{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T10:51:33Z","timestamp":1753354293686,"version":"3.41.0"},"reference-count":34,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T00:00:00Z","timestamp":1713744000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T00:00:00Z","timestamp":1713744000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,5,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Utilising Machine Learning (ML) models to predict dosimetric parameters in pencil beam scanning proton therapy presents a promising and practical approach. The study developed Artificial Neural Network (ANN) models to predict proton beam spot size and relative positional errors using 9000 proton spot data. The irradiation log files as input variables and corresponding scintillation detector measurements as the label values. The ANN models were developed to predict six variables: spot size in the <jats:italic>x<\/jats:italic>-axis, <jats:italic>y<\/jats:italic>-axis, major axis, minor axis, and relative positional errors in the <jats:italic>x<\/jats:italic>-axis and <jats:italic>y<\/jats:italic>-axis. All ANN models used a Multi-layer perception (MLP) network using one input layer, three hidden layers, and one output layer. Model performance was validated using various statistical tools. The log file recorded spot size and relative positional errors, which were compared with scintillator-measured data. The Root Mean Squared Error (RMSE) values for the x-spot and y-spot sizes were 0.356 mm and 0.362 mm, respectively. Additionally, the maximum variation for the x-spot relative positional error was 0.910 mm, while for the y-spot, it was 1.610 mm. The ANN models exhibit lower prediction errors. Specifically, the RMSE values for spot size prediction in the x, y, major, and minor axes are 0.053 mm, 0.049 mm, 0.053 mm, and 0.052 mm, respectively. Additionally, the relative spot positional error prediction model for the x and y axes yielded maximum errors of 0.160 mm and 0.170 mm, respectively. The normality of models was validated using the residual histogram and Q-Q plot. The data over fit, and bias were tested using K (k = 5) fold cross-validation, and the maximum RMSE value of the K fold cross-validation among all the six ML models was less than 0.150 mm (R-Square 0.960). All the models showed excellent prediction accuracy. Accurately predicting beam spot size and positional errors enhances efficiency in routine dosimetric checks.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad3ce0","type":"journal-article","created":{"date-parts":[[2024,4,23]],"date-time":"2024-04-23T16:43:44Z","timestamp":1713890624000},"page":"035033","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["An artificial neural network based approach for predicting the proton beam spot dosimetric characteristics of a pencil beam scanning technique"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4668-9099","authenticated-orcid":false,"given":"C P","family":"Ranjith","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2345-2029","authenticated-orcid":true,"given":"Mayakannan","family":"Krishnan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9549-4231","authenticated-orcid":true,"given":"Vysakh","family":"Raveendran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lalit","family":"Chaudhari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siddhartha","family":"Laskar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,4,22]]},"reference":[{"key":"bpexad3ce0bib1","doi-asserted-by":"publisher","first-page":"196","DOI":"10.3978\/j.issn.2218-676X.2012.10.08","article-title":"Improving the precision and performance of proton pencil beam scanning","volume":"1","author":"Safai","year":"2012","journal-title":"Transl. Cancer Res."},{"key":"bpexad3ce0bib2","doi-asserted-by":"publisher","first-page":"e678","DOI":"10.1002\/mp.13622","article-title":"AAPM task group 224: comprehensive proton therapy machine quality assurance","volume":"46","author":"Arjomandy","year":"2019","journal-title":"Med. Phys."},{"key":"bpexad3ce0bib3","doi-asserted-by":"publisher","DOI":"10.1118\/1.4885956","article-title":"Implication of spot position error on plan quality and patient safety in pencil-beam-scanning proton therapy","volume":"41","author":"Yu","year":"2014","journal-title":"Med. Phys."},{"key":"bpexad3ce0bib4","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1007\/s12194-021-00625-3","article-title":"Impact of spot positional errors in robustly optimized intensity-modulated proton therapy plan of craniospinal irradiation","volume":"14","author":"Noufal","year":"2021","journal-title":"Radiol. Phys. Technol."