{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T06:17:57Z","timestamp":1788329877727,"version":"build-2803163510"},"reference-count":21,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T00:00:00Z","timestamp":1788307200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T00:00:00Z","timestamp":1788307200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Faculty Sciences and Mathematics, Diponegoro University","award":["35.M\/UN7.F8\/PP\/II\/2026"],"award-info":[{"award-number":["35.M\/UN7.F8\/PP\/II\/2026"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,10,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Purpose.<\/jats:italic>\n                    To develop an automated method for measuring spatial resolution using the bar pattern objects in Catphan 500, 503, 504, 600, and 604 phantoms.\n                    <jats:italic>Method.<\/jats:italic>\n                    After identifying the phantom\u2019s center coordinates and anchor, we used template matching to estimate the position of each bar pattern object. Subsequently, a circular mask was used to segment the objects locally, yielding the accurate center point of each object. A region of interest (ROI) was then drawn on each object, taking into account its position and angle relative to the phantom center. By plotting the modulation transfer function (MTF) derived from the variance method against the spatial frequency of each object, an MTF curve was constructed. To test the robustness of the proposed method, we evaluated the automated algorithm across phantom model variations, geometric modifications, and reconstruction filters. The measurement results were compared with the visual assessments of 10 human observers.\n                    <jats:italic>Results.<\/jats:italic>\n                    The proposed method successfully identified targets and placed ROIs with 100% accuracy across all phantom models and extreme geometric variations. Statistical validation revealed that the automated 10% MTF limits possess a strong and highly significant positive correlation with the visual detection thresholds of human observers. This robust agreement was consistently maintained across all evaluated phantom models (\n                    <jats:italic>r<\/jats:italic>\n                    = 0.96,\n                    <jats:italic>p<\/jats:italic>\n                    = 0.01) as well as the varying reconstruction filters (\n                    <jats:italic>r<\/jats:italic>\n                    = 0.97,\n                    <jats:italic>p<\/jats:italic>\n                    = 0.03). Under geometric modifications (rotations and flips), the method exhibited excellent measurement stability with a coefficient of variation (CoV) of 4.05%.\n                    <jats:italic>Conclusion.<\/jats:italic>\n                    The proposed automated method accurately measures the MTF of bar pattern objects across Catphan models 500, 503, 504, 600, and 604 with 100% target identification accuracy. It demonstrates geometric robustness against image misalignment, shows high sensitivity in quantifying minor resolution degradation, and correlates strongly with human visual thresholds (\n                    <jats:italic>r<\/jats:italic>\n                    \u2a7e 0.96).\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/ae9e3a","type":"journal-article","created":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T22:48:22Z","timestamp":1787698102000},"page":"055001","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Development and validation of an automated MTF measurement method for five types of Catphan phantoms using bar pattern objects"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0156-6797","authenticated-orcid":true,"given":"Choirul","family":"Anam","sequence":"first","affiliation":[{"name":"Diponegoro University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4218-6259","authenticated-orcid":true,"given":"Ariij","family":"Naufal","sequence":"additional","affiliation":[{"name":"Diponegoro University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Evi","family":"Setiawati","sequence":"additional","affiliation":[{"name":"Diponegoro University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3846-5116","authenticated-orcid":true,"given":"Noor Diyana","family":"Osman","sequence":"additional","affiliation":[{"name":"Universiti Sains Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geoff","family":"Dougherty","sequence":"additional","affiliation":[{"name":"California State University Channel Islands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,9,2]]},"reference":[{"key":"bpexae9e3abib1","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1120\/jacmp.v16i4.5469","type":"journal-article","article-title":"Quality control of CT systems by automated monitoring of key performance indicators: a two-year study","volume":"16","author":"Nowik","year":"2015","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae9e3abib2","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1186\/s13244-025-02037-y","type":"journal-article","article-title":"Objective assessment of diagnostic image quality in CT scans: what radiologists and researchers need to know","volume":"16","author":"Hoeijmakers","year":"2025","journal-title":"Insights Imaging"},{"key":"bpexae9e3abib3","doi-asserted-by":"publisher","first-page":"4417","DOI":"10.1120\/jacmp.v14i6.4417","type":"journal-article","article-title":"Scanner and kVp dependence of measured CT numbers in the ACR CT phantom","volume":"14","author":"Cropp","year":"2013","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae9e3abib4","doi-asserted-by":"publisher","first-page":"264","DOI":"10.3390\/jimaging9120264","type":"journal-article","article-title":"The dose optimization and evaluation of image quality in the adult brain protocols of multi-slice computed tomography: a phantom study","volume":"9","author":"Prabsattroo","year":"2023","journal-title":"J. Imaging"},{"key":"bpexae9e3abib5","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1148\/radiol.2018181156","type":"journal-article","article-title":"Improving spatial resolution at CT: development, benefits, and pitfalls","volume":"289","author":"Wang","year":"2018","journal-title":"Radiology"},{"key":"bpexae9e3abib6","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1016\/j.jcct.2022.02.003","type":"journal-article","article-title":"CT imaging with ultra-high-resolution: opportunities for cardiovascular imaging in clinical practice","volume":"16","author":"Schuijf","year":"2022","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"bpexae9e3abib7","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.70078","type":"journal-article","article-title":"A method for measuring spatial resolution based on clinical chest CT sequence images","volume":"26","author":"Liu","year":"2025","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae9e3abib8","doi-asserted-by":"publisher","first-page":"4115","DOI":"10.1118\/1.4725171","type":"journal-article","article-title":"Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms","volume":"39","author":"Richard","year":"2012","journal-title":"Med. Phys."