{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T16:10:04Z","timestamp":1749917404953,"version":"3.41.0"},"reference-count":24,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2024,6,26]],"date-time":"2024-06-26T00:00:00Z","timestamp":1719360000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,6,26]],"date-time":"2024-06-26T00:00:00Z","timestamp":1719360000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,7,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective<\/jats:italic>: To summarize our institutional prostate stereotactic body radiation therapy (SBRT) experience using auto beam hold (ABH) technique for intrafractional prostate motion and assess ABH tolerance of 10-millimeter (mm) diameter. <jats:italic>Approach<\/jats:italic>: Thirty-two patients (160 fractions) treated using ABH technique between 01\/2018 and 03\/2021 were analyzed. During treatment, kV images were acquired every 20-degree gantry rotation to visualize 3\u20134 gold fiducials within prostate to track target motion. If the fiducial center fell outside the tolerance circle (diameter = 10 mm), beam was automatically turned off for reimaging and repositioning. Number of beam holds and couch translational movement magnitudes were recorded. Dosimetric differences from intrafractional motion were calculated by shifting planned isocenter. <jats:italic>Main Results<\/jats:italic>: Couch movement magnitude (mean \u00b1 SD) in vertical, longitudinal and lateral directions were \u22120.7 \u00b1 2.5, 1.4 \u00b1 2.9 and \u22120.1 \u00b1 0.9 mm, respectively. For most fractions (77.5%), no correction was necessary. Number of fractions requiring one, two, or three corrections were 15.6%, 5.6% and 1.3%, respectively. Of the 49 corrections, couch shifts greater than 3 mm were seen primarily in the vertical (31%) and longitudinal (39%) directions; corresponding couch shifts greater than 5 mm occurred in 2% and 6% of cases. Dosimetrically, 100% coverage decreased less than 2% for clinical target volume (CTV) (\u22121 \u00b1 2%) and less than 10% for PTV (\u221210 \u00b1 6%). Dose to bladder, bowel and urethra tended to increase (Bladder: \u0394D10%:184 \u00b1 466 cGy, \u0394D40%:139 \u00b1 241 cGy, Bowel: \u0394D1 cm<jats:sup>3<\/jats:sup>:54 \u00b1 129 cGy; \u0394D5 cm<jats:sup>3<\/jats:sup>:44 \u00b1 116 cGy, Urethra: \u0394D0.03 cm<jats:sup>3<\/jats:sup>:1 \u00b1 1%). Doses to the rectum tended to decrease (Rectum: \u0394D1 cm<jats:sup>3<\/jats:sup>:\u2212206 \u00b1 564 cGy, \u0394D10%:\u221297 \u00b1 426 cGy; \u0394D20%:\u221250 \u00b1 251 cGy). <jats:italic>Significance<\/jats:italic>: With the transition from conventionally fractionated intensity modulated radiation therapy to SBRT for localized prostate cancer treatment, it is imperative to ensure that dose delivery is spatially accurate for appropriate coverage to target volumes and limiting dose to surrounding organs. Intrafractional motion monitoring can be achieved using triggered imaging to image fiducial markers and ABH to allow for reimaging and repositioning for excessive motion.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad4b1d","type":"journal-article","created":{"date-parts":[[2024,6,26]],"date-time":"2024-06-26T17:04:05Z","timestamp":1719421445000},"page":"045052","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Intrafractional motion and dosimetric analysis in prostate stereotactic body radiation therapy with auto beam hold technique"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1583-3665","authenticated-orcid":true,"given":"Renee F","family":"Cattell","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"An Ting","family":"Hsia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinkoo","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Qian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siming","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Slade","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kartik","family":"Mani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel","family":"Ryu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhigang","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,6,26]]},"reference":[{"key":"bpexad4b1dbib1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab2ba8","article-title":"Real-time intrafraction motion monitoring in external beam radiotherapy","volume":"64","author":"Bertholet","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"bpexad4b1dbib2","doi-asserted-by":"publisher","first-page":"1531","DOI":"10.1016\/S1470-2045(19)30569-8","article-title":"Intensity-modulated fractionated radiotherapy versus stereotactic body radiotherapy for prostate cancer (PACE-B): acute toxicity findings from an international, randomised, open-label, phase 3, non-inferiority trial","volume":"20","author":"Brand","year":"2019","journal-title":"Lancet Oncol."