{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:54:42Z","timestamp":1786121682035,"version":"build-2736575974"},"reference-count":34,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T00:00:00Z","timestamp":1786060800000},"content-version":"vor","delay-in-days":6,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T00:00:00Z","timestamp":1786060800000},"content-version":"tdm","delay-in-days":6,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Background.<\/jats:italic>\n                    Established methods are available for measuring the noise power spectrum (NPS) in computed tomography (CT) by using uniform phantoms. However, in clinical practice, direct estimation of this metric from patient images is desirable for continuous image quality monitoring and protocol optimization.\n                    <jats:italic>Methodology.<\/jats:italic>\n                    An automated workflow was developed through the integration of liver segmentation with TotalSegmentator, optimized selection of square patches in potentially homogeneous regions using a greedy algorithm, and NPS computation employing the PyLinac library. CT images from five patients and one homogeneous phantom were analyzed using two reconstruction kernels (lung and standard). Validation was performed using Kullback\u2013Leibler divergence (\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>D<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mrow>\n                                <mml:mi>KL<\/mml:mi>\n                              <\/mml:mrow>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    ) to compare the NPS distributions obtained from patients and phantoms under equivalent acquisition conditions.\n                    <jats:italic>Results.<\/jats:italic>\n                    NPS estimation from abdominal images was feasible. In nearly all paired comparisons (phantom versus patient under identical acquisition and reconstruction conditions),\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:msub>\n                            <mml:mi>D<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mrow>\n                                <mml:mi>KL<\/mml:mi>\n                              <\/mml:mrow>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    values between normalized NPS distributions were below\n                    <jats:inline-formula>\n                      <jats:tex-math>\n                        \n                      <\/jats:tex-math>\n                      <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\" overflow=\"scroll\">\n                        <mml:mrow>\n                          <mml:mn>0.05<\/mml:mn>\n                        <\/mml:mrow>\n                      <\/mml:math>\n                    <\/jats:inline-formula>\n                    , indicating strong agreement in the shape of the spatial noise distribution between the homogeneous phantom and clinical studies.\n                    <jats:italic>Conclusion.<\/jats:italic>\n                    An automated workflow for NPS estimation in the hepatic parenchyma is presented. The similarity between the characteristic NPS profile obtained from the patient images and that derived from a homogeneous phantom acquired under equivalent conditions was subsequently validated. These preliminary results support the potential integration of this metric as a complementary quantitative tool for CT quality control programs, directly on patient images.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ae9311","type":"journal-article","created":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T22:47:48Z","timestamp":1785538068000},"page":"045059","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Automated patient-derived noise power spectrum estimation in abdominal CT: a preliminary validation"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-3766-9296","authenticated-orcid":true,"given":"Mary Karla","family":"P\u00e9rez S\u00e1nchez","sequence":"first","affiliation":[{"name":"Technology and Environment"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1020-8775","authenticated-orcid":false,"given":"Adlin","family":"L\u00f3pez D\u00edaz","sequence":"additional","affiliation":[{"name":"Universidad de La Frontera"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6011-1947","authenticated-orcid":false,"given":"Yusely","family":"Ruiz Gonz\u00e1lez","sequence":"additional","affiliation":[{"name":"\u2018Marta Abreu\u2019 Central University of Las Villas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5808-4102","authenticated-orcid":true,"given":"Mauro","family":"Nam\u00edas","sequence":"additional","affiliation":[{"name":"Nuclear Diagnostic Center Foundation"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,8,7]]},"reference":[{"key":"bpexae9311bib1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00330-025-11911-8","type":"journal-article","article-title":"Balancing patients\u2019 benefits and risks in computed tomography: a European society of radiology \u2018EuroSafe Imaging\u2019viewpoint","volume":"36","author":"European Society of Radiology (ESR)","year":"2025","journal-title":"Eur. Radiol."},{"key":"bpexae9311bib2","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1007\/s40134-022-00399-5","type":"journal-article","article-title":"A review of deep learning ct reconstruction: concepts, limitations and promise in clinical practice","volume":"10","author":"Szczykutowicz","year":"2022","journal-title":"Curr. Radiol. Rep."