{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T17:46:32Z","timestamp":1790444792907,"version":"4.1.0"},"reference-count":32,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2025,2,11]],"date-time":"2025-02-11T00:00:00Z","timestamp":1739232000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2025,2,11]],"date-time":"2025-02-11T00:00:00Z","timestamp":1739232000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Hassan First University","award":["FP202006"],"award-info":[{"award-number":["FP202006"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2025,3,31]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This study presents the design and validation of a neonatal head phantom using innovative heterogeneous composite materials customized to replicate the x-ray attenuation properties of neonatal cranial structures. Analysis of Hounsfield Unit (HU) data from 338 neonatal head CT scans informed the design of epoxy resin-based composites with additives such as sodium bicarbonate, fumed silica, and acetone to simulate bone, brain matter, cerebrospinal fluid (CSF) and hyperdense abnormalities. The cranial bone substitute (60% epoxy resin, 40% sodium bicarbonate) achieved a density of 1.60 g cm<jats:sup>\u22123<\/jats:sup>, with HU values (574.67\u2013608.04) closely matching clinical ranges. Brain matter (95% epoxy resin, 5% acetone) achieved HU values (35.27\u201343.61), aligning with clinical means, while the CSF-equivalent material (80% epoxy resin, 15% fumed silica, 5% acetone) matched neonatal CSF HU values (14.53\u201317.02). A mass substitute for hyperdense abnormalities exhibited HU values (56.16\u201361.07), enabling differentiation from normal brain. Validation included Monte Carlo simulations and experimental CT imaging, showing close agreement in linear attenuation coefficients, with deviations below 11% across energy levels. Mass attenuation coefficients from simulations and XCOM software were consistent, with deviations under 0.7%, confirming the materials dosimetric reliability. The phantom, with a cylindrical geometry (9 cm diameter, 10 cm length), provides accurate attenuation properties across 80\u2013120 kVp energy levels, with deviations below 5% between experimental CT numbers and simulation data. This phantom offers a robust platform for neonatal imaging research, enabling impactful dose optimization and imaging protocol adjustment and supports improved diagnostic accuracy in pediatric imaging.<\/jats:p>","DOI":"10.1088\/2057-1976\/adb15c","type":"journal-article","created":{"date-parts":[[2025,2,3]],"date-time":"2025-02-03T22:48:13Z","timestamp":1738622893000},"page":"025031","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Study of attenuation characteristics for novel neonatal head phantom in diagnostic radiology using Monte Carlo simulations and experiments"],"prefix":"10.1088","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-1530-4837","authenticated-orcid":true,"given":"Hamza","family":"Sekkat","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-5050-748X","authenticated-orcid":true,"given":"Khallouqi","family":"Abdellah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"El Rhazouani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5030-7444","authenticated-orcid":true,"given":"Youssef","family":"Madkouri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdellah","family":"Halimi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,2,11]]},"reference":[{"key":"bpexadb15cbib1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/10420150.2024.2391747","article-title":"Assessing the influence of dose modulation on water equivalent diameter estimation in pediatric head CT imaging","author":"Sekkat","year":"2024","journal-title":"Radiat. Eff. Defects Solids"},{"key":"bpexadb15cbib2","doi-asserted-by":"publisher","first-page":"2327","DOI":"10.1007\/s11668-024-02025-2","article-title":"Risk management and failure analysis in diagnostic x-ray equipment: a comprehensive analysis and novel approaches for failure prevention and system reliability","volume":"24","author":"Sekkat","year":"2024","journal-title":"J. Fail. Anal. and Preven."},{"key":"bpexadb15cbib3","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2024.112214","article-title":"Helical to wide volume acquisition in lumbar spine CT: structures scoring based analysis","volume":"226","author":"Madkouri","year":"2025","journal-title":"Radiat. Phys. Chem."