{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T05:23:07Z","timestamp":1780550587828,"version":"3.54.1"},"reference-count":18,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T00:00:00Z","timestamp":1749600000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T00:00:00Z","timestamp":1749600000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2025,7,31]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Purpose<\/jats:italic>. To investigate the effects of respiratory motion during fast (\u223c6 s) and slow (\u223c60 s) cone beam computed tomography (CBCT) acquisition modes, with a focus on implications for adaptive radiotherapy (ART). <jats:italic>Methods<\/jats:italic>. CBCT images are compared with 4D fan beam CT acquisitions, considering average (\u2018AVE\u2019) and maximum (\u2018MIP\u2019) intensity projections. Data are acquired using a respiratory motion phantom representing a human thorax with a lung tumour. A range of sup-inf motion amplitudes (3 to 11 mm) and periods (3 to 5 s) are considered. HU perturbations, target contouring implications, and dosimetric effects are considered. <jats:italic>Results<\/jats:italic>. Fast mode CBCT motion artefacts are more severe for larger amplitudes and longer periods. Motion artefacts are minimal in slow mode. The standard deviation of HU differences (CBCT minus AVE) in regions-of-interest encompassing the tumour are within 44 HU for slow mode, increasing up to 75 HU for fast mode. Target volumes contoured using HU thresholding on slow mode CBCTs are smaller than those on the AVE\/MIP by up to 7%\/29%. HU thresholding was not applied to fast mode CBCTs because motion artefacts were judged to be too severe. Gamma pass rates for dose distributions calculated on fast or slow mode CBCTs compared to the AVE are <jats:inline-formula>\n                     <jats:tex-math>\n\n<\/jats:tex-math>\n                     <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mo>\u2265<\/mml:mo>\n                     <\/mml:math>\n\n                  <\/jats:inline-formula> 99% (criteria: 1%, 1 mm, 10% dose threshold). Dose differences (fast mode CBCT minus AVE) are larger for larger amplitudes and longer periods, and tend toward negative values. Dose differences (slow mode CBCT minus AVE) are generally smaller and more consistent across all amplitudes and periods considered. <jats:italic>Conclusions<\/jats:italic>. Dosimetric perturbations resulting from motion artefacts are not severe for the amplitudes and periods considered. However, motion artefacts (especially in fast mode) have implications for image registration, target contouring, and treatment plan optimization for ART.<\/jats:p>","DOI":"10.1088\/2057-1976\/adde65","type":"journal-article","created":{"date-parts":[[2025,5,29]],"date-time":"2025-05-29T22:48:26Z","timestamp":1748558906000},"page":"045012","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["Cone beam computed tomography in 6- and 60-second acquisitions: implications for adaptive radiotherapy when respiratory motion is present"],"prefix":"10.1088","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9485-4768","authenticated-orcid":true,"given":"P A K","family":"Oliver","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L","family":"Montgomery","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D A","family":"Granville","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,6,11]]},"reference":[{"key":"bpexadde65bib1","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.prro.2023.10.014","article-title":"Novel technology allowing cone beam computed tomography in 6 s: a patient study of comparative image quality","volume":"14","author":"Robar","year":"2024","journal-title":"Practical. Radiat. Oncol."},{"key":"bpexadde65bib2","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14299","article-title":"ACR benchmark testing of a novel high-speed ring-gantry linac kV-CBCT system","volume":"25","author":"Haertter","year":"2024","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexadde65bib3","doi-asserted-by":"publisher","first-page":"7492","DOI":"10.1002\/mp.17325","article-title":"Technical note: phantom-based evaluation of CBCT dose","volume":"51","author":"Wessels","year":"2024","journal-title":"Med. Phys."},{"key":"bpexadde65bib4","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14516","article-title":"Evaluation of a metal artifact reduction algorithm for image reconstruction on a novel CBCT platform","volume":"25","author":"Yashayaeva","year":"2024","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexadde65bib5","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ad3cb0","article-title":"Image quality evaluation of a new high- performance ring-gantry cone-beam computed tomography imager","volume":"69","author":"Lustermans","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"bpexadde65bib6","doi-asserted-by":"publisher","first-page":"4689","DOI":"10.1118\/1.3613153","article-title":"Potential underestimation of the internal target volume (ITV) from free-breathing CBCT","volume":"38","author":"Vergalasova","year":"2011","journal-title":"Med. Phys."