},{"key":"bpexad4b1dbib3","doi-asserted-by":"publisher","first-page":"E748","DOI":"10.1016\/j.ijrobp.2019.06.862","article-title":"Dosimetric effects of intrafraction motion detected by triggered imaging during prostate SBRT","volume":"105","author":"Bright","year":"2019","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexad4b1dbib4","doi-asserted-by":"publisher","first-page":"e388","DOI":"10.1016\/j.prro.2020.04.013","article-title":"Prostate SBRT with intrafraction motion management using a novel linear accelerator-based MV-kV imaging method","volume":"10","author":"Gorovets","year":"2020","journal-title":"Pract Radiat Oncol"},{"key":"bpexad4b1dbib5","doi-asserted-by":"publisher","first-page":"E749","DOI":"10.1016\/j.ijrobp.2019.06.865","article-title":"Monitoring intra-fraction prostate motion using Kv triggered imaging during SBRT","volume":"105","author":"Guo","year":"2019","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexad4b1dbib6","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.ijrobp.2019.03.051","article-title":"Stereotactic body radiation therapy for localized prostate cancer: a systematic review and meta-analysis of over 6,000 patients treated on prospective studies","volume":"104","author":"Jackson","year":"2019","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexad4b1dbib7","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1016\/j.ijrobp.2010.11.054","article-title":"Long-term outcomes from a prospective trial of stereotactic body radiotherapy for low-risk prostate cancer","volume":"82","author":"King","year":"2012","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexad4b1dbib8","doi-asserted-by":"publisher","DOI":"10.1001\/jamanetworkopen.2018.8006","article-title":"Long-term outcomes of stereotactic body radiotherapy for low-risk and intermediate-risk prostate cancer","volume":"2","author":"Kishan","year":"2019","journal-title":"JAMA Netw Open"},{"key":"bpexad4b1dbib9","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/j.prro.2015.11.002","article-title":"SBRT and HDR brachytherapy produce lower PSA nadirs and different PSA decay patterns than conventionally fractionated IMRT in patients with low- or intermediate-risk prostate cancer","volume":"6","author":"Kishan","year":"2016","journal-title":"Pract Radiat Oncol"},{"key":"bpexad4b1dbib10","doi-asserted-by":"publisher","first-page":"e210","DOI":"10.1016\/j.prro.2020.04.014","article-title":"Triggered imaging with auto beam hold and Pre-\/Posttreatment CBCT during prostate SABR: analysis of time efficiency, target coverage, and normal volume changes","volume":"11","author":"Kisivan","year":"2021","journal-title":"Pract Radiat Oncol"},{"key":"bpexad4b1dbib11","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0195296","article-title":"Dosimetric impact of intra-fraction prostate motion under a tumour-tracking system in hypofractionated robotic radiosurgery","volume":"13","author":"Koike","year":"2018","journal-title":"PLoS One"},{"key":"bpexad4b1dbib12","doi-asserted-by":"crossref","first-page":"539","DOI":"10.3389\/fonc.2020.00539","article-title":"Clinical assessment of prostate displacement and planning target volume margins for stereotactic body radiotherapy of prostate cancer","volume":"10","author":"Levin-Epstein","year":"2020","journal-title":"Front Oncol"},{"key":"bpexad4b1dbib13","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.ijrobp.2018.06.008","article-title":"Patient reported outcomes in NRG oncology RTOG 0938, evaluating two ultrahypofractionated regimens for prostate cancer","volume":"102","author":"Lukka","year":"2018","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexad4b1dbib14","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1038\/s41391-019-0191-9","article-title":"Current use of stereotactic body radiation therapy for low and intermediate risk