{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T20:58:08Z","timestamp":1768337888492,"version":"3.49.0"},"reference-count":10,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T00:00:00Z","timestamp":1768262400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T00:00:00Z","timestamp":1768262400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study aims to investigate the impact of position-dependent CT number variations and image bit-depth, which determines the range of encodable CT numbers, on relative electron density (RED) conversion, a process essential for accurate radiation dose calculation, for patients with high-Z materials or metal implants. A commercially available phantom containing tissue-equivalent rods and metal implant inserts was scanned using a clinical CT simulator at nine positional offsets (isocenter, \u00b16.5 cm, and \u00b110.5 cm in lateral and anterior-posterior directions). CT images were acquired with both 12-bit and 16-bit scanning modes under identical scanning conditions. HU values for each insert were measured across positions and converted to RED using the clinical HU-to-RED calibration curve. HU deviations increased with positional displacement, particularly in high-density materials such as titanium and stainless steel. In 12-bit datasets, HU saturation at 3071 HU led to errors in the RED underestimation, while 16-bit imaging preserved accurate HU values even at off-center positions. Off-center positioning and bit-depth limitations significantly affect HU representation and RED conversion, especially with high-Z materials. Adoption of 16-bit acquisition or manual assignment of electron density values is recommended to prevent HU saturation and further ensure robust dose calculation. These findings highlight the importance of imaging bit depth and patient centering as part of routine radiotherapy quality assurance, particularly for cases involving metallic implants or off-isocenter targets.<\/jats:p>","DOI":"10.1088\/2057-1976\/ae318c","type":"journal-article","created":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T22:47:45Z","timestamp":1767048465000},"page":"015044","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["HU variation with various positions in field of view (FOV) and bit-depth in CT simulation"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-9915-9888","authenticated-orcid":true,"given":"Gyujin","family":"Seo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7864-0233","authenticated-orcid":true,"given":"Daehong","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyunji","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4094-0892","authenticated-orcid":true,"given":"Indra","family":"Das","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9173-7141","authenticated-orcid":true,"given":"Siyong","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7209-4104","authenticated-orcid":true,"given":"James J","family":"Sohn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2026,1,13]]},"reference":[{"key":"bpexae318cbib1","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1007\/s13246-015-0353-6","type":"journal-article","article-title":"An assessment of image distortion and CT number accuracy within a wide-bore CT extended field of view","volume":"38","author":"Beeksma","year":"2015","journal-title":"Australas. Phys. Eng. Sci. Med."},{"key":"bpexae318cbib2","doi-asserted-by":"publisher","first-page":"2762","DOI":"10.1118\/1.1609271","type":"journal-article","article-title":"Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: report of the AAPM radiation therapy committee task group No. 66","volume":"30","author":"Mutic","year":"2003","journal-title":"Med. Phys."},{"key":"bpexae318cbib3","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.ejmp.2011.06.002","type":"journal-article","article-title":"Impact of miscentering on patient dose and image noise in x-ray CT imaging: phantom and clinical studies","volume":"28","author":"Habibzadeh","year":"2012","journal-title":"Med. Phys."},{"key":"bpexae318cbib4","doi-asserted-by":"publisher","first-page":"579","DOI":"10.2214\/AJR.16.17215","type":"journal-article","article-title":"Variation in CT number and image noise uniformity according to patient positioning in MDCT","volume":"208","author":"Szczykutowicz","year":"2017","journal-title":"Am. J. Roentgenol."},{"key":"bpexae318cbib5","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/aad66a","type":"journal-article","article-title":"The effect of different CT scanners, scan parameters and scanning setup on Hounsfield units and calibrated bone density: a phantom study","volume":"4","author":"Free","year":"2018","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexae318cbib6","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1038\/s41598-020-57422-y","type":"journal-article","article-title":"Effects of image distortion and Hounsfield unit variations on radiation treatment plans: an extended field-of-view reconstruction in a large bore CT scanner","volume":"10","author":"Bae","year":"2020","journal-title":"Sci. Rep."},{"key":"bpexae318cbib7","first-page":"2373","type":"journal-article","article-title":"Effects of 16-bit CT imaging scanning conditions for metal implants on radiotherapy dose distribution","volume":"15","author":"Gao","year":"2018","journal-title":"Oncol Lett"},{"key":"bpexae318cbib8","year":"2023","type":"other"},{"key":"bpexae318cbib9","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1136\/jamia.1997.0040199","type":"journal-article","article-title":"Understanding and using DICOM, the data interchange standard for biomedical imaging","volume":"4","author":"Bidgood","year":"1997","journal-title":"J. Am. Med. Inform. Assoc."},{"key":"bpexae318cbib10","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1017\/S1460396919000013","type":"journal-article","article-title":"Determination of computed tomography number of high-density materials in 12-bit, 12-bit extended, and 16-bit depth for dosimetric calculation in treatment planning system","volume":"18","author":"Jayamani","year":"2019","journal-title":"J. Radiother. Pract."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae318c","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae318c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae318c","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae318c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae318c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae318c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae318c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae318c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T14:28:29Z","timestamp":1768314509000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae318c"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,13]]},"references-count":10,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,1,13]]},"published-print":{"date-parts":[[2026,2,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae318c","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,13]]},"assertion":[{"value":"HU variation with various positions in field of view (FOV) and bit-depth in CT simulation","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-06-30","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-12-29","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-01-13","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}