{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T15:18:10Z","timestamp":1786115890959,"version":"build-2736575974"},"reference-count":36,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T00:00:00Z","timestamp":1785974400000},"content-version":"vor","delay-in-days":5,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T00:00:00Z","timestamp":1785974400000},"content-version":"tdm","delay-in-days":5,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    This study investigated a water equivalent diameter (WED)-based tube voltage selection protocol for optimizing radiation dose and image quality in pediatric chest CT. A total of 100 pediatric patients were enrolled and retrospectively analyzed. They were divided into two groups based on the tube voltage used during chest CT: 100 kV and 120 kV. We set the region of interest at the tracheal bifurcation in slice images of the lung, aorta, mediastinum, and humerus muscles, and calculated each organ\u2019s signal-to-noise ratio (SNR). We also calculated the central size-specific dose estimate (SSDE\n                    <jats:sub>center<\/jats:sub>\n                    ), as well as the WED at the scan center and tracheal bifurcation. To normalize the CT scanner output, the ratio of SSDE to volume CT dose index (CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    ) and the ratio of SNR to CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    of each target organ were calculated. We then evaluated the radiation dose and image quality of the two tube voltage protocols across different WEDs. Finally, the relationship between these ratios and WED was analyzed using fitting methods, and the advantageous WED ranges for the two protocols were determined based on curve intersections. The results demonstrated that SSDE\n                    <jats:sub>center<\/jats:sub>\n                    (coefficient of determination (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sup>2<\/jats:sup>\n                    ) = 0.67) and SNR (\n                    <jats:italic>R<\/jats:italic>\n                    <jats:sup>2<\/jats:sup>\n                    &gt; 0.60) were correlated with WED. Under identical radiation output, the 100 kV protocol achieved a lower radiation dose for patients with WED &lt; 22 cm, whereas the 120 kV demonstrated better dose optimization for those with WED &gt; 22 cm. For most organs except the aorta, SNR was higher at 100 kV when WED &lt; 24 cm, with 120 kV proving superior above this threshold. The aorta consistently demonstrated better SNR at 120 kV regardless of WED. Based on these findings, we recommend 100 kV for patients with WED &lt; 22 cm and 120 kV for those exceeding this threshold, guiding the optimization of pediatric chest CT protocols.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ae90b1","type":"journal-article","created":{"date-parts":[[2026,7,27]],"date-time":"2026-07-27T22:47:46Z","timestamp":1785192466000},"page":"045056","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Size-based optimization of pediatric CT protocols: balancing radiation dose and image quality"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-4523-5710","authenticated-orcid":true,"given":"Qingting","family":"Sun","sequence":"first","affiliation":[{"name":"School of Medical Imaging, Bengbu Medical University, Anhui Province"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-8024-8528","authenticated-orcid":false,"given":"Yihan","family":"Fan","sequence":"additional","affiliation":[{"name":"School of Medical Imaging, Bengbu Medical University, Anhui Province"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-9018-8660","authenticated-orcid":false,"given":"Pengfei","family":"Zhu","sequence":"additional","affiliation":[{"name":"School of Medical Imaging, Bengbu Medical University, Anhui Province"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-7554-1210","authenticated-orcid":true,"given":"Jing","family":"Wang","sequence":"additional","affiliation":[{"name":"The First Affiliated Hospital of Bengbu Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9814-0332","authenticated-orcid":true,"given":"Yankui","family":"Chang","sequence":"additional","affiliation":[{"name":"School of Medical Imaging, Bengbu Medical University, Anhui Province"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4901-5994","authenticated-orcid":true,"given":"Baohui","family":"Liang","sequence":"additional","affiliation":[{"name":"School of Medical Imaging, Bengbu Medical University, Anhui Province"},{"name":"Anhui Key Laboratory of Digital Medicine and Intelligent Health, Bengbu Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,8,6]]},"reference":[{"key":"bpexae90b1bib1","doi-asserted-by":"publisher","first-page":"e740","DOI":"10.1002\/mp.13058","type":"journal-article","article-title":"Recent advances on the development of phantoms using 3D printing for imaging with CT, MRI, PET, SPECT, and ultrasound","volume":"45","author":"Filippou","year":"2018","journal-title":"Med. Phys."},{"key":"bpexae90b1bib2","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1056\/NEJMra072149","type":"journal-article","article-title":"Computed tomography\u2013an increasing source of radiation exposure","volume":"357","author":"Brenner","year":"2007","journal-title":"New Engl. J. Med."},{"key":"bpexae90b1bib3","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/j.ejrad.2017.10.023","type":"journal-article","article-title":"Patterns of CT use in Japan, 2014: a nationwide cross-sectional study","volume":"97","author":"Koyama","year":"2017","journal-title":"Eur. J. Radiol."