prostate cancer: a national cancer database analysis","volume":"23","author":"Malouff","year":"2020","journal-title":"Prostate Cancer and Prostatic Diseases"},{"key":"bpexad4b1dbib15","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/j.ijrobp.2018.05.040","article-title":"Multicenter trial of stereotactic body radiation therapy for low- and intermediate-risk prostate cancer: survival and toxicity endpoints","volume":"102","author":"Meier","year":"2018","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexad4b1dbib16","doi-asserted-by":"publisher","first-page":"1823","DOI":"10.1200\/JCO.2017.75.5371","article-title":"Comparative toxicities and cost of intensity-modulated radiotherapy, proton radiation, and stereotactic body radiotherapy among younger men with prostate cancer","volume":"36","author":"Pan","year":"2018","journal-title":"J Clin Oncol"},{"key":"bpexad4b1dbib17","doi-asserted-by":"publisher","DOI":"10.1177\/1557988320927241","article-title":"Stereotactic body radiotherapy for prostate cancer","volume":"14","author":"Parikh","year":"2020","journal-title":"Am J Mens Health"},{"key":"bpexad4b1dbib18","doi-asserted-by":"crossref","first-page":"184","DOI":"10.3389\/fonc.2016.00184","article-title":"The comparison of stereotactic body radiation therapy and intensity-modulated radiation therapy for prostate cancer by NCCN risk groups","volume":"6","author":"Ricco","year":"2016","journal-title":"Front Oncol"},{"key":"bpexad4b1dbib19","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/j.prro.2018.04.008","article-title":"Toward planning target volume margin reduction for the prostate using intrafraction motion correction with online kV imaging and automatic detection of implanted gold seeds","volume":"8","author":"Rosario","year":"2018","journal-title":"Pract Radiat Oncol"},{"key":"bpexad4b1dbib20","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ejmp.2020.06.010","article-title":"Dosimetric effect of intrafraction motion and different localization strategies in prostate SBRT","volume":"75","author":"Vanhanen","year":"2020","journal-title":"Phys Med"},{"key":"bpexad4b1dbib21","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1053\/j.semradonc.2003.10.003","article-title":"Errors and margins in radiotherapy","volume":"14","author":"Van Herk","year":"2004","journal-title":"Semin. Radiat. Oncol."},{"key":"bpexad4b1dbib22","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.radonc.2019.04.013","article-title":"Dosimetric impact of intrafraction rotations in stereotactic prostate radiotherapy: a subset analysis of the TROG 15.01 SPARK trial","volume":"136","author":"Wolf","year":"2019","journal-title":"Radiother. Oncol."},{"key":"bpexad4b1dbib23","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1186\/1748-717X-8-215","article-title":"Single institution\u2019s dosimetry and IGRT analysis of prostate SBRT","volume":"8","author":"Wu","year":"2013","journal-title":"Radiat Oncol"},{"key":"bpexad4b1dbib24","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.ijrobp.2008.04.051","article-title":"Intrafractional motion of the prostate during hypofractionated radiotherapy","volume":"72","author":"Xie","year":"2008","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad4b1d","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad4b1d\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad4b1d\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad4b1d\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T15:41:48Z","timestamp":1749915708000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad4b1d"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,26]]},"references-count":24,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,6,26]]},"published-print":{"date-parts":[[2024,7,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad4b1d","relation":{},"ISSN":["2057-1976"],"issn-type":[{"type":"electronic","value":"2057-1976"}],"subject":[],"published":{"date-parts":[[2024,6,26]]},"assertion":[{"value":"Intrafractional motion and dosimetric analysis in prostate stereotactic body radiation therapy with auto beam hold technique","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-01-15","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-14","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-06-26","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}