{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T08:00:02Z","timestamp":1790841602316,"version":"4.1.0"},"reference-count":33,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2026,10,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Stereotactic body radiotherapy (SBRT) for prostate cancer often uses high-energy photon beams, which can produce photoneutrons through interaction in the linac head, raising concerns regarding neutron-related exposure. Therefore, it is important to estimate neutron dose equivalent in SBRT plans when comparing beam energies and treatment delivery techniques. BD-PND fast neutron detectors were used in this study to quantify neutron dose equivalent in prostate SBRT plans. We performed dosimetry measurements using a Varian TrueBeam Linac and assessed neutron production at energies of 2.5 MV, 6 MV, 6 MV flattening filter free (FFF), 10 MV, 10 MV FFF and 15 MV. Bubble counts were converted to neutron dose equivalent using the manufacturer-provided calibration factor. The measured neutron dose equivalent was highest at the centre and decreased at peripheral measurement locations farther from the primary beam. Significant differences in neutron dose equivalent were found between flattening filter (FF) and FFF beams at the central beam position after multiple comparison correction. In contrast, peripheral positions showed no statistically significant differences. Additionally, low bubble counts were observed under 6 MV and 6 MV FFF beams, suggesting a low-level detector response under the present measurement conditions. Overall, beam energy, FF or FFF delivery and measurement positions all affect the measured neutron dose equivalent in prostate SBRT. The low-energy observation should be interpreted as preliminary, and additional work is needed, including repeated measurements, different detector types and more clinically relevant measurement locations.<\/jats:p>","DOI":"10.1088\/2057-1976\/aeaba9","type":"journal-article","created":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T22:48:13Z","timestamp":1790203693000},"page":"055036","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of neutron dose equivalent in prostate stereotactic body radiotherapy by bubble detector"],"prefix":"10.1088","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2104-7022","authenticated-orcid":true,"given":"Sali","family":"Di","sequence":"first","affiliation":[{"name":"BC Cancer Abbotsford"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-9183-0342","authenticated-orcid":true,"given":"Brandon","family":"VanGenderen","sequence":"additional","affiliation":[{"name":"BC Cancer Abbotsford"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus","family":"Sonier","sequence":"additional","affiliation":[{"name":"BC Cancer Abbotsford"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph","family":"Awotwi-Pratt","sequence":"additional","affiliation":[{"name":"BC Cancer Abbotsford"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"266","published-online":{"date-parts":[[2026,10,1]]},"reference":[{"key":"bpexaeaba9bib1","author":"Awotwi-Pratt","year":"2003","type":"book"},{"key":"bpexaeaba9bib2","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1007\/s10967-007-0325-8","type":"journal-article","article-title":"Measurement of photoneutrons in the output of 15 MV varian clinac 2100C LINAC using bubble detectors","volume":"271","author":"Awotwi-Pratt","year":"2007","journal-title":"J. Radioanal. Nucl."},{"key":"bpexaeaba9bib3","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.nimb.2006.05.020","type":"journal-article","article-title":"Bubble detector measurements of a mixed radiation field from antiproton annihilation","volume":"251","author":"Bassler","year":"2006","journal-title":"Nucl. Instrum. Methods Phys. Res. B"},{"key":"bpexaeaba9bib4","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1177\/1533034615592106","type":"journal-article","article-title":"Evaluation of photoneutron dose measured by bubble detectors in conventional linacs and cyberknife unit: effective dose and secondary malignancy risk estimation","volume":"15","author":"Biltekin","year":"2016","journal-title":"Technol. Cancer Res. Treat."},{"key":"bpexaeaba9bib5","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.ijrobp.2021.03.053","type":"journal-article","article-title":"Risk of cardiac implantable electronic device malfunctioning during pencil beam proton scanning in an in vitro setting","volume":"111","author":"Bjerre","year":"2021","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"bpexaeaba9bib6","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1093\/oxfordjournals.rpd.a032203","type":"journal-article","article-title":"Use of bubble detectors to measure neutron contamination of a medical accelerator photon beam","volume":"74","author":"Bourgois","year":"1997","journal-title":"Radiat. Prot. Dosim."