{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T06:29:54Z","timestamp":1793600994358,"version":"4.5.0"},"reference-count":206,"publisher":"IOP Publishing","issue":"4","license":[{"start":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T00:00:00Z","timestamp":1793577600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T00:00:00Z","timestamp":1793577600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"National Natural Science Foundation of China","award":["82027806"],"award-info":[{"award-number":["82027806"]}],"id":[{"id":"https:\/\/ror.org\/01h0zpd94","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Prog. Biomed. Eng."],"published-print":{"date-parts":[[2026,12,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Cancer is a serious worldwide health issue. Routinary detection exams are recommended for better prognosis, however there are still no suitable routinary procedures. Electrical impedance tomography (EIT) is a non-invasive, portable, low-cost novel imaging technology. Its side effects are reversible heat discomfort and\/or uncomfortable electrostimulation. By measuring the dielectric properties of a region of interest, it makes possible to detect and monitor cancer. Software such as Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software and COMSOL are used nowadays to solve the forward and inverse problem. However, the state-of-the-art image reconstruction solutions are based on deep learning and this ongoing research has boosted the accuracy of EIT in a substantial manner. With such accuracy improvement, this technique has been utilized for breast cancer detection. The successful results for breast cancer encouraged researchers to explore its usage in other cancer types such as lung, skin, prostate, tongue and gynaecological. Results reaffirm that EIT holds great potential to be used in clinical cancer diagnostic scenarios and thus, more exhaustive research of EIT-based cancer imaging is highly recommended. This review offers an overview of the main elements that EIT technology comprises. Detailed explanation is provided for safety parameters and possible adverse effects. A comprehensive overview of deep tomographic image reconstruction in EIT is provided. Finally, an updated literature revision for EIT usage in the oncological area is presented.<\/jats:p>","DOI":"10.1088\/2516-1091\/aead6c","type":"journal-article","created":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T22:57:24Z","timestamp":1790636244000},"page":"042005","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Emerging horizons in cancer monitoring: electrical impedance tomography as a cost-effective noninvasive imaging and diagnostics system"],"prefix":"10.1088","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-5971-1316","authenticated-orcid":true,"given":"Jesus Alejandro","family":"Martinez Juarez","sequence":"first","affiliation":[{"name":"Southeast University"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-4838-121X","authenticated-orcid":true,"given":"Miraj ud","family":"din","sequence":"additional","affiliation":[{"name":"Southeast University"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"validation","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8044-758X","authenticated-orcid":true,"given":"Hui","family":"Jiang","sequence":"additional","affiliation":[{"name":"Southeast University"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"}]},{"given":"Xiaohui","family":"Liu","sequence":"additional","affiliation":[{"name":"Southeast University"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6882-7774","authenticated-orcid":true,"given":"Xuemei","family":"Wang","sequence":"additional","affiliation":[{"name":"Southeast University"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"funding-acquisition","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"resources","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"}]}],"member":"266","published-online":{"date-parts":[[2026,11,2]]},"reference":[{"key":"prgbaead6cbib1","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1158\/1055-9965.EPI-15-0578","type":"journal-article","article-title":"Global cancer incidence and mortality rates and trends\u2014an update","volume":"25","author":"Torre","year":"2016","journal-title":"Cancer Epidemiol. Biomarkers Prev."},{"key":"prgbaead6cbib2","article-title":"Can chronic myeloid leukemia be found early?","author":"American Cancer Society","type":"web-resource"},{"key":"prgbaead6cbib3","article-title":"Can prostate cancer be found early? | How to detect prostate cancer?","author":"American Cancer Society","type":"web-resource"},{"key":"prgbaead6cbib4","article-title":"How to detect mouth cancer early","author":"American Cancer Society","type":"web-resource"},{"key":"prgbaead6cbib5","article-title":"Lung cancer early detection | lung cancer screening","author":"American Cancer Society","type":"web-resource"},{"key":"prgbaead6cbib6","doi-asserted-by":"publisher","DOI":"10.1088\/1757-899X\/331\/1\/012004","type":"journal-article","article-title":"Applications of electrical impedance tomography (EIT): a short review","volume":"331","author":"Bera","year":"2018","journal-title":"IOP Conf. Ser.: Mater. Sci. Eng."},{"key":"prgbaead6cbib7","doi-asserted-by":"publisher","DOI":"10.1145\/3472749.3474758","type":"conference-proceedings","article-title":"EIT-kit: an electrical impedance tomography toolkit for health and motion sensing","author":"Zhu","year":"2021"},{"key":"prgbaead6cbib8","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1145\/2807442.2807480","type":"conference-proceedings","article-title":"Tomo: wearable, low-cost electrical impedance tomography for hand gesture recognition","author":"Zhang","year":"2015"},{"key":"prgbaead6cbib9","doi-asserted-by":"publisher","first-page":"595","DOI":"10.32598\/bcn.2021.3087.1","type":"journal-article","article-title":"Applications of electrical impedance tomography in neurology","volume":"13","author":"Mirhoseini","year":"2022","journal-title":"Basic Clin. Neurosci."},{"key":"prgbaead6cbib10","type":"book","article-title":"EIT for measurement of lung function","author":"Frerichs","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib11","type":"book","article-title":"EIT for monitoring of ventilation","author":"Becher","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib12","type":"book","article-title":"EIT imaging of brain and nerves","author":"Holder","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib13","type":"book","article-title":"EIT monitoring of hemodynamic","author":"Krukewitt","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib14","article-title":"Mathematical modeling of EMF energy absorption in biological systems","author":"Gajsek","year":"2003","type":"book"},{"key":"prgbaead6cbib15","article-title":"DIELECTRIC PROPERTIES OF BIOLOGICAL TISSUE","author":"Klauenberg","year":"2000","type":"book"},{"key":"prgbaead6cbib16","type":"book","article-title":"Dielectric properties of tissues","author":"Polk","year":"1995","edition":"3rd edn"},{"key":"prgbaead6cbib17","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1088\/0031-9155\/41\/11\/001","type":"journal-article","article-title":"The dielectric properties of biological tissues: i. Literature survey","volume":"41","author":"Gabriel","year":"1996","journal-title":"Phys. Med. Biol."},{"key":"prgbaead6cbib18","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1021\/acsmeasuresciau.2c00033","type":"journal-article","article-title":"Bioelectrical impedance spectroscopy for monitoring mammalian cells and tissues under different frequency domains: a review","volume":"2","author":"Abasi","year":"2022","journal-title":"ACS Meas. Sci. Au"},{"key":"prgbaead6cbib19","type":"book","article-title":"Introduction to EIT. Concepts and technology","author":"Holder","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib20","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1007\/s11517-022-02763-1","type":"journal-article","article-title":"A review of bio-impedance devices","volume":"61","author":"Showkat","year":"2023","journal-title":"Med. Biol. Eng. Comput."