{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T10:49:25Z","timestamp":1792147765629,"version":"4.4.0"},"reference-count":70,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T00:00:00Z","timestamp":1792108800000},"content-version":"vor","delay-in-days":15,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T00:00:00Z","timestamp":1792108800000},"content-version":"tdm","delay-in-days":15,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Interdisciplinary Center for Interface Research"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,10,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:italic>Objective.<\/jats:italic>\n                    High-resolution peripheral quantitative computed tomography enables the assessment of bone mineral density and three-dimensional microstructure of peripheral limbs. Due to its long scanning time, it is especially susceptible to patient induced motion artifacts. The goal of this study is to compensate for such artifacts without requiring excessive computation time, while still avoiding the hallucination of erroneous structures.\n                    <jats:italic>Approach.<\/jats:italic>\n                    This work proposes a machine learning-based approach for the rapid estimation of rigid motion parameters directly from raw projection data. The model is trained on patient scans with motion simulated as a single, instantaneous jump. We demonstrate the performance and generalization of the method on simulated and experimentally acquired data, benchmarking our results against two recent baselines.\n                    <jats:italic>Main results.<\/jats:italic>\n                    The proposed method greatly reduced the amount of motion artifacts in both simulated and experimental data. On the simulated test data, the median structural similarity index measure (SSIM) for the reconstruction results could be improved from 0.62 to 0.88. Similarly, the SSIM for the experimental data improved from 0.58\u20130.71 to 0.74\u20130.78. At the tibia site that was used for training, motion artifacts were successfully reduced to such an extent that 92\u2009% of previously inaccessible scans could be reconsidered for clinical evaluation. For the unseen radius site, a clinical recovery rate of 56\u2009% could be achieved. Predicting the motion parameters for a measurement required less than 200 ms on consumer hardware.\n                    <jats:italic>Significance.<\/jats:italic>\n                    The proposed approach has the potential to enable the reuse of scans that were previously discarded for clinical evaluation while preventing generative hallucinations by design. Consequently, eliminating the need for repeated scans would reduce patient radiation exposure and clinical workflow overhead.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/aea857","type":"journal-article","created":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T22:48:17Z","timestamp":1789598897000},"page":"055052","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Data-driven motion compensation in HR-pQCT"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3475-8480","authenticated-orcid":true,"given":"Paul","family":"J\u00fcr\u00df","sequence":"first","affiliation":[{"name":"Institute for Biomedical Imaging, Hamburg University of Technology"},{"name":"University Medical Center Hamburg-Eppendorf"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1589-8517","authenticated-orcid":true,"given":"Tobias","family":"Knopp","sequence":"additional","affiliation":[{"name":"Institute for Biomedical Imaging, Hamburg University of Technology"},{"name":"University Medical Center Hamburg-Eppendorf"},{"name":"Fraunhofer Research Institution for Individualized and Cell-based Medical Engineering IMTE"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6586-6794","authenticated-orcid":false,"given":"Felix N","family":"von Brackel","sequence":"additional","affiliation":[{"name":"University Medical Center Hamburg-Eppendorf"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Amling","sequence":"additional","affiliation":[{"name":"University Medical Center Hamburg-Eppendorf"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3099-8073","authenticated-orcid":false,"given":"Bj\u00f6rn","family":"Busse","sequence":"additional","affiliation":[{"name":"University Medical Center Hamburg-Eppendorf"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-7765-4604","authenticated-orcid":true,"given":"Artyom","family":"Tsanda","sequence":"additional","affiliation":[{"name":"Institute for Biomedical Imaging, Hamburg University of Technology"},{"name":"University