{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,8]],"date-time":"2026-11-08T17:18:38Z","timestamp":1794158318732,"version":"4.8.0"},"reference-count":26,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T00:00:00Z","timestamp":1780617600000},"content-version":"vor","delay-in-days":4,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T00:00:00Z","timestamp":1780617600000},"content-version":"tdm","delay-in-days":4,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Science and Technology Achievement Transformation Guidance Special Project of Shanxi Province","award":["202204021301052"],"award-info":[{"award-number":["202204021301052"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["52371079"],"award-info":[{"award-number":["52371079"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Patent Transformation Project of Shanxi Province","award":["202304004"],"award-info":[{"award-number":["202304004"]}]},{"DOI":"10.13039\/501100013317","name":"Key Research and Development Program of Shanxi Province","doi-asserted-by":"crossref","award":["202302120401006"],"award-info":[{"award-number":["202302120401006"]}],"id":[{"id":"10.13039\/501100013317","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Ti-6Al-4 V dental implants are widely used because of their excellent biocompatibility and mechanical strength; however, their high elastic modulus relative to jawbone may cause stress shielding and peri-implant bone resorption. To improve biomechanical compatibility, this study introduced a gradient-regulated porous design into dental implants. A three-dimensional mandibular model was reconstructed from CT image data using reverse engineering techniques. Based on Gibson-Ashby theory, several porous architectures with a unified external octet-truss framework but different internal topologies were established, including orthogonally intersecting plates (structure 1), face-diagonal oblique plates (structure 2), an inner octahedral topology (structure 3), and the original octet-truss structure as the reference configuration. At a fixed porosity of 65%, the effects of key geometric parameters, including strut diameter and hole diameter, on the equivalent elastic modulus and bending response of these porous structures were systematically investigated by finite element analysis, and axial compression and bending simulations were combined to screen candidate structures. The results showed that structure 3 exhibited the lowest equivalent elastic modulus (16.92\u201319.42 GPa). In particular, structure 3(c), with a strut diameter of 0.12 mm and a hole diameter of 0.2 mm, achieved an equivalent elastic modulus of 17.00 GPa, which was 21.73% lower than that of the original octet-truss structure (21.72 GPa). Under bending loading, its magnitude of displacement was 0.014 mm, close to that of the original octet-truss structure (0.0138 mm), indicating that stiffness reduction was achieved without an obvious loss of bending stability. To further address the limited geometric adaptability of conventional regular lattices, a unit-cell-based conformal filling strategy was proposed to generate a plate-lattice porous implant matching the contour of a 5 mm diameter implant. Finally, analysis under clinically relevant occlusal loading conditions showed that the porous implant model exhibited a favorable stress-transfer pattern, promoted a relatively uniform stress distribution in the surrounding bone, and improved displacement compatibility at the bone-implant interface. These findings provide theoretical support for the structural design of porous dental implants and offer a useful basis for further structural optimization and biomechanical adaptation.<\/jats:p>","DOI":"10.1088\/2057-1976\/ae7379","type":"journal-article","created":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T22:48:19Z","timestamp":1779922099000},"page":"035066","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["A finite element analysis of a dental implant with a conformal lattice structure: a parametric exploration under occlusal loading"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-1695-8180","authenticated-orcid":true,"given":"Hao","family":"Zheng","sequence":"first","affiliation":[{"name":"North University of China"},{"name":"North University of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6142-9754","authenticated-orcid":true,"given":"Wei","family":"Liu","sequence":"additional","affiliation":[{"name":"North University of China"},{"name":"North University of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuepeng","family":"Yan","sequence":"additional","affiliation":[{"name":"North University of China"},{"name":"North University of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruifeng","family":"Zhao","sequence":"additional","affiliation":[{"name":"North University of China"},{"name":"North University of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Gao","sequence":"additional","affiliation":[{"name":"North