},{"key":"prgbaead6cbib21","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/9210258","type":"journal-article","article-title":"Fundamentals, recent advances, and future challenges in bioimpedance devices for healthcare applications","volume":"2019","author":"Naranjo-Hern\u00c1ndez D, Reina-Tosina J","year":"2019","journal-title":"J. Sens."},{"key":"prgbaead6cbib22","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/9475490","type":"journal-article","article-title":"Cells electrical characterization: dielectric properties, mixture, and modeling theories","volume":"2020","author":"Nasir","year":"2020","journal-title":"J. Eng."},{"key":"prgbaead6cbib23","first-page":"p 73","type":"book","article-title":"Dielectric properties of biological materials","author":"Camelia","year":"2007","edition":"3rd edn"},{"key":"prgbaead6cbib24","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/B978-0-323-46140-5.00010-8","type":"book","article-title":"Dielectric spectroscopy","author":"Deshmukh","year":"2017"},{"key":"prgbaead6cbib25","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1109\/TDEI.2003.1237324","type":"journal-article","article-title":"Time domain dielectric spectroscopy study of biological systems","volume":"10","author":"Feldman","year":"2003","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"prgbaead6cbib26","article-title":"Electromagnetic waves and dielectric spectroscopy","author":"Kaatze","year":"2015","type":"book"},{"key":"prgbaead6cbib27","doi-asserted-by":"publisher","first-page":"14TR01","DOI":"10.1088\/1361-6560\/ac7b64","type":"other","article-title":"Measurement and image-based estimation of dielectric properties of biological tissues\u2014past, present, and future\u2014","volume":"67","author":"Sasaki","year":"2022"},{"key":"prgbaead6cbib28","doi-asserted-by":"publisher","first-page":"7","DOI":"10.3390\/s150715363","type":"journal-article","article-title":"Fruit and vegetable quality assessment via dielectric sensing","volume":"15","author":"Khaled","year":"2015","journal-title":"Sensors"},{"key":"prgbaead6cbib29","author":"Rohde & Schwarz","year":"2002","type":"book"},{"key":"prgbaead6cbib30","article-title":"Solutions for measuring permittivity and permeability with LCR meters and impedance analyzers. application note 1369-1","author":"Keysight","year":"2021","type":"other"},{"key":"prgbaead6cbib31","article-title":"Techniques for material research. Six dielectric measurements","author":"Keysight","type":"web-resource"},{"key":"prgbaead6cbib32","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2022.1011941","type":"journal-article","article-title":"Characteristics and topic trends on electrical impedance tomography hardware publications","volume":"13","author":"Qin","year":"2022","journal-title":"Front. Physiol."},{"key":"prgbaead6cbib33","doi-asserted-by":"publisher","first-page":"18","DOI":"10.3390\/s20185160","type":"journal-article","article-title":"A review on electrical impedance tomography spectroscopy","volume":"20","author":"Padilha Leitzke","year":"2020","journal-title":"Sensors"},{"key":"prgbaead6cbib34","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2023.e15195","type":"journal-article","article-title":"Robust electrical impedance tomography for biological application: a mini review","volume":"9","author":"Li","year":"2023","journal-title":"Heliyon"},{"key":"prgbaead6cbib35","first-page":"p 79","type":"book","article-title":"The EIT forward problem","author":"Adler","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib36","first-page":"109","type":"book","article-title":"The EIT Inverse Problem","author":"Adler","year":"2022","edition":"2nd"},{"key":"prgbaead6cbib37","doi-asserted-by":"publisher","first-page":"88","DOI":"10.3390\/a12050088","type":"journal-article","article-title":"Review on electrical impedance tomography: artificial intelligence methods and its applications","volume":"12","author":"Khan","year":"2019","journal-title":"Algorithms"},{"key":"prgbaead6cbib38","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2022.1019531","type":"journal-article","article-title":"Advances of deep learning in electrical impedance tomography image reconstruction","volume":"10","author":"Zhang","year":"2022","journal-title":"Front. Bioeng. Biotechnol."},{"key":"prgbaead6cbib39","doi-asserted-by":"publisher","first-page":"3","DOI":"10.3390\/s23031182","type":"journal-article","article-title":"Electrical impedance tomography: from the traditional design to the novel frontier of wearables","volume":"23","author":"Pennati","year":"2023","journal-title":"Sensors"},{"key":"prgbaead6cbib40","doi-asserted-by":"publisher","first-page":"1917","DOI":"10.1007\/s00134-012-2684-z","type":"journal-article","article-title":"Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?","volume":"38","author":"Leonhardt","year":"2012","journal-title":"Intensive Care Med."},{"key":"prgbaead6cbib41","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0191870","type":"journal-article","article-title":"Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers","volume":"13","author":"Braun","year":"2018","journal-title":"PLoS One"},{"key":"prgbaead6cbib42","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1016\/j.arcontrol.2019.05.002","type":"journal-article","article-title":"A review of electrical impedance tomography in lung applications: theory and algorithms for absolute images","volume":"48","author":"de Martins","year":"2019","journal-title":"Annu. Rev. Control"},{"key":"prgbaead6cbib43","doi-asserted-by":"publisher","first-page":"07TR01","DOI":"10.1088\/1361-6579\/adf16e","type":"journal-article","article-title":"Clinical applications of thoracic electrical impedance tomography in China: an updated review on recent 5 years","volume":"46","author":"Yuan","year":"2025","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib44","article-title":"Electric impedance tomography market\u2014trends, opportunities, and competitive landscape","author":"Grand View Research","type":"web-resource"},{"key":"prgbaead6cbib45","doi-asserted-by":"publisher","first-page":"p 8","DOI":"10.1201\/9780429399886\/electrical-impedance-tomography-david-holder-andy-adler)","type":"book","article-title":"Electrical Impedance Tomography","author":"Adler","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib46","article-title":"Finite element method basics\u2014MATLAB & Simulink\u2014MathWorks China","author":"The MathWorks, Inc.","type":"web-resource"},{"key":"prgbaead6cbib47","article-title":"Introduction to the finite element method","author":"Papadopoulos","year":"2015","type":"book"},{"key":"prgbaead6cbib48","article-title":"introduction to finite element analysis (fea) or finite element method (FEM)","author":"M.E.S. Dept. University of Victoria","type":"web-resource"},{"key":"prgbaead6cbib49","article-title":"Construction of finite element subspaces","author":"Papadopoulos","year":"2015","type":"book"},{"key":"prgbaead6cbib50","article-title":"EIDORS","author":"Adler","type":"web-resource"},{"key":"prgbaead6cbib51","article-title":"Python","author":"eitcom\/pyEIT","year":"2023","type":"web-resource"},{"key":"prgbaead6cbib52","article-title":"Netgen\/NGSolve","author":"Netgen\/NGSolve team","type":"web-resource"},{"key":"prgbaead6cbib53","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1088\/0967-3334\/27\/5\/S03","type":"journal-article","article-title":"Uses and abuses of EIDORS: an extensible software base for EIT","volume":"27","author":"Adler","year":"2006","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib54","article-title":"EIDORS: the past, the present and the future","author":"Grychtol","type":"web-resource"},{"key":"prgbaead6cbib55","article-title":"EIDORS: towards a community-based extensible software base for EIT","author":"Adler","year":"2005","type":"other"},{"key":"prgbaead6cbib56","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1109\/TMI.2012.2200904","type":"journal-article","article-title":"Impact of model shape mismatch on reconstruction quality in electrical impedance tomography","volume":"31","author":"Grychtol","year":"2012","journal-title":"IEEE Trans. Med. Imaging"},{"key":"prgbaead6cbib57","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1109\/USBEREIT48449.2020.9117667","type":"conference-proceedings","article-title":"Electrical impedance tomography data acquisition emulation","author":"Artakovich","year":"2020"},{"key":"prgbaead6cbib58","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/ASEEZone1.2014.6820674","type":"conference-proceedings","article-title":"The enhancement of students learning through COMSOL simulation projects","author":"Ngabonziza","year":"2014"},{"key":"prgbaead6cbib59","article-title":"Flexible numerical platform for electrical impedance tomography","author":"Fouchard","year":"2015","type":"other"},{"key":"prgbaead6cbib60","doi-asserted-by":"publisher","first-page":"1","DOI":"10.2139\/ssrn.3867446","type":"journal-article","article-title":"Simulation of forward problem for non-invasive two dimensional electrical impedance tomography system using eidors and COMSOL multiphysics","volume":"411","author":"Naik","year":"2021","journal-title":"SSRN Electron. J."},{"key":"prgbaead6cbib61","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1109\/TSP55681.2022.9851291","type":"conference-proceedings","article-title":"Electrical impedance tomography simulation for detection of breast tumors based on tumor emulators","author":"G\u00f3mez Cort\u00e9s","year":"2022"},{"key":"prgbaead6cbib62","doi-asserted-by":"publisher","DOI":"10.1016\/j.measen.2024.101416","type":"journal-article","article-title":"Simulation framework for electrical impedance tomography systems","volume":"38","author":"Hollenberg","year":"2025","journal-title":"Meas. Sens."},{"key":"prgbaead6cbib63","doi-asserted-by":"publisher","first-page":"1008","DOI":"10.1007\/978-3-031-44630-6_80","type":"conference-proceedings","article-title":"Modeling bio-impedance measurement in a reconstructed model from MRI images for developing electrical impedance tomography application","author":"Nguyen Diep","year":"2024"},{"key":"prgbaead6cbib64","doi-asserted-by":"publisher","first-page":"7333","DOI":"10.3934\/math.2021431","type":"journal-article","article-title":"Sensitivity analysis of the complete electrode model for electrical impedance tomography","volume":"6","author":"Darbas","year":"2021","journal-title":"AIMS Math."},{"key":"prgbaead6cbib65","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1016\/j.mric.2011.05.011","type":"journal-article","article-title":"Normal MR imaging anatomy of the thigh and leg","volume":"19","author":"Vohra","year":"2011","journal-title":"Magn. Reson. Imaging Clin."},{"key":"prgbaead6cbib66","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1007\/978-981-19-7346-8_36","type":"book","article-title":"Forward solver for electrical impedance tomography system for detection of breast cancer using simulation","author":"Hankare","year":"2023"},{"key":"prgbaead6cbib67","article-title":"EIDORS-Matlab interface for forward problem solving of electrical impedance tomography","author":"Mosquera","year":"2019","type":"other"},{"key":"prgbaead6cbib68","doi-asserted-by":"publisher","first-page":"4887","DOI":"10.1109\/TIM.2019.2954722","type":"journal-article","article-title":"A two-stage deep learning method for robust shape reconstruction with electrical impedance tomography","volume":"69","author":"Ren","year":"2020","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"prgbaead6cbib69","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1007\/s12204-021-2333-1","type":"journal-article","article-title":"Survey of EIT image reconstruction algorithms","volume":"27","author":"Zhang","year":"2022","journal-title":"J. Shanghai Jiaotong Univ. Sci."},{"key":"prgbaead6cbib70","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1007\/s10851-023-01169-4","type":"journal-article","article-title":"Comparison of two linearization-based methods for 3-D EIT reconstructions on a simulated chest","volume":"66","author":"Shin","year":"2024","journal-title":"J. Math. Imaging Vis."},{"key":"prgbaead6cbib71","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1002\/ima.1850020203","type":"journal-article","article-title":"NOSER: an algorithm for solving the inverse conductivity problem","volume":"2","author":"Cheney","year":"1990","journal-title":"Int. J. Imaging Syst. Technol."},{"key":"prgbaead6cbib72","doi-asserted-by":"publisher","first-page":"4085","DOI":"10.1109\/TMI.2020.3012428","type":"journal-article","article-title":"Introduction of sample based prior into the D-bar method through a Schur complement property","volume":"39","author":"Santos","year":"2020","journal-title":"IEEE Trans. Med. Imaging"},{"key":"prgbaead6cbib73","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1007\/s10921-025-01178-w","type":"journal-article","article-title":"The effect of different regularization approaches on damage imaging via electrical impedance tomography","volume":"44","author":"Tallman","year":"2025","journal-title":"J. Nondestruct. Eval."},{"key":"prgbaead6cbib74","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejmp.2020.11.012","type":"web-resource","article-title":"Artificial intelligence in image reconstruction: the change is here","author":"Singh","year":"2020"},{"key":"prgbaead6cbib75","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1007\/978-3-030-92087-6_13","type":"book","article-title":"Artificial intelligence for image enhancement and reconstruction in magnetic resonance imaging","author":"Hammernik","year":"2022"},{"key":"prgbaead6cbib76","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1007\/978-3-030-92087-6_14","type":"book","article-title":"Artificial intelligence-based image reconstruction in cardiac magnetic resonance","author":"Qin","year":"2022"},{"key":"prgbaead6cbib77","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1007\/978-3-030-92087-6_40","type":"book","article-title":"Artificial intelligence-based evaluation of patients with Chronic Obstructive Pulmonary Disease (COPD)","author":"Decker","year":"2022"},{"key":"prgbaead6cbib78","article-title":"A neural networks deep dive","author":"Jones","type":"web-resource"},{"key":"prgbaead6cbib79","doi-asserted-by":"publisher","DOI":"10.1109\/9780470546826.ch3","type":"conference-proceedings","article-title":"Neural network paradigms","author":"Kartalopoulos","year":"2009"},{"key":"prgbaead6cbib80","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1109\/5.58323","type":"journal-article","article-title":"30 years of adaptive neural networks: perceptron, Madaline, and backpropagation","volume":"78","author":"Widrow","year":"1990","journal-title":"Proc. IEEE"},{"key":"prgbaead6cbib81","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1007\/s42979-021-00815-1","type":"journal-article","article-title":"Deep learning: a comprehensive overview on techniques, taxonomy, applications and research directions","volume":"2","author":"Sarker","year":"2021","journal-title":"SN Comput. Sci."},{"key":"prgbaead6cbib82","article-title":"AI vs. machine learning vs. deep learning vs. neural networks: what\u2019s the difference?","author":"I.D. and A. Team","type":"web-resource"},{"key":"prgbaead6cbib83","article-title":"Neural networks vs deep learning\u2014difference between artificial intelligence fields\u2014AWS","author":"Amazon Web Services, Inc.","type":"web-resource"},{"key":"prgbaead6cbib84","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1038\/s42256-020-00273-z","type":"journal-article","article-title":"Deep learning for tomographic image reconstruction","volume":"2","author":"Wang","year":"2020","journal-title":"Nat. Mach. Intell."