{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T17:40:17Z","timestamp":1792086017178,"version":"4.4.0"},"reference-count":40,"publisher":"IOP Publishing","issue":"6","license":[{"start":{"date-parts":[[2025,11,25]],"date-time":"2025-11-25T00:00:00Z","timestamp":1764028800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2025,11,25]],"date-time":"2025-11-25T00:00:00Z","timestamp":1764028800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100018556","name":"Suzhou Science and Technology Project","doi-asserted-by":"crossref","award":["SKYD2022096"],"award-info":[{"award-number":["SKYD2022096"]}],"id":[{"id":"10.13039\/501100018556","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Huzhou Science and Technology Project","award":["2022GZ46"],"award-info":[{"award-number":["2022GZ46"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2025,11,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    As physiological artifacts commonly overlap with EEG signals in both time and frequency domains, developing an effective end-to-end EEG artifact removal method is essential for a brain-computer interface (BCI) system. An end-to-end artifact removal method based on nested generative adversarial network (GAN) is proposed, to recover the EEG signals from artifact-contaminated ones. The nested GAN consists of two components: an inner GAN operating in time-frequency domain and an outer GAN functioning in time domain. A light-weighted complex-valued restormer, designed in time-frequency domain, is employed as the generator to reconstruct the denoised EEG signal. Two metric discriminators in the inner GAN and two multi-resolution discriminators in the outer GAN are used, and gradient balance is used to address the partial learning issue during training. The performance of the nested GAN has been evaluated in the realistic EEG dataset and semi-synthetic dataset. Compared to the benchmark methods, the proposed one achieved best average performance evaluation metrics, including mean square error (MSE) = 0.098, Pearson correlation coefficient (PCC) = 0.892, relative root MSE (RRMSE) = 0.065, the percentage reduction of time domain artifacts (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msub>\n                          <mml:mrow>\n                            <mml:mi>\u03b7<\/mml:mi>\n                          <\/mml:mrow>\n                          <mml:mrow>\n                            <mml:mtext>temporal<\/mml:mtext>\n                          <\/mml:mrow>\n                        <\/mml:msub>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ) = 71.6%, and the percentage reduction of frequency domain artifacts (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:msub>\n                          <mml:mrow>\n                            <mml:mi>\u03b7<\/mml:mi>\n                          <\/mml:mrow>\n                          <mml:mrow>\n                            <mml:mtext>spectral<\/mml:mtext>\n                          <\/mml:mrow>\n                        <\/mml:msub>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ) = 76.9%. The performance of artifact removal also showed robustness across a wide range of signal-to-noise ratio (SNR) levels.The superior performance of the proposed end-to-end artifact removal method is expected to contribute to the advancement of BCI system development.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ae1a8c","type":"journal-article","created":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T22:47:53Z","timestamp":1762210073000},"page":"065054","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["End-to-end EEG artifact removal method via nested generative adversarial network"],"prefix":"10.1088","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-4907-067X","authenticated-orcid":true,"given":"Tianqi","family":"Yang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nan","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shengsheng","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7071-9764","authenticated-orcid":true,"given":"Dongyang","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2025,11,25]]},"reference":[{"key":"bpexae1a8cbib1","doi-asserted-by":"publisher","DOI":"10.1016\/j.yebeh.2019.106486","type":"journal-article","article-title":"Predictive value of acute EEG measurements for seizures and epilepsy after stroke using a dry cap electrode EEG system \u2014 Study design and proof of