{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T05:03:57Z","timestamp":1775797437240,"version":"3.50.1"},"reference-count":32,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":8,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"tdm","delay-in-days":8,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Faculty of Sciences and Mathematics, Diponegoro University","award":["23.B\/UN7.F8\/PP\/II\/2025"],"award-info":[{"award-number":["23.B\/UN7.F8\/PP\/II\/2025"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The purpose of this study is to develop software for automatic low-contrast objects segmentation in the ACR 464 computed tomography (CT) phantom and to evaluate the quantitative effect of radiation dose and object size on low-contrast detectability (LCD). The software was developed using MATLAB R2013a. The anchor coordinate of the largest low-contrast object (25 mm) was determined statistically by rotating a region of interest (ROI) of identical size over 360\u00b0 in 1\u00b0 angular increments to identify the coordinate corresponding to the maximum CT number. Meanwhile, the center of the phantom was determined based on a threshold-based method. The two center coordinates were used as references for detecting other low-contrast objects using a template matching. Regions of interests (ROIs) were automatically located within low-contrast objects and in the background, which is at the center of the phantom\u2019s image. Mean CT number, noise, contrast, and contrast-to-noise ratio (CNR) were subsequently computed. The low-contrast object detectability threshold was defined as a CNR cut-off of 1. The robustness of the anchor coordinate determination algorithm was evaluated across a range of imaging conditions, specifically targeting scenarios involving extreme noise levels and image tilting. Testing of the algorithm system was carried out on images scanned with various volume CT dose indexes (CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    s) of 21.4, 26.8, 32.1, 37.5, 42.8, and 53.6 mGy. The results were compared with a manual method (using micro DICOM viewer software) and statistical analysis of paired sample t-test between the results of automatic and manual methods was carried out. The results obtained using the automated methods indicate that the minimum resolved object sizes were 5, 5, 4, 4, 4, and 4 mm at CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    values of 21.6, 26.8, 32.1, 37.5, 42.8, and 53.6 mGy, respectively. In comparison, the manual method yielded minimum resolved object sizes of 5, 5, 5, 4, 4, and 4 mm across the same CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    levels, demonstrating a slight improvement in resolution for the automated approach at the 32.1 mGy dose level. An increase in CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    affected the increase in CNR. In conclusion, an automatic method for detecting low-contrast objects in the ACR 464 CT phantom was successfully completed. Low-contrast objects segmentation was shown to be accurate in test images.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ae5970","type":"journal-article","created":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T22:48:46Z","timestamp":1774997326000},"page":"025063","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A method for automatic low-contrast object segmentation for low-contrast detectability in CT images"],"prefix":"10.1088","volume":"12","author":[{"given":"Rahmat","family":"Riyadi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0156-6797","authenticated-orcid":true,"given":"Choirul","family":"Anam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7119-9633","authenticated-orcid":true,"given":"Heri","family":"Sutanto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4218-6259","authenticated-orcid":true,"given":"Ariij","family":"Naufal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7077-439X","authenticated-orcid":true,"given":"Riska","family":"Amilia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geoff","family":"Dougherty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"266","published-online":{"date-parts":[[2026,4,9]]},"reference":[{"key":"bpexae5970bib1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13719","type":"journal-article","article-title":"Automated development of the contrast\u2013detail curve based on statistical low-contrast detectability in CT images","volume":"23","author":"Anam","year":"2022","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae5970bib2","doi-asserted-by":"publisher","first-page":"26","DOI":"10.3390\/medsci8030026","type":"journal-article","article-title":"The feasibility of contrast-to-noise ratio on measurements to evaluate CT image quality in terms of low-contrast detailed detectability","volume":"8","author":"Alsleem","year":"2020","journal-title":"Med. Sci."},{"key":"bpexae5970bib3","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1118\/1.3577757","type":"journal-article","article-title":"Automated assessment of low contrast sensitivity for CT systems using a model observer","volume":"38","author":"Hernandez-Giron","year":"2011","journal-title":"Med. Phys."},{"key":"bpexae5970bib4","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ae0ab0","type":"journal-article","article-title":"Automated computation of detectability index and generation of contrast\u2013detail curves for CT protocol optimization","volume":"70","author":"Anam","year":"2025","journal-title":"Phys. Med. Biol."