},{"key":"prgbaead6cbib85","article-title":"A neural network approach to image reconstruction","author":"Guardo","year":"1991","type":"conference-proceedings"},{"key":"prgbaead6cbib86","doi-asserted-by":"crossref","DOI":"10.1109\/IEMBS.1993.978537","type":"conference-proceedings","article-title":"Image reconstruction in electrical impedance tomography: a neural network approach","author":"Adler","year":"1993"},{"key":"prgbaead6cbib87","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/MLSP49062.2020.9231818","type":"conference-proceedings","article-title":"Anomaly location detection with electrical impedance tomography using multilayer perceptrons","author":"Huuhtanen","year":"2020"},{"key":"prgbaead6cbib88","doi-asserted-by":"publisher","first-page":"3585","DOI":"10.1109\/ICIP.2017.8296950","type":"conference-proceedings","article-title":"An image reconstruction framework based on deep neural network for electrical impedance tomography","author":"Li","year":"2017"},{"key":"prgbaead6cbib89","doi-asserted-by":"publisher","first-page":"4035","DOI":"10.1177\/0142331219845037","type":"journal-article","article-title":"A novel deep neural network method for electrical impedance tomography","volume":"41","author":"Li","year":"2019","journal-title":"Trans. Inst. Meas. Control"},{"key":"prgbaead6cbib90","doi-asserted-by":"publisher","first-page":"2546","DOI":"10.1109\/TBME.2019.2891676","type":"journal-article","article-title":"Dominant-current deep learning scheme for electrical impedance tomography","volume":"66","author":"Wei","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"prgbaead6cbib91","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-319-24574-4_28","type":"preprint","article-title":"U-net: convolutional networks for biomedical image segmentation","author":"Ronneberger","year":"2015"},{"key":"prgbaead6cbib92","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/I2MTC43012.2020.9128764","type":"conference-proceedings","article-title":"Deep learning based cell imaging with electrical impedance tomography","author":"Chen","year":"2020"},{"key":"prgbaead6cbib93","doi-asserted-by":"publisher","first-page":"1570","DOI":"10.1109\/TRO.2021.3060342","type":"journal-article","article-title":"Deep neural network based electrical impedance tomographic sensing methodology for large-area robotic tactile sensing","volume":"37","author":"Park","year":"2021","journal-title":"IEEE Trans. Robot."},{"key":"prgbaead6cbib94","doi-asserted-by":"publisher","first-page":"17205","DOI":"10.1007\/s00500-020-05013-4","type":"journal-article","article-title":"RecDNN: deep neural network for image reconstruction from limited view projection data","volume":"24","author":"Kalare","year":"2020","journal-title":"Soft Comput."},{"key":"prgbaead6cbib95","doi-asserted-by":"publisher","first-page":"1092","DOI":"10.1109\/SSD54932.2022.9955888","type":"conference-proceedings","article-title":"Post-processing for thorax imaging based on electrical impedance tomography using deep learning","author":"Haddad","year":"2022"},{"key":"prgbaead6cbib96","doi-asserted-by":"publisher","first-page":"9277","DOI":"10.1109\/JSEN.2021.3050845","type":"journal-article","article-title":"Shape reconstruction with multiphase conductivity for electrical impedance tomography using improved convolutional neural network method","volume":"21","author":"Wu","year":"2021","journal-title":"IEEE Sens. J."},{"key":"prgbaead6cbib97","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/I2MTC48687.2022.9806671","type":"conference-proceedings","article-title":"Shape reconstruction for electrical impedance tomography with V2D-net deep convolutional neural network","author":"Wang","year":"2022"},{"key":"prgbaead6cbib98","doi-asserted-by":"publisher","first-page":"2367","DOI":"10.1109\/TMI.2018.2828303","type":"journal-article","article-title":"Deep D-bar: real-time electrical impedance tomography imaging with deep neural networks","volume":"37","author":"Hamilton","year":"2018","journal-title":"IEEE Trans. Med. Imaging"},{"key":"prgbaead6cbib99","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1007\/s42600-020-00079-3","type":"journal-article","article-title":"Electrical impedance tomography image reconstruction based on backprojection and extreme learning machines","volume":"36","author":"Gomes","year":"2020","journal-title":"Res. Biomed. Eng."},{"key":"prgbaead6cbib100","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-030-00889-5_1","type":"preprint","article-title":"UNet++: a nested U-net architecture for medical image segmentation","author":"Zhou","year":"2018"},{"key":"prgbaead6cbib101","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2023.3322501","type":"journal-article","article-title":"Calder\u00f3n\u2019s method-guided deep neural network for electrical impedance tomography","volume":"72","author":"Sun","year":"2023","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"prgbaead6cbib102","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2021.3092061","type":"journal-article","article-title":"RCRC: a deep neural network for dynamic image reconstruction of electrical impedance tomography","volume":"70","author":"Ren","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"prgbaead6cbib103","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/IST55454.2022.9827773","type":"conference-proceedings","article-title":"HIHU-net: a hyper-information hybrid u-net for image reconstruction with electrical impedance tomography","author":"Wang","year":"2022"},{"key":"prgbaead6cbib104","doi-asserted-by":"publisher","first-page":"mbe\u201320\u201304","DOI":"10.3934\/mbe.2023329","type":"journal-article","article-title":"An EIT image reconstruction method based on DenseNet with multi-scale convolution","volume":"20","author":"Yang","year":"2023","journal-title":"Math. Biosci. Eng."},{"key":"prgbaead6cbib105","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2023.3284936","type":"journal-article","article-title":"Intracerebral hemorrhage imaging based on hybrid deep learning with electrical impedance tomography","volume":"72","author":"Shi","year":"2023","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"prgbaead6cbib106","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1007\/978-1-4419-9863-7_411","type":"book","article-title":"Heuristic optimization","author":"Wang","year":"2013"},{"key":"prgbaead6cbib107","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1002\/9781119175391.ch21","type":"book","article-title":"Heuristic optimization techniques","author":"Lee","year":"2016","edition":"1st edn"},{"key":"prgbaead6cbib108","doi-asserted-by":"publisher","DOI":"10.1002\/9780470225868","type":"other","article-title":"Modern heuristic optimization techniques: theory and applications to power systems","author":"Kwang","year":"2007"},{"key":"prgbaead6cbib109","doi-asserted-by":"publisher","first-page":"4237","DOI":"10.1007\/s10462-020-09952-0","type":"journal-article","article-title":"Metaheuristics: a comprehensive overview and classification along with bibliometric analysis","volume":"54","author":"Ezugwu","year":"2021","journal-title":"Artif. Intell. Rev."},{"key":"prgbaead6cbib110","doi-asserted-by":"publisher","DOI":"10.1016\/j.engappai.2022.105721","type":"journal-article","article-title":"Review on optimization techniques and role of artificial intelligence in home energy management systems","volume":"119","author":"Nutakki","year":"2023","journal-title":"Eng. Appl. Artif. Intell."