{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T02:59:44Z","timestamp":1769137184598,"version":"3.49.0"},"reference-count":18,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T00:00:00Z","timestamp":1769040000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T00:00:00Z","timestamp":1769040000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study aimed to assess a visual-tactile breath-hold (BH) workflow integrated with Elekta Unity\u2019s comprehensive motion management (CMM) system for gated MR-guided radiotherapy in situations where verbal coaching is impractical. A visual guidance program and a 3D-printed couch-mounted tactile pointer were implemented to instruct patients and stabilize voluntary BH. Two patients, one with pancreatic cancer and one with lung cancer, were treated using this workflow. Treatment beam gating was driven by CMM BH criteria, and audit log files from CMM-guided treatments were analyzed. Expected gating efficiencies were 40% for the pancreas case and 51.4% for the lung case, while measured efficiencies were 42.59 \u00b1 2.56% and 54.95 \u00b1 0.54%, respectively. The corresponding beam-on times were 14.75 \u00b1 0.96 and 16.25 \u00b1 0.50 min. The workflow reduced reliance on motion prediction for gating and mitigated frequent beam holds typically observed with free-breathing strategies, thereby decreasing dosimetric uncertainty. These findings indicate that a visual-tactile BH workflow on a 1.5 T MR-Linac is feasible and practical, supporting efficient gated delivery and reproducible breath-holds when verbal coaching is limited.<\/jats:p>","DOI":"10.1088\/2057-1976\/ae3570","type":"journal-article","created":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T22:47:41Z","timestamp":1767912461000},"page":"017002","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Feasibility of breath-hold gating with visual-tactile guidance on an MR-Linac"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6105-4772","authenticated-orcid":false,"given":"Kai","family":"Yuan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3477-6865","authenticated-orcid":true,"given":"Matthew Manhin","family":"Cheung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wai Kin","family":"Lai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-2660-1611","authenticated-orcid":true,"given":"Wing Ki","family":"Wong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashley Chi Kin","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-3625-5306","authenticated-orcid":false,"given":"Louis","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2026,1,22]]},"reference":[{"key":"bpexae3570bib1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20220461","type":"journal-article","article-title":"Evaluation of tumour motion and internal\/external correlation in lung SABR","volume":"96","author":"Ali","year":"2023","journal-title":"Br. J. Radiol."},{"key":"bpexae3570bib2","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1016\/j.ijrobp.2008.11.066","type":"journal-article","article-title":"Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography","volume":"75","author":"Bissonnette","year":"2009","journal-title":"International Journal of Radiation Oncology*Biology*Physics"},{"key":"bpexae3570bib3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2025.105189","type":"journal-article","article-title":"Characterizing the motion management system accuracy on a 1.5T MR-Linac","volume":"139","author":"Donahue","year":"2025","journal-title":"Physica Med."},{"key":"bpexae3570bib4","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2024.1441227","type":"journal-article","article-title":"Clinical experience with adaptive MRI-guided pancreatic SBRT and the use of abdominal compression to reduce treatment volume [Original Research]","author":"Ferris","year":"2024","journal-title":"Frontiers in Oncology, Volume 14 - 2024"},{"key":"bpexae3570bib5","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/519602","type":"journal-article","article-title":"Respiratory gating for radiotherapy: main technical aspects and clinical benefits","volume":"2013","author":"Giraud","year":"2013","journal-title":"International Scholarly Research Notices"},{"key":"bpexae3570bib6","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1088\/0031-9155\/51\/3\/011","type":"journal-article","article-title":"Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT","volume":"51","author":"Grigorov","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"bpexae3570bib7","doi-asserted-by":"publisher","first-page":"2773","DOI":"10.1002\/mp.17743","type":"journal-article","article-title":"Quantifying the dosimetric accuracy of expiration-gated stereotactic lung radiotherapy","volume":"52","author":"Hoffmans","year":"2025","journal-title":"Med. Phys."