{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T07:16:42Z","timestamp":1783322202100,"version":"3.54.6"},"reference-count":27,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T00:00:00Z","timestamp":1783296000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T00:00:00Z","timestamp":1783296000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    In this study, we present a simple, low dose, cost-effective slot scan diffraction imaging system compatible with slot-scan attenuation mammography to improve detection and localization of carcinoma. The system captures angle-resolved coherent scatter information to enhance tissue contrast beyond what is achievable with conventional imaging alone. Diffraction imaging, employed simultaneously with conventional attenuation imaging, has the potential to provide new information that could improve the sensitivity and specificity of diagnostic mammography. Performance was evaluated using small\n                    <jats:italic>ex-vivo<\/jats:italic>\n                    benign and cancerous human breast tissue samples. The detection of carcinoma embedded in benign tissue demonstrated the feasibility of this approach for distinguishing breast cancer from benign tissue with a setup that could be readily adapted into a clinically relevant system for diagnostic radiology.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ae80cf","type":"journal-article","created":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T22:47:47Z","timestamp":1782254867000},"page":"045005","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Development of x-ray slot scan diffraction imaging for detection of carcinoma"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-0375-1447","authenticated-orcid":false,"given":"Suman","family":"Gautam","sequence":"first","affiliation":[{"name":"University at Albany, SUNY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-0267-2239","authenticated-orcid":false,"given":"Arthur W","family":"Redgate","sequence":"additional","affiliation":[{"name":"University at Albany, SUNY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2492-0333","authenticated-orcid":true,"given":"Carolyn A","family":"MacDonald","sequence":"additional","affiliation":[{"name":"University at Albany, SUNY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8543-3398","authenticated-orcid":true,"given":"Jonathan C","family":"Petruccelli","sequence":"additional","affiliation":[{"name":"University at Albany, SUNY"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,7,6]]},"reference":[{"key":"bpexae80cfbib1","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1088\/0031-9155\/32\/6\/002","type":"journal-article","article-title":"X-ray characterisation of normal and neoplastic breast tissues","volume":"32","author":"Johns","year":"1987","journal-title":"Phys. Med. Biol."},{"key":"bpexae80cfbib2","doi-asserted-by":"publisher","first-page":"1791","DOI":"10.1088\/0031-9155\/44\/7\/316","type":"journal-article","article-title":"X-ray scatter signatures for normal and neoplastic breast tissues","volume":"44","author":"Kidane","year":"1999","journal-title":"Phys. Med. Biol."},{"key":"bpexae80cfbib3","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1117\/12.2008484","type":"journal-article","article-title":"Monte-Carlo simulations of a coded-aperture x-ray scatter imaging system for molecular imaging","volume":"8668","author":"Kapadia","year":"2013","journal-title":"Med. Imaging Phys. Med. Imaging"},{"key":"bpexae80cfbib4","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1117\/12.2216482","type":"journal-article","article-title":"Coded aperture coherent scatter imaging for breast cancer detection: a Monte Carlo evaluation","volume":"9783","author":"Lakshmanan","year":"2016b","journal-title":"Med. Imaging Phys. Med. Imaging"},{"key":"bpexae80cfbib5","doi-asserted-by":"publisher","first-page":"3773","DOI":"10.1088\/0031-9155\/54\/12\/011","type":"journal-article","article-title":"Monte Carlo simulation of x-ray scattering for quantitative characterization of breast cancer","volume":"54","author":"Elshemey","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"bpexae80cfbib6","doi-asserted-by":"publisher","first-page":"1581","DOI":"10.1109\/23.873019","type":"journal-article","article-title":"A Monte Carlo simulation study to investigate the potential of diffraction enhanced breast imaging","volume":"47","author":"Taibi","year":"2000","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"bpexae80cfbib7","doi-asserted-by":"publisher","first-page":"6151","DOI":"10.1088\/0031-9155\/52\/20\/005","type":"journal-article","article-title":"Correlation of energy dispersive diffraction signatures and microCT of small breast tissue samples with pathological analysis","volume":"52","author":"Griffiths","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"bpexae80cfbib8","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1063\/1.3478202","type":"journal-article","article-title":"Identification of molecular structures of normal and pathological human breast tissue using synchrotron radiation","volume":"1266","author":"Concei\u00e7\u00e3o","year":"2010","journal-title":"AIP Conf. Proc."},{"key":"bpexae80cfbib9","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/S0168-9002(03)02130-2","type":"journal-article","article-title":"Evaluation of a novel low light level (L3 vision) CCD technology for application to diffraction enhanced breast imaging","volume":"513","author":"Harris","year":"2003","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"bpexae80cfbib10","doi-asserted-by":"publisher","first-page":"3501","DOI":"10.1088\/0031-9155\/59\/13\/3501","type":"journal-article","article-title":"Monte Carlo simulation of novel breast imaging modalities based on coherent x-ray scattering","volume":"59","author":"Ghammraoui","year":"2014","journal-title":"Phys. Med. Biol."