{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T06:47:10Z","timestamp":1764226030628,"version":"3.40.5"},"reference-count":40,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T00:00:00Z","timestamp":1747612800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T00:00:00Z","timestamp":1747612800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2025,5,30]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This study aims to investigate the feasibility of a single general model to synthesize CT images across body sites, thorax, abdomen, and pelvis, to support treatment planning for MRI-only radiotherapy. A total of 157 patients who received MRI-guided radiation therapy in the thorax, abdomen, and pelvis on a 0.35T MRIdian Linac were included. A subset of 122 cases were used for model training and the remaining 35 cases were used for model validation. All patient datasets had semi-paired CT-simulation image and 0.35T MR image acquired using TrueFISP. A conditional generative adversarial network with a multi-planar method was used to generate synthetic CT images from 0.35T MR images. The effect of preprocessing methods (with and without bias field corrections) on the quality of synthetic CT was evaluated and found to be insignificant. The general models trained on all cases performed comparably to the site-specific models trained on individual body sites. For all models, the peak signal-to-noise ratios ranged from 31.7 to 34.9 and the structural index similarity measures ranged from 0.9547 to 0.9758. For the datasets with bias field corrections, the mean-absolute-errors in HU (general model versus site-specific model) were 49.7\u00a0\u00b1\u00a09.4 versus 49.5\u00a0\u00b1\u00a08.9, 48.7\u00a0\u00b1\u00a07.6 versus 43\u00a0\u00b1\u00a07.8 and 32.8\u00a0\u00b1\u00a05.5 versus 31.8\u00a0\u00b1\u00a05.3 for the thorax, abdomen, and pelvis, respectively. When comparing plans between synthetic CTs and ground truth CTs, the dosimetric difference was on average less than 0.5% (0.2 Gy) for target coverage and less than 2.1% (0.4 Gy) for organ-at-risk metrics for all body sites with either the general or specific models. Synthetic CT plans showed good agreement with mean gamma pass rates of &gt;94% and &gt;99% for 1%\/1 mm and 2%\/2 mm, respectively. This study has demonstrated the feasibility of using a general model for multiple body sites and the potential of using synthetic CT to support an MRI-guided radiotherapy workflow.<\/jats:p>","DOI":"10.1088\/2057-1976\/add26b","type":"journal-article","created":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T08:12:54Z","timestamp":1746087174000},"page":"035028","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Feasibility study of a general model for synthetic CT generation in MRI-guided extracranial radiotherapy"],"prefix":"10.1088","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6947-5878","authenticated-orcid":true,"given":"Shu-Hui","family":"Hsu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5285-533X","authenticated-orcid":true,"given":"Zhaohui","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7800-6053","authenticated-orcid":true,"given":"Yue-Houng","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dianne","family":"Ferguson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ritchell","family":"van Dams","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raymond H","family":"Mak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan E","family":"Leeman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atchar","family":"Sudhyadhom","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2025,5,19]]},"reference":[{"key":"bpexadd26bbib1","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1186\/s13014-023-02336-y","article-title":"Comparison of four synthetic CT generators for brain and prostate MR-only workflow in radiotherapy","volume":"18","author":"Autret","year":"2023","journal-title":"Radiat. Oncol."},{"key":"bpexadd26bbib2","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.radonc.2020.11.027","article-title":"Multicentre, deep learning, synthetic-CT generation for ano-rectal MR-only radiotherapy treatment planning","volume":"156","author":"Bird","year":"2021","journal-title":"Radiother. Oncol."},{"key":"bpexadd26bbib3","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2023.110052","article-title":"Deep learning MRI-only synthetic-CT generation for pelvis, brain and head and neck cancers","volume":"191","author":"Bird","year":"2023","journal-title":"Radiother. Oncol."},{"key":"bpexadd26bbib4","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.ejmp.2021.07.027","article-title":"Deep learning methods to generate synthetic CT from MRI in radiotherapy: a literature review","volume":"89","author":"Boulanger","year":"2021","journal-title":"Phys. Med."},{"key":"bpexadd26bbib5","doi-asserted-by":"publisher","first-page":"3003","DOI":"10.1002\/mp.14866","article-title":"Improving generalization in MR-to-CT synthesis in radiotherapy by using an augmented cycle generative adversarial network with unpaired data","volume":"48","author":"Brou Boni","year":"2021","journal-title":"Med. Phys."},{"key":"bpexadd26bbib6","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab7633","article-title":"MR to CT synthesis with multicenter data in the pelvic area using a conditional generative adversarial network","volume":"65","author":"Brou Boni","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"bpexadd26bbib7","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.ejmp.2021.05.010","article-title":"Artificial intelligence in magnetic resonance guided radiotherapy: medical and physical considerations on state of art and future perspectives","volume":"85","author":"Cusumano","year":"2021","journal-title":"Phys. Med."