{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T13:44:40Z","timestamp":1773495880668,"version":"3.50.1"},"reference-count":19,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2019,1,10]],"date-time":"2019-01-10T00:00:00Z","timestamp":1547078400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2019,1,10]],"date-time":"2019-01-10T00:00:00Z","timestamp":1547078400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2019,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    EasyPET is a new concept of a Positron Emission Tomography (PET) scanner using an innovative acquisition method based on two rotation axes for the movement of detector pairs. Due to its simplicity, it is suitable for education purposes, to teach students about the PET technology and its basic concepts, from the radiation detecting and analogue pulse analysis to the coincidence sorting and image reconstruction. The concept allows achieving high and uniform position resolution over the whole field of view (FoV), by eliminating parallax errors due to the depth of interaction (DoI), which are typical of ring-based PET systems, so quality images are obtained even without state-of-the-art image reconstruction algorithms. The technology developed at the University of Aveiro with a patent-pending, is licensed to CAEN S.p.A, and included in the educational catalogue of the company. In this work, a simulation toolkit based in the Edugate platform was developed to simulate the EasyPET system. It can simulate all the physical aspects of the product, such us the scanning range, variable Field-of-View (FOV), scintillator energy resolution, coincidence time and energy window, among others. A simple image reconstruction algorithm based on Filtered-back-projection (FBP) is implemented. The toolkit allows a quick analysis in classroom of the simulation results. The platform was also used to study the new EasyPET 3D version, and a simulation of a NEMA NU 4-2008 IQ phantom was performed, demonstrating the capability of the platform not only for education purposes but also for research.\n                    <jats:bold>Patent<\/jats:bold>\n                    Universidade de Aveiro: PCT\/IB2016\/051487.\n                  <\/jats:p>","DOI":"10.1088\/2057-1976\/aae4d4","type":"journal-article","created":{"date-parts":[[2018,9,27]],"date-time":"2018-09-27T12:15:43Z","timestamp":1538050543000},"page":"025009","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["An EDUGATE simulation toolkit based on the educational easyPET"],"prefix":"10.1088","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7292-7735","authenticated-orcid":false,"given":"P M M","family":"Correia","sequence":"first","affiliation":[]},{"given":"J","family":"Menoita","sequence":"additional","affiliation":[]},{"given":"A L M","family":"Silva","sequence":"additional","affiliation":[]},{"given":"N","family":"Romanyshyn","sequence":"additional","affiliation":[]},{"given":"J F C A","family":"Veloso","sequence":"additional","affiliation":[]},{"given":"P M","family":"S\u00e1","sequence":"additional","affiliation":[]},{"given":"N","family":"Matela","sequence":"additional","affiliation":[]},{"given":"P","family":"Almeida","sequence":"additional","affiliation":[]}],"member":"266","published-online":{"date-parts":[[2019,1,10]]},"reference":[{"key":"bpexaae4d4bib1","doi-asserted-by":"publisher","first-page":"157","DOI":"10.2967\/jnmt.111.098632","type":"journal-article","volume":"40","author":"Yao","year":"2012","journal-title":"J. Nucl. Med. Technol."},{"key":"bpexaae4d4bib2","doi-asserted-by":"publisher","first-page":"6207","DOI":"10.1088\/1361-6560\/aa7171","type":"journal-article","volume":"62","author":"Kyme","year":"2017","journal-title":"Phys. Med. Biol."},{"key":"bpexaae4d4bib3","doi-asserted-by":"publisher","first-page":"2463","DOI":"10.1088\/0031-9155\/42\/12\/012","type":"journal-article","volume":"42","author":"Freifelder","year":"1997","journal-title":"Phys. Med. Biol."},{"key":"bpexaae4d4bib4","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1016\/j.nima.2016.05.004","type":"journal-article","volume":"845","author":"Arosio","year":"2017","journal-title":"Nuclear Instruments and Methods in Physics Research section A: Accelerators, Spectrometers, Detectors and Associated Equipment"},{"key":"bpexaae4d4bib5","doi-asserted-by":"publisher","author":"Arosio","year":"2016","DOI":"10.1109\/NSSMIC.2016.8069360","type":"conference-proceedings"},{"key":"bpexaae4d4bib6","author":"Veloso","year":"2016","type":"patent"},{"key":"bpexaae4d4bib7","type":"web-resource"},{"key":"bpexaae4d4bib8","doi-asserted-by":"publisher","first-page":"R287","DOI":"10.1088\/0031-9155\/53\/17\/R01","type":"journal-article","volume":"53","author":"Lewellen","year":"1997","journal-title":"Phys. Med. Biol."},{"key":"bpexaae4d4bib9","doi-asserted-by":"publisher","first-page":"6635","DOI":"10.1088\/0031-9155\/61\/18\/6635","type":"journal-article","volume":"61","author":"Uchida","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"bpexaae4d4bib10","doi-asserted-by":"publisher","first-page":"3673","DOI":"10.1088\/0031-9155\/60\/9\/3673","type":"journal-article","volume":"60","author":"Cabello","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"bpexaae4d4bib11","doi-asserted-by":"publisher","DOI":"10.1117\/12.2063935","type":"conference-proceedings","volume":"9286","author":"Correia","year":"2014"},{"key":"bpexaae4d4bib12","doi-asserted-by":"publisher","first-page":"1516","DOI":"10.1109\/TNS.2003.817974","type":"journal-article","volume":"50","author":"Santin","year":"2003","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"bpexaae4d4bib13","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/S0168-9002(03)01368-8","type":"journal-article","volume":"506","author":"Agostinelli","year":"2003","journal-title":"Nuclear Instruments and Methods in Physics Research section A: Accelerators, Spectrometers, Detectors and Associated Equipment"},{"key":"bpexaae4d4bib14","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.zemedi.2012.07.005","type":"journal-article","volume":"23","author":"Pietrzyk","year":"2013","journal-title":"Zeitschrift f\u00fcr Medizinische Physik"},{"key":"bpexaae4d4bib15","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/S0168-9002(97)00048-X","type":"journal-article","volume":"389","author":"Brun","year":"1997","journal-title":"Nuclear Instruments and Methods in Physics Research section A: Accelerators, Spectrometers, Detectors and Associated Equipment"},{"key":"bpexaae4d4bib16","doi-asserted-by":"publisher","first-page":"e453","DOI":"10.7717\/peerj.453","type":"journal-article","volume":"2","author":"(the scikit-image contributors)","year":"2014","journal-title":"PeerJ"},{"key":"bpexaae4d4bib17","year":"2008","type":"other"},{"key":"bpexaae4d4bib18","author":"Sa","year":"2017","type":"other"},{"key":"bpexaae4d4bib19","author":"Correia","year":"2017","type":"other"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4","content-type":"text\/html","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T12:12:53Z","timestamp":1773490373000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/aae4d4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1,10]]},"references-count":19,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2019,1,10]]},"published-print":{"date-parts":[[2019,2,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/aae4d4","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,1,10]]},"assertion":[{"value":"An EDUGATE simulation toolkit based on the educational easyPET","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2019 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2018-07-02","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2018-09-27","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2019-01-10","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}