},{"key":"prgbaead6cbib111","article-title":"RBF neural network image reconstruction for electrical impedance tomography","author":"Wang","year":"2004","type":"conference-proceedings"},{"key":"prgbaead6cbib112","doi-asserted-by":"crossref","DOI":"10.1109\/ICMLC.2009.5212387","type":"conference-proceedings","article-title":"Electrical impedance tomography based on BP neural network and improved PSO","author":"Wang","year":"2009"},{"key":"prgbaead6cbib113","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TMAG.2015.2488901","type":"journal-article","article-title":"Nonlinear electrical impedance tomography reconstruction using artificial neural networks and particle swarm optimization","volume":"52","author":"Martin","year":"2016","journal-title":"IEEE Trans. Magn."},{"key":"prgbaead6cbib114","doi-asserted-by":"publisher","first-page":"17","DOI":"10.3390\/s23177645","type":"journal-article","article-title":"Electrical impedance tomography of industrial two-phase flow based on radial basis function neural network optimized by the artificial bee colony algorithm","volume":"23","author":"Zhu","year":"2023","journal-title":"Sensors"},{"key":"prgbaead6cbib115","article-title":"COMSOL Multiphysics\u00ae Software\u2014understand, predict, and optimize","author":"COMSOL","type":"web-resource"},{"key":"prgbaead6cbib116","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2021.3124830","type":"journal-article","article-title":"Conductivity prediction and image reconstruction of complex-valued multi-frequency electrical capacitance tomography based on deep neural network","volume":"71","author":"Zhu","year":"2022","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"prgbaead6cbib117","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2022.3147877","type":"journal-article","article-title":"High-fidelity shape reconstruction for electrical impedance tomography of multi-phase conductivity via deep discrete representation","volume":"71","author":"Zhan","year":"2022","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"prgbaead6cbib118","doi-asserted-by":"publisher","first-page":"1636","DOI":"10.7150\/thno.22233","type":"journal-article","article-title":"Non-invasive electrical impedance tomography for multi-scale detection of liver fat content","volume":"8","author":"Luo","year":"2018","journal-title":"Theranostics"},{"key":"prgbaead6cbib119","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1016\/j.softx.2018.09.005","type":"journal-article","article-title":"pyEIT: a python based framework for electrical impedance tomography","volume":"7","author":"Liu","year":"2018","journal-title":"SoftwareX"},{"key":"prgbaead6cbib120","doi-asserted-by":"publisher","first-page":"48","DOI":"10.5120\/7460-0526","type":"journal-article","article-title":"Electrical impedance tomography using EIDORS in a closed phantom","volume":"48","author":"Sarode","year":"2012","journal-title":"Int. J. Comput. Appl."},{"key":"prgbaead6cbib121","type":"book","article-title":"EIT Image interpretation","author":"Zhao","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib122","article-title":"\u00c9valuation de la vidange gastrique par tomographie d\u2019imp\u00e9dance \u00e9lectrique","author":"Trudelle","year":"1995","type":"web-resource"},{"key":"prgbaead6cbib123","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1186\/s12938-019-0701-y","type":"journal-article","article-title":"Integrated EIT system for functional lung ventilation imaging","volume":"18","author":"Jang","year":"2019","journal-title":"Biomed. Eng. OnLine"},{"key":"prgbaead6cbib124","article-title":"EIDORS stomach tutorial","author":"Adler","year":"2017","type":"web-resource"},{"key":"prgbaead6cbib125","doi-asserted-by":"publisher","first-page":"2494","DOI":"10.1109\/TBME.2017.2728323","type":"journal-article","article-title":"Electrical impedance tomography: tissue properties to image measures","volume":"64","author":"Adler","year":"2017","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"prgbaead6cbib126","type":"book","article-title":"Electromagnetic properties of tissues","author":"Rosalind","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib127","author":"Ramakrihna","year":"2015","type":"book"},{"key":"prgbaead6cbib128","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1097\/HP.0b013e3181f06c86","type":"journal-article","article-title":"Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz TO 100 kHz)","volume":"99","author":"On N.-i.r. Protection","year":"2010","journal-title":"Health Phys."},{"key":"prgbaead6cbib129","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1097\/HP.0000000000001261","type":"journal-article","article-title":"Gaps in knowledge relevant to the \u2018guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz\u2013100 kHz),\u2019","volume":"118","author":"The International Commission on Non-Ionizing Radiation Protection","year":"2020","journal-title":"Health Phys."},{"key":"prgbaead6cbib130","first-page":"pp 1","type":"journal-article","article-title":"C95.1-2019\u2014IEEE standard for safety levels with respect to human exposure to electric, magnetic, and electromagnetic fields, 0 Hz to 300 GHz | IEEE Standard | IEEE Xplore","author":"Institute of Electrical and Electronic Engineers","year":"2019"},{"key":"prgbaead6cbib131","first-page":"486","type":"journal-article","article-title":"Human body impedance and threshold currents for perception and pain for contact hazard analysis in the VLF-MF band | IEEE Journals & Magazine | IEEE Xplore","volume":"BME-33","author":"Chatterjee","year":"1986"},{"key":"prgbaead6cbib132","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1097\/HP.0000000000001210","type":"journal-article","article-title":"GUIDELINES FOR LIMITING EXPOSURE TO ELECTROMAGNETIC FIELDS (100 kHz to 300 GHz)","volume":"118","author":"ICNIRP","year":"2020","journal-title":"Health Phys."},{"key":"prgbaead6cbib133","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1109\/TEMC.2024.3483168","type":"journal-article","article-title":"Estimating the perception threshold of electrostimulation and heating for radiofrequency contact current","volume":"67","author":"Kodera","year":"2025","journal-title":"IEEE Trans. Electromagn. Compat"},{"key":"prgbaead6cbib134","article-title":"IEC 60601-1. Medical electrical equipment\u2014part 1: general requirements for basic safety and essential performance","author":"International Electrotechnical Commission","year":"2015","type":"web-resource"},{"key":"prgbaead6cbib135","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/5164970","type":"journal-article","article-title":"Modern diagnostic imaging technique applications and risk factors in the medical field: a review","volume":"2022","author":"Hussain","year":"2022","journal-title":"BioMed Res. Int."},{"key":"prgbaead6cbib136","first-page":"37","type":"journal-article","article-title":"A comparative study of medical imaging techniques","volume":"4","author":"Kasban","year":"2015"},{"key":"prgbaead6cbib137","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1097\/00001648-199007000-00013","type":"journal-article","article-title":"Hormonal effects of ultrasound","volume":"1","author":"Bromberg","year":"1990","journal-title":"Epidemiol. Camb. Mass"},{"key":"prgbaead6cbib138","doi-asserted-by":"publisher","first-page":"d947","DOI":"10.1136\/bmj.d947","type":"journal-article","article-title":"The risks of radiation exposure related to diagnostic imaging and how to minimise them","volume":"342","author":"Davies","year":"2011","journal-title":"BMJ"},{"key":"prgbaead6cbib139","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.ijdsr.2015.11.003","type":"journal-article","article-title":"Role of bioimpedance in cancer detection: a brief review","volume":"3","author":"Sarode","year":"2016","journal-title":"Int. J. Dent. Sci. Res."