},{"key":"bpexae5970bib5","doi-asserted-by":"publisher","first-page":"9","DOI":"10.3233\/XST-2007-00168","type":"journal-article","article-title":"Novel materials for low-contrast phantoms for computed tomography","volume":"15","author":"Allert","year":"2007","journal-title":"J. Xray. Sci. Technol."},{"key":"bpexae5970bib6","doi-asserted-by":"publisher","first-page":"2552","DOI":"10.1007\/s00330-019-06635-5","type":"journal-article","article-title":"Physical evaluation of an ultra-high-resolution CT scanner","volume":"30","author":"Oostveen","year":"2020","journal-title":"Eur. Radiol."},{"key":"bpexae5970bib7","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1148\/radiol.2015141260","type":"journal-article","article-title":"Evaluation of low-contrast detectability of iterative reconstruction across multiple institutions, CT scanner manufacturers, and radiation exposure levels","volume":"277","author":"Saiprasad","year":"2015","journal-title":"Radiology"},{"key":"bpexae5970bib8","doi-asserted-by":"publisher","first-page":"1054","DOI":"10.1002\/mp.14657","type":"journal-article","article-title":"Rapid measurement of the low contrast detectability of CT scanners","volume":"48","author":"Omigbodun","year":"2021","journal-title":"Med. Phys."},{"key":"bpexae5970bib9","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.1016\/j.ejrnm.2016.08.016","type":"journal-article","article-title":"Quality control of CT image using American College of Radiology (ACR) phantom","volume":"47","author":"Mansour","year":"2016","journal-title":"Egypt. J. Radiol. Nucl. Med."},{"key":"bpexae5970bib10","doi-asserted-by":"publisher","first-page":"2423","DOI":"10.1118\/1.1769632","type":"journal-article","article-title":"The phantom portion of the American College of radiology (ACR) computed tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoid","volume":"31","author":"McCollough","year":"2004","journal-title":"Med. Phys."},{"key":"bpexae5970bib11","type":"journal-article","article-title":"Evaluation of low contrast detectability performance using two-alternative forced choice method on computed tomography dose reduction algorithms","volume":"8318","author":"Fan","year":"2012","journal-title":"Proc. SPIE"},{"key":"bpexae5970bib12","type":"journal-article","article-title":"Correlation between model observers in uniform background and human observer in patient liver background for a low-contrast detection task in CT","volume":"10577","author":"Gong","year":"2018","journal-title":"Proc. SPIE Int. Soc. Opt. Eng."},{"key":"bpexae5970bib13","doi-asserted-by":"publisher","first-page":"7671","DOI":"10.1088\/0031-9155\/60\/19\/7671","type":"journal-article","article-title":"On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT","volume":"60","author":"Zhou","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"bpexae5970bib14","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.3.3.035506","type":"journal-article","article-title":"Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography","volume":"3","author":"Solomon","year":"2016","journal-title":"J. Med. Imaging (Bellingham)"},{"key":"bpexae5970bib15","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1093\/rpd\/ncq069","type":"journal-article","article-title":"Evaluation of subjective assessment of the low-contrast visibility in constancy control of computed tomography","volume":"139","author":"Thilander-Klang","year":"2010","journal-title":"Radiat. Prot. Dosimetry"},{"key":"bpexae5970bib16","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ad90e9","type":"journal-article","article-title":"A statistical-based automatic detection of a low-contrast object in the ACR CT phantom for measuring contrast-to-noise ratio of CT images","volume":"11","author":"Anam","year":"2025","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexae5970bib17","doi-asserted-by":"publisher","first-page":"637","DOI":"10.32628\/IJSRST241161115","type":"journal-article","article-title":"An algorithm for automatic low-contrast detection system and its evaluation for images with various phantom rotations","volume":"11","author":"Riyadi","year":"2024","journal-title":"Int. J. Sci. Res. Sci. Technol."},{"key":"bpexae5970bib18","doi-asserted-by":"crossref","DOI":"10.1063\/5.0228091","type":"journal-article","article-title":"Evaluation of IndoQCT for automatic measurement of contrast-to-noise ratio (CNR) on American college of radiology (ACR) CT phantom images","volume":"3210","author":"Novitasari","year":"2024","journal-title":"AIP Conf. Proc."},{"key":"bpexae5970bib19","doi-asserted-by":"publisher","first-page":"175","DOI":"10.3390\/jimaging11060175","type":"journal-article","article-title":"Performance of a statistical-based automatic contrast-to-noise ratio measurement on images of the ACR CT phantom","volume":"11","author":"Anam","year":"2025","journal-title":"J. Imaging"},{"key":"bpexae5970bib20","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1016\/j.ejmp.2014.01.006","type":"journal-article","article-title":"How to measure CT image quality: Variations in CT-numbers, uniformity and low contrast resolution for a CT quality assurance phantom","volume":"30","author":"Gulliksrud","year":"2014","journal-title":"Phys. Med."