concept","volume":"104","author":"Doerrfuss","year":"2020","journal-title":"Epilepsy& Behavior"},{"key":"bpexae1a8cbib2","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1016\/0013-4694(91)90039-7","type":"journal-article","article-title":"The instruction to refrain from blinking affects auditory P3 and N1 amplitudes","volume":"78","author":"Verleger","year":"1991","journal-title":"Electroencephalography & Clinical Neurophysiology"},{"key":"bpexae1a8cbib3","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1016\/S1388-2457(00)00541-1","type":"journal-article","article-title":"The effects of ocular artifacts on (lateralized) broadband power in the EEG","volume":"112","author":"Hagemann","year":"2001","journal-title":"Clinical Neurophysiology"},{"key":"bpexae1a8cbib4","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/j.bspc.2011.02.001","type":"journal-article","article-title":"REG-ICA: A hybrid methodology combining blind source Separation and regression techniques for the rejection of ocular artifacts","volume":"6","author":"Klados","year":"2011","journal-title":"Biomedical Signal Processing & Control"},{"key":"bpexae1a8cbib5","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1016\/S0987-7053(00)00055-1","type":"journal-article","article-title":"Removal of ocular artifact from the EEG: a review","volume":"30","author":"Croft","year":"2000","journal-title":"Neurophysiologie Clinique-clinical Neurophysiology"},{"key":"bpexae1a8cbib6","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1088\/1741-2560\/12\/3\/031001","type":"journal-article","article-title":"EEG artifact removal\u2014state-of-the-art and guidelines","volume":"12","author":"Urig\u00fcen","year":"2015","journal-title":"J. Neural Eng."},{"key":"bpexae1a8cbib7","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1109\/TNSRE.2013.2254724","type":"journal-article","article-title":"On the automated removal of artifacts related to head movement from the EEG","volume":"21","author":"Daly","year":"2013","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"bpexae1a8cbib8","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/0165-1684(94)90029-9","type":"journal-article","article-title":"Independent component analysis, a new concept?","volume":"36","author":"Comon","year":"1994","journal-title":"Signal Process."},{"key":"bpexae1a8cbib9","doi-asserted-by":"publisher","first-page":"2583","DOI":"10.1109\/TBME.2006.879459","type":"journal-article","article-title":"Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram","volume":"53","author":"Clercq","year":"2006","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexae1a8cbib10","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1111\/j.0013-9580.2004.12104.x","type":"journal-article","article-title":"Independent component analysis removing artifacts in ictal recordings","volume":"45","author":"Urrestarazu","year":"2004","journal-title":"Epilepsia"},{"key":"bpexae1a8cbib11","doi-asserted-by":"publisher","first-page":"2188","DOI":"10.1109\/TBME.2010.2051440","type":"journal-article","article-title":"Source separation from single-channel recordings by combining empirical-mode decomposition and independent component analysis","volume":"57","author":"Mijovi\u0107","year":"2010","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexae1a8cbib12","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1098\/rspa.1998.0193","type":"journal-article","article-title":"The empirical mode decomposition and the hilbert spectrum for nonlinear and non-stationary time series analysis","volume":"454","author":"Huang","year":"1998","journal-title":"Proceedings Mathematical Physical & Engineering sciences"},{"key":"bpexae1a8cbib13","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1109\/5.488704","type":"journal-article","article-title":"A review of wavelets in biomedical applications","volume":"84","author":"Unser","year":"1996","journal-title":"Proc. IEEE"},{"key":"bpexae1a8cbib14","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.1109\/TBME.2009.2038667","type":"journal-article","article-title":"Motion artifact removal for functional near infrared spectroscopy: a comparison of methods","volume":"57","author":"Robertson","year":"2010","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexae1a8cbib15","doi-asserted-by":"publisher","first-page":"987","DOI":"10.3390\/s19050987","type":"journal-article","article-title":"Removal of artifacts from EEG signals: a review","volume":"19","author":"Jiang","year":"2019","journal-title":"Sensors (Basel)"},{"key":"bpexae1a8cbib16","doi-asserted-by":"publisher","first-page":"1\u201315","DOI":"10.1186\/1687-6180-2012-127","type":"journal-article","article-title":"Removal of muscle artifact from EEG data: comparison between stochastic (ICA and CCA) and deterministic (EMD and wavelet-based) approaches","volume":"1","author":"Safieddine","year":"2012","journal-title":"EURASIP Journal on Advances in Signal Processing"},{"key":"bpexae1a8cbib17","doi-asserted-by":"publisher","first-page":"355","DOI":"10.3390\/brainsci9120355","type":"journal-article","article-title":"Improved EOG artifact removal using wavelet enhanced independent component analysis","volume":"9","author":"Issa","year":"2019","journal-title":"Brain sciences"},{"key":"bpexae1a8cbib18","first-page":"1250","type":"conference-proceedings","article-title":"Introducing a combination of ICA-EMD to suppress muscle and ocular artifacts in EEG signals","volume":"40","author":"Santill\u00e1n-Guzm\u00e1n","year":"2018"},{"key":"bpexae1a8cbib19","doi-asserted-by":"publisher","first-page":"3607","DOI":"10.1109\/JBHI.2021.3131186","type":"journal-article","article-title":"Automated CCA-MWF algorithm for unsupervised identification and removal of EOG artifacts from EEG","volume":"26","author":"Miao","year":"2022","journal-title":"IEEE Journal of Biomedical and Health Informatics"},{"key":"bpexae1a8cbib20","first-page":"1","type":"conference-proceedings","article-title":"Wavelet transform and circulant singular spectrum analysis for improved EOG artifact elimination from electroencephalogram signals","author":"Chourasiya","year":"2025"},{"key":"bpexae1a8cbib21","first-page":"1","type":"journal-article","article-title":"Hybrid MVMD-ICA framework for EOG artifacts removal from few-channel EEG signals","volume":"6","author":"Fang","year":"2025","journal-title":"International Conference on Bio-engineering for Smart Technologies (BioSMART)"},{"key":"bpexae1a8cbib22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TETCI.2025.3577504","type":"journal-article","article-title":"Adaptive thresholding in EEG artifact removal through multimodal fusion: a multimodal artifact subspace reconstruction approach","volume":"1","author":"You","year":"2025","journal-title":"IEEE Transactions on Emerging Topics in Computational Intelligence Early Access"},{"key":"bpexae1a8cbib23","doi-asserted-by":"publisher","first-page":"28677","DOI":"10.1109\/JSEN.2025.3578066","type":"journal-article","article-title":"Adaptive EOG artifact removal algorithm using a spectrum magnitude template matching for single-channel EEG","volume":"25","author":"Liu","year":"2025","journal-title":"IEEE Sens. J."},{"key":"bpexae1a8cbib24","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.neucom.2014.08.092","type":"journal-article","article-title":"Feature learning from incomplete EEG with denoising autoencoder","volume":"165","author":"Li","year":"2015","journal-title":"Neurocomputing"},{"key":"bpexae1a8cbib25","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2022.119586","type":"journal-article","article-title":"IC-U-Net: a U-Net-based denoising autoencoder using mixtures of independent components for automatic EEG artifact removal","volume":"263","author":"Chuang","year":"2022","journal-title":"Neuroimage"},{"key":"bpexae1a8cbib26","first-page":"234","type":"journal-article","article-title":"U-Net: Convolutional Networks for Biomedical Image Segmentation","volume":"9351","author":"Ronneberger","year":"2015","journal-title":"Medical Image Computing and Computer-Assisted Intervention"},{"key":"bpexae1a8cbib27","first-page":"2605","type":"conference-proceedings","article-title":"Deep convolutional autoencoder for EEG noise filtering","author":"Leite","year":"2018"},{"key":"bpexae1a8cbib28","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.compbiomed.2019.04.034","type":"journal-article","article-title":"Assessing cognitive mental workload via EEG signals and an ensemble deep learning classifier based on denoising autoencoders","volume":"109","author":"Yang","year":"2019","journal-title":"Comput. Biol. Med."