},{"key":"prgbaead6cbib140","first-page":"p 92","type":"book","article-title":"Dielectric properties of cancerous tissue","author":"Barnes","year":"2007","edition":"3rd edn"},{"key":"prgbaead6cbib141","doi-asserted-by":"publisher","first-page":"1600","DOI":"10.1016\/j.juro.2009.06.007","type":"journal-article","article-title":"Electrical properties of prostatic tissues: i. Single frequency admittivity properties","volume":"182","author":"Halter","year":"2009","journal-title":"J. Urol"},{"key":"prgbaead6cbib142","doi-asserted-by":"publisher","first-page":"1759","DOI":"10.1002\/pros.21393","type":"journal-article","article-title":"Passive bioelectrical properties for assessing high- and low-grade prostate adenocarcinoma","volume":"71","author":"Halter","year":"2011","journal-title":"The Prostate"},{"key":"prgbaead6cbib143","doi-asserted-by":"publisher","first-page":"1278","DOI":"10.1088\/1361-6579\/aa68ce","type":"journal-article","article-title":"Detecting colorectal cancer using electrical impedance spectroscopy: an ex vivo feasibility study","volume":"38","author":"Pathiraja","year":"2017","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib144","doi-asserted-by":"publisher","first-page":"2703","DOI":"10.1200\/JCO.2005.06.155","type":"journal-article","article-title":"Electrical impedance scanning for the early detection of breast cancer in young women: preliminary results of a multicenter prospective clinical trial","volume":"23","author":"Stojadinovic","year":"2005","journal-title":"J. Clin. Oncol. Off. J. Am. Soc. Clin. Oncol."},{"key":"prgbaead6cbib145","doi-asserted-by":"publisher","DOI":"10.1155\/2012\/470101","type":"journal-article","article-title":"Bladder cancer detection using electrical impedance technique (Tabriz Mark 1)","volume":"2012","author":"Keshtkar","year":"2012","journal-title":"Pathol. Res. Int."},{"key":"prgbaead6cbib146","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1186\/s12967-020-02395-9","type":"journal-article","article-title":"The clinical application of electrical impedance technology in the detection of malignant neoplasms: a systematic review","volume":"18","author":"Pathiraja","year":"2020","journal-title":"J. Transl. Med."},{"key":"prgbaead6cbib147","doi-asserted-by":"publisher","first-page":"4681","DOI":"10.1038\/s41598-019-41124-1","type":"journal-article","article-title":"Breast cancer cells exhibits specific dielectric signature in vitro using the open-ended coaxial probe technique from 200 MHz to 13.6 GHz","volume":"9","author":"Hussein","year":"2019","journal-title":"Sci. Rep."},{"key":"prgbaead6cbib148","doi-asserted-by":"publisher","DOI":"10.12659\/MSM.947531","type":"journal-article","article-title":"Real-time differentiation between benign and malignant breast tumors and other tissues using dielectric properties","volume":"31","author":"Chen","year":"2025","journal-title":"Med. Sci. Monit. Int. Med. J. Exp. Clin. Res."},{"key":"prgbaead6cbib149","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1007\/s13246-024-01490-1","type":"journal-article","article-title":"Application of dielectric properties for identification of normal and malignant gastrointestinal tumors and lymph nodes ex vivo","volume":"48","author":"Rao","year":"2025","journal-title":"Phys. Eng. Sci. Med."},{"key":"prgbaead6cbib150","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1088\/0967-3334\/31\/7\/009","type":"journal-article","article-title":"Electrical impedance characterization of normal and cancerous human hepatic tissue","volume":"31","author":"Laufer","year":"2010","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib151","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.12122\/j.issn.1673-4254.2019.11.15","type":"journal-article","article-title":"\u57fa\u4e8e\u5f00\u7aef\u540c\u8f74\u63a2\u5934\u6280\u672f\u7684\u80ba\u764c\u8f6c\u79fb\u548c\u975e\u8f6c\u79fb\u6dcb\u5df4\u7ed3\u4ecb\u7535\u7279 \u6027","volume":"39","author":"Sun","year":"2019","journal-title":"J. South. Med. Univ."},{"key":"prgbaead6cbib152","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1109\/TBME.2025.3581465","type":"journal-article","article-title":"In vivo classification of oral lesions using electrical impedance spectroscopy","volume":"73","author":"Lloyd","year":"2026","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"prgbaead6cbib153","doi-asserted-by":"publisher","first-page":"1580","DOI":"10.1016\/j.juro.2007.11.043","type":"journal-article","article-title":"Electrical impedance spectroscopy of benign and malignant prostatic tissues","volume":"179","author":"Halter","year":"2008","journal-title":"J. Urol"},{"key":"prgbaead6cbib154","doi-asserted-by":"publisher","author":"Gabriel","year":"1996","DOI":"10.21236\/ADA303903","type":"book"},{"key":"prgbaead6cbib155","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2023.1121599","type":"journal-article","article-title":"Discrimination between human normal renal tissue and renal cell carcinoma by dielectric properties using in-vitro BIA","volume":"14","author":"Wang","year":"2023","journal-title":"Front. Physiol."},{"key":"prgbaead6cbib156","doi-asserted-by":"publisher","DOI":"10.1016\/j.xjidi.2021.100075","type":"journal-article","article-title":"Electrical characterization of basal cell carcinoma using a handheld electrical impedance dermography device","volume":"2","author":"Luo","year":"2022","journal-title":"JID Innov."},{"key":"prgbaead6cbib157","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1002\/mp.14562","type":"journal-article","article-title":"Differences in the dielectric properties of various benign and malignant thyroid nodules","volume":"48","author":"Huang","year":"2021","journal-title":"Med. Phys."},{"key":"prgbaead6cbib158","type":"book","article-title":"EIT for imaging of cancer","author":"Halter","year":"2022","edition":"2nd edn"},{"key":"prgbaead6cbib159","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/SENSORS56945.2023.10325283","type":"journal-article","article-title":"Biosensor based on electrical impedance tomography for 3D cancer cell culture imaging","volume":"1","author":"Claudel","year":"2023","journal-title":"2023 IEEE Sens."},{"key":"prgbaead6cbib160","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2022.e12458","type":"journal-article","article-title":"Emerging trends and hot spots on electrical impedance tomography extrapulmonary applications","volume":"8","author":"Xu","year":"2022","journal-title":"Heliyon"},{"key":"prgbaead6cbib161","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2025.117986","type":"journal-article","article-title":"Feasibility analysis of EIT-guided lung tumor tracking with prior information for robotic arm-assisted radiotherapy","volume":"256","author":"Yu","year":"2025","journal-title":"Measurement"},{"key":"prgbaead6cbib162","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.726652","type":"journal-article","article-title":"The research progress of electrical impedance tomography for lung monitoring","volume":"9","author":"Shi","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"prgbaead6cbib163","doi-asserted-by":"publisher","first-page":"5595","DOI":"10.7314\/apjcp.2015.16.14.5595","type":"journal-article","article-title":"Electrical impedance tomography as a primary screening technique for breast cancer detection","volume":"16","author":"Akhtari-Zavare","year":"2015","journal-title":"Asian Pac. J. Cancer Prev. APJCP"},{"key":"prgbaead6cbib164","doi-asserted-by":"publisher","first-page":"9","DOI":"10.21037\/gs-21-348","type":"journal-article","article-title":"Diagnostic accuracy and prognostic value of three-dimensional electrical impedance tomography imaging in patients with breast cancer","volume":"10","author":"Xu","year":"2021","journal-title":"Gland Surg."},{"key":"prgbaead6cbib165","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-05116-8","type":"journal-article","article-title":"Deep learning-based electrical impedance spectroscopy analysis for malignant and potentially malignant oral disorder detection","volume":"15","author":"Lin","year":"2025","journal-title":"Sci. Rep."