{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T04:45:48Z","timestamp":1793508348367,"version":"4.5.0"},"reference-count":34,"publisher":"IOP Publishing","issue":"1","license":[{"start":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T00:00:00Z","timestamp":1770163200000},"content-version":"vor","delay-in-days":3,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T00:00:00Z","timestamp":1770163200000},"content-version":"tdm","delay-in-days":3,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100010982","name":"Philippine Council for Industry, Energy, and Emerging Technology Research and Development","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100010982","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100011096","name":"Philippine Council for Health Research and Development","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100011096","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100010892","name":"Department of Science and Technology, Republic of the Philippines","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100010892","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Purpose<\/jats:italic>\n                    . This study presents a novel method for fabricating a heterogeneous, tissue-equivalent mouse phantom model using additive manufacturing, together with dosimetric verification for applications in dosimetry for pre-clinical radiation research.\n                    <jats:italic>Methods<\/jats:italic>\n                    . Local Artificial Body for Radiation Analysis and Testing (LABRAT\n                    <jats:sup>\u00ae<\/jats:sup>\n                    ) mouse phantoms were developed based on the Digimouse model. After 3D rendering, a mold-and-assemble method of additive manufacturing was done using 1:1.3 polyurethane-resin material for lung tissue, 1:1 resin-hardener mixture for soft tissue, and resin with 30% hydroxyapatite for bone. Three types of phantoms were developed: LABRAT A (full mouse), LABRAT B (with ionization chamber provision), and LABRAT C (with axial slices along the head, upper lung, lower lung, abdomen, and spine for film dosimetry). Ionization chamber measurements were performed on LABRAT B under total-body irradiation (TBI) (0.5\u20132.0 Gy) using 130 kVp, 5.0 mA x-rays at a 23 cm source-to-phantom distance on top of a 5 cm PMMA slab. Film calibration and 2.5 Gy TBI were also conducted on LABRAT C to obtain axial dose maps. Computed tomography (CT) images were obtained, and CT numbers of the phantoms were extracted using Slicer 5.4.0.\n                    <jats:italic>Results<\/jats:italic>\n                    . The fabrication method produced identical LABRAT\n                    <jats:sup>\u00ae<\/jats:sup>\n                    phantoms suitable for pre-clinical dosimetry. In the open field plan, the measured dose for the LABRAT B phantom inside the acrylic mouse restrainer was observed to agree by up to \u00b12.6% of the prescribed dose. Film images revealed the corresponding dose maps in each axial slice, which show gradients corresponding to doses of 0 to 3 Gy. Mean CT numbers were \u2212621\u00a0\u00b1\u00a0119 HU (lung), 70\u00a0\u00b1\u00a040 HU (soft tissue), and 430\u00a0\u00b1\u00a0138 HU (bone).\n                    <jats:italic>Conclusion<\/jats:italic>\n                    . A heterogeneous mouse phantom was successfully developed and validated for dose verification in pre-clinical irradiation. LABRAT\n                    <jats:sup>\u00ae<\/jats:sup>\n                    materials demonstrated appropriate anatomical and radiological equivalence, with accurate dosimetric performance and good geometric agreement with the Digimouse model.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ae3b48","type":"journal-article","created":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T22:47:57Z","timestamp":1769035677000},"page":"015066","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Local artificial body for radiation analysis and testing (LABRAT\n                    <sup>\u00ae<\/sup>\n                    ): additive manufacturing and dosimetric measurements of a heterogeneous mouse model phantom for pre-clinical radiation research"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8441-2859","authenticated-orcid":false,"given":"Shalaine S","family":"Tatu-Qassim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John Paul C","family":"Cabahug","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"III","given":"Jose Bernardo L","family":"Padaca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laureen Ida M","family":"Ballesteros","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulysses B","family":"Ante","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Earl John T","family":"Geraldo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vladimir M","family":"Sarmiento","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos Emmanuel P","family":"Garcia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eugene P","family":"Guevara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Risty L","family":"Marzon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark Christian E","family":"Manuel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8826-9861","authenticated-orcid":true,"given":"Chitho P","family":"Feliciano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,2,4]]},"reference":[{"key":"bpexae3b48bib1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2021.106636","type":"journal-article","article-title":"Irradiation of subcutaneous mouse tumors with a clinical linear accelerator validated by alanine dosimetry","volume":"147","author":"Ankj\u00e6rgaard","year":"2021","journal-title":"Radiat. Meas."