University of China"},{"name":"North University of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuxin","family":"Li","sequence":"additional","affiliation":[{"name":"North University of China"},{"name":"North University of China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,6,5]]},"reference":[{"key":"bpexae7379bib1","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1111\/prd.12291","type":"journal-article","article-title":"Effects of occlusal forces on the peri-implant-bone interface stability","volume":"81","author":"Delgado-ruiz","year":"2019","journal-title":"Periodontology"},{"key":"bpexae7379bib2","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.ijom.2014.10.023","type":"journal-article","article-title":"Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic review","volume":"44","author":"Moraschini","year":"2015","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"bpexae7379bib3","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.mser.2004.11.001","type":"journal-article","article-title":"Surface modification of titanium, titanium alloys, and related materials for biomedical applications","volume":"47","author":"Liu","year":"2004","journal-title":"Mater. Sci. Eng. R Rep"},{"key":"bpexae7379bib4","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.1007\/s12598-020-01413-5","type":"journal-article","article-title":"Preparation and surface modification of 3D printed Ti-6Al-4V porous implant","volume":"40","author":"Liang","year":"2021","journal-title":"Rare Met."},{"key":"bpexae7379bib5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/ma15207172","type":"journal-article","article-title":"Laser-deposited beta type Ti-42Nb alloy with anisotropic mechanical properties for pioneering biomedical implants with a very low elastic modulus","volume":"15","author":"Arias-gonz\u00e1lez","year":"2022","journal-title":"Materials"},{"key":"bpexae7379bib6","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2025.110318","type":"journal-article","article-title":"A biomechanical assessment of dental implant stability under the effect of changes in bone remodeling factors and implant elastic modulus","volume":"192","author":"Jafariandehkordi","year":"2025","journal-title":"Comput. Biol. Med."},{"key":"bpexae7379bib7","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.actbio.2015.11.013","type":"journal-article","article-title":"3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface","volume":"30","author":"Shah","year":"2016","journal-title":"Acta Biomater."},{"key":"bpexae7379bib8","doi-asserted-by":"publisher","first-page":"4178","DOI":"10.1021\/acsabm.3c00403","type":"journal-article","article-title":"3D printing of Ti-6Al-4V-based porous-channel dental implants: computational, biomechanical, and cytocompatibility analyses","volume":"6","author":"Chakraborty","year":"2023","journal-title":"ACS Appl. Bio Mater."},{"key":"bpexae7379bib9","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1016\/j.jds.2024.11.024","type":"journal-article","article-title":"Optimizing dental implant design: structure, strength, and bone ingrowth","volume":"20","author":"Chang","year":"2025","journal-title":"J. Dent. Sci."},{"key":"bpexae7379bib10","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1016\/j.matdes.2013.01.038","type":"journal-article","article-title":"Mechanical properties of a Ti6Al4V porous structure produced by selective laser melting","volume":"49","author":"Sun","year":"2013","journal-title":"Mater. Des."},{"key":"bpexae7379bib11","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.jmrt.2025.09.112","type":"journal-article","article-title":"Mechanical performance of titanium alloy dental implants with continuously gradient porous structures","volume":"39","author":"Xiao","year":"2025","journal-title":"J. Mater. Res. Technol."},{"key":"bpexae7379bib12","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1038\/s44334-025-00057-6","type":"journal-article","article-title":"Additively manufactured metallic TPMS lattice structures: design strategies, fabrication, multifunctional properties, and applications","volume":"2","author":"Li","year":"2025","journal-title":"npj Adv. Manuf."},{"key":"bpexae7379bib13","doi-asserted-by":"publisher","first-page":"54","DOI":"10.3390\/jfb16020054","type":"journal-article","article-title":"Hybrid biomechanical design of dental implants: integrating solid and gyroid triply periodic minimal surface lattice architectures for optimized stress distribution","volume":"16","author":"Alemayehu","year":"2025","journal-title":"J. Funct. Biomater."},{"key":"bpexae7379bib14","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1515\/bmt-2025-0159","type":"journal-article","article-title":"Optimized design of porous dental implant structures based on triply periodic minimal surface (TPMS)","volume":"70","author":"Chen","year":"2025","journal-title":"Biomed. Eng."