},{"key":"bpexae9311bib3","doi-asserted-by":"publisher","DOI":"10.1118\/1.4800795","type":"journal-article","article-title":"A simple approach to measure computed tomography (CT) modulation transfer function (MTF) and noise-power spectrum (NPS) using the American college of radiology (ACR) accreditation phantom","volume":"40","author":"Friedman","year":"2013","journal-title":"Med. Phys."},{"key":"bpexae9311bib4","doi-asserted-by":"publisher","first-page":"1267","DOI":"10.1007\/s00330-021-08248-3","type":"journal-article","article-title":"Comparison of low-contrast detectability between uniform and anatomically realistic phantoms\u2014influences on ct image quality assessment","volume":"32","author":"Conzelmann","year":"2022","journal-title":"Eur. Radiol."},{"key":"bpexae9311bib5","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/abb2f8","type":"journal-article","article-title":"Development of a computational phantom for validation of automated noise measurement in ct images","volume":"6","author":"Anam","year":"2020","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexae9311bib6","doi-asserted-by":"publisher","first-page":"W93","DOI":"10.2214\/AJR.14.13613","type":"journal-article","article-title":"Automated technique to measure noise in clinical ct examinations","volume":"205","author":"Christianson","year":"2015","journal-title":"Am. J. Roentgenol."},{"key":"bpexae9311bib7","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.8.5.052113","type":"journal-article","article-title":"Development and validation of an automated methodology to assess perceptual in vivo noise texture in liver ct","volume":"8","author":"Smith","year":"2021","journal-title":"J. Med. Imaging"},{"key":"bpexae9311bib8","doi-asserted-by":"publisher","first-page":"09NT01","DOI":"10.1088\/1361-6560\/ad3883","type":"journal-article","article-title":"An automated technique for global noise level measurement in CT image with a conjunction of image gradient","volume":"69","author":"Kuo","year":"2024","journal-title":"Phys. Med. Biol."},{"key":"bpexae9311bib9","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.11.3.035501","type":"journal-article","article-title":"Perceptual thresholds for differences in ct noise texture","volume":"11","author":"Oostveen","year":"2024","journal-title":"J. Med. Imaging"},{"key":"bpexae9311bib10","doi-asserted-by":"publisher","DOI":"10.1148\/ryai.230024","type":"journal-article","article-title":"Totalsegmentator: robust segmentation of 104 anatomic structures in ct images","volume":"5","author":"Wasserthal","year":"2023","journal-title":"Radiol. Artif. Intell."},{"key":"bpexae9311bib11","doi-asserted-by":"publisher","first-page":"1617","DOI":"10.1007\/s10278-024-01265-w","type":"journal-article","article-title":"Intra individual reproducibility of automated abdominal organ segmentation performance of totalsegmentator compared to human readers and an independent nnu net model","volume":"38","author":"Abel","year":"2025","journal-title":"J. Imaging Inf. Med."},{"key":"bpexae9311bib12","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2026.112674","type":"journal-article","article-title":"Performance analysis of liver segmentation using nn-UNet totalsegmentator: focus on atypical livers, pathologies and variants","volume":"196","author":"Klei\u00df","year":"2026","journal-title":"Eur. J. Radiol."},{"key":"bpexae9311bib13","doi-asserted-by":"publisher","first-page":"6531","DOI":"10.1109\/TPAMI.2025.3560423","type":"journal-article","article-title":"Hadamard product in deep learning: introduction, advances and challenges","volume":"47","author":"Chrysos","year":"2025","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"bpexae9311bib14","author":"Cormen","year":"2022","type":"book"},{"key":"bpexae9311bib15","doi-asserted-by":"publisher","DOI":"10.1118\/1.4893497","type":"journal-article","article-title":"Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE","volume":"41","author":"Solomon","year":"2014","journal-title":"Med. Phys."},{"key":"bpexae9311bib16","doi-asserted-by":"publisher","first-page":"6001","DOI":"10.21105\/joss.06001","type":"journal-article","article-title":"Pylinac: image analysis for routine quality assurance in radiotherapy","volume":"8","author":"Kerns","year":"2023","journal-title":"J. Open Source Softw."},{"key":"bpexae9311bib17","article-title":"Radiation dose and image-quality assessment in computed tomography","author":"International Commission on Radiation Units and Measurements","year":"2012","type":"report"},{"key":"bpexae9311bib17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/jicru\/ndt007","type":"journal-article","volume":"12","author":"International Commission on Radiation Units and Measurements"},{"key":"bpexae9311bib18","doi-asserted-by":"publisher","first-page":"5682","DOI":"10.1002\/mp.16373","type":"journal-article","article-title":"3d-printed iodine-ink ct phantom for radiomics feature extraction-advantages and challenges","volume":"50","author":"Bach","year":"2023","journal-title":"Med. Phys."},{"key":"bpexae9311bib19","doi-asserted-by":"publisher","DOI":"10.1177\/20584601221109919","type":"journal-article","article-title":"Iterative reconstruction with multifrequency signal recognition technology to improve low-contrast detectability: a phantom study","volume":"11","author":"Funama","year":"2022","journal-title":"Acta. Radiol. Open"},{"key":"bpexae9311bib20","article-title":"Performance of three model-based iterative reconstruction algorithms using a CT task-based image quality metric","author":"Muti","year":"2023","type":"preprint"},{"key":"bpexae9311bib21","first-page":"74461","type":"journal-article","article-title":"Decoupled Kullback-Leibler divergence loss","volume":"37","author":"Cui","year":"2024","journal-title":"Adv. Neural Inf. Process. Syst."