},{"key":"bpexae5970bib21","doi-asserted-by":"publisher","first-page":"219","DOI":"10.22159\/ajpcr.2017.v10i6.17719","type":"journal-article","article-title":"Effectiveness of gluteal muscle strengthening on flat foot","volume":"10","author":"Mulchandani","year":"2017","journal-title":"Asian J. Pharm. Clin. Res."},{"key":"bpexae5970bib22","doi-asserted-by":"publisher","first-page":"32","DOI":"10.18502\/fid.v19i32.10804","type":"journal-article","article-title":"The effect of different field of view sizes on contrast-to-noise ratio of cone-beam computed tomography units: an in-vitro study","volume":"19","author":"Niktash","year":"2022","journal-title":"Front. Dent."},{"key":"bpexae5970bib23","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1016\/j.oooo.2012.08.436","type":"journal-article","article-title":"Contrast-to-noise ratio with different large volumes in a cone-beam computerized tomography machine: an in vitro study","volume":"114","author":"Bechara","year":"2012","journal-title":"Oral. Surg. Oral. Med. Oral. Pathol. Oral. Radiol."},{"key":"bpexae5970bib24","type":"journal-article","article-title":"Blind CT image quality assessment via deep learning strategy: initial study","volume":"10577","author":"Li","year":"2018","journal-title":"Proc. SPIE"},{"key":"bpexae5970bib25","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1520\/SSMS20180042","type":"journal-article","article-title":"Utilizing detector filters for noise reduction in x-ray computer tomography scanning for the inspection of the structural integrity of additive manufactured metal parts","volume":"3","author":"Tawfik","year":"2019","journal-title":"Smart Sustain. Manuf. Syst."},{"key":"bpexae5970bib26","doi-asserted-by":"publisher","first-page":"2553","DOI":"10.1118\/1.2761366","type":"journal-article","article-title":"TU-D-L100J-02: Noise stationarity in spiral CT","volume":"34","author":"Whiting","year":"2007","journal-title":"Med. Phys."},{"key":"bpexae5970bib27","doi-asserted-by":"publisher","first-page":"182","DOI":"10.2174\/1573405618666220404162241","type":"journal-article","article-title":"Low-dose COVID-19 CT image denoising using CNN and its method noise thresholding","volume":"19","author":"Diwakar","year":"2023","journal-title":"Curr. Med. Imaging"},{"key":"bpexae5970bib28","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.20190336","type":"journal-article","article-title":"Relationship between CNR and visibility of anatomical structures of cone-beam computed tomography images under different exposure parameters","volume":"49","author":"Wang","year":"2020","journal-title":"Dentomaxillofac. Radiol."},{"key":"bpexae5970bib29","doi-asserted-by":"publisher","first-page":"61","DOI":"10.55981\/aij.2023.1228","type":"journal-article","article-title":"The quantitative effect of noise and object diameter on low-contrast detectability of AAPM CT performance phantom images","volume":"49","author":"Setiawati","year":"2023","journal-title":"Atom Indonesia"},{"key":"bpexae5970bib30","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1148\/radiol.15142005","type":"journal-article","article-title":"Diagnostic performance of an advanced modeled iterative reconstruction algorithm for low-contrast detectability with a third-generation dual-source multidetector CT scanner: potential for radiation dose reduction in a multireader study","volume":"275","author":"Solomon","year":"2015","journal-title":"Radiology"},{"key":"bpexae5970bib31","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.70352","type":"journal-article","article-title":"Automated measurement of detectability index in CT imaging: Development and validation","volume":"26","author":"Anam","year":"2025","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae5970bib32","doi-asserted-by":"publisher","DOI":"10.1002\/mp.70239","type":"journal-article","article-title":"Development and implementation of a smooth d\u2032-based contrast-detail curve for CT imaging protocol optimization in liver examination","volume":"53","author":"Anam","year":"2026","journal-title":"Med. Phys."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5970","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5970\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5970","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5970\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5970\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5970\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5970\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5970\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T04:19:39Z","timestamp":1775794779000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae5970"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,1]]},"references-count":32,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,4,9]]},"published-print":{"date-parts":[[2026,4,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae5970","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,1]]},"assertion":[{"value":"A method for automatic low-contrast object segmentation for low-contrast detectability in CT images","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2025-10-22","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-03-31","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-04-09","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}