Medical Center Hamburg-Eppendorf"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3865-4603","authenticated-orcid":true,"given":"Fynn","family":"Foerger","sequence":"additional","affiliation":[{"name":"Institute for Biomedical Imaging, Hamburg University of Technology"},{"name":"University Medical Center Hamburg-Eppendorf"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4737-7863","authenticated-orcid":true,"given":"Martin","family":"M\u00f6ddel","sequence":"additional","affiliation":[{"name":"Institute for Biomedical Imaging, Hamburg University of Technology"},{"name":"University Medical Center Hamburg-Eppendorf"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3419-7481","authenticated-orcid":true,"given":"Marija","family":"Boberg","sequence":"additional","affiliation":[{"name":"Institute for Biomedical Imaging, Hamburg University of Technology"},{"name":"University Medical Center Hamburg-Eppendorf"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,10,16]]},"reference":[{"key":"bpexaea857bib1","doi-asserted-by":"publisher","first-page":"6228","DOI":"10.1002\/mp.16405","type":"journal-article","article-title":"Mitigation of motion-induced artifacts in cone beam computed tomography using deep convolutional neural networks","volume":"50","author":"Amirian","year":"2023","journal-title":"Med. Phys."},{"key":"bpexaea857bib2","doi-asserted-by":"publisher","first-page":"30088","DOI":"10.1073\/pnas.1907377117","type":"journal-article","article-title":"On instabilities of deep learning in image reconstruction and the potential costs of AI","volume":"117","author":"Antun","year":"2020","journal-title":"Proc. Natl Acad. Sci."},{"key":"bpexaea857bib3","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1007\/s00223-024-01299-w","type":"journal-article","article-title":"Sex-specific association patterns of bone microstructure and lower leg arterial calcification","volume":"115","author":"Bartosik","year":"2024","journal-title":"Calcif. Tissue Int."},{"key":"bpexaea857bib4","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1007\/s00223-023-01143-7","type":"journal-article","article-title":"Comparison of motion grading in 1,000 patients by first- and second-generation HR-pQCT: a propensity score matched cohort study","volume":"113","author":"Bartosik","year":"2023","journal-title":"Calcif. Tissue Int."},{"key":"bpexaea857bib5","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1118\/1.4941012","type":"journal-article","article-title":"Marker-free motion correction in weight-bearing cone-beam CT of the knee joint","volume":"43","author":"Berger","year":"2016","journal-title":"Med. Phys."},{"key":"bpexaea857bib6","doi-asserted-by":"publisher","first-page":"3249","DOI":"10.1109\/TMI.2021.3077857","type":"journal-article","article-title":"On hallucinations in tomographic image reconstruction","volume":"40","author":"Bhadra","year":"2021","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexaea857bib7","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.neuroimage.2013.04.082","type":"journal-article","article-title":"Motion artifacts in functional near-infrared spectroscopy: a comparison of motion correction techniques applied to real cognitive data","volume":"85","author":"Brigadoi","year":"2014","journal-title":"NeuroImage"},{"key":"bpexaea857bib8","doi-asserted-by":"publisher","first-page":"1488","DOI":"10.1109\/TIP.2011.2173206","type":"journal-article","article-title":"On the mathematical properties of the structural similarity index","volume":"21","author":"Brunet","year":"2012","journal-title":"IEEE Trans. Image Process."},{"key":"bpexaea857bib9","doi-asserted-by":"publisher","author":"Buzug","year":"2008","DOI":"10.1007\/978-3-540-39408-2","type":"book"},{"key":"bpexaea857bib10","doi-asserted-by":"publisher","DOI":"10.1117\/1.OE.57.2.023102","type":"journal-article","article-title":"General rigid motion correction for computed tomography imaging based on locally linear embedding","volume":"57","author":"Chen","year":"2018","journal-title":"Opt. Eng."},{"key":"bpexaea857bib11","doi-asserted-by":"publisher","first-page":"3309","DOI":"10.1002\/mp.17047","type":"journal-article","article-title":"Estimate and compensate head motion in non-contrast head CT scans using partial angle reconstruction and deep learning","volume":"51","author":"Chen","year":"2024","journal-title":"Med. Phys."},{"key":"bpexaea857bib12","doi-asserted-by":"publisher","DOI":"10.1118\/1.4873675","type":"journal-article","article-title":"Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment","volume":"41","author":"Choi","year":"2014","journal-title":"Med. Phys."