},{"key":"bpexadd26bbib8","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/j.radonc.2020.10.018","article-title":"A deep learning approach to generate synthetic CT in low field MR-guided adaptive radiotherapy for abdominal and pelvic cases","volume":"153","author":"Cusumano","year":"2020","journal-title":"Radiother. Oncol."},{"key":"bpexadd26bbib9","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/s13014-016-0747-y","article-title":"A review of substitute CT generation for MRI-only radiation therapy","volume":"12","author":"Edmund","year":"2017","journal-title":"Radiat. Oncol."},{"key":"bpexadd26bbib10","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14155","article-title":"Deep learning in MRI-guided radiation therapy: a systematic review","volume":"25","author":"Eidex","year":"2023","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexadd26bbib11","doi-asserted-by":"publisher","first-page":"3627","DOI":"10.1002\/mp.13047","article-title":"Generating synthetic CTs from magnetic resonance images using generative adversarial networks","volume":"45","author":"Emami","year":"2018","journal-title":"Med. Phys."},{"key":"bpexadd26bbib12","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab857b","article-title":"Investigating conditional GAN performance with different generator architectures, an ensemble model, and different MR scanners for MR-sCT conversion","volume":"65","author":"Fetty","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"bpexadd26bbib13","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ab6e1f","article-title":"Generation of abdominal synthetic CTs from 0.35T MR images using generative adversarial networks for MR-only liver radiotherapy","volume":"6","author":"Fu","year":"2020","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexadd26bbib14","doi-asserted-by":"publisher","DOI":"10.1016\/j.phro.2024.100652","article-title":"Results of 2023 survey on the use of synthetic computed tomography for magnetic resonance Imaging-only radiotherapy: current status and future steps","volume":"32","author":"Fusella","year":"2024","journal-title":"Phys. Imaging Radiat. Oncol."},{"key":"bpexadd26bbib15","doi-asserted-by":"publisher","first-page":"2592","DOI":"10.1002\/mrm.29450","article-title":"The future of MRI in radiation therapy: challenges and opportunities for the MR community","volume":"88","author":"Goodburn","year":"2022","journal-title":"Magn. Reson. Med."},{"key":"bpexadd26bbib16","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.969463","article-title":"Synthetic CT generation for MRI-guided adaptive radiotherapy in prostate cancer","volume":"12","author":"Hsu","year":"2022","journal-title":"Front Oncol."},{"key":"bpexadd26bbib17","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.ijrobp.2017.08.043","article-title":"Systematic review of synthetic computed tomography generation methodologies for use in magnetic resonance imaging-only radiation therapy","volume":"100","author":"Johnstone","year":"2018","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexadd26bbib18","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.radonc.2019.03.026","article-title":"MRI-only brain radiotherapy: assessing the dosimetric accuracy of synthetic CT images generated using a deep learning approach","volume":"136","author":"Kazemifar","year":"2019","journal-title":"Radiother. Oncol."},{"key":"bpexadd26bbib19","doi-asserted-by":"publisher","DOI":"10.1148\/ryai.2020190027","article-title":"Attention-aware discrimination for MR-to-CT image translation using cycle-consistent generative adversarial networks","volume":"2","author":"Kearney","year":"2020","journal-title":"Radiol. Artif. Intell."},{"key":"bpexadd26bbib20","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1002\/mp.13927","article-title":"Patch-based generative adversarial neural network models for head and neck MR-only planning","volume":"47","author":"Klages","year":"2020","journal-title":"Med. Phys."},{"key":"bpexadd26bbib21","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1093\/jrr\/rrz063","article-title":"Feasibility of synthetic computed tomography generated with an adversarial network for multi-sequence magnetic resonance-based brain radiotherapy","volume":"61","author":"Koike","year":"2020","journal-title":"J. Radiat. Res."},{"key":"bpexadd26bbib22","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/j.phro.2022.11.011","article-title":"Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen","volume":"24","author":"Lapaeva","year":"2022","journal-title":"Phys. Imaging Radiat. Oncol."},{"key":"bpexadd26bbib23","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1016\/j.ijrobp.2019.08.049","article-title":"Comparison of deep learning-based and patch-based methods for pseudo-CT generation in MRI-based prostate dose planning","volume":"105","author":"Largent","year":"2019","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexadd26bbib24","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1016\/j.canrad.2020.01.008","article-title":"Head-and-Neck MRI-only radiotherapy treatment planning: From acquisition in treatment position to pseudo-CT generation","volume":"24","author":"Largent","year":"2020","journal-title":"Cancer Radiother"},{"key":"bpexadd26bbib25","doi-asserted-by":"publisher","first-page":"3565","DOI":"10.1002\/mp.13617","article-title":"MRI-only based synthetic CT generation using dense cycle consistent generative adversarial networks","volume":"46","author":"Lei","year":"2019","journal-title":"Med. Phys."},{"key":"bpexadd26bbib26","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.radonc.2022.08.028","article-title":"A deep learning approach to generate synthetic CT in low field MR-guided radiotherapy for lung cases","volume":"176","author":"Lenkowicz","year":"2022","journal-title":"Radiother. Oncol."