{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T17:52:20Z","timestamp":1793641940019,"version":"4.5.1"},"reference-count":28,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2024,7,11]],"date-time":"2024-07-11T00:00:00Z","timestamp":1720656000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,7,11]],"date-time":"2024-07-11T00:00:00Z","timestamp":1720656000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Invasive ductal carcinoma (IDC) in breast specimens has been detected in the quadrant breast area: (I) upper outer, (II) upper inner, (III) lower inner, and (IV) lower outer areas by electrical impedance tomography implemented with Gaussian relaxation-time distribution (EIT-GRTD). The EIT-GRTD consists of two steps which are (1) the optimum frequency <jats:inline-formula>\n                     <jats:tex-math>\n\n<\/jats:tex-math>\n                     <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msup>\n                           <mml:mrow>\n                              <mml:mi>f<\/mml:mi>\n                           <\/mml:mrow>\n                           <mml:mrow>\n                              <mml:mi mathvariant=\"normal\">opt<\/mml:mi>\n                           <\/mml:mrow>\n                        <\/mml:msup>\n                     <\/mml:math>\n                  \n                  <\/jats:inline-formula> selection and (2) the time constant enhancement of breast imaging reconstruction. <jats:inline-formula>\n                     <jats:tex-math>\n\n<\/jats:tex-math>\n                     <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msup>\n                           <mml:mrow>\n                              <mml:mi>f<\/mml:mi>\n                           <\/mml:mrow>\n                           <mml:mrow>\n                              <mml:mi mathvariant=\"normal\">opt<\/mml:mi>\n                           <\/mml:mrow>\n                        <\/mml:msup>\n                     <\/mml:math>\n                  \n                  <\/jats:inline-formula> is characterized by a peak in the majority measurement pair of the relaxation-time distribution function <jats:inline-formula>\n                     <jats:tex-math>\n\n<\/jats:tex-math>\n                     <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mi>\u03b3<\/mml:mi>\n                        <mml:mo>,<\/mml:mo>\n                     <\/mml:math>\n                  \n                  <\/jats:inline-formula> which indicates the presence of IDC. <jats:italic>\u03b3<\/jats:italic> represents the inverse of conductivity and indicates the response of breast tissues to electrical currents across varying frequencies based on the Voigt circuit model. The EIT-GRTD is quantitatively evaluated by multi-physics simulations using a hemisphere container of mimic breast, consisting of IDC and adipose tissues as normal breast tissue under one condition with known IDC in quadrant breast area II. The simulation results show that EIT-GRTD is able to detect the IDC in four layers at <jats:inline-formula>\n                     <jats:tex-math>\n\n<\/jats:tex-math>\n                     <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msup>\n                           <mml:mrow>\n                              <mml:mi>f<\/mml:mi>\n                           <\/mml:mrow>\n                           <mml:mrow>\n                              <mml:mi mathvariant=\"normal\">opt<\/mml:mi>\n                           <\/mml:mrow>\n                        <\/mml:msup>\n                     <\/mml:math>\n                  \n                  <\/jats:inline-formula> = 30, 170 Hz. EIT-GRTD is applied in the real breast by employed six mastectomy specimens from IDC patients. The placement of the mastectomy specimens in a hemisphere container is an important factor in the success of quadrant breast area reconstruction. In order to perform the evaluation, EIT-GRTD reconstruction images are compared to the CT scan images. The experimental results demonstrate that EIS-GRTD exhibits proficiency in the detection of the IDC in quadrant breast areas while compared qualitatively to CT scan images.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad5db1","type":"journal-article","created":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T22:21:02Z","timestamp":1719958862000},"page":"055007","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Detection of invasive ductal carcinoma in quadrant breast areas by electrical impedance tomography implemented with gaussian relaxation-time distribution (EIT-GRTD)"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8023-6950","authenticated-orcid":true,"given":"Galih","family":"Setyawan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0509-841X","authenticated-orcid":true,"given":"Prima Asmara","family":"Sejati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3505-8029","authenticated-orcid":false,"given":"Ryoma","family":"Ogawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6015-9422","authenticated-orcid":true,"given":"Kiagus