},{"key":"bpexaea857bib13","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.3390\/jpm12061016","type":"journal-article","article-title":"HR-pQCT for the evaluation of muscle quality and intramuscular fat infiltration in ageing skeletal muscle","volume":"12","author":"Chow","year":"2022","journal-title":"J. Personalized Med."},{"key":"bpexaea857bib14","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1109\/42.500141","type":"journal-article","article-title":"Respiratory compensation in projection imaging using a magnification and displacement model","volume":"15","author":"Crawford","year":"1996","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexaea857bib15","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1007\/978-3-540-89208-3_120","type":"conference-proceedings","article-title":"Sinogram-Based Motion Detection in Transmission Computed Tomography","author":"Ens","year":"2009"},{"key":"bpexaea857bib16","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1016\/j.jocd.2016.10.005","type":"journal-article","article-title":"Muscle and myotendinous tissue properties at the distal tibia as assessed by high-resolution peripheral quantitative computed tomography","volume":"20","author":"Erlandson","year":"2017","journal-title":"J. Clin. Densitom."},{"key":"bpexaea857bib17","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1002\/mp.17413","type":"journal-article","article-title":"Reconstructing and analyzing the invariances of low-dose CT image denoising networks","volume":"52","author":"Eulig","year":"2025","journal-title":"Med. Phys."},{"key":"bpexaea857bib18","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/978-3-030-20351-1_20","type":"book","article-title":"Real-time 2D-3D deformable registration with deep learning and application to lung radiotherapy targeting","author":"Foote","year":"2019"},{"key":"bpexaea857bib19","first-page":"203","type":"journal-article","article-title":"Validation of high-resolution peripheral quantitative computed tomography-derived Achilles tendon properties against diagnostic ultrasound","volume":"22","author":"Fung","year":"2022","journal-title":"J. Musculoskelet. Neuronal Interact."},{"key":"bpexaea857bib20","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1109\/TMI.2008.923696","type":"journal-article","article-title":"Computational analysis and improvement of SIRT","volume":"27","author":"Gregor","year":"2008","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexaea857bib21","doi-asserted-by":"publisher","DOI":"10.1088\/0266-5611\/30\/3\/035008","type":"journal-article","article-title":"Efficient algorithms for linear dynamic inverse problems with known motion","volume":"30","author":"Hahn","year":"2014","journal-title":"Inverse Problems"},{"key":"bpexaea857bib22","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1007\/s11220-017-0159-6","type":"journal-article","article-title":"Motion estimation and compensation strategies in dynamic computerized tomography","volume":"18","author":"Hahn","year":"2017","journal-title":"Sens. Imaging"},{"key":"bpexaea857bib23","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1109\/CVPR.2016.90","type":"conference-proceedings","article-title":"Deep residual learning for image recognition","author":"He","year":"2016"},{"key":"bpexaea857bib24","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1016\/j.jocd.2020.11.001","type":"journal-article","article-title":"The assessment of skeletal muscle and cortical bone by second-generation HR-pQCT at the tibial midshaft","volume":"24","author":"Hildebrand","year":"2021","journal-title":"J. Clin. Densitom."},{"key":"bpexaea857bib25","doi-asserted-by":"publisher","first-page":"14NT01","DOI":"10.1088\/1361-6560\/ace1d0","type":"journal-article","article-title":"A patient-specific deep learning framework for 3D motion estimation and volumetric imaging during lung cancer radiotherapy","volume":"68","author":"Hindley","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"bpexaea857bib26","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac749a","type":"journal-article","article-title":"Reference-free learning-based similarity metric for motion compensation in cone-beam CT","volume":"67","author":"Huang","year":"2022","journal-title":"Phys. Med. Biol."