{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T20:31:45Z","timestamp":1772137905461,"version":"3.50.1"},"reference-count":21,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2024,6,20]],"date-time":"2024-06-20T00:00:00Z","timestamp":1718841600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,6,20]],"date-time":"2024-06-20T00:00:00Z","timestamp":1718841600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,7,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Background.<\/jats:italic>\n                    The MTF has difficulties being determined (according to the provisions of the IEC standards) in the hospital setting due to the lack of resources.\n                    <jats:italic>Purpose.<\/jats:italic>\n                    The objective of this work is to propose a quantitative method for obtaining the point spread function (\n                    <jats:italic>PSF<\/jats:italic>\n                    ) and the modulation transfer function (\n                    <jats:italic>MTF<\/jats:italic>\n                    ) of a digital mammography system from an image of a bar pattern.\n                    <jats:italic>Methods.<\/jats:italic>\n                    The method is based on the measurement of the contrast transfer function (\n                    <jats:italic>CTF<\/jats:italic>\n                    ) of the system over the image of the bar pattern. In addition, a theoretical model for the\n                    <jats:italic>PSF<\/jats:italic>\n                    is proposed, from which the theoretical\n                    <jats:italic>CTF<\/jats:italic>\n                    of the system is obtained by means of convolution with a square wave (mathematical simulation of the bar pattern). Through an iterative process, the free parameters of the\n                    <jats:italic>PSF<\/jats:italic>\n                    model are varied until the experimental\n                    <jats:italic>CTF<\/jats:italic>\n                    coincides with the one calculated by convolution. Once the\n                    <jats:italic>PSF<\/jats:italic>\n                    of the system is obtained, we calculate the\n                    <jats:italic>MTF<\/jats:italic>\n                    by means of its Fourier transform. The\n                    <jats:italic>MTF<\/jats:italic>\n                    calculated from the model\n                    <jats:italic>PSF<\/jats:italic>\n                    have been compared with those calculated from an image of a 65\n                    <jats:italic>\u03bc<\/jats:italic>\n                    m diameter gold wire using an oversampling process.\n                    <jats:italic>Results.<\/jats:italic>\n                    The\n                    <jats:italic>CTF<\/jats:italic>\n                    has been calculated for three digital mammographic systems (DMS 1, DMS 2 and DMS 3), no differences of more than 5 % were found with the CTF obtained with the PSF model. The comparison of the\n                    <jats:italic>MTF<\/jats:italic>\n                    shows us the goodness of the\n                    <jats:italic>PSF<\/jats:italic>\n                    model.\n                    <jats:italic>Conclusions.<\/jats:italic>\n                    The proposed method for obtaining\n                    <jats:italic>PSF<\/jats:italic>\n                    and\n                    <jats:italic>MTF<\/jats:italic>\n                    is a simple and accessible method, which does not require a complex configuration or the use of phantoms that are difficult to access in the hospital world. In addition, it can be used to calculate other magnitudes of interest such as the normalized noise power spectrum (\n                    <jats:italic>NNPS<\/jats:italic>\n                    ) and the detection quantum efficiency (\n                    <jats:italic>DQE<\/jats:italic>\n                    ).\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ad5296","type":"journal-article","created":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T18:21:03Z","timestamp":1717179663000},"page":"045051","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["PSF and MTF from a bar pattern in digital mammography"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0165-1772","authenticated-orcid":true,"given":"F R","family":"Lozano","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Rojo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L C","family":"Mart\u00ednez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos","family":"Ramon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,6,20]]},"reference":[{"key":"bpexad5296bib1","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/9605439","article-title":"Global increase in breast cancer incidence: risk factors and preventive measures","volume":"2022","author":"Kashyap","year":"2022","journal-title":"Biomed Res Int."},{"key":"bpexad5296bib2","doi-asserted-by":"publisher","first-page":"524","DOI":"10.3322\/caac.21754","article-title":"Breast cancer statistics, 2022","volume":"72","author":"Giaquinto","year":"2022","journal-title":"CA: A Cancer Journal for Clinicians"},{"key":"bpexad5296bib3","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/j.canep.2012.02.007","article-title":"The descriptive epidemiology of female breast cancer: an international comparison of screening, incidence, survival and mortality","volume":"36","author":"Youlden","year":"2012","journal-title":"Cancer Epidemiol"},{"key":"bpexad5296bib4","doi-asserted-by":"publisher","first-page":"3317","DOI":"10.1109\/TBME.2020.2983539","article-title":"Mammography image quality assurance using deep learning","volume":"67","author":"Kretz","year":"2020","journal-title":"IEEE Trans Biomed. Eng."