{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T00:59:40Z","timestamp":1777424380521,"version":"3.51.4"},"reference-count":28,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2024,4,9]],"date-time":"2024-04-09T00:00:00Z","timestamp":1712620800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,4,9]],"date-time":"2024-04-09T00:00:00Z","timestamp":1712620800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,5,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>For the purpose of fixing tibia fractures, composite bone plates are suggested. Metal plates cause stress shielding, lessen the compression force at the fracture site, and have an impact on the healing process because they are significantly more rigid than bone. To prevent excessive shear strain and consequent instability at the fracture site, it is imperative to reduce stiffness in the axial direction without lowering stiffness in the transverse direction. Only a carefully crafted fiber reinforced composite with anisotropic properties will suffice to accomplish this. The purpose of the current study is to examine the impact of axial and shear movements at the fracture site on the fixing of metal and composite bone plates. After modeling the tibia with a 1 mm fracture gap, titanium plates, carbon\/epoxy, carbon\/PEEK, and carbon\/UHMWPE composite bone plates were used to fix it. There are 6 holes on each of the 103 mm long plates. To determine the stresses and axial movement in the fracture site, anatomical 3D Finite Element (FE) models of the tibia with composite bone plates are built. The simulations that were run for various composite plate layouts and types give suggestions for selecting the best composite bone plate. Although the matrix material causes some variations in behaviors, most of the plates perform as well as or even better than metal plates. Thus, the appropriate composite combinations are recommended for a given fracture structure.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad38c4","type":"journal-article","created":{"date-parts":[[2024,3,28]],"date-time":"2024-03-28T22:20:40Z","timestamp":1711664440000},"page":"035026","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Effect of matrix material property on the composite tibia fracture plate: a biomechanical study"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-1481-6813","authenticated-orcid":true,"given":"Drupad","family":"Roy","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manik Chandra","family":"Das","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raja","family":"Dhason","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6888-272X","authenticated-orcid":false,"given":"Sandipan","family":"Roy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shubhabrata","family":"Datta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,4,9]]},"reference":[{"key":"bpexad38c4bib1","first-page":"115","article-title":"Anatomy of the knee and suitable prostheses","author":"Traina","year":"2013"},{"key":"bpexad38c4bib2","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/S0020-1383(98)00125-9","article-title":"The epidemiology of open long bone fractures","volume":"29","author":"Court-Brown","year":"1998","journal-title":"Injury"},{"key":"bpexad38c4bib3","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1097\/01.NOR.0000284648.52968.27","article-title":"Tibia fractures: an overview of evaluation and treatment","volume":"26","author":"Miller","year":"2007","journal-title":"Orthopaedic Nursing"},{"key":"bpexad38c4bib4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1471-2474-14-42","article-title":"Tibia shaft fractures: costly burden of nonunions","volume":"14","author":"Antonova","year":"2013","journal-title":"BMC Musculoskeletal Disorders"},{"key":"bpexad38c4bib5","doi-asserted-by":"publisher","first-page":"389","DOI":"10.3390\/medicina58030389","article-title":"Malunion of the tibia: a systematic review","volume":"58","author":"Patel","year":"2022","journal-title":"Medicina"},{"key":"bpexad38c4bib6","doi-asserted-by":"publisher","first-page":"S77","DOI":"10.1016\/j.injury.2021.06.015","article-title":"Intramedullary nail versus bridge plate in open tibial fractures-randomized clinical trial","volume":"52","author":"Balbachevsky","year":"2021","journal-title":"Injury"},{"key":"bpexad38c4bib7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40634-019-0209-1","article-title":"Mechanical strength of a new plate compared to six previously tested opening wedge high tibial osteotomy implants","volume":"6","author":"Diffo Kaze","year":"2019","journal-title":"Journal of Experimental Orthopaedics"},{"key":"bpexad38c4bib8","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1177\/0954411920941664","article-title":"Fixation of distal tibia fracture through plating, nailing, and nailing with Poller screws: a comparative biomechanical-based experimental and numerical investigation","volume":"234","author":"Baseri","year":"2020","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"bpexad38c4bib9","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1016\/j.injury.2018.12.016","article-title":"Comparison of plate and intramedullary nail fixation of extra-articular tibial fractures: a retrospective study exploring hidden blood loss","volume":"50","author":"Wang","year":"2019","journal-title":"Injury"},{"key":"bpexad38c4bib10","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1177\/14574969221111612","article-title":"Changes in operative treatment of tibia fractures in Finland between 2000 and 2018: a nationwide study","volume":"111","author":"Ylitalo","year":"2022","journal-title":"Scandinavian Journal of Surgery"},{"key":"bpexad38c4bib11","doi-asserted-by":"publisher","first-page":"2109","DOI":"10.1016\/j.compstruct.2009.09.051","article-title":"The finite element analysis of a fractured tibia applied by composite bone plates considering contact conditions and time-varying properties of curing tissues","volume":"92","author":"Kim","year":"2010","journal-title":"Compos. Struct."