},{"key":"bpexaea857bib27","doi-asserted-by":"publisher","first-page":"5240","DOI":"10.1109\/NSSMIC.2008.4774416","type":"conference-proceedings","article-title":"Compensating for head motion in slowly-rotating cone beam CT systems with optimization transfer based motion estimation","author":"Jacobson","year":"2008"},{"key":"bpexaea857bib28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/ISBI60581.2025.10981281","type":"conference-proceedings","article-title":"Optimization-based motion estimation in HR-pQCT","author":"J\u00fcr\u00df","year":"2025"},{"key":"bpexaea857bib29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00198-022-06567-9","type":"journal-article","article-title":"The need to distinguish intervention thresholds and diagnostic thresholds in the management of osteoporosis","volume":"34","author":"Kanis","year":"2023","journal-title":"Osteoporosis Int."},{"key":"bpexaea857bib30","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1137\/100796728","type":"journal-article","article-title":"Local tomography and the motion estimation problem","volume":"4","author":"Katsevich","year":"2011","journal-title":"SIAM J. Imaging Sci."},{"key":"bpexaea857bib31","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.compmedimag.2018.03.003","type":"journal-article","article-title":"Deformable respiratory motion correction for hepatic rotational angiography","volume":"66","author":"Klugmann","year":"2018","journal-title":"Comput. Med. Imaging Graph."},{"key":"bpexaea857bib32","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2020.101883","type":"journal-article","article-title":"Rigid and non-rigid motion artifact reduction in x-ray CT using attention module","volume":"67","author":"Ko","year":"2021","journal-title":"Med. Image Anal."},{"key":"bpexaea857bib33","doi-asserted-by":"publisher","first-page":"18TR02","DOI":"10.1088\/1361-6560\/ac093b","type":"journal-article","article-title":"Motion estimation and correction in SPECT, PET and CT","volume":"66","author":"Kyme","year":"2021","journal-title":"Phys. Med. Biol."},{"key":"bpexaea857bib34","doi-asserted-by":"publisher","first-page":"2651","DOI":"10.1088\/0031-9155\/53\/10\/014","type":"journal-article","article-title":"Real-time 3D motion tracking for small animal brain PET","volume":"53","author":"Kyme","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"bpexaea857bib35","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab79c4","type":"journal-article","article-title":"4D-CT deformable image registration using multiscale unsupervised deep learning","volume":"65","author":"Lei","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"bpexaea857bib36","article-title":"Auxiliary tasks in multi-task learning","author":"Liebel","year":"2018","type":"preprint"},{"key":"bpexaea857bib37","doi-asserted-by":"publisher","first-page":"1109","DOI":"10.1109\/42.963814","type":"journal-article","article-title":"Organ motion detection in CT images using opposite rays in fan-beam projection systems","volume":"20","author":"Linney","year":"2001","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexaea857bib38","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1118\/1.1381549","type":"journal-article","article-title":"Half-scan cone-beam CT fluoroscopy with multiple x-ray sources","volume":"28","author":"Liu","year":"2001","journal-title":"Med. Phys."},{"key":"bpexaea857bib39","doi-asserted-by":"publisher","DOI":"10.1016\/j.compmedimag.2019.06.001","type":"journal-article","article-title":"Motion estimation and correction in cardiac CT angiography images using convolutional neural networks","volume":"76","author":"Lossau","year":"2019","journal-title":"Comput. Med. Imaging Graph."},{"key":"bpexaea857bib40","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/978-3-642-15816-2_4","type":"book","article-title":"Morphological Image Processing Applied in Biomedicine","author":"Lotufo","year":"2011"},{"key":"bpexaea857bib41","doi-asserted-by":"publisher","first-page":"3559","DOI":"10.1002\/mp.14927","type":"journal-article","article-title":"Deep learning-based coronary artery motion estimation and compensation for short-scan cardiac CT","volume":"48","author":"Maier","year":"2021","journal-title":"Med. Phys."},{"key":"bpexaea857bib42","doi-asserted-by":"publisher","DOI":"10.1002\/mp.17911","type":"journal-article","article-title":"Deep learning-based cone-beam CT motion compensation with single-view temporal resolution","volume":"52","author":"Maier","year":"2025","journal-title":"Med. Phys."},{"key":"bpexaea857bib43","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.ejrad.2008.08.013","type":"journal-article","article-title":"Technical principles of dual source CT","volume":"68","author":"Petersilka","year":"2008","journal-title":"Eur. J. Radiol."