},{"key":"prgbaead6cbib166","doi-asserted-by":"publisher","first-page":"1933","DOI":"10.3390\/electronics10161933","type":"journal-article","article-title":"Performance evaluation of multiple electrodes based electrical impedance spectroscopic probe for screening of cervical intraepithelial neoplasia","volume":"10","author":"Zhang","year":"2021","journal-title":"Electronics"},{"key":"prgbaead6cbib167","doi-asserted-by":"publisher","DOI":"10.1118\/1.4803498","type":"journal-article","article-title":"Transrectal electrical impedance tomography of the prostate: spatially coregistered pathological findings for prostate cancer detection","volume":"40","author":"Wan","year":"2013","journal-title":"Med. Phys."},{"key":"prgbaead6cbib168","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.det.2017.06.009","type":"journal-article","article-title":"Electrical impedance spectroscopy in skin cancer diagnosis","volume":"35","author":"Braun","year":"2017","journal-title":"Dermatol. Clin."},{"key":"prgbaead6cbib169","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/S1350-4533(02)00194-7","type":"journal-article","article-title":"A review of electrical impedance techniques for breast cancer detection","volume":"25","author":"Zou","year":"2003","journal-title":"Med. Eng. Phys."},{"key":"prgbaead6cbib170","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1109\/TMI.2014.2342719","type":"journal-article","article-title":"Real-time electrical impedance variations in women with and without breast cancer","volume":"34","author":"Halter","year":"2015","journal-title":"IEEE Trans. Med. Imaging"},{"key":"prgbaead6cbib171","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/8565490","type":"journal-article","article-title":"The accuracy of electrical impedance tomography for breast cancer detection: a systematic review and meta-analysis","volume":"2022","author":"Rezanejad Gatabi","year":"2022","journal-title":"Breast J."},{"key":"prgbaead6cbib172","doi-asserted-by":"publisher","first-page":"63","DOI":"10.2478\/joeb-2021-0008","type":"journal-article","article-title":"Comparison of electrical impedance tomography and ultrasonography for determination of solid and cystic lesion resembling breast tumor embedded in chicken phantom","volume":"12","author":"Choridah","year":"2021","journal-title":"J. Electr. Bioimpedance"},{"key":"prgbaead6cbib173","doi-asserted-by":"publisher","DOI":"10.1063\/5.0041423","type":"journal-article","article-title":"A convolutional neural network algorithm for breast tumor detection with magnetic detection electrical impedance tomography","volume":"92","author":"Chen","year":"2021","journal-title":"Rev. Sci. Instrum."},{"key":"prgbaead6cbib174","doi-asserted-by":"publisher","first-page":"99","DOI":"10.2478\/joeb-2024-0011","type":"journal-article","article-title":"Breast cancer recognition by electrical impedance tomography implemented with Gaussian relaxation-time distribution (EIT\u2013GRTD)","volume":"15","author":"Setyawan","year":"2024","journal-title":"J. Electr. Bioimpedance"},{"key":"prgbaead6cbib175","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ad5db1","type":"journal-article","article-title":"Detection of invasive ductal carcinoma in quadrant breast areas by electrical impedance tomography implemented with gaussian relaxation-time distribution (EIT-GRTD)","volume":"10","author":"Setyawan","year":"2024","journal-title":"Biomed. Phys. Eng. Express"},{"key":"prgbaead6cbib176","doi-asserted-by":"publisher","first-page":"6370","DOI":"10.3390\/s24196370","type":"journal-article","article-title":"Modular and portable system design for 3D imaging of breast tumors using electrical impedance tomography","volume":"24","author":"G\u00f3mez Cort\u00e9s","year":"2024","journal-title":"Sensors"},{"key":"prgbaead6cbib177","doi-asserted-by":"publisher","DOI":"10.1016\/j.mex.2024.103087","type":"journal-article","article-title":"Multifrequency electrical impedance tomography (Mf-EIT) for the detection of breast cancer phantom anomalies","volume":"14","author":"Ariwanto","year":"2024","journal-title":"MethodsX"},{"key":"prgbaead6cbib178","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ae7117","type":"journal-article","article-title":"Comparative study of time- and frequency-difference electrical impedance tomography for breast cancer detection","volume":"12","author":"Marcos","year":"2026","journal-title":"Biomed. Phys. Eng. Express"},{"key":"prgbaead6cbib179","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1088\/0967-3334\/21\/1\/313","type":"journal-article","article-title":"Multifrequency electrical impedance imaging: preliminary in vivo experience in breast","volume":"21","author":"Osterman","year":"2000","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib180","doi-asserted-by":"publisher","first-page":"2229","DOI":"10.3233\/BME-141035","type":"journal-article","article-title":"Classification of normal and cancerous lung tissues by electrical impendence tomography","volume":"24","author":"Gao","year":"2014","journal-title":"Biomed. Mater. Eng."},{"key":"prgbaead6cbib181","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1088\/0967-3334\/23\/1\/304","type":"journal-article","article-title":"Preliminary static EIT images of the thorax in health and disease","volume":"23","author":"Cherepenin","year":"2001","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib182","doi-asserted-by":"publisher","first-page":"3049","DOI":"10.1109\/JSEN.2019.2892179","type":"journal-article","article-title":"An improved tikhonov regularization method for lung cancer monitoring using electrical impedance tomography","volume":"19","author":"Sun","year":"2019","journal-title":"IEEE Sens. J."},{"key":"prgbaead6cbib183","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.900110","type":"journal-article","article-title":"Electrical impedance analysis for lung cancer: a prospective, multicenter, blind validation study","volume":"12","author":"Yang","year":"2022","journal-title":"Front. Oncol."},{"key":"prgbaead6cbib184","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/EMBC40787.2023.10340136","type":"conference-proceedings","article-title":"Global and regional lung function assessment using portable electrical impedance tomography (EIT) system: clinical study","author":"Zouari","year":"2023"},{"key":"prgbaead6cbib185","doi-asserted-by":"publisher","first-page":"41989","DOI":"10.1109\/JSEN.2024.3483558","type":"journal-article","article-title":"Electrical impedance tomography based closed-loop tumor treating fields in dynamic lung tumors","volume":"24","author":"Zhang","year":"2024","journal-title":"IEEE Sens. J."},{"key":"prgbaead6cbib186","doi-asserted-by":"publisher","first-page":"951","DOI":"10.3390\/jpm11100951","type":"journal-article","article-title":"Emerging minimally invasive technologies for the detection of skin cancer","volume":"11","author":"Jung","year":"2021","journal-title":"J. Pers. Med."},{"key":"prgbaead6cbib187","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1111\/jocd.14547","type":"journal-article","article-title":"Non-invasive diagnostic techniques in pigmentary skin disorders and skin cancer","volume":"21","author":"Pathania","year":"2022","journal-title":"J. Cosmet. Dermatol"},{"key":"prgbaead6cbib188","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3390\/dermato2020004","type":"journal-article","article-title":"Electrical impedance spectroscopy improves skin cancer detection and reduces the number of biopsies","volume":"2","author":"Liebich","year":"2022","journal-title":"Dermato"},{"key":"prgbaead6cbib189","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1097\/CCO.0000000000000611","type":"journal-article","article-title":"Use of noninvasive imaging in the management of skin cancer","volume":"32","author":"Giuffrida","year":"2020","journal-title":"Curr. Opin. Oncol."