},{"key":"bpexae9e3abib9","doi-asserted-by":"publisher","first-page":"3637","DOI":"10.1118\/1.4734770","type":"journal-article","article-title":"SU-E-I-54: evaluation of high contrast resolution for model based iterative reconstruction of sinus examinations","volume":"39","author":"Paden","year":"2012","journal-title":"Med. Phys."},{"key":"bpexae9e3abib10","doi-asserted-by":"publisher","DOI":"10.1117\/12.2082049","type":"journal-article","article-title":"Lesion insertion in projection domain for computed tomography image quality assessment","volume":"9412","author":"Chen","year":"2015","journal-title":"Proc. SPIE"},{"key":"bpexae9e3abib11","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1097\/RCT.0000000000000472","type":"journal-article","article-title":"Evaluation of abdominal computed tomography image quality using a new version of vendor-specific model-based iterative reconstruction","volume":"41","author":"Jensen","year":"2017","journal-title":"J. Comput. Assist. Tomogr."},{"key":"bpexae9e3abib12","doi-asserted-by":"publisher","first-page":"766","DOI":"10.21037\/qims-21-245","type":"journal-article","article-title":"A phantom study comparing low-dose CT physical image quality from five different CT scanners","volume":"12","author":"Li","year":"2022","journal-title":"Quant. Imaging Med. Surg."},{"key":"bpexae9e3abib13","doi-asserted-by":"publisher","first-page":"179","DOI":"10.2478\/pjmpe-2019-0024","type":"journal-article","article-title":"Automated MTF measurement in CT images with a simple wire phantom","volume":"25","author":"Anam","year":"2019","journal-title":"Polish J. Med. Phys. Eng."},{"key":"bpexae9e3abib14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2024.104876","type":"journal-article","article-title":"Statistical phase alignment of edge spread function for modulation transfer func tion measurement on computed tomography images","volume":"129","author":"Anam","year":"2025","journal-title":"Phys. Med."},{"key":"bpexae9e3abib15","doi-asserted-by":"publisher","first-page":"277","DOI":"10.3390\/jimaging11080277","type":"journal-article","article-title":"Automated task-transfer function measurement for CT image quality assessment based on AAPM TG 233","volume":"11","author":"Anam","year":"2025","journal-title":"J. Imaging"},{"key":"bpexae9e3abib16","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s41747-025-00656-0","type":"journal-article","article-title":"Ultra-high spatial resolution at photon-counting computed tomography: technical insights and sustainable applications in cardiothoracic imaging","volume":"10","author":"Occhipinti","year":"2026","journal-title":"Eur. Radiol. Exp."},{"key":"bpexae9e3abib17","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.1016\/j.ejrnm.2016.08.016","type":"journal-article","article-title":"Quality control of CT image using American College of Radiology (ACR) phantom","volume":"47","author":"Mansoura","year":"2016","journal-title":"Egypt J. Radiol. Nucl. Med."},{"key":"bpexae9e3abib18","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1120\/jacmp.v10i3.2844","type":"journal-article","article-title":"Simplified \u201con-couch\u201d daily quality assurance procedure for CT simulators","volume":"10","author":"Liu","year":"2009","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"bpexae9e3abib19","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1118\/1.595124","type":"journal-article","article-title":"A practical method to measure the MTF of CT scanners","volume":"9","author":"Droege","year":"1982","journal-title":"Med. Phys."},{"key":"bpexae9e3abib20","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1088\/1361-6560\/adec3a","type":"journal-article","article-title":"Comparative evaluation of uncertainty in MTF estimation in computed tomography using periodic bar patterns: analysis of the variance and harmonic methods","volume":"70","author":"Gonz\u00e1lez-l\u00f3pez","year":"2025","journal-title":"Phys. Med. Biol."},{"key":"bpexae9e3abib21","doi-asserted-by":"publisher","first-page":"2423","DOI":"10.1118\/1.1769632","type":"journal-article","article-title":"The phantom portion of the american college of radiology (ACR) computed tomography (CT) accreditation program: practical tips, artifact examples, and pitfalls to avoid","volume":"31","author":"McCollough","year":"2004","journal-title":"Med. Phys."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9e3a","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9e3a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9e3a","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9e3a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9e3a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9e3a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9e3a\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9e3a\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T06:03:54Z","timestamp":1788329034000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ae9e3a"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,2]]},"references-count":21,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,9,2]]},"published-print":{"date-parts":[[2026,10,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ae9e3a","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,2]]},"assertion":[{"value":"Development and validation of an automated MTF measurement method for five types of Catphan phantoms using bar pattern objects","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-13","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-08-25","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-02","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}