},{"key":"bpexadb15cbib4","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1051\/radiopro\/2024017","article-title":"Characterizing pediatric head patient size in moroccan population: establishing age-dependent relationships for accurate CT dose estimation","volume":"59","author":"Sekkat","year":"2024","journal-title":"Radioprotection"},{"key":"bpexadb15cbib5","doi-asserted-by":"publisher","first-page":"1295","DOI":"10.1080\/10420150.2024.2335240","article-title":"Advancing pediatric head CT dose prediction: correlating patient size metrics with AP and LAT dimensions in moroccan population","volume":"179","author":"Sekkat","year":"2024","journal-title":"Radiat. Eff. Defects Solids"},{"key":"bpexadb15cbib6","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1093\/jnci\/djy104","article-title":"Radiation exposure from pediatric CT scans and subsequent cancer risk in the Netherlands","volume":"111","author":"Meulepas","year":"2019","journal-title":"JNCI: Journal of the National Cancer Institute"},{"key":"bpexadb15cbib7","doi-asserted-by":"publisher","first-page":"1144","DOI":"10.3390\/cancers13051144","article-title":"Risk of second primary malignancies among patients with early gastric cancer exposed to recurrent computed tomography scans","volume":"13","author":"Kim","year":"2021","journal-title":"Cancers"},{"key":"bpexadb15cbib8","doi-asserted-by":"publisher","DOI":"10.3238\/arztebl.2011.0407","article-title":"Radiation protection in pediatric radiology","author":"Alzen","year":"2011","journal-title":"Deutsches \u00c4rzteblatt international 108 407\u201314"},{"key":"bpexadb15cbib9","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1148\/radiology.210.3.r99mr05645","article-title":"Radiation effective doses to patients undergoing abdominal CT examinations","volume":"210","author":"Ware","year":"1999","journal-title":"Radiology"},{"key":"bpexadb15cbib10","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1088\/0952-4746\/11\/3\/006","article-title":"The 1990 recommendations of the international commission on radiological protection","volume":"11","author":"Vennart","year":"1991","journal-title":"J. Radiol. Prot."},{"key":"bpexadb15cbib11","doi-asserted-by":"publisher","first-page":"2424","DOI":"10.1118\/1.2921829","article-title":"Monte Carlo evaluation of in infinitely long cylinders of water, polyethylene and PMMA with diameters from to","volume":"35","author":"Zhou","year":"2008","journal-title":"Med. Phys."},{"key":"bpexadb15cbib12","doi-asserted-by":"publisher","first-page":"3399","DOI":"10.1118\/1.2757084","article-title":"Experimental validation of a versatile system of CT dosimetry using a conventional ion chamber: beyond","volume":"34","author":"Dixon","year":"2007","journal-title":"Med. Phys."},{"key":"bpexadb15cbib13","doi-asserted-by":"publisher","first-page":"2515","DOI":"10.1016\/j.nimb.2010.05.051","article-title":"Evaluation of tissue-equivalent materials to be used as human brain tissue substitute in dosimetry for diagnostic radiology","volume":"268","author":"Ferreira","year":"2010","journal-title":"Nucl. Instrum. Methods Phys. Res., Sect. B"},{"key":"bpexadb15cbib14","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1093\/rpd\/nci701","article-title":"The ICRU (international commission on radiation units and measurements): its contribution to dosimetry in diagnostic and interventional radiology","volume":"117","author":"Wambersie","year":"2005","journal-title":"Radiat. Prot. Dosim."},{"key":"bpexadb15cbib15","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2019.108553","article-title":"Reprint of \u2018x-ray spectrometry applied for determination of linear attenuation coefficient of tissue-equivalent materials","volume":"167","author":"Frimaio","year":"2020","journal-title":"Radiat. Phys. Chem."},{"key":"bpexadb15cbib16","doi-asserted-by":"crossref","DOI":"10.6028\/NIST.IR.5632","article-title":"Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest","author":"Hubbell","year":"1995"},{"key":"bpexadb15cbib17","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2023.111042","article-title":"Evaluation of fetal dose during pelvimetry CT scan procedure by Monte Carlo using GATE","volume":"210","author":"Aabid","year":"2023","journal-title":"Radiat. Phys. Chem."},{"key":"bpexadb15cbib18","doi-asserted-by":"publisher","DOI":"10.1016\/j.zemedi.2023.07.007","article-title":"Radiation-induced double-strand breaks by internal ex vivo irradiation of lymphocytes: validation of a Monte Carlo simulation model using GATE and Geant4-DNA","author":"Salas-Ramirez","year":"2023","journal-title":"Zeitschrift f\u00fcr Medizinische Physik"},{"key":"bpexadb15cbib19","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.ejmp.2019.08.020","article-title":"Size-specific dose estimations for pediatric chest, abdomen\/pelvis and head CT scans with the use of GATE","volume":"65","author":"Kostou","year":"2019","journal-title":"Physica Med."