},{"key":"prgbaead6cbib190","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1002\/bem.22396","type":"journal-article","article-title":"Adjunctive diagnostic methods for skin cancer detection: a review of electrical impedance-based techniques","volume":"43","author":"Anushree","year":"2022","journal-title":"Bioelectromagnetics"},{"key":"prgbaead6cbib191","doi-asserted-by":"publisher","first-page":"S17","DOI":"10.1088\/0967-3334\/31\/8\/S02","type":"journal-article","article-title":"Sensitivity study of an ultrasound coupled transrectal electrical impedance tomography system for prostate imaging","volume":"31","author":"Wan","year":"2010","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib192","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1007\/978-3-031-03873-0_7","type":"book","article-title":"Magnetic resonance electrical impedance tomography","author":"Sajib","year":"2022"},{"key":"prgbaead6cbib193","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1088\/0967-3334\/35\/4\/567","type":"journal-article","article-title":"A feasibility study of magnetic resonance electrical impedance tomography for prostate cancer detection","volume":"35","author":"Liu","year":"2014","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib194","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/aabf22","type":"journal-article","article-title":"Fused-data transrectal EIT for prostate cancer imaging","volume":"39","author":"Murphy","year":"2018","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib195","doi-asserted-by":"publisher","first-page":"3367","DOI":"10.1109\/TMI.2020.2992453","type":"journal-article","article-title":"Phantom studies of fused-data TREIT using only biopsy-probe electrodes","volume":"39","author":"Murphy","year":"2020","journal-title":"IEEE Trans. Med. Imaging"},{"key":"prgbaead6cbib196","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1109\/TBCAS.2020.2994297","type":"journal-article","article-title":"A 1 MHz miniaturized electrical impedance tomography system for prostate imaging","volume":"14","author":"Rao","year":"2020","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"prgbaead6cbib197","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.698038","type":"journal-article","article-title":"Electrical impedance tomography for robot-aided internal radiation therapy","volume":"9","author":"Tan","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"prgbaead6cbib198","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/EMBC40787.2023.10340037","type":"conference-proceedings","article-title":"Towards intraoperative surgical margin assessment: validation of an electrical impedance-based probe with ex vivo bovine tissue","volume":"vol 2023","author":"Doussan","year":"2023"},{"key":"prgbaead6cbib199","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1109\/EExPolytech.2018.8564401","type":"conference-proceedings","article-title":"Bioimpedance spectroscopy for characterization of healthy and cancerous tissues","author":"Teixeira","year":"2018"},{"key":"prgbaead6cbib200","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/ac4a87","type":"journal-article","article-title":"Electrical impedance tomography: a potential tool for intraoperative imaging of the tongue base","volume":"43","author":"Brazey","year":"2022","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib201","doi-asserted-by":"publisher","first-page":"15146","DOI":"10.1109\/JSEN.2022.3184342","type":"journal-article","article-title":"An electrode array sensor for tongue cancer detection with bioelectrical impedance spectroscopic tomography","volume":"22","author":"Hu","year":"2022","journal-title":"IEEE Sens. J."},{"key":"prgbaead6cbib202","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/EMBC53108.2024.10781936","type":"conference-proceedings","article-title":"Depth sensing capabilities of an interoperative impedance sensing probe","volume":"vol 2024","author":"Lloyd","year":"2024"},{"key":"prgbaead6cbib203","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2026.3652751","type":"journal-article","article-title":"Electrical characterization of tongue tissue during electroporation: ex vivo and computational study","volume":"75","author":"Lopes","year":"2026","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"prgbaead6cbib204","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1088\/0967-3334\/33\/5\/849","type":"journal-article","article-title":"An electrical impedance tomography system for gynecological application GIT with a tiny electrode array","volume":"33","author":"Cherepenin","year":"2012","journal-title":"Physiol. Meas."},{"key":"prgbaead6cbib205","doi-asserted-by":"publisher","first-page":"67745","DOI":"10.1109\/ACCESS.2023.3292186","type":"journal-article","article-title":"Cervical intraepithelial neoplasia localization with frequency-difference electrical impedance tomography\u2014simulation and phantom study","volume":"11","author":"Ouypornkochagorn","year":"2023","journal-title":"IEEE Access"},{"key":"prgbaead6cbib206","doi-asserted-by":"publisher","first-page":"92087","DOI":"10.1109\/ACCESS.2024.3423653","type":"journal-article","article-title":"Frequency-difference electrical impedance imaging of cervical specimens","volume":"12","author":"Ouypornkochagorn","year":"2024","journal-title":"IEEE Access"}],"container-title":["Progress in Biomedical Engineering"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2516-1091\/aead6c","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2516-1091\/aead6c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2516-1091\/aead6c","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2516-1091\/aead6c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2516-1091\/aead6c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2516-1091\/aead6c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2516-1091\/aead6c\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2516-1091\/aead6c\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T06:15:24Z","timestamp":1793600124000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2516-1091\/aead6c"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11,2]]},"references-count":206,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,11,2]]},"published-print":{"date-parts":[[2026,12,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2516-1091\/aead6c","relation":{"has-review":[{"id-type":"doi","id":"10.1088\/2516-1091\/AEAD6C\/v2\/review2","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2516-1091\/AEAD6C\/v1\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2516-1091\/AEAD6C\/v1\/review2","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2516-1091\/AEAD6C\/v1\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2516-1091\/AEAD6C\/v2\/review1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2516-1091\/AEAD6C\/v3\/response1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2516-1091\/AEAD6C\/v2\/decision1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2516-1091\/AEAD6C\/v2\/response1","asserted-by":"object"},{"id-type":"doi","id":"10.1088\/2516-1091\/AEAD6C\/v3\/decision1","asserted-by":"object"}]},"ISSN":["2516-1091"],"issn-type":[{"value":"2516-1091","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,11,2]]},"assertion":[{"value":"Emerging horizons in cancer monitoring: electrical impedance tomography as a cost-effective noninvasive imaging and diagnostics system","name":"article_title","label":"Article Title"},{"value":"Progress in Biomedical Engineering","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2026 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2026-05-08","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-09-28","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2026-11-02","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}