{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T22:12:59Z","timestamp":1766182379533,"version":"3.37.3"},"reference-count":22,"publisher":"IOP Publishing","issue":"6","license":[{"start":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T00:00:00Z","timestamp":1726099200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T00:00:00Z","timestamp":1726099200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Objective<\/jats:italic>. Cone beam CT (CBCT) typically has severe image artifacts and inaccurate HU values, which limits its application in radiation medicines. Scholars have proposed the use of cycle consistent generative adversarial network (Cycle-GAN) to address these issues. However, the generation quality of Cycle-GAN needs to be improved. This issue is exacerbated by the inherent size discrepancies between pelvic CT scans from different patients, as well as varying slice positions within the same patient, which introduce a scaling problem during training. <jats:italic>Approach<\/jats:italic>. We introduced the Enhanced Edge and Mask (EEM) approach in our structural constraint Cycle-EEM-GAN. This approach is designed to not only solve the scaling problem but also significantly improve the generation quality of the synthetic CT images. Then data from sixty pelvic patients were used to investigate the generation of synthetic CT (sCT) from CBCT. <jats:italic>Main results.<\/jats:italic> The mean absolute error (MAE), the root mean square error (RMSE), the peak signal to noise ratio (PSNR), the structural similarity index (SSIM), and spatial nonuniformity (SNU) are used to assess the quality of the sCT generated from CBCT. Compared with CBCT images, the MAE improved from 53.09 to 37.74, RMSE from 185.22 to 146.63, SNU from 0.38 to 0.35, PSNR from 24.68 to 32.33, SSIM from 0.624 to 0.981. Also, the Cycle-EEM-GAN outperformed Cycle-GAN in terms of visual evaluation and loss. <jats:italic>Significance.<\/jats:italic> Cycle-EEM-GAN has improved the quality of CBCT images, making the structural details clear while prevents image scaling during the generation process, so that further promotes the application of CBCT in radiotherapy.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad7607","type":"journal-article","created":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T12:01:58Z","timestamp":1726142518000},"page":"065016","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Synthetic CT generation from CBCT based on structural constraint cycle-EEM-GAN"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-1234-0239","authenticated-orcid":true,"given":"Qianhong","family":"Lu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-5079-3678","authenticated-orcid":true,"given":"Feng","family":"Luo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juntian","family":"Shi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2364-8200","authenticated-orcid":true,"given":"Kunyuan","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2024,9,12]]},"reference":[{"key":"bpexad7607bib1","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1038\/nrc2288","article-title":"Innovations in image-guided radiotherapy","volume":"7","author":"Verellen","year":"2007","journal-title":"Nat. Rev. Cancer"},{"key":"bpexad7607bib2","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1016\/S0360-3016(02)02884-5","article-title":"Flat-panel cone-beam computed tomography for image-guided radiation therapy","volume":"53","author":"Jaffray","year":"2002","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexad7607bib3","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.canrad.2006.05.012","article-title":"Clinical application of image-guided radiotherapy, IGRT (on the varian OBI platform)","volume":"10","author":"Sorcini","year":"2006","journal-title":"Cancer\/Radioth\u00e9rapie"},{"key":"bpexad7607bib4","doi-asserted-by":"publisher","first-page":"122","DOI":"10.5114\/jcb.2016.59282","article-title":"Image guided radiation therapy boost in combination with high-dose-rate intracavitary brachytherapy for the treatment of cervical cancerJ. Contemp","volume":"8","author":"Wang","year":"2016","journal-title":"Brachyther."},{"key":"bpexad7607bib5","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1002\/mp.13963","article-title":"Visual enhancement of cone-beam CT byuse of CycleGAN","volume":"47","author":"Kida","year":"2020","journal-title":"Med. Phys."},{"key":"bpexad7607bib6","doi-asserted-by":"publisher","first-page":"3998","DOI":"10.1002\/mp.13656","article-title":"Paired cycle-GAN-based image correction for quantitative cone-beam computed tomography","volume":"46","author":"Harms","year":"2019","journal-title":"Med. Phys."},{"key":"bpexad7607bib7","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab22f9","article-title":"Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using CycleGAN for adaptive radiation therapy","volume":"64","author":"Liang","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"bpexad7607bib8","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1002\/mp.13978","article-title":"Synthetic CT generation from CBCT images via deep learning","volume":"47","author":"Chen","year":"2020","journal-title":"Med. Phys."