},{"key":"bpexae90b1bib4","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1007\/s00247-002-0671-1","type":"journal-article","article-title":"Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative","volume":"32","author":"Brenner","year":"2002","journal-title":"Pediatr. Radiol."},{"key":"bpexae90b1bib5","doi-asserted-by":"publisher","first-page":"302","DOI":"10.13491\/j.cnki.issn.1004-714x.2017.03.016","type":"journal-article","article-title":"The study and prediction of the total number of radio-diagnosis and radiotherapy examination in hospitals","volume":"26","author":"Su","year":"2017","journal-title":"Chin. J. Radiol. Health"},{"key":"bpexae90b1bib6","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.ejmp.2017.12.013","type":"journal-article","article-title":"Patient-specific organ and effective dose estimates in pediatric oncology computed tomography","volume":"45","author":"Gao","year":"2018","journal-title":"Phys. Med."},{"key":"bpexae90b1bib7","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2019.04.011","type":"journal-article","article-title":"Survey of paediatric imaging exposure from computed tomography examinations.","volume":"167","author":"Alkhorayef","year":"2020","journal-title":"Radiat. Phys. Chem."},{"key":"bpexae90b1bib8","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1007\/s11547-020-01179-x","type":"journal-article","article-title":"Proposal of a low-dose, long-pitch, dual-source chest CT protocol on third-generation dual-source CT using a tin filter for spectral shaping at 100 kVp for CoronaVirus Disease 2019 (COVID-19) patients: a feasibility study","volume":"125","author":"Agostini","year":"2020","journal-title":"Radiol. Med."},{"key":"bpexae90b1bib9","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1007\/s00247-022-05526-0","type":"journal-article","article-title":"Paediatric CT made easy","volume":"53","author":"Nagy","year":"2023","journal-title":"Pediatr. Radiol."},{"key":"bpexae90b1bib10","doi-asserted-by":"publisher","first-page":"f2360","DOI":"10.1136\/bmj.f2360","type":"journal-article","article-title":"Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians","volume":"346","author":"Mathews","year":"2013","journal-title":"BMJ"},{"key":"bpexae90b1bib11","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1148\/radiol.14132903","type":"journal-article","article-title":"Estimates of effective dose for CT scans of the lower extremities","volume":"273","author":"Saltybaeva","year":"2014","journal-title":"Radiology"},{"key":"bpexae90b1bib12","article-title":"Report No. 204\u2014Size-Specific dose estimates (SSDE) in pediatric and adult body CTexaminations","author":"Boone","year":"2011","type":"report"},{"key":"bpexae90b1bib13","article-title":"Report No. 220\u2014Use of water equivalent diameter for calculating patient size and size-specific dose estimates (SSDE) in CT","author":"McCollough","year":"2014","type":"report"},{"key":"bpexae90b1bib14","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1148\/radiol.2483071964","type":"journal-article","article-title":"Converting dose-length product to effective dose at CT","volume":"248","author":"Huda","year":"2008","journal-title":"Radiology"},{"key":"bpexae90b1bib15","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1002\/mp.17472","type":"journal-article","article-title":"Monte Carlo dose calculation for photon and electron radiotherapy on dynamically deforming anatomy","volume":"52","author":"Zobrist","year":"2025","journal-title":"Med. Phys."},{"key":"bpexae90b1bib16","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1007\/s10554-015-0782-z","type":"journal-article","article-title":"Validity of the size-specific dose estimate in adults undergoingcoronary CT angiography: comparison with the volumeCT dose index","volume":"31","author":"Kidoh","year":"2015","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"bpexae90b1bib17","doi-asserted-by":"publisher","first-page":"0969","DOI":"10.1016\/j.radphyschem.2021.109685","type":"journal-article","article-title":"Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination","volume":"188","author":"Karim","year":"2021","journal-title":"Radiat. Phys. Chem."},{"key":"bpexae90b1bib18","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.2214\/AJR.09.3726","type":"journal-article","article-title":"Evaluation of a radiation dose reduction strategy for pediatric chest CT","volume":"194","author":"Kim","year":"2010","journal-title":"AJR Am. J. Roentgenol."},{"key":"bpexae90b1bib19","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.85284","type":"journal-article","article-title":"Pediatric local diagnostic reference levels for CT examinations: a study based on the European guidelines on diagnostic reference levels for pediatric imaging","volume":"17","author":"Syrgiamiotis","year":"2025","journal-title":"Cureus"},{"key":"bpexae90b1bib20","doi-asserted-by":"publisher","article-title":"Variation in paediatric CT protocols\u2014A survey of Irish practices [Scientific Exhibit]","author":"Gavin","DOI":"10.26044\/ecr2025\/C-14800","type":"conference-proceedings"},{"key":"bpexae90b1bib21","doi-asserted-by":"publisher","first-page":"1598","DOI":"10.1007\/s00330-014-3559-1","type":"journal-article","article-title":"Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utility","volume":"25","author":"Braun","year":"2015","journal-title":"Eur. Radiol."},{"key":"bpexae90b1bib22","doi-asserted-by":"publisher","first-page":"2008","DOI":"10.1093\/rpd\/ncae212","type":"journal-article","article-title":"Radiation dose assessment of pediatric computed tomography of the chest: the need to consider patient size","volume":"200","author":"D\u00f6wich","year":"2024","journal-title":"Radiat. Prot. Dosim."