},{"key":"bpexae3570bib8","doi-asserted-by":"publisher","first-page":"3103","DOI":"10.1002\/mp.16342","type":"journal-article","article-title":"Real-time motion monitoring using orthogonal cine MRI during MR-guided adaptive radiation therapy for abdominal tumors on 1.5T MR-Linac","volume":"50","author":"Jassar","year":"2023","journal-title":"Med. Phys."},{"key":"bpexae3570bib9","doi-asserted-by":"publisher","first-page":"3874","DOI":"10.1118\/1.2349696","type":"journal-article","article-title":"The management of respiratory motion in radiation oncology report of AAPM Task Group 76","volume":"33","author":"Keall","year":"2006","journal-title":"Med. Phys."},{"key":"bpexae3570bib10","doi-asserted-by":"publisher","first-page":"4197","DOI":"10.1118\/1.3190392","type":"journal-article","article-title":"Task Group 142 report: quality assurance of medical accelerators","volume":"36","author":"Klein","year":"2009","journal-title":"Med. Phys."},{"key":"bpexae3570bib11","doi-asserted-by":"publisher","DOI":"10.1016\/j.ctro.2025.101044","type":"journal-article","article-title":"Dosimetric and treatment efficiency comparison of lung SBRT using three different motion management strategies","volume":"56","author":"Lansing","year":"2026","journal-title":"Clinical and Translational Radiation Oncology"},{"key":"bpexae3570bib12","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1053\/j.semradonc.2003.10.009","type":"journal-article","article-title":"Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment","volume":"14","author":"Mageras","year":"2004","journal-title":"Semin. Radiat. Oncol."},{"key":"bpexae3570bib13","doi-asserted-by":"publisher","first-page":"206","DOI":"10.4103\/jmp.JMP_18_17","type":"journal-article","article-title":"The impact of dose rate on the accuracy of step-and-shoot intensity-modulated radiation therapy quality assurance using varian 2300CD","volume":"42","author":"Njeh","year":"2017","journal-title":"Journal of Medical Physics"},{"key":"bpexae3570bib14","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14566","type":"journal-article","article-title":"Surrogate gating strategies for the Elekta Unity MR-Linac gating system","volume":"26","author":"Rusu","year":"2025","journal-title":"Journal of Applied Clinical Medical Physics"},{"key":"bpexae3570bib15","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.70005","type":"journal-article","article-title":"Commissioning of a motion management system for a 1.5T Elekta Unity MR-Linac: a single institution experience","volume":"26","author":"Smith","year":"2025","journal-title":"Journal of Applied Clinical Medical Physics"},{"key":"bpexae3570bib16","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1016\/S0360-3016(00)00518-6","type":"journal-article","article-title":"The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy","volume":"47","author":"van Herk","year":"2000","journal-title":"International Journal of Radiation Oncology, Biology, Physics"},{"key":"bpexae3570bib17","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/j.prro.2024.12.001","type":"journal-article","article-title":"Patient positional uncertainty and margin reduction in lung stereotactic ablative radiation therapy using pneumatic abdominal compression","volume":"15","author":"Walter","year":"2025","journal-title":"Practical Radiation Oncology"},{"key":"bpexae3570bib18","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.ctro.2019.04.001","type":"journal-article","article-title":"Adaptive radiotherapy: The Elekta Unity MR-linac concept","volume":"18","author":"Winkel","year":"2019","journal-title":"Clinical and Translational Radiation Oncology"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3570","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3570\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3570","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3570\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3570\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3570\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3570\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3570\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T11:20:59Z","timestamp":1769080859000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3570"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,22]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,1,22]]},"published-print":{"date-parts":[[2026,2,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae3570","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,22]]},"assertion":[{"value":"Feasibility of breath-hold gating with visual-tactile guidance on an MR-Linac","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-10-06","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-01-08","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-01-22","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}