{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T18:02:03Z","timestamp":1791482523748,"version":"4.3.4"},"reference-count":35,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":8,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"tdm","delay-in-days":8,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Joint Funds for the Innovation of Science and Technology of Fujian Province","award":["2021Y9190"],"award-info":[{"award-number":["2021Y9190"]}]},{"name":"Fujian Provincial Department of Science and Technology University Industry University Research Joint Innovation Project","award":["2023Y4019"],"award-info":[{"award-number":["2023Y4019"]}]},{"name":"Open Project of the Laboratory of Clinical Applied Anatomy, Fujian Medical University","award":["2025LCAA01"],"award-info":[{"award-number":["2025LCAA01"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Accurate needle placement is critical in percutaneous thoracoabdominal interventions. Conventional CT-guided procedures are limited by iterative scans, operator-dependent variability, and two-dimensional visualization. This preclinical study evaluates a novel display-based augmented reality (AR) navigation system integrating virtual-to-real registration via deltille grid position sensing (DGPS) markers for enhanced needle guidance. Experiments were conducted on a CIRS abdominal phantom with three operators: one expert interventional radiologist and two novices. Puncture accuracy, angular deviation, procedure time, and number of verification scans were assessed. AR guidance achieved first-pass distance errors of 1.50 (0.46) mm for the expert and 1.66 (0.50) mm and 1.58 (1.06) mm for novices, with angular deviations of 1.41\u00b0, 1.30\u00b0, and 1.39\u00b0, respectively. No significant operator-related differences were observed. Compared with conventional step-and-shoot CT guidance, AR guidance reduced the first-pass and final-pass targeting error, while conventional CT guidance relies on iterative scan\u2013adjust\u2013advance steps to achieve acceptable final accuracy, with AR reducing intermediate re-scans while retaining a single final verification scan. The findings indicate that AR navigation enhances first-pass precision, reduces procedural variability, and improves workflow efficiency, supporting its potential clinical value for more consistent and efficient minimally invasive interventions.<\/jats:p>","DOI":"10.1088\/2057-1976\/ae5827","type":"journal-article","created":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T22:47:50Z","timestamp":1774651670000},"page":"025064","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Display-based augmented reality navigation for CT-Guided thoracoabdominal punctures: phantom study of accuracy and workflow efficiency"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4496-507X","authenticated-orcid":true,"given":"Jihong","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-0517-4302","authenticated-orcid":true,"given":"Tiansheng","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaolong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuhui","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Penggang","family":"Bai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bingwei","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3350-2210","authenticated-orcid":true,"given":"Zhuting","family":"Fang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,4,9]]},"reference":[{"key":"bpexae5827bib1","doi-asserted-by":"publisher","first-page":"99","DOI":"10.22575\/interventionalradiology.2024-0003","type":"journal-article","article-title":"Innovative techniques for image-guided percutaneous puncture: navigating complex cases for successful outcomes","volume":"9","author":"Yasumoto","year":"2024","journal-title":"Interventional Radiology (Higashimatsuyama-shi (Japan)"},{"key":"bpexae5827bib2","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1148\/radiol.2021203715","type":"journal-article","article-title":"Consensus guidelines for the definition of time-to-event end points in image-guided tumor ablation: results of the SIO and DATECAN initiative","volume":"301","author":"Puijk","year":"2021","journal-title":"Radiology"},{"key":"bpexae5827bib3","doi-asserted-by":"publisher","first-page":"83","DOI":"10.22575\/interventionalradiology.2021-0012","type":"journal-article","article-title":"Computed Tomography-guided lung biopsy: a review of techniques for reducing the incidence of complications","volume":"6","author":"Nakamura","year":"2021","journal-title":"Interventional Radiology (Higashimatsuyama-shi (Japan)"},{"key":"bpexae5827bib4","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1007\/s11548-022-02766-1","type":"journal-article","article-title":"Robotic system for accurate percutaneous puncture guided by 3D-2D ultrasound","volume":"18","author":"Lin","year":"2023","journal-title":"Int. J. Comput Assist. Radiol. Surg."},{"key":"bpexae5827bib5","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1001\/jamainternmed.2025.0505","type":"journal-article","article-title":"Projected lifetime cancer risks from current computed tomography imaging","volume":"185","author":"Smith-Bindman","year":"2025","journal-title":"JAMA Intern. Med."},{"key":"bpexae5827bib6","doi-asserted-by":"publisher","first-page":"4160","DOI":"10.1002\/mp.15008","type":"journal-article","article-title":"Diffeomorphic respiratory motion estimation of thoracoabdominal organs for image-guided interventions","volume":"48","author":"Lei","year":"2021","journal-title":"Med. Phys."