},{"key":"bpexadde65bib7","doi-asserted-by":"publisher","DOI":"10.1118\/1.4773310","article-title":"The effect of irregular breathing patterns on internal target volumes in four-dimensional CT and cone-beam CT images in the context of stereotactic lung radiotherapy","volume":"40","author":"Clements","year":"2013","journal-title":"Med. Phys."},{"key":"bpexadde65bib8","doi-asserted-by":"publisher","first-page":"4709","DOI":"10.1002\/mp.16994","article-title":"Impact of cone-beam computed tomography artifacts on dose calculation accuracy for lung cancer","volume":"51","author":"Schr\u00f6der","year":"2024","journal-title":"Med. Phys."},{"key":"bpexadde65bib9","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2024.110596","article-title":"Dose calculation accuracy of a new high-performance ring-gantry CBCT imaging system for prostate and lung cancer patients","volume":"202","author":"Sijtsema","year":"2025","journal-title":"Radiother. Oncol."},{"key":"bpexadde65bib10","author":"Chourpiliadis","year":"2022"},{"key":"bpexadde65bib11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.18637\/jss.v086.i08","article-title":"Image segmentation, registration and characterization in R with SimpleITK","volume":"86","author":"Beare","year":"2018","journal-title":"J. Stat. Software"},{"key":"bpexadde65bib12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/16878507.2019.1693176","article-title":"The effects of CT x-ray tube voltage and current variations on the relative electron density (RED) and CT number conversion curves","volume":"13","author":"Afifi","year":"2020","journal-title":"J. Radiat. Res. Appl. Sci."},{"key":"bpexadde65bib13","doi-asserted-by":"publisher","first-page":"2762","DOI":"10.1118\/1.1609271","article-title":"Quality assurance for computed-tomography simulators and the computed- tomography-simulation process: report of the AAPM radiation therapy committee task group no. 66","volume":"30","author":"Mutic","year":"2003","journal-title":"Med. Phys."},{"key":"bpexadde65bib14","doi-asserted-by":"publisher","first-page":"e761","DOI":"10.1002\/mp.13095","article-title":"On the data acquisition, image reconstruction, cone beam artifacts, and their suppression in axial MDCT and CBCT\u2014a review","volume":"45","author":"Tang","year":"2018","journal-title":"Med. Phys."},{"key":"bpexadde65bib15","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1016\/S0360-3016(02)02803-1","article-title":"Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy","volume":"53","author":"Seppenwoolde","year":"2002","journal-title":"Int. J. Radiation Oncology Biol. Phys."},{"key":"bpexadde65bib16","doi-asserted-by":"publisher","first-page":"4999","DOI":"10.1118\/1.4737095","article-title":"External respiratory motion: shape analysis and custom realistic respiratory trace generation","volume":"39","author":"Quirk","year":"2012","journal-title":"Med. Phys."},{"key":"bpexadde65bib17","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.radonc.2019.02.019","article-title":"Both four-dimensional computed tomography and four-dimensional cone beam computed tomography under-predict lung target motion during radiotherapy","volume":"135","author":"Steiner","year":"2019","journal-title":"Radiother. Oncol."},{"key":"bpexadde65bib18","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1016\/j.ijrobp.2024.02.054","article-title":"Adapt or perish: adaptive RT for NSCLC","volume":"119","author":"Harris","year":"2024","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adde65","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adde65\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adde65","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adde65\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adde65\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adde65\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adde65\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adde65\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T17:18:22Z","timestamp":1749662302000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adde65"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,11]]},"references-count":18,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,6,11]]},"published-print":{"date-parts":[[2025,7,31]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/adde65","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,11]]},"assertion":[{"value":"Cone beam computed tomography in 6- and 60-second acquisitions: implications for adaptive radiotherapy when respiratory motion is present","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-03-17","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-05-29","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-06-11","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}