Aufa","family":"Ibrahim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Fujimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroto","family":"Yamamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3855-7202","authenticated-orcid":false,"given":"Masahiro","family":"Takei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2024,7,11]]},"reference":[{"key":"bpexad5db1bib1","doi-asserted-by":"publisher","first-page":"e102","DOI":"10.1016\/j.clbc.2020.08.005","article-title":"MR elastography of the breast: evolution of technique, case examples, and future directions","volume":"21","author":"Patel","year":"2021","journal-title":"Clin. Breast. Cancer"},{"key":"bpexad5db1bib2","doi-asserted-by":"publisher","first-page":"23","DOI":"10.4137\/CPath.S31563","article-title":"Diversity of breast carcinoma: histological subtypes and clinical relevance","volume":"8","author":"Makki","year":"2015","journal-title":"Clin. Med. Insights Pathol."},{"key":"bpexad5db1bib3","doi-asserted-by":"publisher","DOI":"10.1126\/science.aay9040","article-title":"Early detection of cancer","volume":"375","author":"Crosby","year":"2022","journal-title":"Science"},{"key":"bpexad5db1bib4","doi-asserted-by":"publisher","first-page":"623","DOI":"10.3892\/mco.2014.297","article-title":"Association between mammographic features and clinicopathological characteristics in invasive ductal carcinoma of breast cancer","volume":"2","author":"Sun","year":"2014","journal-title":"Mol. Clin. Oncol."},{"key":"bpexad5db1bib5","doi-asserted-by":"publisher","first-page":"2078","DOI":"10.3390\/diagnostics13122078","article-title":"Advantages and limitations of ultrasound as a screening test for ovarian cancer","volume":"13","author":"Koutras","year":"2023","journal-title":"Diagnostics"},{"key":"bpexad5db1bib6","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1038\/nature14248","article-title":"Integrative analysis of 111 reference human epigenomes","volume":"518","author":"Kundaje","year":"2015","journal-title":"Nature"},{"key":"bpexad5db1bib7","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1159\/000329005","article-title":"Advantages and disadvantages of mammography screening","volume":"6","author":"Heywang-K\u00f6brunner","year":"2011","journal-title":"Breast Care"},{"key":"bpexad5db1bib8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2022\/8565490","article-title":"The accuracy of electrical impedance tomography for breast cancer detection: a systematic review and meta-analysis","volume":"2022","author":"Rezanejad Gatabi","year":"2022","journal-title":"Breast J."},{"key":"bpexad5db1bib9","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1088\/0967-3334\/22\/1\/302","article-title":"A 3D electrical impedance tomography (EIT) system for breast cancer detection","volume":"22","author":"Cherepenin","year":"2001","journal-title":"Physiol. Meas."},{"key":"bpexad5db1bib10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2022\/8565490","article-title":"The accuracy of electrical impedance tomography for breast cancer detection: a systematic review and meta-analysis","volume":"2022","author":"Rezanejad Gatabi","year":"2022","journal-title":"Breast J."},{"key":"bpexad5db1bib11","doi-asserted-by":"publisher","first-page":"5595","DOI":"10.7314\/APJCP.2015.16.14.5595","article-title":"Electrical impedance tomography as a primary screening technique for breast cancer detection","volume":"16","author":"Akhtari-Zavare","year":"2015","journal-title":"Asian Pacific Journal of Cancer Prevention"},{"key":"bpexad5db1bib12","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.3390\/s23031182","article-title":"Electrical impedance tomography: from the traditional design to the novel frontier of wearables","volume":"23","author":"Pennati","year":"2023","journal-title":"Sensors"},{"key":"bpexad5db1bib13","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2021.109401","article-title":"Electrical conductivity effect on the performance evaluation of EIT systems: a review","volume":"178","author":"da Mata","year":"2021","journal-title":"Measurement"},{"key":"bpexad5db1bib14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2023.3282295","article-title":"Multinode electrical impedance tomography (mn EIT) throughout Whole-body electrical muscle stimulation (wb EMS)","volume":"72","author":"Sejati","year":"2023","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"bpexad5db1bib15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2022.3166796","article-title":"Multifrequency electrical impedance tomography with ratiometric preprocessing for imaging human body compartments","volume":"71","author":"Ogawa","year":"2022","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"bpexad5db1bib16","doi-asserted-by":"publisher","first-page":"14336","DOI":"10.1109\/JSEN.2022.3181052","article-title":"gastric electrical impedance tomography (gEIT) based on a 3D jacobian matrix and dual-step fuzzy clustering post-processing","volume":"22","author":"Darma","year":"2022","journal-title":"IEEE Sens. J"},{"key":"bpexad5db1bib17","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6501\/abd96e","article-title":"Albumin diffusivity coefficient estimation in imitated porous structure of interstitial space by integration of albumin diffusion model (ADM) to electrical impedance tomography (EIT)","volume":"32","author":"Dharma","year":"2021","journal-title":"Meas. Sci. Technol."