},{"key":"bpexadd26bbib27","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20190067","article-title":"MRI-based treatment planning for liver stereotactic body radiotherapy: validation of a deep learning-based synthetic CT generation method","volume":"92","author":"Liu","year":"2019","journal-title":"Br. J. Radiol."},{"key":"bpexadd26bbib28","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1118\/1.598248","article-title":"A technique for the quantitative evaluation of dose distributions","volume":"25","author":"Low","year":"1998","journal-title":"Med. Phys."},{"key":"bpexadd26bbib29","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.radonc.2020.09.029","article-title":"Deep learning-based synthetic CT generation for paediatric brain MR-only photon and proton radiotherapy","volume":"153","author":"Maspero","year":"2020","journal-title":"Radiother. Oncol."},{"key":"bpexadd26bbib30","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aada6d","article-title":"Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy","volume":"63","author":"Maspero","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"bpexadd26bbib31","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aaaca4","article-title":"MRI-only treatment planning: benefits and challenges","volume":"63","author":"Owrangi","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"bpexadd26bbib32","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/s13534-022-00227-x","article-title":"Clinical application of deep learning-based synthetic CT from real MRI to improve dose planning accuracy in Gamma Knife radiosurgery: a proof of concept study","volume":"12","author":"Park","year":"2022","journal-title":"Biomed. Eng. Lett."},{"key":"bpexadd26bbib33","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.radonc.2020.06.049","article-title":"Magnetic resonance-based synthetic computed tomography images generated using generative adversarial networks for nasopharyngeal carcinoma radiotherapy treatment planning","volume":"150","author":"Peng","year":"2020","journal-title":"Radiother. Oncol."},{"key":"bpexadd26bbib34","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2023.1245054","article-title":"A multi-centric evaluation of self-learning GAN based pseudo-CT generation software for low field pelvic magnetic resonance imaging","volume":"13","author":"Prunaretty","year":"2023","journal-title":"Front Oncol."},{"key":"bpexadd26bbib35","doi-asserted-by":"publisher","first-page":"1880","DOI":"10.1002\/mp.14075","article-title":"Multi-sequence MR image-based synthetic CT generation using a generative adversarial network for head and neck MRI-only radiotherapy","volume":"47","author":"Qi","year":"2020","journal-title":"Med. Phys."},{"key":"bpexadd26bbib36","doi-asserted-by":"publisher","first-page":"109493H","DOI":"10.1117\/12.2513089","article-title":"Evaluating the impact of intensity normalization on MR image synthesis","volume":"10949","author":"Reinhold","year":"2019","journal-title":"Proc. SPIE Int. Soc. Opt. Eng."},{"key":"bpexadd26bbib37","doi-asserted-by":"publisher","first-page":"6537","DOI":"10.1002\/mp.15150","article-title":"Deep learning based synthetic-CT generation in radiotherapy and PET: a review","volume":"48","author":"Spadea","year":"2021","journal-title":"Med. Phys."},{"key":"bpexadd26bbib38","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac4123","article-title":"Synthesis of pseudo-CT images from pelvic MRI images based on an MD-CycleGAN model for radiotherapy","volume":"67","author":"Sun","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"bpexadd26bbib39","doi-asserted-by":"publisher","first-page":"1750","DOI":"10.1002\/mp.14062","article-title":"Pseudo-CT generation from multi-parametric MRI using a novel multi-channel multi-path conditional generative adversarial network for nasopharyngeal carcinoma patients","volume":"47","author":"Tie","year":"2020","journal-title":"Med. Phys."},{"key":"bpexadd26bbib40","doi-asserted-by":"publisher","first-page":"1310","DOI":"10.1109\/TMI.2010.2046908","article-title":"N4ITK: improved N3 bias correction","volume":"29","author":"Tustison","year":"2010","journal-title":"IEEE Trans. Med. Imaging"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/add26b","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/add26b\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/add26b","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/add26b\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/add26b\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/add26b\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/add26b\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/add26b\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T20:39:59Z","timestamp":1747687199000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/add26b"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,19]]},"references-count":40,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,5,19]]},"published-print":{"date-parts":[[2025,5,30]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/add26b","relation":{},"ISSN":["2057-1976"],"issn-type":[{"type":"electronic","value":"2057-1976"}],"subject":[],"published":{"date-parts":[[2025,5,19]]},"assertion":[{"value":"Feasibility study of a general model for synthetic CT generation in MRI-guided extracranial radiotherapy","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2024-10-30","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-04-30","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-05-19","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}