic crown systems","volume":"116","author":"Dede","year":"2016","journal-title":"J. Prosthet. Dent."},{"key":"bpexad28cebib32","doi-asserted-by":"publisher","first-page":"5376","DOI":"10.3390\/app10155376","article-title":"Bioactive healing abutment as a potential tool for the treatment of peri-implant disease-in vitro study","volume":"10","author":"Iwa\u0144czyk","year":"2020","journal-title":"Appl. Sci."},{"key":"bpexad28cebib33","author":"Adin Implants","year":"2023"},{"key":"bpexad28cebib34","first-page":"239","article-title":"Comparison of the effect of implant abutment surface modifications on retention of implant-supported restoration with a polymer based cement","volume":"8","author":"Sahu","year":"2014","journal-title":"J. Clin. Diagnostic Res."},{"key":"bpexad28cebib35","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.jdent.2005.06.007","article-title":"Damping effects on the response of maxillary incisor subjected to a traumatic impact force: A nonlinear finite element analysis","volume":"34","author":"Huang","year":"2006","journal-title":"J. Dent."},{"key":"bpexad28cebib36","doi-asserted-by":"publisher","DOI":"10.1016\/j.matdes.2020.108540","article-title":"3D printing of calcium phosphate scaffolds with controlled release of antibacterial functions for jaw bone repair","volume":"189","author":"Sun","year":"2020","journal-title":"Mater. Des."},{"key":"bpexad28cebib37","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jmbbm.2011.10.002","article-title":"Dynamic and static mechanical analysis of resin luting cements","volume":"6","author":"Tolidis","year":"2012","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"bpexad28cebib38","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/S0921-5093(97)00806-X","article-title":"Mechanical properties of biomedical titanium alloys","volume":"243","author":"Niinomi","year":"1998","journal-title":"Mater. Sci. Eng. A"},{"key":"bpexad28cebib39","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1016\/j.prosdent.2014.11.007","article-title":"Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: a finite element analysis","volume":"113","author":"Bulaqi","year":"2015","journal-title":"J. Prosthet Dent."},{"key":"bpexad28cebib40","doi-asserted-by":"publisher","first-page":"2063","DOI":"10.1016\/j.jeurceramsoc.2019.12.064","article-title":"Temperature dependence of Young\u2019s modulus and damping of partially sintered and dense zirconia ceramics","volume":"40","author":"Gregorov\u00e1","year":"2020","journal-title":"J. Eur. Ceram. Soc."},{"key":"bpexad28cebib41","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2020.103937","article-title":"The influence of macro-textural designs over implant surface on bone on-growth: a computational mechanobiology based study","volume":"124","author":"Ghosh","year":"2020","journal-title":"Comput. Biol. Med."},{"key":"bpexad28cebib42","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2021.103661","article-title":"Zirconia-reinforced lithium silicate (ZLS) mechanical and biological properties: a literature review","volume":"109","author":"Zarone","year":"2021","journal-title":"J. Dent."},{"key":"bpexad28cebib43","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1016\/j.simpat.2008.05.009","article-title":"Stress-based performance evaluation of osseointegrated dental implants by finite-element simulation","volume":"16","author":"Baggi","year":"2008","journal-title":"Simul Model Pract. Theory"},{"key":"bpexad28cebib44","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.tafmec.2016.08.014","article-title":"Performance evaluation of dental implants: An experimental and numerical simulation study","volume":"85","author":"Bicudo","year":"2016","journal-title":"Theor. Appl. Fract. Mech."},{"key":"bpexad28cebib45","first-page":"67","article-title":"Biomechanical modelling of periodontal ligament behaviour under various mechanical loads","volume":"2","author":"Nyashin","year":"2000","journal-title":"Acta of Bioengineering and Biomechanics - Tom"},{"key":"bpexad28cebib46","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.compositesa.2016.01.007","article-title":"Matrix failure in composite laminates under compressive loading","volume":"84","author":"Chowdhury","year":"2016","journal-title":"Compos. Part A Appl. Sci. Manuf."},{"key":"bpexad28cebib47","doi-asserted-by":"publisher","first-page":"4133","DOI":"10.3390\/ijerph20054133","article-title":"Finite elements analysis of tooth\u2014a comparative analysis of multiple failure criteria","volume":"20","author":"Moga","year":"2023","journal-title":"Int. J. Environ Res. Public Heal."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad28ce","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad28ce\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad28ce","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad28ce\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad28ce\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad28ce\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad28ce\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad28ce\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T15:29:30Z","timestamp":1749914970000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad28ce"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,22]]},"references-count":47,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,2,22]]},"published-print":{"date-parts":[[2024,3,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad28ce","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,22]]},"assertion":[{"value":"Development of patient-specific finite element model for study of composite dental implants","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-08-14","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-13","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-02-22","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}