},{"key":"bpexad38c4bib12","doi-asserted-by":"crossref","first-page":"825","DOI":"10.3928\/01477447-20141124-05","article-title":"Use of carbon-fiber-reinforced composite implants in orthopedic surgery","volume":"37","author":"Hak","year":"2014","journal-title":"Orthopedics"},{"key":"bpexad38c4bib13","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1016\/j.compstruct.2014.07.052","article-title":"Application of composites to orthopedic prostheses for effective bone healing: a review","volume":"118","author":"Mehboob","year":"2014","journal-title":"Compos. Struct."},{"key":"bpexad38c4bib14","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1080\/10255842.2020.1867114","article-title":"A comparative finite element simulation of locking compression plate materials for tibial fracture treatment","volume":"24","author":"Beirami","year":"2021","journal-title":"Comput. Meth. Biomech. Biomed. Eng."},{"key":"bpexad38c4bib15","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.jmbbm.2014.11.015","article-title":"On optimization of a composite bone plate using the selective stress shielding approach","volume":"42","author":"Samiezadeh","year":"2015","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"bpexad38c4bib16","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2020.105680","article-title":"A biomechanical study on the laminate stacking sequence in composite bone plates for vancouver femur B1 fracture fixation","volume":"196","author":"Dhason","year":"2020","journal-title":"Comput. Methods Programs Biomed."},{"key":"bpexad38c4bib17","doi-asserted-by":"publisher","first-page":"1288","DOI":"10.1177\/09544119221116990","article-title":"The influence of composite bone plates in Vancouver femur B1 fracture fixation after post-operative, and healed bone stages: a finite element study","volume":"236","author":"Dhason","year":"2022","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"bpexad38c4bib18","doi-asserted-by":"publisher","first-page":"704","DOI":"10.1177\/03913988221108752","article-title":"Metal and composite bone plates for B1 periprosthetic femoral fracture in healthy and osteoporotic condition: a comparative biomechanical study","volume":"45","author":"Dhason","year":"2022","journal-title":"The International Journal of Artificial Organs"},{"key":"bpexad38c4bib19","article-title":"Biomechanical evaluation of three different configurations of external fixators for treating distal third tibia fracture: finite element analysis in axial, bending and torsion load","volume":"127","author":"Wahab","year":"2020","journal-title":"Comput. Biol. Med."},{"key":"bpexad38c4bib20","first-page":"145","article-title":"Epoxy composites in biomedical engineering","author":"Bobby","year":"2019"},{"key":"bpexad38c4bib21","first-page":"249","article-title":"Composite UHMWPE biomaterials and fibers","author":"Kurtz","year":"2009"},{"key":"bpexad38c4bib22","doi-asserted-by":"publisher","first-page":"2953","DOI":"10.1016\/j.compstruct.2011.05.008","article-title":"Finite element analysis using interfragmentary strain theory for the fracture healing process to which composite bone plates are applied","volume":"93","author":"Kim","year":"2011","journal-title":"Compos. Struct."},{"key":"bpexad38c4bib23","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1016\/j.compositesb.2011.02.009","article-title":"Bio-mechanical analysis of a fractured tibia with composite bone plates according to the diaphyseal oblique fracture angle","volume":"42","author":"Kim","year":"2011","journal-title":"Composites"},{"key":"bpexad38c4bib24","doi-asserted-by":"publisher","first-page":"1491","DOI":"10.1177\/0021998310383730","article-title":"Estimation of the movement of the inter-fragmentary gap of a fractured human femur in the presence of a composite bone plate","volume":"45","author":"Kim","year":"2011","journal-title":"J. Compos. Mater."},{"key":"bpexad38c4bib25","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2021.104303","article-title":"Biomechanical evaluation of glass fiber\/polypropylene composite bone fracture fixation plates: experimental and numerical analysis","volume":"132","author":"Kabiri","year":"2021","journal-title":"Comput. Biol. Med."},{"key":"bpexad38c4bib26","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1016\/S0021-9290(02)00086-6","article-title":"A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading","volume":"35","author":"Lacroix","year":"2002","journal-title":"J. Biomech."},{"key":"bpexad38c4bib27","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1177\/036354658701500613","article-title":"Transverse tibial stress fractures: a special problem","volume":"15","author":"Blank","year":"1987","journal-title":"The American Journal of Sports Medicine"},{"key":"bpexad38c4bib28","first-page":"471","article-title":"Fractures of the Tibia","author":"Schatzker","year":"2005"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad38c4","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad38c4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad38c4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad38c4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad38c4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad38c4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad38c4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad38c4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T15:34:29Z","timestamp":1749915269000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad38c4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,9]]},"references-count":28,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,4,9]]},"published-print":{"date-parts":[[2024,5,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad38c4","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,9]]},"assertion":[{"value":"Effect of matrix material property on the composite tibia fracture plate: a biomechanical study","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-11-02","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-03-28","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-04-09","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}