{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T15:22:16Z","timestamp":1778253736240,"version":"3.51.4"},"reference-count":28,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T00:00:00Z","timestamp":1748304000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T00:00:00Z","timestamp":1748304000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2025,7,31]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Minibeam radiation therapy (MBRT) is a promising treatment technique in the early stages of clinical use. In this work, two hexagonal minibeam collimators were designed, fabricated, and validated using film measurements and Monte Carlo simulations. Film and Monte Carlo results demonstrated strong agreement, with the greatest agreement near the beam central axis. One of the previously validated MBRT collimators was then modified to allow for dose calculations on a mouse cone beam computed tomography (CBCT) dataset, and a MBRT dose distribution was preserved in the animal dataset. This validated system can be used in future cell and small animal studies to further explore MBRT in a preclinical setting.<\/jats:p>","DOI":"10.1088\/2057-1976\/adcf2c","type":"journal-article","created":{"date-parts":[[2025,4,22]],"date-time":"2025-04-22T22:47:57Z","timestamp":1745362077000},"page":"047001","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Design and validation of a minibeam treatment delivery system for use with a radiation therapy research platform"],"prefix":"10.1088","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6435-5650","authenticated-orcid":true,"given":"Steven","family":"Herchko","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9796-8576","authenticated-orcid":true,"given":"Sridhar","family":"Yaddanapudi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C-K Chris","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2025,5,27]]},"reference":[{"key":"bpexadcf2cbib1","first-page":"2314","article-title":"Zur r\u00f6ntgentiefentherapie mit massendosen (conceming deep roentgen therapy with massive doses)","volume":"56","author":"Kohler","year":"1909","journal-title":"MMW"},{"key":"bpexadcf2cbib2","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1148\/58.3.338","article-title":"Clinical experience with irradiation through a grid","volume":"58","author":"Marks","year":"1952","journal-title":"Radiology"},{"key":"bpexadcf2cbib3","doi-asserted-by":"publisher","DOI":"10.1017\/erm.2021.34","article-title":"Divide and conquer: spatially fractionated radiation therapy","volume":"24","author":"Prezado","year":"2022","journal-title":"Expert Rev. Mol. Med."},{"key":"bpexadcf2cbib4","doi-asserted-by":"publisher","first-page":"1423","DOI":"10.1016\/j.ijrobp.2024.06.035","article-title":"Minibeam radiation therapy treatment (MBRT): commissioning and first clinical implementation","volume":"120","author":"Grams","year":"2024","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexadcf2cbib5","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1016\/j.ijrobp.2015.10.020","article-title":"Proton minibeam radiation therapy reduces side effects in an in vivo mouse ear model","volume":"95","author":"Girst","year":"2016","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexadcf2cbib6","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-14786-y","article-title":"Proton minibeam radiation therapy spares normal rat brain: long-term clinical, radiological and histopathological analysis","volume":"7","author":"Prezado","year":"2017","journal-title":"Sci. Rep."},{"key":"bpexadcf2cbib7","doi-asserted-by":"publisher","first-page":"3366","DOI":"10.3390\/ijms23063366","article-title":"Radiobiological and treatment-related aspects of spatially fractionated radiotherapy","volume":"23","author":"Moghaddasi","year":"2022","journal-title":"Int. J. Mol. Sci."},{"key":"bpexadcf2cbib8","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0229053","article-title":"Conventional dose rate spatially-fractionated radiation therapy (SFRT) treatment response and its association with dosimetric parameters\u2014a preclinical study in a fischer 344 rat model","volume":"15","author":"Rivera","year":"2020","journal-title":"PLoS One"},{"key":"bpexadcf2cbib9","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac508c","article-title":"An investigation of kV mini-GRID spatially fractionated radiation therapy: dosimetry and preclinical trial","volume":"67","author":"Johnson","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"bpexadcf2cbib10","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2024.103420","article-title":"Preclinical photon minibeam radiotherapy using a custom collimator: dosimetry characterization and preliminary in-vivo results on a glioma model","volume":"124","author":"Koksal Akbas","year":"2024","journal-title":"Physica Med."},{"key":"bpexadcf2cbib11","doi-asserted-by":"publisher","first-page":"5222","DOI":"10.1002\/mp.16432","article-title":"Development and characterization of a versatile mini-beam collimator for pre-clinical photon beam irradiation","volume":"50","author":"Stengl","year":"2023","journal-title":"Med. Phys."},{"key":"bpexadcf2cbib12","doi-asserted-by":"publisher","first-page":"6991","DOI":"10.1088\/0031-9155\/60\/17\/6991","article-title":"Medical linear accelerator mounted mini-beam collimator: design, fabrication and dosimetric characterization","volume":"60","author":"Cranmer-Sargison","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"bpexadcf2cbib13","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1667\/RADE-21-00093.1","article-title":"Is mini beam ready for human trials? results of randomized study of treating de-novo brain tumors in canines using linear accelerator generated mini beams","volume":"198","author":"Kundapur","year":"2022","journal-title":"Radiat. Res."