},{"key":"bpexaea857bib44","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.bone.2011.10.003","type":"journal-article","article-title":"Visual grading of motion induced image degradation in high resolution peripheral computed tomography: impact of image quality on measures of bone density and micro-architecture","volume":"50","author":"Pialat","year":"2012","journal-title":"Bone"},{"key":"bpexaea857bib45","doi-asserted-by":"publisher","first-page":"3667","DOI":"10.1109\/TMI.2020.3002695","type":"journal-article","article-title":"Appearance learning for image-based motion estimation in tomography","volume":"39","author":"Preuhs","year":"2020","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexaea857bib46","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1186\/s12880-022-00914-2","type":"journal-article","article-title":"Motion artefact reduction in coronary CT angiography images with a deep learning method","volume":"22","author":"Ren","year":"2022","journal-title":"BMC Med. Imaging"},{"key":"bpexaea857bib47","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1109\/42.500142","type":"journal-article","article-title":"Correction of computed tomography motion artifacts using pixel-specific back-projection","volume":"15","author":"Ritchie","year":"1996","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexaea857bib48","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1109\/TRPMS.2025.3617225","type":"journal-article","article-title":"Simulating sinogram-domain motion and correcting image-domain artifacts using deep learning in HR-pQCT bone imaging","volume":"10","author":"Sadik","year":"2026","journal-title":"IEEE Trans. Radiat. Plasma Med. Sci."},{"key":"bpexaea857bib49","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.ics.2004.03.093","type":"journal-article","article-title":"Motion compensation for cone-beam CT based on 4D motion field of sinogram tracked markers","volume":"1268","author":"Sch\u00e4fer","year":"2004","journal-title":"Int. Congr. Ser."},{"key":"bpexaea857bib50","doi-asserted-by":"publisher","DOI":"10.1117\/12.2217243","type":"conference-proceedings","article-title":"Image-based motion compensation for high-resolution extremities cone-beam CT","volume":"9783","author":"Sisniega","year":"2016"},{"key":"bpexaea857bib51","doi-asserted-by":"publisher","first-page":"3712","DOI":"10.1088\/1361-6560\/aa6869","type":"journal-article","article-title":"Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion","volume":"62","author":"Sisniega","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"bpexaea857bib52","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/BIOSMART.2017.8095348","type":"conference-proceedings","article-title":"Segmentation of muscle and skeletal tissues in HR-pQCT images","author":"Snoussi","year":"2017"},{"key":"bpexaea857bib53","doi-asserted-by":"publisher","first-page":"1291","DOI":"10.1016\/j.bone.2011.03.755","type":"journal-article","article-title":"Quantitative characterization of subject motion in HR-pQCT images of the distal radius and tibia","volume":"48","author":"Sode","year":"2011","journal-title":"Bone"},{"key":"bpexaea857bib54","article-title":"Correction of motion artefacts in HR-pQCT using cycle-consistent adversarial networks","author":"Steiner","year":"2022","type":"conference-proceedings"},{"key":"bpexaea857bib55","doi-asserted-by":"publisher","first-page":"5705","DOI":"10.1118\/1.4963218","type":"journal-article","article-title":"An iterative projection-based motion estimation and compensation scheme for head x-ray CT","volume":"43","author":"Sun","year":"2016","journal-title":"Med. Phys."},{"key":"bpexaea857bib56","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1002\/mp.15354","type":"journal-article","article-title":"A deep learning method for eliminating head motion artifacts in computed tomography","volume":"49","author":"Su","year":"2022","journal-title":"Med. Phys."},{"key":"bpexaea857bib57","doi-asserted-by":"publisher","first-page":"25129","DOI":"10.1364\/OE.24.025129","type":"journal-article","article-title":"Fast and flexible x-ray tomography using the ASTRA toolbox","volume":"24","author":"van Aarle","year":"2016","journal-title":"Opt. Express"},{"key":"bpexaea857bib58","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.ultramic.2015.05.002","type":"journal-article","article-title":"The ASTRA toolbox: a platform for advanced algorithm development in electron tomography","volume":"157","author":"van Aarle","year":"2015","journal-title":"Ultramicroscopy"},{"key":"bpexaea857bib59","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1117\/12.2612986","type":"journal-article","article-title":"Motion-compensated targeting in pulmonary interventions using cone-beam CT and locally rigid\/globally deformable 3D-2D registration","volume":"12034","author":"Vijayan","year":"2022","journal-title":"Proc. SPIE"},{"key":"bpexaea857bib60","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1109\/TIP.2003.819861","type":"journal-article","article-title":"Image quality assessment: from error visibility to structural similarity","volume":"13","author":"Wang","year":"2004","journal-title":"IEEE Trans. Image Process."