},{"key":"bpexaeaba9bib7","first-page":"122","type":"journal-article","article-title":"The OpenCV Library","volume":"120","author":"Bradski","year":"2000","journal-title":"DrDobb\u2019s J. Softw. Tools"},{"key":"bpexaeaba9bib8","doi-asserted-by":"publisher","first-page":"111531","DOI":"10.1016\/S1470-2045(19)30569-8","type":"journal-article","article-title":"Intensity-modulated fractionated radiotherapy versus stereotactic body radiotherapy for prostate cancer (PACE-B): acute toxicity findings from an international, randomised, open-label, phase 3, non-inferiority trial","volume":"20","author":"Brand","year":"2019","journal-title":"Lancet Oncol."},{"key":"bpexaeaba9bib9","doi-asserted-by":"publisher","first-page":"3338","DOI":"10.1002\/mp.16416","type":"journal-article","article-title":"Measurement of neutron yield for a medical linear accelerator below 10 MV","volume":"50","author":"Carlone","year":"2023","journal-title":"Med. Phys."},{"key":"bpexaeaba9bib10","doi-asserted-by":"publisher","first-page":"4018","DOI":"10.1118\/1.3598439","type":"journal-article","article-title":"Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: dose and IAEA-compliant phase space calculations","volume":"38","author":"Constantin","year":"2011","journal-title":"Med. Phys."},{"key":"bpexaeaba9bib11","doi-asserted-by":"publisher","first-page":"1769","DOI":"10.1109\/23.101190","type":"journal-article","article-title":"The application of the bubble detector to the measurement of intense neutron fluences and energy spectra","volume":"37","author":"Cousins","year":"1990","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"bpexaeaba9bib12","article-title":"Use of bubble detectors to characterize neutron dose distribution in a radiotherapy treatment room used for imrt treatments 12th Congress of the Int. Radiation Protection Association","author":"Hudson","year":"2009","type":"other"},{"key":"bpexaeaba9bib13","author":"IAEA","year":"2000","type":"book"},{"key":"bpexaeaba9bib14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S1350-4487(96)00156-4","type":"journal-article","article-title":"Bubble detectors\u2014A maturing technology","volume":"27","author":"Ing","year":"1997","journal-title":"Radiat. Meas."},{"key":"bpexaeaba9bib15","doi-asserted-by":"crossref","DOI":"10.2172\/1448399","type":"other","article-title":"BD-100: the chalk river nuclear laboratories\u2019 neutron bubble detector","author":"Ipe","year":"1987"},{"key":"bpexaeaba9bib16","doi-asserted-by":"publisher","first-page":"1899","DOI":"10.4103\/jcrt.jcrt_1465_21","type":"journal-article","article-title":"Comparison and estimation of photoneutron dose produce between 10 MV flattened and unflattened beam in Elekta Versa HD\u2122 medical linac","volume":"19","author":"Khilafath","year":"2023","journal-title":"J. Cancer Res. Ther."},{"key":"bpexaeaba9bib17","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1080\/18811248.2007.9711261","type":"journal-article","article-title":"Assessment and measurement of the photoneutron field produced in the varian medical linear accelerator","volume":"44","author":"Kim","year":"2007","journal-title":"J. Nucl. Sci. Technol."},{"key":"bpexaeaba9bib18","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1001\/jamanetworkopen.2018.8006","type":"journal-article","article-title":"Long-term outcomes of stereotactic body radiotherapy for low-risk and intermediate-risk prostate cancer","volume":"2","author":"Kishan","year":"2019","journal-title":"JAMA Netw. Open"},{"key":"bpexaeaba9bib19","author":"Knoll","year":"2010","type":"book"},{"key":"bpexaeaba9bib20","doi-asserted-by":"publisher","first-page":"e391","DOI":"10.1002\/mp.12462","type":"journal-article","article-title":"AAPM TG 158: measurement and calculation of doses outside the treated volume from external-beam radiation therapy","volume":"44","author":"Kry","year":"2017","journal-title":"Med. Phys."},{"key":"bpexaeaba9bib21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/rpd\/ncr358","type":"journal-article","article-title":"Review of bubble detector response characteristics and results from space","volume":"150","author":"Lewis","year":"2012","journal-title":"Radiat. Prot. Dosim."},{"key":"bpexaeaba9bib22","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1016\/j.apradiso.2007.01.017","type":"journal-article","article-title":"Investigation of photoneutron dose equivalent from high-energy photons in radiotherapy","volume":"65","author":"Lin","year":"2007","journal-title":"Appl. Radiat. Isot."