},{"key":"bpexae1a8cbib29","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.neucom.2020.04.029","type":"journal-article","article-title":"A novel end-to-end 1D-ResCNN model to remove artifact from EEG signals","volume":"404","author":"Sun","year":"2020","journal-title":"Neurocomputing"},{"key":"bpexae1a8cbib30","first-page":"1265","type":"conference-proceedings","article-title":"A novel convolutional neural network model to remove muscle artifacts from EEG","author":"Zhang","year":"2021"},{"key":"bpexae1a8cbib31","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/ac2bf8","type":"journal-article","article-title":"EEGdenoiseNet: a benchmark dataset for deep learning solutions of eegdenoising","volume":"18","author":"Zhang","year":"2021","journal-title":"J. Neural Eng."},{"key":"bpexae1a8cbib32","doi-asserted-by":"publisher","first-page":"49528","DOI":"10.1109\/ACCESS.2022.3173261","type":"journal-article","article-title":"A novel multimodule neural network for EEG denoising","volume":"10","author":"Zhang","year":"2022","journal-title":"IEEE Access"},{"key":"bpexae1a8cbib33","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2022.106248","type":"journal-article","article-title":"EEGDnet: fusing non-local and local self-similarity for EEG signal denoising with transformer","volume":"151","author":"Pu","year":"2022","journal-title":"Comput. Biol. Med."},{"key":"bpexae1a8cbib34","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/JBHI.2025.3573042","type":"journal-article","article-title":"DenoiseMamba: an innovative approach for EEG artifact removal leveraging mamba and CNN","volume":"29","author":"Chen","year":"2025","journal-title":"IEEE Journal of Biomedical and Health Informatics Early Access"},{"key":"bpexae1a8cbib35","article-title":"EEG-GAN: generative adversarial networks for electroencephalograhic (EEG) brain signals","author":"Hartmann","year":"2018","type":"other"},{"key":"bpexae1a8cbib36","doi-asserted-by":"publisher","first-page":"4913","DOI":"10.1109\/JBHI.2021.3131104","type":"journal-article","article-title":"EEGANet: removal of ocular artifacts from the EEG signal using generative adversarial networks","volume":"26","author":"Sawangjai","year":"2021","journal-title":"IEEE Journal of Biomedical and Health Informatics"},{"key":"bpexae1a8cbib37","doi-asserted-by":"publisher","DOI":"10.1109\/JBHI.2023.3277596","type":"journal-article","article-title":"A GAN guided parallel CNN and transformer network for EEG denoising","volume":"29","author":"Yin","year":"2023","journal-title":"IEEE Journal of Biomedical and Health Informatics"},{"key":"bpexae1a8cbib38","first-page":"14910","type":"journal-article","article-title":"Melgan: generative adversarial networks for conditional waveform synthesis","volume":"32","author":"Kumar","year":"2019","journal-title":"Advances in Neural Information Processing Systems"},{"key":"bpexae1a8cbib39","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3390\/bios12010022","type":"journal-article","article-title":"A multibranch of convolutional neural network models for electroencephalogram-based motor imagery classification","volume":"12","author":"Altuwaijri","year":"2022","journal-title":"Biosensors"},{"key":"bpexae1a8cbib40","doi-asserted-by":"publisher","first-page":"1004","DOI":"10.1016\/j.dib.2016.06.032","type":"journal-article","article-title":"A semi-simulated EEG\/EOG dataset for the comparison of EOG artifact rejection techniques","volume":"8","author":"Klados","year":"2016","journal-title":"Data in Brief"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae1a8c","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae1a8c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae1a8c","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae1a8c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae1a8c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae1a8c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae1a8c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae1a8c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,25]],"date-time":"2025-11-25T12:53:52Z","timestamp":1764075232000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae1a8c"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,25]]},"references-count":40,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,11,25]]},"published-print":{"date-parts":[[2025,11,28]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae1a8c","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,25]]},"assertion":[{"value":"End-to-end EEG artifact removal method via nested generative adversarial network","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2025-05-16","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-11-03","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-11-25","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}