},{"key":"bpexad5296bib5","doi-asserted-by":"publisher","first-page":"52","DOI":"10.7705\/biomedica.5135","article-title":"Image quality, reading, and mammography service in four diagnostic imaging centers in Manizales, Colombia","volume":"41","author":"Garc\u00eda","year":"2021","journal-title":"Biomedica"},{"key":"bpexad5296bib6","doi-asserted-by":"publisher","first-page":"3202","DOI":"10.1118\/1.4718571","article-title":"Effect of image quality on calcification detection in digital mammography","volume":"39","author":"Warren","year":"2012","journal-title":"Med. Phys."},{"key":"bpexad5296bib7","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/634856","article-title":"Figure of image quality and information capacity in digital mammography","volume":"2014","author":"Michail","year":"2014","journal-title":"Biomed. Res. Int."},{"key":"bpexad5296bib8"},{"key":"bpexad5296bib9","doi-asserted-by":"publisher","first-page":"1684","DOI":"10.1118\/1.1921667","article-title":"Validation of MTF measurement for digital mammography quality control","volume":"32","author":"Carton","year":"2005","journal-title":"Med. Phys."},{"key":"bpexad5296bib10","doi-asserted-by":"publisher","DOI":"10.1889\/1.2372416","article-title":"MTF measurement method for medical displays by using a bar-pattern image","volume":"14","author":"Ichikawa","year":"2006","journal-title":"J. Soc. Inf. Disp."},{"key":"bpexad5296bib11","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1118\/1.598165","article-title":"A method for measuring the presampled MTF of digital radiographic systems using an edge test device","volume":"25","author":"Samei","year":"1998","journal-title":"Med. Phys."},{"key":"bpexad5296bib12","doi-asserted-by":"publisher","first-page":"5653","DOI":"10.1118\/1.4963211","article-title":"Technical Note: an oversampling procedure to calculate the MTF of an imaging system from a bar-pattern image","volume":"43","author":"Gonzalez-Lopez","year":"2016","journal-title":"Med. Phys."},{"key":"bpexad5296bib13","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1109\/42.126908","article-title":"A simple method for determining the modulation transfer function in digital radiography","volume":"11","author":"Fujita","year":"1992","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexad5296bib14","doi-asserted-by":"publisher","DOI":"10.1118\/1.4870955","article-title":"Free software for performing physical analysis of systems for digital radiography and mammography","volume":"41","author":"Donini","year":"2014","journal-title":"Med. Phys."},{"key":"bpexad5296bib15","article-title":"Comparison of several methodologies for MTF calculation in mammography using a new software (CC dm )","volume":"20","author":"Lozano","year":"2019","journal-title":"Revista De Fisica Medica"},{"key":"bpexad5296bib16","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1259\/bjr.72.862.10673949","article-title":"A phantom-based evaluation of an exposure equalization technique in mammography","volume":"72","author":"Skiadopoulos","year":"1999","journal-title":"Brit. J. Radiol."},{"key":"bpexad5296bib17","doi-asserted-by":"publisher","DOI":"10.1088\/1748-0221\/4\/05\/P05018","article-title":"The influence of software filtering in digital mammography image quality","volume":"4","author":"Michail","year":"2009","journal-title":"J. Instrum."},{"key":"bpexad5296bib18","first-page":"257","article-title":"Point spread-function, line spread-function, and modulation transfer function","volume":"93","author":"Rossman","year":"1969","journal-title":"Tools for the study of imaging systems, Radiology"},{"key":"bpexad5296bib19","article-title":"Performance analysis of flat panel detector and film digitizer based on modulation transfer function","volume":"2009","author":"Vaishnavi","year":"2010","journal-title":"Indian National Seminar & Exhibition on Non-Destructive Evaluation NDE"},{"key":"bpexad5296bib20","author":"Beutel","year":"2000"},{"key":"bpexad5296bib21","doi-asserted-by":"crossref","DOI":"10.1088\/1742-6596\/705\/1\/012057","article-title":"Application of Oversampling to obtain the MTF of Digital Radiology Equipment","volume":"705","author":"Narvaez","year":"2016","journal-title":"J. Phys. Conf. Ser."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5296","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5296\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5296","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5296\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5296\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5296\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5296\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5296\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T11:40:45Z","timestamp":1749901245000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5296"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,20]]},"references-count":21,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,6,20]]},"published-print":{"date-parts":[[2024,7,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad5296","relation":{"has-review":[{"id-type":"doi","id":"10.1088\/2057-1976\/AD5296\/v1\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/AD5296\/v2\/response1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/AD5296\/v3\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/AD5296\/v2\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/AD5296\/v3\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/AD5296\/v1\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/AD5296\/v3\/response1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2057-1976\/AD5296\/v2\/decision1","asserted-by":"object"}]},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,20]]},"assertion":[{"value":"PSF and MTF from a bar pattern in digital mammography","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-01-24","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-05-31","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-06-20","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}