},{"key":"bpexae9311bib22","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1080\/00031305.2018.1537891","type":"journal-article","article-title":"Before p <0.05 to beyond p <0.05: using history to contextualize p-values and significance testing","volume":"73","author":"Kennedy-Shaffer","year":"2019","journal-title":"Am. Stat."},{"key":"bpexae9311bib23","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1117\/12.2294579","type":"journal-article","article-title":"The effects of tube current modulation on the noise power spectra of patients with different size: consequences for quality monitoring","volume":"10573","author":"Fulco","year":"2018","journal-title":"Proc. SPIE"},{"key":"bpexae9311bib24","doi-asserted-by":"publisher","DOI":"10.1118\/1.4884038","type":"journal-article","article-title":"Statistical model based iterative reconstruction (MBIR) in clinical ct systems. part ii. Experimental assessment of spatial resolution performance","volume":"41","author":"Li","year":"2014","journal-title":"Med. Phys."},{"key":"bpexae9311bib25","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1002\/acm2.12253","type":"journal-article","article-title":"New adaptive statistical iterative reconstruction ASiR-V: assessment of noise performance in comparison to ASiR","volume":"19","author":"De Marco","year":"2018","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae9311bib26","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1118\/1.4938588","type":"journal-article","article-title":"Accurate assessment and prediction of noise in clinical CT images","volume":"43","author":"Tian","year":"2016","journal-title":"Med. Phys."},{"key":"bpexae9311bib27","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1117\/12.2293123","type":"journal-article","article-title":"Virtual clinical trial in action: textured XCAT phantoms and scanner-specific CT simulator to characterize noise across CT reconstruction algorithms","volume":"10573","author":"Ehsan Abadi","year":"2018","journal-title":"Proc. SPIE"},{"key":"bpexae9311bib28","doi-asserted-by":"publisher","first-page":"4777","DOI":"10.1088\/1361-6560\/aa6a97","type":"journal-article","article-title":"Task-driven optimization of CT tube current modulation and regularization in model-based iterative reconstruction","volume":"62","author":"Gang","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"bpexae9311bib29","doi-asserted-by":"publisher","first-page":"766","DOI":"10.21037\/qims-21-245","type":"journal-article","article-title":"A phantom study comparing low-dose CT physical image quality from five different ct scanners","volume":"12","author":"Yali","year":"2022","journal-title":"Quant. Imaging Med. Surg."},{"key":"bpexae9311bib30","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1093\/rpd\/ncaa034","type":"journal-article","article-title":"Characterization of two ct systems using a channelized hotelling observer and NPS metric","volume":"189","author":"Ortenzia","year":"2020","journal-title":"Radiat. Prot. Dosim."},{"key":"bpexae9311bib31","doi-asserted-by":"publisher","first-page":"4229","DOI":"10.1002\/mp.15015","type":"journal-article","article-title":"Impact of iterative reconstruction algorithms on the applicability of Fourier-based detectability index for x-ray CT imaging","volume":"48","author":"Pouget","year":"2021","journal-title":"Med. Phys."},{"key":"bpexae9311bib32","doi-asserted-by":"publisher","first-page":"3961","DOI":"10.1002\/mp.14319","type":"journal-article","article-title":"Noise and spatial resolution properties of a commercially available deep learning-based ct reconstruction algorithm","volume":"47","author":"Solomon","year":"2020","journal-title":"Med. Phys."},{"key":"bpexae9311bib33","doi-asserted-by":"publisher","first-page":"817","DOI":"10.3390\/diagnostics16050817","type":"journal-article","article-title":"Comparison of manual, semi-automatic and automatic CT-based methods for liver volume segmentation","volume":"16","author":"Dogan","year":"2026","journal-title":"Diagnostics"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9311","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9311\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9311","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9311\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9311\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9311\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9311\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9311\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T06:20:13Z","timestamp":1786083613000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9311"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,1]]},"references-count":34,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,8,7]]},"published-print":{"date-parts":[[2026,8,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae9311","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,1]]},"assertion":[{"value":"Automated patient-derived noise power spectrum estimation in abdominal CT: a preliminary validation","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-06","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-07-31","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-08-07","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}