},{"key":"bpexadb15cbib20","doi-asserted-by":"publisher","DOI":"10.1016\/j.pnucene.2022.104281","article-title":"Monte Carlo simulation of the mass attenuation coefficient and effective atomic number of the Eremurus-Rhizophora ssp. particleboard phantom at the mammography energy range","volume":"149","author":"Tousi","year":"2022","journal-title":"Prog. Nucl. Energy"},{"key":"bpexadb15cbib21","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2024.111702","article-title":"Comparing tissue-equivalent properties of polyester and epoxy resins with PMMA material using gate\/Geant4 simulation toolkit","volume":"220","author":"Khallouqi","year":"2024","journal-title":"Radiat. Phys. Chem."},{"key":"bpexadb15cbib22","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.nimb.2015.09.003","article-title":"Determination of the effective sample thickness via radiative capture","volume":"362","author":"Hurst","year":"2015","journal-title":"Nucl. Instrum. Methods Phys. Res., Sect. B"},{"key":"bpexadb15cbib23","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.1118\/1.1576952","article-title":"A new look at CT dose measurement: beyond CTDI","volume":"30","author":"Dixon","year":"2003","journal-title":"Med. Phys."},{"key":"bpexadb15cbib24","doi-asserted-by":"publisher","first-page":"3331","DOI":"10.1088\/0031-9155\/51\/14\/003","article-title":"MAX06 and FAX06: update of two adult human phantoms for radiation protection dosimetry","volume":"51","author":"Kramer","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"bpexadb15cbib25","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.net.2021.08.008","article-title":"Organ dose conversion coefficients in CT scans for Korean adult males and females","volume":"54","author":"Lee","year":"2022","journal-title":"Nuclear Engineering and Technology"},{"key":"bpexadb15cbib26","doi-asserted-by":"publisher","first-page":"45","DOI":"10.4103\/0971-6203.177287","article-title":"Comparison of computed tomography dose index in polymethyl methacrylate and nylon dosimetry phantoms","volume":"41","author":"Sookpeng","year":"2016","journal-title":"J. Med. Phys."},{"key":"bpexadb15cbib27","author":"Suetens","year":"2017"},{"key":"bpexadb15cbib28","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.1118\/1.4906178","article-title":"Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry","volume":"42","author":"Bostani","year":"2015","journal-title":"Med. Phys."},{"key":"bpexadb15cbib29","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.nima.2016.06.125","article-title":"Recent developments in Geant4","volume":"835","author":"Allison","year":"2016","journal-title":"Nucl. Instrum. Methods Phys. Res., Sect. A"},{"key":"bpexadb15cbib30","author":"International Atomic Energy Agency","year":"1998"},{"key":"bpexadb15cbib31","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.radphyschem.2015.03.030","article-title":"Determination of tissue equivalent materials of a physical 8-year-old phantom for use in computed tomography","volume":"112","author":"Akhlaghi","year":"2015","journal-title":"Radiat. Phys. Chem."},{"key":"bpexadb15cbib32","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2019.108507","article-title":"Mass attenuation coefficients, effective atomic numbers and electron densities of some contrast agents for computed tomography","volume":"166","author":"Al-Buriahi","year":"2020","journal-title":"Radiat. Phys. Chem."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adb15c","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adb15c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adb15c","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adb15c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adb15c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adb15c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adb15c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adb15c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,11]],"date-time":"2025-02-11T14:17:25Z","timestamp":1739283445000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adb15c"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,11]]},"references-count":32,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,2,11]]},"published-print":{"date-parts":[[2025,3,31]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/adb15c","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,11]]},"assertion":[{"value":"Study of attenuation characteristics for novel neonatal head phantom in diagnostic radiology using Monte Carlo simulations and experiments","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-12-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-02-03","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-02-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}