},{"key":"bpexaea857bib61","doi-asserted-by":"publisher","first-page":"137","DOI":"10.3109\/10929080009148884","type":"journal-article","article-title":"Online head motion tracking applied to the patient registration problem","volume":"5","author":"Westermann","year":"2000","journal-title":"Comput. Aided Surg."},{"key":"bpexaea857bib62","doi-asserted-by":"publisher","first-page":"1607","DOI":"10.1007\/s00198-020-05438-5","type":"journal-article","article-title":"Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography","volume":"31","author":"Whittier","year":"2020","journal-title":"Osteoporosis Int."},{"key":"bpexaea857bib63","doi-asserted-by":"publisher","first-page":"1357","DOI":"10.1118\/1.1739298","type":"journal-article","article-title":"Feldkamp-Type VOI reconstruction from super-short-scan cone-beam data","volume":"31","author":"Yu","year":"2004","journal-title":"Med. Phys."},{"key":"bpexaea857bib64","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1109\/TMI.2006.889717","type":"journal-article","article-title":"Data consistency based rigid motion artifact reduction in fan-beam CT","volume":"26","author":"Yu","year":"2007","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexaea857bib65","doi-asserted-by":"publisher","first-page":"1775","DOI":"10.1093\/bjr\/tqaf260","type":"journal-article","article-title":"Deep learning in CT image reconstruction and processing: techniques, performance evaluation, radiation dose and future perspective","volume":"98","author":"Yu","year":"2025","journal-title":"Br. J. Radiol."},{"key":"bpexaea857bib66","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1002\/jmri.24850","type":"journal-article","article-title":"Motion artifacts in MRI: a complex problem with many partial solutions","volume":"42","author":"Zaitsev","year":"2015","journal-title":"J. Magn. Reson. Imaging"},{"key":"bpexaea857bib67","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1007\/s00330-022-08971-5","type":"journal-article","article-title":"Motion artifact removal in coronary CT angiography based on generative adversarial networks","volume":"33","author":"Zhang","year":"2023a","journal-title":"Eur. Radiol."},{"key":"bpexaea857bib68","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acb30d","type":"journal-article","article-title":"Dynamic cone-beam CT reconstruction using spatial and temporal implicit neural representation learning (STINR)","volume":"68","author":"Zhang","year":"2023b","journal-title":"Phys. Med. Biol."},{"key":"bpexaea857bib69","doi-asserted-by":"publisher","first-page":"721","DOI":"10.3233\/XST-16193","type":"journal-article","article-title":"Rigid motion artifact reduction in CT using frequency domain analysis","volume":"25","author":"Zhang","year":"2017","journal-title":"J. X-ray Sci. Technol."},{"key":"bpexaea857bib70","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.2174\/2352096513999200606224154","type":"patent","article-title":"Rigid motion artifact reduction in CT using the phase correlation method","volume":"13","author":"Zhang","year":"2020"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aea857","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aea857\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aea857","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aea857\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aea857\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aea857\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aea857\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aea857\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T10:16:39Z","timestamp":1792145799000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aea857"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,1]]},"references-count":70,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,10,16]]},"published-print":{"date-parts":[[2026,10,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/aea857","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,1]]},"assertion":[{"value":"Data-driven motion compensation in HR-pQCT","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2026-02-13","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-10-16","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}