},{"key":"bpexad3ce0bib5","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1002\/acm2.13293","article-title":"Impact of errors in spot size and spot position in robustly optimized pencil beam scanning proton-based stereotactic body radiation therapy (SBRT) lung plans","volume":"22","author":"Rana","year":"2021","journal-title":"Journal of Applied Clinical Medical Physics"},{"key":"bpexad3ce0bib6","doi-asserted-by":"publisher","DOI":"10.1016\/j.imu.2020.100292","article-title":"Application and comparison of machine learning models for predicting quality assurance outcomes in radiation therapy treatment planning","volume":"18","author":"Wall","year":"2020","journal-title":"Informatics in Medicine Unlocked"},{"key":"bpexad3ce0bib7","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.meddos.2021.02.003","article-title":"Mean parotid dose prediction model using machine learning regression method for intensity-modulated radiotherapy in head and neck cancer","volume":"46","author":"Ranjith","year":"2021","journal-title":"Med. Dosim."},{"key":"bpexad3ce0bib8","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1002\/acm2.12899","article-title":"Prediction of the output factor using machine and deep learning approach in uniform scanning proton therapy","volume":"21","author":"Grewal","year":"2020","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexad3ce0bib9","doi-asserted-by":"publisher","first-page":"5748","DOI":"10.1002\/mp.13827","article-title":"Machine learning approaches for range and dose verification in proton therapy using proton-induced positron emitters","volume":"46","author":"Li","year":"2019","journal-title":"Med. Phys."},{"key":"bpexad3ce0bib10","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13911","article-title":"Spot delivery error predictions for intensity modulated proton therapy using robustness analysis with machine learning","volume":"24","author":"Newpower","year":"2023","journal-title":"Journal of Applied Clinical Medical Physics"},{"key":"bpexad3ce0bib11","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.ejmp.2020.09.008","article-title":"A machine learning-based framework for delivery error prediction in proton pencil beam scanning using irradiation log-files","volume":"78","author":"Maes","year":"2020","journal-title":"Physica Med."},{"key":"bpexad3ce0bib12","doi-asserted-by":"publisher","DOI":"10.1088\/2632-2153\/abb6d5","article-title":"Improving proton dose calculation accuracy by using deep learning","volume":"2","author":"Wu","year":"2021","journal-title":"Machine Learning: Science and Technology"},{"key":"bpexad3ce0bib13","doi-asserted-by":"publisher","first-page":"5451","DOI":"10.1002\/mp.15702","article-title":"Feasibility study of fast intensity-modulated proton therapy dose prediction method using deep neural networks for prostate cancer","volume":"49","author":"Wang","year":"2022","journal-title":"Med. Phys."},{"key":"bpexad3ce0bib14","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aba164","article-title":"Fast spot-scanning proton dose calculation method with uncertainty quantification using a three-dimensional convolutional neural network","volume":"65","author":"Nomura","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"bpexad3ce0bib15","doi-asserted-by":"publisher","first-page":"1893","DOI":"10.1002\/mp.14658","article-title":"Long short-term memory networks for proton dose calculation in highly heterogeneous tissues","volume":"48","author":"Neishabouri","year":"2021","journal-title":"Med. Phys."},{"key":"bpexad3ce0bib16","doi-asserted-by":"publisher","first-page":"12071","DOI":"10.1609\/aaai.v36i11.21466","article-title":"Learning the physics of particle transport via transformers","volume":"36","author":"Pastor-Serrano","year":"2022"},{"key":"bpexad3ce0bib17","doi-asserted-by":"publisher","first-page":"1140","DOI":"10.1002\/mp.13371","article-title":"Log file-based dose reconstruction and accumulation for 4D adaptive pencil beam scanned proton therapy in a clinical treatment planning system: Implementation and proof-of-concept","volume":"46","author":"Meijers","year":"2019","journal-title":"Med. Phys."},{"key":"bpexad3ce0bib18","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab120c","article-title":"Impact of machine log-files uncertainties on the quality assurance of proton pencil beam scanning treatment delivery","volume":"64","author":"Toscano","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"bpexad3ce0bib19","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.inffus.2021.05.008","article-title":"A review of uncertainty quantification in deep learning: Techniques, applications and challenges","volume":"76","author":"Abdar","year":"2021","journal-title":"Information Fusion"},{"key":"bpexad3ce0bib20","doi-asserted-by":"crossref","first-page":"e678","DOI":"10.1002\/mp.13622","article-title":"AAPM task group 224: Comprehensive proton therapy machine quality assurance","volume":"46","author":"Arjomandy","year":"2019","journal-title":"Med. Phys."