},{"key":"bpexae3b48bib2","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.ijrobp.2024.03.017","type":"journal-article","article-title":"Multi-institutional audit of FLASH and conventional dosimetry with a 3d printed anatomically realistic mouse Phantom","volume":"120","author":"Ashraf","year":"2024","journal-title":"International Journal of Radiation Oncology*Biology*Physics"},{"key":"bpexae3b48bib3","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1118\/1.4905489","type":"journal-article","article-title":"Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters","volume":"42","author":"Bache","year":"2015","journal-title":"Med. Phys."},{"key":"bpexae3b48bib4","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.ejmp.2020.11.001","type":"journal-article","article-title":"External beam radiation therapy with kilovoltage x-rays","volume":"79","author":"Breitkreutz","year":"2020","journal-title":"Physica Med."},{"key":"bpexae3b48bib5","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2025.113034","type":"journal-article","article-title":"Characterization and evaluation of tissue-equivalent materials for heterogeneous mouse model phantoms in radiobiology experiments","volume":"237","author":"Cabahug","year":"2025","journal-title":"Radiat. Phys. Chem."},{"key":"bpexae3b48bib6","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1007\/s12553-025-00972-w","type":"journal-article","article-title":"Characterization of beam output, dose homogeneity, and beam quality of a benchtop kilovoltage x-ray irradiator for radiobiology experiments","volume":"15","author":"Cabahug","year":"2025","journal-title":"Health and Technology"},{"key":"bpexae3b48bib7","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac9e88","type":"journal-article","article-title":"Comparison and calibration of dose delivered by137 Cs and x-ray irradiators in mice","volume":"67","author":"Caravaca","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"bpexae3b48bib8","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1088\/0031-9155\/52\/3\/003","type":"journal-article","article-title":"Digimouse: a 3D whole body mouse atlas from CT and cryosection data","volume":"52","author":"Dogdas","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"bpexae3b48bib9","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.ijrobp.2019.06.2545","type":"journal-article","article-title":"A dose of reality: how 20 years of incomplete physics and dosimetry reporting in radiobiology studies may have contributed to the reproducibility crisis","volume":"106","author":"Draeger","year":"2020","journal-title":"International Journal of Radiation Oncology*Biology*Physics"},{"key":"bpexae3b48bib10","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1002\/mp.13310","type":"journal-article","article-title":"Technical Note: Manufacturing of a realistic mouse phantom for dosimetry of radiobiology experiments","volume":"46","author":"Esplen","year":"2019","journal-title":"Medical Physics"},{"key":"bpexae3b48bib11","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1016\/j.clon.2021.08.011","type":"journal-article","article-title":"A brief overview of the preclinical and clinical radiobiology of microbeam radiotherapy","volume":"33","author":"Fukunaga","year":"2021","journal-title":"Clinical Oncology"},{"key":"bpexae3b48bib12","doi-asserted-by":"publisher","DOI":"10.3390\/app142310879","type":"journal-article","article-title":"Comparison of x-ray absorption in mandibular tissues and tissue-equivalent polymeric materials using PHITS Monte Carlo simulations","volume":"14","author":"Gokcekuyu","year":"2024","journal-title":"Applied Sciences"},{"key":"bpexae3b48bib13","doi-asserted-by":"publisher","first-page":"5757","DOI":"10.1002\/mp.16651","type":"journal-article","article-title":"Development of a morphologically realistic mouse phantom for pre-clinical photoacoustic imaging","volume":"50","author":"Grasso","year":"2023","journal-title":"Med. Phys."},{"key":"bpexae3b48bib14","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1093\/bjr\/tqaf066","type":"journal-article","article-title":"The importance of standardization and challenges of dosimetry in conventional preclinical radiation biology research","volume":"98","author":"Hill","year":"2025","journal-title":"Br. J. Radiol."},{"key":"bpexae3b48bib15","article-title":"Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water","author":"International Atomic Energy Agency","year":"2000","type":"book"},{"key":"bpexae3b48bib16","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1097\/HP.0000000000001601","type":"journal-article","article-title":"Radiation-induced cell death and its mechanisms","volume":"123","author":"Jiao","year":"2022","journal-title":"Health Phys."},{"key":"bpexae3b48bib17","doi-asserted-by":"publisher","first-page":"868","DOI":"10.1118\/1.1374247","type":"journal-article","article-title":"AAPM protocol for 40\u2013300 kV x-ray beam dosimetry in radiotherapy and radiobiology","volume":"28","author":"Ma","year":"2001","journal-title":"Med. Phys."},{"key":"bpexae3b48bib18","doi-asserted-by":"publisher","first-page":"1911","DOI":"10.1002\/mp.15487","type":"journal-article","article-title":"Dose calculations for preclinical radiobiology experiments conducted with single-field cabinet irradiators","volume":"49","author":"Mahuvava","year":"2022","journal-title":"Med. Phys."},{"key":"bpexae3b48bib19","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.ejmp.2013.03.001","type":"journal-article","article-title":"Underestimation of dose delivery in preclinical irradiation due to scattering conditions","volume":"30","author":"Noblet","year":"2014","journal-title":"Physica Med."},{"key":"bpexae3b48bib20","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1667\/rr14155.1","type":"journal-article","article-title":"Radiation biology irradiator dose verification survey","volume":"185","author":"Pedersen","year":"2016","journal-title":"Radiat. Res."