},{"key":"bpexae90b1bib23","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1148\/radiol.2333031150","type":"journal-article","article-title":"Techniques and applications of automatic tube current modulation for CT","volume":"233","author":"Kalra","year":"2004","journal-title":"Radiology"},{"key":"bpexae90b1bib24","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1002\/acm2.12857","type":"journal-article","article-title":"Patient size matters: effect of tube current modulation on size-specific dose estimates (SSDE) and image quality in low-dose lung cancer screening CT","volume":"21","author":"Barreto","year":"2020","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae90b1bib25","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1093\/jrr\/rry022","type":"journal-article","article-title":"Consideration of the usefulness of a size-specific dose estimate in pediatric CT examination","volume":"59","author":"Tsujiguchi","year":"2018","journal-title":"J. Radiat. Res."},{"key":"bpexae90b1bib26","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.1148\/rg.2018180041","type":"journal-article","article-title":"Radiation dose reduction at pediatric CT: use of low tube voltage and iterative reconstruction","volume":"38","author":"Nagayama","year":"2018","journal-title":"Radiographics"},{"key":"bpexae90b1bib27","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1002\/acm2.12340","type":"journal-article","article-title":"Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size","volume":"19","author":"Kawashima","year":"2018","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae90b1bib28","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ejmp.2011.11.004","type":"journal-article","article-title":"Automatic exposure control at MDCT based on the contrast-to-noise ratio: theoretical background and phantom study","volume":"29","author":"Funama","year":"2013","journal-title":"Phys. Med."},{"key":"bpexae90b1bib29","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1120\/jacmp.v17i1.5756","type":"journal-article","article-title":"Size-based protocol optimization using automatic tube current modulation and automatic kV selection in computed tomography","volume":"17","author":"MacDougall","year":"2016","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae90b1bib30","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmir.2026.102207","type":"journal-article","article-title":"A scoping review of radiation dose and image quality in paediatric CT: towards safe imaging protocols and diagnostic reference levels in Jordan","volume":"57","author":"Hameedat","year":"2026","journal-title":"J. Med. Imaging Radiat. Sci."},{"key":"bpexae90b1bib31","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1259\/0007-1285-60-717-907","type":"journal-article","article-title":"Average soft-tissue and bone models for use in radiation dosimetry","volume":"60","author":"White","year":"1987","journal-title":"Br. J. Radiol."},{"key":"bpexae90b1bib32","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1177\/02841851211001539","type":"journal-article","article-title":"Effects of tube voltage and iodine contrast medium on radiation dose of whole-body CT","volume":"63","author":"Yoshida","year":"2022","journal-title":"Acta Radiol."},{"key":"bpexae90b1bib33","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1148\/radiol.2303021726","type":"journal-article","article-title":"Strategies for CT radiation dose optimization","volume":"230","author":"Kalra","year":"2004","journal-title":"Radiology"},{"key":"bpexae90b1bib34","doi-asserted-by":"publisher","first-page":"1997","DOI":"10.1118\/1.597899","type":"journal-article","article-title":"Comparison of x-ray cross sections for diagnostic and therapeutic medical physics","volume":"23","author":"Boone","year":"1986","journal-title":"Med. Phys."},{"key":"bpexae90b1bib35","doi-asserted-by":"publisher","first-page":"1048","DOI":"10.1118\/1.4811156","type":"journal-article","article-title":"The essential physics of medical imaging, third edition","volume":"40","author":"Mahesh","year":"2013","journal-title":"Med. Phys."},{"key":"bpexae90b1bib36","doi-asserted-by":"publisher","first-page":"2386","DOI":"10.1002\/mp.16990","type":"journal-article","article-title":"Spectral information content of Compton scattering events in silicon photon counting detectors","volume":"51","author":"Hsieh","year":"2024","journal-title":"Med. Phys."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae90b1","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae90b1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae90b1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae90b1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae90b1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae90b1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae90b1\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae90b1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T06:19:35Z","timestamp":1785997175000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae90b1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,1]]},"references-count":36,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,8,6]]},"published-print":{"date-parts":[[2026,8,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae90b1","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,1]]},"assertion":[{"value":"Size-based optimization of pediatric CT protocols: balancing radiation dose and image quality","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-03-03","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-27","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-08-06","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}