{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T07:04:31Z","timestamp":1784012671080,"version":"3.55.0"},"reference-count":30,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T00:00:00Z","timestamp":1783987200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T00:00:00Z","timestamp":1783987200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100004410","name":"T\u00dcB\u0130TAK","doi-asserted-by":"crossref","award":["122E685"],"award-info":[{"award-number":["122E685"]}],"id":[{"id":"10.13039\/501100004410","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The objective of this study is to numerically compare the complete electrode model (CEM)\u2014widely regarded as the most general and physically realistic approach in electrical impedance tomography (EIT) forward problem solutions\u2014with the shunt electrode model, specifically in terms of transfer impedance (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mi>Z<\/mml:mi>\n                              <mml:mrow>\n                                <mml:mtext>t<\/mml:mtext>\n                              <\/mml:mrow>\n                            <\/mml:msub>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ). The analyses were performed on a two-dimensional heterogeneous thorax-like geometry. Sixteen surface electrodes were utilised, and adjacent and opposite current injection patterns were applied separately. Within the scope of CEM, the contact impedance (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mi>z<\/mml:mi>\n                              <mml:mrow>\n                                <mml:mtext>c<\/mml:mtext>\n                              <\/mml:mrow>\n                            <\/mml:msub>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ) was varied within the range of 10\n                    <jats:sup>\u22124<\/jats:sup>\n                    \u20131 \u03a9\u00b7m\n                    <jats:sup>2<\/jats:sup>\n                    while all other parameters were kept constant. The validity of the forward problem findings was tested through the addition of measurement noise (40\u201360 dB SNR) and image reconstruction studies. The results demonstrated that while\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mi>z<\/mml:mi>\n                              <mml:mrow>\n                                <mml:mtext>c<\/mml:mtext>\n                              <\/mml:mrow>\n                            <\/mml:msub>\n                          <\/mml:mrow>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    plays a decisive role at the injection electrodes where current is directly applied, both models produced practically identical results at the transfer impedance level under all examined conditions. Even under challenging noise conditions, the difference between the transfer impedances produced by the two models remained below 3%, and this equivalence was further proven at the inverse problem level by achieving a Pearson correlation of 0.989 for the adjacent pattern and 0.993 for the opposite pattern in the image reconstruction analyses. These findings quantitatively reveal that in wearable and real-time EIT systems utilising high-input-impedance measurement chains, the shunt electrode model provides a computationally more efficient alternative without causing any significant loss of accuracy during the image formation stage.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ae86fb","type":"journal-article","created":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T22:47:55Z","timestamp":1783464475000},"page":"045024","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["A numerical study on the equivalence of complete and shunt electrode models for transfer impedance in electrical impedance tomography"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8191-6210","authenticated-orcid":true,"given":"Oya K\u00f6ksal","family":"\u015eim\u015fek","sequence":"first","affiliation":[{"name":"Inonu University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2788-550X","authenticated-orcid":true,"given":"Orhan Erdem","family":"Haberal","sequence":"additional","affiliation":[{"name":"Baskent University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,7,14]]},"reference":[{"key":"bpexae86fbbib1","author":"Holder","year":"2004","edition":"(ed)","type":"book"},{"key":"bpexae86fbbib2","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2022.1011941","type":"journal-article","article-title":"Characteristics and topic trends on electrical impedance tomography hardware publications","volume":"13","author":"Qin","year":"2022","journal-title":"Front. Physiol."},{"key":"bpexae86fbbib3","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.726652","type":"journal-article","article-title":"The research progress of electrical impedance tomography for lung monitoring","volume":"9","author":"Shi","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"bpexae86fbbib4","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1137\/S0036144598333613","type":"journal-article","article-title":"Electrical impedance tomography","volume":"41","author":"Cheney","year":"1999","journal-title":"SIAM Rev."},{"key":"bpexae86fbbib5","first-page":"3","type":"book","article-title":"The reconstruction problem","author":"Lionheart","year":"2005"},{"key":"bpexae86fbbib6","doi-asserted-by":"publisher","first-page":"R99","DOI":"10.1088\/0266-5611\/18\/6\/201","type":"journal-article","article-title":"Electrical impedance tomography","volume":"18","author":"Borcea","year":"2002","journal-title":"Inverse Probl."},{"key":"bpexae86fbbib7","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1109\/TMI.2012.2200904","type":"journal-article","article-title":"Impact of model shape mismatch on reconstruction quality in electrical impedance tomography","volume":"31","author":"Grychtol","year":"2012","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexae86fbbib8","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1109\/10.35300","type":"journal-article","article-title":"Electrode models for electric current computed tomography","volume":"36","author":"Cheng","year":"1989","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexae86fbbib9","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1137\/0152060","type":"journal-article","article-title":"Existence and uniqueness for electrode models for electric current computed tomography","volume":"52","author":"Somersalo","year":"1992","journal-title":"SIAM J. Appl. Math."},{"key":"bpexae86fbbib10","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1051\/m2an\/2015049","type":"journal-article","article-title":"Electrode modelling: the effect of contact impedance","volume":"50","author":"Dard\u00e9","year":"2016","journal-title":"ESAIM Math. Model. Numer. Anal."},{"key":"bpexae86fbbib11","doi-asserted-by":"publisher","first-page":"1395","DOI":"10.1142\/S0218202511005362","type":"journal-article","article-title":"Justification of point electrode models in electrical impedance tomography","volume":"21","author":"Hanke","year":"2011","journal-title":"Math. Models Methods Appl. Sci."