},{"key":"bpexae5827bib7","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1146\/annurev-vision-111022-123758","type":"journal-article","article-title":"The perceptual science of augmented reality","volume":"9","author":"Cooper","year":"2023","journal-title":"Annu. Rev. Vis. Sci."},{"key":"bpexae5827bib8","doi-asserted-by":"publisher","DOI":"10.2196\/25499","type":"journal-article","article-title":"Virtual and augmented reality applications in medicine: analysis of the scientific literature","volume":"23","author":"Yeung","year":"2021","journal-title":"J. Med. Internet Res."},{"key":"bpexae5827bib9","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1186\/s12938-023-01138-3","type":"journal-article","article-title":"Virtual and augmented reality in biomedical engineering","volume":"22","author":"Taghian","year":"2023","journal-title":"Biomed. Eng. Online"},{"key":"bpexae5827bib10","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.1007\/s00464-019-06862-3","type":"journal-article","article-title":"Effectiveness of the HoloLens mixed-reality headset in minimally invasive surgery: a simulation-based feasibility study","volume":"34","author":"","year":"2020","journal-title":"Surgical Endoscopy"},{"key":"bpexae5827bib11","doi-asserted-by":"publisher","DOI":"10.1148\/rycan.230154","type":"journal-article","article-title":"Augmented reality for surgical navigation: a review of advanced needle guidance systems for percutaneous tumor ablation","volume":"7","author":"Evans","year":"2025","journal-title":"Radiol. Imaging Cancer"},{"key":"bpexae5827bib12","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.1007\/s00270-025-04044-4","type":"journal-article","article-title":"Integrated needle guide on smartphone for percutaneous interventions using augmented reality","volume":"48","author":"Saccenti","year":"2025","journal-title":"Cardiovasc. Intervent Radiol."},{"key":"bpexae5827bib13","doi-asserted-by":"publisher","DOI":"10.1186\/s41747-019-0129-y","type":"journal-article","article-title":"Ultrasound-guided interventions with augmented reality in situ visualisation: a proof-of-mechanism phantom study","volume":"4","author":"Farshad-Amacker","year":"2020","journal-title":"Eur. Radiol. Exp."},{"key":"bpexae5827bib14","doi-asserted-by":"publisher","first-page":"2411","DOI":"10.1007\/s11548-024-03112-3","type":"journal-article","article-title":"Evaluation of augmented reality training for a navigation device used for CT-guided needle placement","volume":"19","author":"Stauffer","year":"2024","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"bpexae5827bib15","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/j.jvir.2022.10.027","type":"journal-article","article-title":"An ergonomic holographic procedural monitor for thyroid radiofrequency ablation using a mixed-reality headset","volume":"34","author":"Park","year":"2023","journal-title":"Journal of Vascular and Interventional Radiology : JVIR"},{"key":"bpexae5827bib16","doi-asserted-by":"publisher","first-page":"936","DOI":"10.1055\/a-2416-1080","type":"journal-article","article-title":"Acceptance and feasibility of an augmented reality-based navigation system with optical tracking for percutaneous procedures in interventional radiology - a simulation-based phantom study","volume":"197","author":"Rohmer","year":"2025","journal-title":"RoFo: Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin"},{"key":"bpexae5827bib17","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1016\/j.jvir.2023.10.005","type":"journal-article","article-title":"Smartphone augmented reality outperforms conventional CT guidance for composite ablation margins in phantom models","volume":"35","author":"Lee","year":"2024","journal-title":"Journal of Vascular and Interventional Radiology : JVIR"},{"key":"bpexae5827bib18","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1177\/29941520251377069","type":"journal-article","article-title":"Augmented reality in interventional radiology: a review of systems, ergonomics, applications, and outcomes","volume":"2","author":"Ghosn","year":"2025","journal-title":"J. Med. Ext. Real"},{"key":"bpexae5827bib19","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.jmir.2023.12.006","type":"journal-article","article-title":"The applications of augmented reality in image-guided tumor ablations: a scoping review","volume":"55","author":"Al-Naser","year":"2024","journal-title":"J. Med. Imaging Radiat. Sci."},{"key":"bpexae5827bib20","doi-asserted-by":"publisher","first-page":"3156","DOI":"10.1007\/s00330-023-09467-6","type":"journal-article","article-title":"Improving puncture accuracy in percutaneous CT-guided needle insertion with wireless inertial measurement unit: a phantom study","volume":"33","author":"Lin","year":"2023","journal-title":"Eur. Radiol."},{"key":"bpexae5827bib21","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1049\/htl.2018.5076","type":"journal-article","article-title":"Concepts for augmented reality visualisation to support needle guidance inside the MRI","volume":"5","author":"Mewes","year":"2018","journal-title":"Healthc. Technol. Lett."},{"key":"bpexae5827bib22","doi-asserted-by":"publisher","first-page":"3709","DOI":"10.1002\/mp.13645","type":"journal-article","article-title":"Design and validation of a surgical navigation system for brachytherapy based on mixed reality","volume":"46","author":"Zhou","year":"2019","journal-title":"Med. Phys."