},{"key":"bpexae3b48bib21","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab8078","type":"journal-article","article-title":"An open source heterogeneous 3D printed mouse phantom utilising a novel bone representative thermoplastic","volume":"65","author":"Price","year":"2020","journal-title":"Physics in Medicine & Biology"},{"key":"bpexae3b48bib22","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1120\/jacmp.v15i1.4439","type":"journal-article","article-title":"Energy response of EBT3 radiochromic films: Implications for dosimetry in kilovoltage range","volume":"15","author":"Villareal-Barajas","year":"2014","journal-title":"Journal of Applied Clinical Medical Physics"},{"key":"bpexae3b48bib23","article-title":"Development of an anti-bacterial calcium phosphate bioceramic orbital implant using local calcium carbonate and nano-zinc oxide [Poster presentation]","author":"Reyes","year":"2024","type":"conference-proceedings"},{"key":"bpexae3b48bib24","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.ejmp.2019.03.004","type":"journal-article","article-title":"Commissioning of the MultiRad 350 cell and small animal x-ray irradiation system","volume":"59","author":"Saikkonen","year":"2019","journal-title":"Physica Med."},{"key":"bpexae3b48bib25","first-page":"E84","type":"journal-article","article-title":"Evaluation of a small animal irradiation system for animal experiments using EBT3 model GAFCHROMIC TM film","volume":"63","author":"Shimizu","year":"2017","journal-title":"Kobe Journal of Medical Sciences"},{"key":"bpexae3b48bib26","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab215b","type":"journal-article","article-title":"Development of an anatomically correct mouse phantom for dosimetry measurement in small animal radiotherapy research","volume":"64","author":"Soultanidis","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"bpexae3b48bib27","doi-asserted-by":"publisher","DOI":"10.1016\/j.ctro.2024.100885","type":"journal-article","article-title":"Radiobiology and modelling in Brachytherapy: a review inspired by the ESTRO Brachytherapy pre-meeting course","volume":"50","author":"Stewart","year":"2025","journal-title":"Clinical and Translational Radiation Oncology"},{"key":"bpexae3b48bib28","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2020.109065","type":"journal-article","article-title":"Dosimetric characterization of an x-ray irradiator for use with cells","volume":"176","author":"Tatu","year":"2020","journal-title":"Radiat. Phys. Chem."},{"key":"bpexae3b48bib29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/09553002.2023.2250848","type":"journal-article","article-title":"Minimum reporting standards should be expected for preclinical radiobiology irradiators and dosimetry in the published literature","volume":"100","author":"Trompier","year":"2024","journal-title":"Int. J. Radiat. Biol."},{"key":"bpexae3b48bib30","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.radonc.2017.11.016","type":"journal-article","article-title":"ESTRO ACROP: technology for precision small animal radiotherapy research: optimal use and challenges","volume":"126","author":"Verhaegen","year":"2018","journal-title":"Radiother. Oncol."},{"key":"bpexae3b48bib31","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1667\/RR004CC.1","type":"journal-article","article-title":"Scattered dose calculations and measurements in a life-like mouse phantom","volume":"187","author":"Welch","year":"2017","journal-title":"Radiation Research"},{"key":"bpexae3b48bib32","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acc566","type":"journal-article","article-title":"Development and characterization of modular mouse phantoms for end-to-end testing and training in radiobiology experiments","volume":"68","author":"Wegner","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"bpexae3b48bib33","doi-asserted-by":"publisher","first-page":"4713","DOI":"10.1002\/mp.17758","type":"journal-article","article-title":"Commissioning of a precision preclinical 200 kV x-ray irradiator based on modular adaptations","volume":"52","author":"Wolf","year":"2025","journal-title":"Med. Phys."},{"key":"bpexae3b48bib34","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aadf2b","type":"journal-article","article-title":"Fabrication of an anthropomorphic heterogeneous mouse phantom for multimodality medical imaging","volume":"63","author":"Zhang","year":"2018","journal-title":"Phys. Med. Biol."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3b48","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3b48\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3b48","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3b48\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3b48\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3b48\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3b48\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3b48\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T14:47:29Z","timestamp":1770216449000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae3b48"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,1]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,2,4]]},"published-print":{"date-parts":[[2026,2,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae3b48","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,1]]},"assertion":[{"value":"Local artificial body for radiation analysis and testing (LABRAT\n                      \u00ae\n                      ): additive manufacturing and dosimetric measurements of a heterogeneous mouse model phantom for pre-clinical radiation research","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2025-10-15","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-01-20","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-02-04","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}