},{"key":"bpexae86fbbib12","doi-asserted-by":"publisher","first-page":"1919","DOI":"10.1080\/03605309608821249","type":"journal-article","article-title":"A singularly perturbed mixed boundary value problem","volume":"21","author":"Costabel","year":"1996","journal-title":"Commun. Partial Differ. Equ."},{"key":"bpexae86fbbib13","doi-asserted-by":"publisher","first-page":"4388","DOI":"10.1063\/1.531637","type":"journal-article","article-title":"Anomalous thresholds and edge singularities in electrical impedance tomography","volume":"37","author":"Ciulli","year":"1996","journal-title":"J. Math. Phys."},{"key":"bpexae86fbbib14","doi-asserted-by":"publisher","first-page":"2250","DOI":"10.1137\/17M1124292","type":"journal-article","article-title":"Smoothened complete electrode model","volume":"77","author":"Hyv\u00f6nen","year":"2017","journal-title":"SIAM J. Appl. Math."},{"key":"bpexae86fbbib15","doi-asserted-by":"publisher","first-page":"2494","DOI":"10.1109\/TBME.2017.2728323","type":"journal-article","article-title":"Electrical impedance tomography: tissue properties to image measures","volume":"64","author":"Adler","year":"2017","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexae86fbbib16","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1136\/thoraxjnl-2016-208357","type":"journal-article","article-title":"Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group","volume":"72","author":"Frerichs","year":"2017","journal-title":"Thorax"},{"key":"bpexae86fbbib17","doi-asserted-by":"publisher","DOI":"10.1038\/sdata.2018.112","type":"journal-article","article-title":"Multi-frequency electrical impedance tomography and neuroimaging data in stroke patients","volume":"5","author":"Goren","year":"2018","journal-title":"Sci. Data"},{"key":"bpexae86fbbib18","doi-asserted-by":"publisher","DOI":"10.1016\/j.nicl.2019.101909","type":"journal-article","article-title":"Comparison of electrical impedance tomography and intracranial pressure during dehydration treatment of cerebral edema","volume":"23","author":"Yang","year":"2019","journal-title":"Neuroimage Clin."},{"key":"bpexae86fbbib19","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1097\/00004669-199305000-00013","type":"journal-article","article-title":"Injected current patterns for electrical impedance imaging of the human thorax","volume":"18","author":"Ey\u00fcbo\u011flu","year":"1993","journal-title":"J. Clin. Eng."},{"key":"bpexae86fbbib20","doi-asserted-by":"publisher","first-page":"A99","DOI":"10.1088\/0967-3334\/16\/3A\/010","type":"journal-article","article-title":"Determination of optimum injected current patterns in electrical-impedance tomography","volume":"16","author":"Koksal","year":"1995","journal-title":"Physiol. Meas."},{"key":"bpexae86fbbib21","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1088\/0967-3334\/22\/1\/311","type":"journal-article","article-title":"Generalized optimal current patterns and electrical safety in EIT Physiol. Meas.","volume":"22","author":"Lionheart","year":"2001"},{"key":"bpexae86fbbib22","author":"Grimnes","year":"2008","edition":"2nd","type":"book"},{"key":"bpexae86fbbib23","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.1109\/10.784147","type":"journal-article","article-title":"Three-dimensional electrical impedance tomography based on the complete electrode model","volume":"46","author":"Vauhkonen","year":"2002","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"bpexae86fbbib24","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1088\/0967-3334\/32\/7\/S02","type":"journal-article","article-title":"The impact of electrode area, contact impedance and boundary shape on EIT images","volume":"32","author":"Boyle","year":"2011","journal-title":"Physiol. Meas."},{"key":"bpexae86fbbib25","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1088\/0967-3334\/27\/5\/S03","type":"journal-article","article-title":"Uses and abuses of EIDORS: an extensible software base for EIT","volume":"27","author":"Adler","year":"2006","journal-title":"Physiol. Meas."},{"key":"bpexae86fbbib26","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1088\/0031-9155\/41\/11\/001","type":"journal-article","article-title":"The dielectric properties of biological tissues: i. Literature survey","volume":"41","author":"Gabriel","year":"1996","journal-title":"Phys. Med. Biol."},{"key":"bpexae86fbbib27","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1088\/0967-3334\/27\/3\/007","type":"journal-article","article-title":"Optimum design of electrode structure and parameters in electrical impedance tomography","volume":"27","author":"Yan","year":"2006","journal-title":"Physiol. Meas."},{"key":"bpexae86fbbib28","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/ad2215","type":"journal-article","article-title":"Evaluation of adjacent and opposite current injection patterns for a wearable chest electrical impedance tomography system","volume":"45","author":"Yang","year":"2024","journal-title":"Physiol. Meas."},{"key":"bpexae86fbbib29","doi-asserted-by":"publisher","first-page":"7774","DOI":"10.3390\/s23187774","type":"journal-article","article-title":"Image reconstruction using supervised learning in wearable electrical impedance tomography of the thorax","volume":"23","author":"Ivanenko","year":"2023","journal-title":"Sensors"},{"key":"bpexae86fbbib30","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.3390\/s23031182","type":"journal-article","article-title":"Electrical impedance tomography: from the traditional design to the novel frontier of wearables","volume":"23","author":"Pennati","year":"2023","journal-title":"Sensors"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae86fb","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae86fb\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae86fb","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae86fb\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae86fb\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae86fb\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae86fb\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae86fb\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T06:15:50Z","timestamp":1784009750000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae86fb"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,14]]},"references-count":30,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,7,14]]},"published-print":{"date-parts":[[2026,8,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae86fb","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,14]]},"assertion":[{"value":"A numerical study on the equivalence of complete and shunt electrode models for transfer impedance in electrical impedance tomography","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2026-03-26","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-07","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-14","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}