},{"key":"bpexae7379bib15","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s40729-025-00618-6","type":"journal-article","article-title":"Spatially distributed and interconnected porous architectures for dental implants","volume":"11","author":"Dabaja","year":"2025","journal-title":"Int. J. Implant Dent."},{"key":"bpexae7379bib16","doi-asserted-by":"publisher","first-page":"886","DOI":"10.3390\/polym17070886","type":"journal-article","article-title":"Application of 3D printing technology in dentistry: a review","volume":"17","author":"Chen","year":"2025","journal-title":"Polymers"},{"key":"bpexae7379bib17","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1080\/10255842.2023.2199901","type":"journal-article","article-title":"Porous structure design and properties of dental implants","volume":"27","author":"Zhang","year":"2024","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"bpexae7379bib18","author":"Gibson","year":"1999","type":"book"},{"key":"bpexae7379bib19","doi-asserted-by":"publisher","first-page":"2626","DOI":"10.1016\/j.jmrt.2023.01.155","type":"journal-article","article-title":"Research progress on the design and performance of porous titanium alloy bone implants","volume":"23","author":"Song","year":"2023","journal-title":"J. Mater. Res. Technol."},{"key":"bpexae7379bib20","doi-asserted-by":"publisher","DOI":"10.1016\/j.addma.2023.103406","type":"journal-article","article-title":"Development of conformal shell lattices via laser powder bed fusion and unraveling their mechanical responses via modeling and experiments","volume":"62","author":"Fu","year":"2023","journal-title":"Addit. Manuf."},{"key":"bpexae7379bib21","doi-asserted-by":"publisher","DOI":"10.1080\/17452759.2024.2449569","type":"journal-article","article-title":"Elastically isotropic auxetic and zero-Poisson\u2019s ratio TPMS-based metamaterials","volume":"20","author":"Daynes","year":"2025","journal-title":"Virtual Phys. Prototyp."},{"key":"bpexae7379bib22","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1016\/j.dental.2023.04.002","type":"journal-article","article-title":"Finite element analysis in implant dentistry: state of the art and future directions","volume":"39","author":"Falcinelli","year":"2023","journal-title":"Dent. Mater."},{"key":"bpexae7379bib23","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1080\/10255842.2023.2300686","type":"journal-article","article-title":"Mechanical property of Ti6Al4V cylindrical porous structure for dental implants fabricated by selective laser melting","volume":"28","author":"Zhai","year":"2025","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"bpexae7379bib24","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1080\/10255842.2012.688110","type":"journal-article","article-title":"Importance of diameter-to-length ratio in selecting dental implants: a methodological finite element study","volume":"17","author":"Demenko","year":"2014","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"bpexae7379bib25","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1177\/0022034511417442","type":"journal-article","article-title":"Ultimate masticatory force as a criterion in implant selection","volume":"90","author":"Demenko","year":"2011","journal-title":"J. Dent. Res."},{"key":"bpexae7379bib26","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1111\/jopr.13333","type":"journal-article","article-title":"Marginal bone loss around machined smooth neck implants compared to rough threaded neck implants: a systematic review and meta\u2010analysis","volume":"30","author":"Zhang","year":"2021","journal-title":"J. Prosthodont."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae7379","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae7379\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae7379","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae7379\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae7379\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae7379\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae7379\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae7379\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T07:15:55Z","timestamp":1780643755000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae7379"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,1]]},"references-count":26,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,6,5]]},"published-print":{"date-parts":[[2026,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae7379","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,1]]},"assertion":[{"value":"A finite element analysis of a dental implant with a conformal lattice structure: a parametric exploration under occlusal loading","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-02-12","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-05-27","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-05","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}