},{"key":"bpexaeaba9bib23","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.clon.2016.10.001","type":"journal-article","article-title":"Stereotactic ablative radiotherapy versus low dose rate brachytherapy or external beam radiotherapy: propensity score matched analyses of canadian data","volume":"29","author":"Loblaw","year":"2017","journal-title":"Clin. Oncol."},{"key":"bpexaeaba9bib24","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1007\/s12194-023-00705-6","type":"journal-article","article-title":"Neutron dose from a 6-MV x-ray beam in radiotherapy","volume":"16","author":"Matsubara","year":"2023","journal-title":"Radiol. Phys. Technol."},{"key":"bpexaeaba9bib25","doi-asserted-by":"publisher","first-page":"1489","DOI":"10.1002\/mp.14057","type":"journal-article","article-title":"Prediction of radiation-induced malfunction for cardiac implantable electronic devices (CIEDs)","volume":"47","author":"Matsubara","year":"2020","journal-title":"Med. Phys."},{"key":"bpexaeaba9bib26","doi-asserted-by":"publisher","first-page":"e757","DOI":"10.1002\/mp.13838","type":"journal-article","article-title":"Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: a Report of the AAPM TG-203\u2020","volume":"46","author":"Miften","year":"2019","journal-title":"Med. Phys."},{"key":"bpexaeaba9bib27","doi-asserted-by":"publisher","first-page":"4711","DOI":"10.1002\/mp.13148","type":"journal-article","article-title":"The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator","volume":"45","author":"Montgomery","year":"2018","journal-title":"Med. Phys."},{"key":"bpexaeaba9bib28","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1016\/j.prro.2018.08.002","type":"journal-article","article-title":"Hypofractionated radiation therapy for localized prostate cancer: executive summary of an ASTRO, ASCO, and AUA evidence-based guideline","volume":"8","author":"Morgan","year":"2018","journal-title":"Pract. Radiat. Oncol."},{"key":"bpexaeaba9bib29","author":"Nath","year":"1987","type":"report"},{"key":"bpexaeaba9bib30","doi-asserted-by":"publisher","DOI":"10.1051\/epjconf\/201715301027","type":"journal-article","article-title":"Activation of dosimeters used in qa of medical linear accelerators","volume":"153","author":"Polaczek-Grelik","year":"2017","journal-title":"EPJ Web Conf."},{"key":"bpexaeaba9bib31","doi-asserted-by":"publisher","first-page":"473","DOI":"10.4103\/jmp.jmp_70_24","type":"journal-article","article-title":"Photon and neutron dose estimation using monte carlo simulation in truebeam\u2019s room","volume":"49","author":"Quoc","year":"2024","journal-title":"J. Med. Phys."},{"key":"bpexaeaba9bib32","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1118\/1.1463063","type":"journal-article","article-title":"Dose to radiation therapists from activation at high-energy accelerators used for conventional and intensity-modulated radiation therapy","volume":"29","author":"Rawlinson","year":"2002","journal-title":"Med. Phys."},{"key":"bpexaeaba9bib33","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1093\/oxfordjournals.rpd.a032850","type":"journal-article","article-title":"The life span of the BD-PND bubble detector","volume":"85","author":"Vanhavere","year":"1999","journal-title":"Radiat. Prot. Dosimet."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aeaba9","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aeaba9\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aeaba9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aeaba9\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aeaba9\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aeaba9\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aeaba9\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aeaba9\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T07:25:22Z","timestamp":1790839522000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aeaba9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,1]]},"references-count":33,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,10,1]]},"published-print":{"date-parts":[[2026,10,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/aeaba9","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,1]]},"assertion":[{"value":"Evaluation of neutron dose equivalent in prostate stereotactic body radiotherapy by bubble detector","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-12","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-23","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-10-01","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}