},{"key":"bpexad7607bib9","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac01b6","article-title":"Synthetic CT generation from CBCT images via unsupervised deep learning","volume":"66","author":"Chen","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"bpexad7607bib10","doi-asserted-by":"publisher","first-page":"4437","DOI":"10.1002\/mp.12385","article-title":"Optimal combination of anti-scatter grids and software correction for CBCT imaging","volume":"44","author":"Stankovic","year":"2017","journal-title":"Med. Phys."},{"key":"bpexad7607bib11","doi-asserted-by":"publisher","first-page":"2258","DOI":"10.1118\/1.3130047","article-title":"Scatter correction for cone-beam CT in radiation therapy","volume":"36","author":"Zhu","year":"2009","journal-title":"Med. Phys."},{"key":"bpexad7607bib12","doi-asserted-by":"publisher","first-page":"3567","DOI":"10.1088\/0031-9155\/60\/9\/3567","article-title":"A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy","volume":"60","author":"Xu","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"bpexad7607bib13","first-page":"1","article-title":"Deep residual learning in CT physics: scatter correction for spectral CT","author":"Xu","year":"2017"},{"key":"bpexad7607bib14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ijrobp.2017.06.011","article-title":"On the fuzziness of machine learning, neural networks, and artificial intelligence in radiation oncology","volume":"100","author":"El Naqa","year":"2018","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexad7607bib15","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab4d8c","article-title":"CBCT correction using a cycle-consistent generative adversarial network and unpaired training to enable photon and proton dose calculation","volume":"64","author":"Kurz","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"bpexad7607bib16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-80803-2","article-title":"Cone-beam CT image quality improvement using cycle-deblur consistent adversarial networks(cycle-deblur GAN) for chest CT imaging in breast cancer patients","volume":"11","author":"Tien","year":"2021","journal-title":"Sci Rep."},{"key":"bpexad7607bib17","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac7b0a","article-title":"Improving cone-beam CT quality using a cycle-residual connection with a dilated convolution-consistent generative adversarial network","volume":"67","author":"Deng","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"bpexad7607bib18","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2019.01191","article-title":"Dosimetric impact of interfractional variations for post-prostatectomy radiotherapy to the prostatic fossa\u2014relevance for the frequency of position verification imaging and treatment adaptation","volume":"9","author":"Splinter","year":"2019","journal-title":"Front. Oncol."},{"key":"bpexad7607bib19","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1049\/ipr2.12342","article-title":"ESA-CycleGAN: Edge feature and self-attention based cycle-consistent generative adversarial network for style transfer","volume":"16","author":"Wang","year":"2022","journal-title":"IET Image Process"},{"key":"bpexad7607bib20","doi-asserted-by":"publisher","first-page":"4249","DOI":"10.1109\/TMI.2020.3015379","article-title":"Unsupervised MR-to-CT synthesis using structure-constrained CycleGAN","volume":"39","author":"Yang","year":"2020","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexad7607bib21","first-page":"2986","article-title":"CyEDA: cycle-object edge consistency domain adaptation","author":"Beh","year":"2022"},{"key":"bpexad7607bib22","first-page":"2223","article-title":"Unpaired image-to-image translation using cycle-consistent adversarial networks","author":"Zhu","year":"2017"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad7607","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad7607\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad7607\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad7607\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T12:02:03Z","timestamp":1726142523000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad7607"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,12]]},"references-count":22,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024,9,12]]},"published-print":{"date-parts":[[2024,11,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad7607","relation":{},"ISSN":["2057-1976"],"issn-type":[{"type":"electronic","value":"2057-1976"}],"subject":[],"published":{"date-parts":[[2024,9,12]]},"assertion":[{"value":"Synthetic CT generation from CBCT based on structural constraint cycle-EEM-GAN","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-04-23","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-09-02","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-09-12","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}