{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T02:56:56Z","timestamp":1772333816303,"version":"3.50.1"},"reference-count":7,"publisher":"IOP Publishing","issue":"21","license":[{"start":{"date-parts":[[2011,5,4]],"date-time":"2011-05-04T00:00:00Z","timestamp":1304467200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/page\/copyright"},{"start":{"date-parts":[[2011,5,4]],"date-time":"2011-05-04T00:00:00Z","timestamp":1304467200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["J. Phys. D: Appl. Phys."],"published-print":{"date-parts":[[2011,6,1]]},"abstract":"<jats:p>Over the last ten years, signatures of high temperature ferromagnetism have been found in thin films and nanoparticles of various materials which are non-ferromagnetic in bulk, from semiconductors to superconductors. These studies often involve state-of-the-art magnetometers working close to the limits of their sensitivity, where magnetic contaminations and measurement artefacts become non-negligible. Because such spurious effects may be involved, the reliability of magnetometry techniques for the detection of ferromagnetism in these new magnetic nanomaterials has been questioned. In this paper, we present a detailed study on magnetic contamination arising from sample processing and handling, describing how it may occur and how it can be avoided or otherwise removed. We demonstrate that, when proper procedures are followed, extrinsic magnetic signals can be reproducibly kept below 5 \u00d7 10<jats:sup>\u22127<\/jats:sup>\u2009emu (5 \u00d7 10<jats:sup>\u221210<\/jats:sup>\u2009A\u2009m<jats:sup>2<\/jats:sup>). We also give an overview of the expected levels of contamination when such optimum conditions cannot be guaranteed and analyse the characteristics of the resulting magnetic behaviour, discussing which features may or may not be used as criteria to distinguish it from intrinsic ferromagnetism. Although the measurements were performed using superconducting quantum interference device magnetometers, most of what we describe can also be applied when using alternating-gradient force and vibrating-sample magnetometers.<\/jats:p>","DOI":"10.1088\/0022-3727\/44\/21\/215001","type":"journal-article","created":{"date-parts":[[2011,5,5]],"date-time":"2011-05-05T03:38:21Z","timestamp":1304566701000},"page":"215001","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":46,"title":["Practical limits for detection of ferromagnetism using highly sensitive magnetometry techniques"],"prefix":"10.1088","volume":"44","author":[{"given":"L M C","family":"Pereira","sequence":"first","affiliation":[]},{"given":"J P","family":"Ara\u00fajo","sequence":"additional","affiliation":[]},{"given":"M J","family":"Van Bael","sequence":"additional","affiliation":[]},{"given":"K","family":"Temst","sequence":"additional","affiliation":[]},{"given":"A","family":"Vantomme","sequence":"additional","affiliation":[]}],"member":"266","published-online":{"date-parts":[[2011,5,4]]},"reference":[{"key":"jphysd388466bib01","doi-asserted-by":"publisher","first-page":"252502","DOI":"10.1063\/1.2146057","volume":"87","year":"2005","journal-title":"Appl. Phys. Lett."},{"key":"jphysd388466bib02","doi-asserted-by":"publisher","first-page":"013925","DOI":"10.1063\/1.3060808","volume":"105","year":"2009","journal-title":"J. Appl. Phys."},{"key":"jphysd388466bib03","doi-asserted-by":"publisher","first-page":"3341","DOI":"10.1016\/j.jmmm.2008.07.008","volume":"320","year":"2008","journal-title":"J. Magn. Magn. Mater."},{"key":"jphysd388466bib04","doi-asserted-by":"publisher","first-page":"1380","DOI":"10.1063\/1.1137249","volume":"54","year":"1983","journal-title":"Rev. Sci. Instrum."},{"key":"jphysd388466bib05","doi-asserted-by":"publisher","first-page":"3357","DOI":"10.1063\/1.1144306","volume":"64","year":"1993","journal-title":"Rev. Sci. Instrum."},{"key":"jphysd388466bib06","doi-asserted-by":"publisher","first-page":"3201","DOI":"10.1063\/1.1147493","volume":"67","year":"1996","journal-title":"Rev. Sci. Instrum."},{"key":"jphysd388466bib07","doi-asserted-by":"publisher","first-page":"015106","DOI":"10.1063\/1.2149190","volume":"77","year":"2006","journal-title":"Rev. Sci. Instrum."}],"container-title":["Journal of Physics D: Applied Physics"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0022-3727\/44\/21\/215001","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0022-3727\/44\/21\/215001\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0022-3727\/44\/21\/215001\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0022-3727\/44\/21\/215001\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,7]],"date-time":"2023-02-07T18:01:45Z","timestamp":1675792905000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/0022-3727\/44\/21\/215001"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,5,4]]},"references-count":7,"journal-issue":{"issue":"21","published-online":{"date-parts":[[2011,5,4]]},"published-print":{"date-parts":[[2011,6,1]]}},"URL":"https:\/\/doi.org\/10.1088\/0022-3727\/44\/21\/215001","relation":{},"ISSN":["0022-3727","1361-6463"],"issn-type":[{"value":"0022-3727","type":"print"},{"value":"1361-6463","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,5,4]]},"assertion":[{"value":"Practical limits for detection of ferromagnetism using highly sensitive magnetometry techniques","name":"article_title","label":"Article Title"},{"value":"Journal of Physics D: Applied Physics","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"2011 IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2011-03-22","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2011-05-04","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}