},{"key":"bpexae80cfbib11","doi-asserted-by":"publisher","first-page":"6679","DOI":"10.1088\/0031-9155\/52\/22\/009","type":"journal-article","article-title":"Breast tissue classification using x-ray scatteringmeasurements and multivariate data analysis","volume":"52","author":"Ryan","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"bpexae80cfbib12","doi-asserted-by":"publisher","first-page":"3164","DOI":"10.1088\/0031-9155\/61\/8\/3164","type":"journal-article","article-title":"Maximum-likelihood estimation of scatter componentsalgorithm for x-ray coherent scatter computed tomography of the breast","volume":"61","author":"Ghammraoui","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"bpexae80cfbib13","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1088\/1361-6560\/aa5187","type":"journal-article","article-title":"Non-invasive classification of breast microcalcifications using x-ray coherent scatter computed tomography","volume":"62","author":"Ghammraoui","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"bpexae80cfbib14","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.3.1.013505","type":"journal-article","article-title":"Design and implementation of coded aperture coherent scatter spectral imaging of cancerous and healthy breast tissue samples","volume":"3","author":"Lakshmanan","year":"2016a","journal-title":"J. Med. Imaging"},{"key":"bpexae80cfbib15","doi-asserted-by":"publisher","DOI":"10.1117\/12.3006600","type":"conference-proceedings","article-title":"X-ray diffraction imaging of glioblastoma and ductal carcinoma in-situ proc. volume 12925","volume":"vol 129250I","author":"Greenberg","year":"2024"},{"key":"bpexae80cfbib16","article-title":"Wide field coherent scatter imaging for radiography using a divergent beam","author":"MacDonald","year":"2010","type":"other"},{"key":"bpexae80cfbib17","doi-asserted-by":"publisher","first-page":"2339","DOI":"10.1118\/1.2919768","type":"journal-article","article-title":"Comparison of slot scanning digital mammography system with full\u2010field digital mammography system","volume":"35","author":"Lai","year":"2008","journal-title":"Med. Phys."},{"key":"bpexae80cfbib18","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1148\/radiol.2015141303","type":"journal-article","article-title":"Digital breast tomosynthesis: state of the art","volume":"277","author":"Vedantham","year":"2015","journal-title":"Radiology"},{"key":"bpexae80cfbib19","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1002\/mp.12735","type":"journal-article","article-title":"Technical note: comparison of first- and second-generation photon-counting slit-scanning tomosynthesis systems","volume":"45","author":"Berggren","year":"2018","journal-title":"Med. Phys."},{"key":"bpexae80cfbib20","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1002\/mp.12684","type":"journal-article","article-title":"Characterization of photon-counting multislit breast tomosynthesis","volume":"45","author":"Berggren","year":"2018","journal-title":"Med. Phys."},{"key":"bpexae80cfbib21","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.3.3.033504","type":"journal-article","article-title":"Coherent scatter imaging Monte Carlo simulation","volume":"3","author":"Hassan","year":"2016","journal-title":"J. Med. Imaging"},{"key":"bpexae80cfbib22","doi-asserted-by":"publisher","DOI":"10.1117\/12.795383","type":"journal-article","volume":"7077","author":"Zhou","year":"2008"},{"key":"bpexae80cfbib23","doi-asserted-by":"publisher","DOI":"10.1117\/12.934916","type":"journal-article","volume":"8509","author":"Hassan","year":"2012"},{"key":"bpexae80cfbib24","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.3.3.030501","type":"journal-article","article-title":"Design for a coherent-scatter imaging system compatible with screening mammography","volume":"3","author":"Kern","year":"2016","journal-title":"J. Med. Imaging"},{"key":"bpexae80cfbib25","author":"Mahato","year":"2009","type":"other"},{"key":"bpexae80cfbib26","doi-asserted-by":"publisher","first-page":"4377","DOI":"10.1088\/0031-9155\/56\/14\/010","type":"journal-article","article-title":"X-ray coherent scattering form factors of tissues, water and plastics using energy dispersion","volume":"56","author":"King","year":"2011","journal-title":"Phys. Med. Biol."},{"key":"bpexae80cfbib27","doi-asserted-by":"publisher","DOI":"10.5281\/zenodo.20756922","type":"journal-article","author":"MacDonald","year":"2026","journal-title":"Embedded dataset for \u201cDevelopment of X-ray slot scan diffraction imaging for detection of carcinoma\u201d"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae80cf","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae80cf\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae80cf","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae80cf\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae80cf\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae80cf\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae80cf\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae80cf\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T07:01:24Z","timestamp":1783321284000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae80cf"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,6]]},"references-count":27,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,7,6]]},"published-print":{"date-parts":[[2026,8,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae80cf","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,6]]},"assertion":[{"value":"Development of x-ray slot scan diffraction imaging for detection of carcinoma","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2026-03-24","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-06-23","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-06","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}