},{"key":"bpexae5827bib23","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s11548-024-03148-5","type":"journal-article","article-title":"Smart goggles augmented reality CT-US fusion compared to conventional fusion navigation for percutaneous needle insertion","volume":"20","author":"Borde","year":"2025","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"bpexae5827bib24","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1186\/s13063-024-08628-2","type":"journal-article","article-title":"Mixed reality-assisted versus landmark-guided spinal puncture in elderly patients: protocol for a stratified randomized controlled trial","volume":"25","author":"Gao","year":"2024","journal-title":"Trials"},{"key":"bpexae5827bib25","doi-asserted-by":"publisher","first-page":"18620","DOI":"10.1038\/s41598-020-75676-4","type":"journal-article","article-title":"Augmented reality improves procedural efficiency and reduces radiation dose for CT-guided lesion targeting: a phantom study using HoloLens 2","volume":"10","author":"Park","year":"2020","journal-title":"Sci. Rep."},{"key":"bpexae5827bib26","doi-asserted-by":"publisher","first-page":"78","DOI":"10.4103\/ams.ams_45_24","type":"journal-article","article-title":"Augmented reality in temporomandibular joint arthrocentesis\u2014an evaluative clinical study","volume":"15","author":"Shah","year":"2025","journal-title":"Annals of Maxillofacial Surgery"},{"key":"bpexae5827bib27","doi-asserted-by":"publisher","first-page":"1921","DOI":"10.1007\/s11548-020-02235-7","type":"journal-article","article-title":"Smartphone- versus smartglasses-based augmented reality (AR) for percutaneous needle interventions: system accuracy and feasibility study","volume":"15","author":"Li","year":"2020","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"bpexae5827bib28","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1007\/s00270-019-02403-6","type":"journal-article","article-title":"Smartphone augmented reality CT-based platform for needle insertion guidance: a phantom study","volume":"43","author":"Hecht","year":"2020","journal-title":"Cardiovasc. Intervent. Radiol."},{"key":"bpexae5827bib29","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acaf23","type":"journal-article","article-title":"Visualization, registration and tracking techniques for augmented reality guided surgery: a review","volume":"68","author":"Ma","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"bpexae5827bib30","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2021.104663","type":"journal-article","article-title":"A fully automatic surgical registration method for percutaneous abdominal puncture surgical navigation","volume":"136","author":"Li","year":"2021","journal-title":"Comput. Biol. Med."},{"key":"bpexae5827bib31","doi-asserted-by":"publisher","first-page":"4554","DOI":"10.1002\/mp.17243","type":"journal-article","article-title":"Rigid point cloud registration based on correspondence cloud for image-to-patient registration in image-guided surgery","volume":"51","author":"Li","year":"2024","journal-title":"Med. Phys."},{"key":"bpexae5827bib32","doi-asserted-by":"publisher","first-page":"5849","DOI":"10.1109\/TPAMI.2022.3212862","type":"journal-article","article-title":"HydraMarker: efficient, flexible, and multifold marker field generation","volume":"45","author":"Zhu","year":"2023","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"bpexae5827bib33","doi-asserted-by":"publisher","first-page":"107216","DOI":"10.1016\/j.bspc.2024.107216","type":"journal-article","article-title":"Efficient contact-based registration for minimally invasive anterior hip arthroplasty","volume":"102","author":"Xie","year":"2025","journal-title":"Biomed. Signal Process. Control"},{"key":"bpexae5827bib34","doi-asserted-by":"publisher","first-page":"2280","DOI":"10.1016\/j.patcog.2014.01.005","type":"journal-article","article-title":"Automatic generation and detection of highly reliable fiducial markers under occlusion","volume":"47","author":"Garrido-Jurado","year":"2014","journal-title":"Pattern Recognit."},{"key":"bpexae5827bib35","doi-asserted-by":"publisher","first-page":"207","DOI":"10.2214\/AJR.17.18498","type":"journal-article","article-title":"Smartphone-guided needle angle selection during CT-Guided procedures","volume":"210","author":"Xu","year":"2018","journal-title":"AJR. American Journal of Roentgenology"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5827","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5827\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5827","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5827\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5827\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5827\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5827\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5827\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T12:57:24Z","timestamp":1775739444000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5827"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,1]]},"references-count":35,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,4,9]]},"published-print":{"date-parts":[[2026,4,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae5827","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,1]]},"assertion":[{"value":"Display-based augmented reality navigation for CT-Guided thoracoabdominal punctures: phantom study of accuracy and workflow efficiency","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2025-11-25","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-03-27","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-04-09","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}