},{"key":"bpexadcf2cbib14","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/j.semradonc.2024.04.003","article-title":"The story behind the first mini-beam photon radiation treatment: what is the mini-beam and why is it such an advance?","volume":"34","author":"Kundapur","year":"2024","journal-title":"Semin. Radiat. Oncol."},{"key":"bpexadcf2cbib15","doi-asserted-by":"publisher","first-page":"868","DOI":"10.1118\/1.1374247","article-title":"AAPM protocol for 40\u2013300 kV x-ray beam dosimetry in radiotherapy and radiobiology","volume":"28","author":"Ma","year":"2001","journal-title":"Med. Phys."},{"key":"bpexadcf2cbib16","doi-asserted-by":"publisher","first-page":"6339","DOI":"10.1118\/1.4754797","article-title":"An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan","volume":"39","author":"Lewis","year":"2012","journal-title":"Med. Phys."},{"key":"bpexadcf2cbib17","author":"Ashland","year":"2016"},{"key":"bpexadcf2cbib18","doi-asserted-by":"publisher","first-page":"6818","DOI":"10.1118\/1.4758060","article-title":"TOPAS: an innovative proton monte carlo platform for research and clinical applications","volume":"39","author":"Perl","year":"2012","journal-title":"Med. Phys."},{"key":"bpexadcf2cbib19","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.ejmp.2020.03.019","article-title":"The TOPAS tool for particle simulation, a monte carlo simulation tool for physics, biology and clinical research","volume":"72","author":"Faddegon","year":"2020","journal-title":"Physica Med."},{"key":"bpexadcf2cbib20","doi-asserted-by":"publisher","first-page":"N433","DOI":"10.1088\/0031-9155\/54\/19\/N01","article-title":"SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes","volume":"54","author":"Poludniowski","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"bpexadcf2cbib21","doi-asserted-by":"publisher","first-page":"2175","DOI":"10.1118\/1.2734726","article-title":"Calculation of x-ray spectra emerging from an x-ray tube: II. X-ray production and filtration in x-ray targets","volume":"34","author":"Poludniowski","year":"2007","journal-title":"Med. Phys."},{"key":"bpexadcf2cbib22","doi-asserted-by":"publisher","first-page":"2164","DOI":"10.1118\/1.2734725","article-title":"Calculation of x-ray spectra emerging from an x-ray tube: I. Electron penetration characteristics in x-ray targets","volume":"34","author":"Poludniowski","year":"2007","journal-title":"Med. Phys."},{"key":"bpexadcf2cbib23","doi-asserted-by":"publisher","first-page":"2745","DOI":"10.1118\/1.1517611","article-title":"History by history statistical estimators in the BEAM code system","volume":"29","author":"Walters","year":"2002","journal-title":"Med. Phys."},{"key":"bpexadcf2cbib24","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1088\/0031-9155\/45\/2\/314","article-title":"Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions","volume":"45","author":"Schneider","year":"2000","journal-title":"Phys. Med. Biol."},{"key":"bpexadcf2cbib25","doi-asserted-by":"publisher","first-page":"52017","DOI":"10.3791\/52017","article-title":"Creating anatomically accurate and reproducible intracranial xenografts of human brain tumors","volume":"91","author":"Pierce","year":"2014","journal-title":"Journal of Visualized Experiments."},{"key":"bpexadcf2cbib26","doi-asserted-by":"publisher","first-page":"3625","DOI":"10.3390\/cancers14153625","article-title":"Should peak dose be used to prescribe spatially fractionated radiation therapy?-a review of preclinical studies","volume":"14","author":"Fernandez-Palomo","year":"2022","journal-title":"Cancers."},{"key":"bpexadcf2cbib27","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-14786-y","article-title":"Transfer of minibeam radiation therapy into a cost-effective equipment for radiobiological studies: a proof of concept","volume":"7","author":"Prezado","year":"2017","journal-title":"Sci. Rep."},{"key":"bpexadcf2cbib28","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa926b","article-title":"Minibeam radiotherapy with small animal irradiators; in-vitro and in-vivo feasibility studies","volume":"62","author":"Bazyar","year":"2017","journal-title":"Phys. Med. Biol."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adcf2c","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adcf2c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adcf2c","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adcf2c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adcf2c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adcf2c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adcf2c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adcf2c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T11:40:17Z","timestamp":1748346017000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adcf2c"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,27]]},"references-count":28,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,5,27]]},"published-print":{"date-parts":[[2025,7,31]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/adcf2c","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,27]]},"assertion":[{"value":"Design and validation of a minibeam treatment delivery system for use with a radiation therapy research platform","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-10-31","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-04-22","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-05-27","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}