},{"key":"bpexad3ce0bib21","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.ejmp.2017.01.011","article-title":"Characterization of a commercial scintillation detector for 2-D dosimetry in scanned proton and carbon ion beams","volume":"34","author":"Russo","year":"2017","journal-title":"Physica Med."},{"key":"bpexad3ce0bib22","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.nima.2013.10.014","article-title":"Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning","volume":"736","author":"Courtois","year":"2014","journal-title":"Nucl. Instrum. Methods Phys. Res."},{"key":"bpexad3ce0bib23","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/5681308","article-title":"Forecasting drought using multilayer perceptron artificial neural network model","volume":"2017","author":"Ali","year":"2017","journal-title":"Advances in Meteorology"},{"key":"bpexad3ce0bib24","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/978-1-4842-2766-4_7","article-title":"Introduction to keras","author":"Ketkar","year":"2017"},{"key":"bpexad3ce0bib25","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1063\/1.1144830","article-title":"Neural networks and their applications","volume":"65","author":"Bishop","year":"1994","journal-title":"Rev. Sci. Instrum."},{"article-title":"Deep learning using rectified linear units (relu)","year":"2018","author":"Agarap","key":"bpexad3ce0bib26"},{"key":"bpexad3ce0bib27","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1023\/A:1018966222807","article-title":"Introduction to backpropagation neural network computation","volume":"10","author":"Erb","year":"1993","journal-title":"Pharm. Res."},{"key":"bpexad3ce0bib28","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1109\/IJCNN.2004.1379938","article-title":"Comparison of loss functions for linear regression","volume":"1","author":"Cherkassky","year":"2004"},{"key":"bpexad3ce0bib29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/IWQoS.2018.8624183","article-title":"Improved adam optimizer for deep neural networks","author":"Zhang","year":"2018"},{"key":"bpexad3ce0bib30","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2020.110515","article-title":"An overview of performance evaluation metrics for short-term statistical wind power forecasting","volume":"138","author":"Gonz\u00e1lez-Sope\u00f1a","year":"2021","journal-title":"Renew. Sustain. Energy Rev."},{"key":"bpexad3ce0bib31","doi-asserted-by":"publisher","first-page":"5","DOI":"10.11648\/j.ajtas.20160501.12","article-title":"A brief review of tests for normality","volume":"5","author":"Das","year":"2016","journal-title":"American Journal of Theoretical and Applied Statistics"},{"key":"bpexad3ce0bib32","doi-asserted-by":"publisher","first-page":"1661","DOI":"10.1088\/1361-6560\/aa5131","article-title":"A comprehensive and efficient daily quality assurance for PBS proton therapy","volume":"62","author":"Actis","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"bpexad3ce0bib33","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1002\/acm2.12556","article-title":"Development and long-term stability of a comprehensive daily QA program for a modern pencil beam scanning (PBS) proton therapy delivery system","volume":"20","author":"Rana","year":"2019","journal-title":"Journal of Applied Clinical Medical Physics"},{"key":"bpexad3ce0bib34","doi-asserted-by":"publisher","first-page":"514","DOI":"10.1016\/j.radonc.2017.09.037","article-title":"Treatment log files as a tool to identify treatment plan sensitivity to inaccuracies in scanned proton beam delivery","volume":"125","author":"Belosi","year":"2017","journal-title":"Radiother. Oncol."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad3ce0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad3ce0\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad3ce0\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad3ce0\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T15:37:38Z","timestamp":1749915458000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad3ce0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,22]]},"references-count":34,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,4,22]]},"published-print":{"date-parts":[[2024,5,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad3ce0","relation":{},"ISSN":["2057-1976"],"issn-type":[{"type":"electronic","value":"2057-1976"}],"subject":[],"published":{"date-parts":[[2024,4,22]]},"assertion":[{"value":"An artificial neural network based approach for predicting the proton beam spot dosimetric characteristics of a pencil beam scanning technique","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2023-11-29","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-04-10","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-04-22","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}