},{"key":"bpexad5db1bib18","doi-asserted-by":"publisher","first-page":"045013","DOI":"10.1088\/2057-1976\/acd4c6","article-title":"Sodium concentration imaging in dermis layer by square-wave open electrical impedance tomography (SW-oEIT) with spatial voltage thresholding (SVT)","volume":"9","author":"Rifai","year":"2023","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexad5db1bib19","doi-asserted-by":"publisher","first-page":"66","DOI":"10.5617\/jeb.3350","article-title":"Spatial resolution in electrical impedance tomography: a topical review","volume":"8","author":"Chitturi","year":"2019","journal-title":"J. Electr. Bioimpedance"},{"key":"bpexad5db1bib20","doi-asserted-by":"publisher","DOI":"10.1016\/j.electacta.2019.135316","article-title":"The Gaussian process distribution of relaxation times: a machine learning tool for the analysis and prediction of electrochemical impedance spectroscopy data","volume":"331","author":"Liu","year":"2020","journal-title":"Electrochim. Acta"},{"key":"bpexad5db1bib21","doi-asserted-by":"publisher","first-page":"1917","DOI":"10.1149\/1.2069522","article-title":"Measurement models for electrochemical impedance spectroscopy: I . demonstration of applicability","volume":"139","author":"Agarwal","year":"1992","journal-title":"J. Electrochem. Soc."},{"key":"bpexad5db1bib22","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1016\/j.electacta.2015.09.097","article-title":"Influence of the discretization methods on the distribution of relaxation times deconvolution: implementing radial basis functions with DRTtools","volume":"184","author":"Wan","year":"2015","journal-title":"Electrochim. Acta"},{"key":"bpexad5db1bib23","doi-asserted-by":"publisher","first-page":"8062","DOI":"10.3390\/s23198062","article-title":"Metal particle detection by integration of a generative adversarial network and electrical impedance tomography (GAN-EIT) for a wet-type gravity vibration separator","volume":"23","author":"Ibrahim","year":"2023","journal-title":"Sensors"},{"key":"bpexad5db1bib24","doi-asserted-by":"publisher","first-page":"9469","DOI":"10.1109\/JSEN.2020.2987534","volume":"20","author":"Darma","year":"2020"},{"key":"bpexad5db1bib25","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1137\/0914086","article-title":"The use of the L-curve in the regularization of discrete Ill-posed problems","volume":"14","author":"Hansen","year":"1993","journal-title":"SIAM J. Sci. Comput."},{"key":"bpexad5db1bib26","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1137\/0152060","article-title":"Existence and uniqueness for electrode models for electric current computed tomography","volume":"52","author":"Somersalo","year":"1992","journal-title":"SIAM J. Appl. Math."},{"key":"bpexad5db1bib27","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1177\/153303460800700404","article-title":"The use of tissue electrical characteristics for breast cancer detection: a perspective review","volume":"7","author":"Ng","year":"2008","journal-title":"Technol. Cancer Res. Treat."},{"key":"bpexad5db1bib28","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.tranon.2015.04.005","article-title":"Quantification of regional breast density in four quadrants using 3D MRI\u2014a pilot study","volume":"8","author":"Fwu","year":"2015","journal-title":"Transl. Oncol."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5db1","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5db1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5db1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5db1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5db1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5db1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5db1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5db1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T15:41:22Z","timestamp":1749915682000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad5db1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,11]]},"references-count":28,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2024,7,11]]},"published-print":{"date-parts":[[2024,9,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad5db1","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,11]]},"assertion":[{"value":"Detection of invasive ductal carcinoma in quadrant breast areas by electrical impedance tomography implemented with gaussian relaxation-time distribution (EIT-GRTD)","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-03-24","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-07-02","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-07-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}