{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T15:16:57Z","timestamp":1765034217708,"version":"3.46.0"},"reference-count":19,"publisher":"IOP Publishing","issue":"5","license":[{"start":{"date-parts":[[2021,8,24]],"date-time":"2021-08-24T00:00:00Z","timestamp":1629763200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/publishingsupport.iopscience.iop.org\/iop-standard\/v1"},{"start":{"date-parts":[[2021,8,24]],"date-time":"2021-08-24T00:00:00Z","timestamp":1629763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2021,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The treatment of obesity based only on lifestyle changes has been shown ineffectiveness in a long-term period. The development of more definitive and non-invasive therapies has been the subject of study. In this paper, a magnetically driven ingestible capsule with the capacity to inflate a gastric balloon is devised, simulated, and fabricated. The balloon is inflated to a volume of 150 ml using an acid-base reaction between citric acid and potassium bicarbonate. Finite element method simulations were performed to study the interaction between the permanent external magnet and the ingestible capsule and confirm the magnetic activation mechanism. A fabrication process was proposed to manufacture a polydimethylsiloxane (PDMS) balloon in a simple, functional, and reproducible way. The two layers and 1:8 ratio balloons are the most cost-effective without compromising their mechanical properties. The capsule body parts manufactured by a three-dimensional (3D) printing process - Digital Light Processing (DLP) showed high accuracy and excellent resolution. This study demonstrated that the proposed ingestible capsule would successfully inflate the gastric balloon to treat obesity.<\/jats:p>","DOI":"10.1088\/2057-1976\/ac1d88","type":"journal-article","created":{"date-parts":[[2021,8,13]],"date-time":"2021-08-13T18:23:16Z","timestamp":1628878996000},"page":"055024","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Design, simulation, and fabrication of an ingestible capsule with gastric balloon for obesity treatment"],"prefix":"10.1088","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9725-2623","authenticated-orcid":false,"given":"R B","family":"Freitas","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2527-5006","authenticated-orcid":false,"given":"J A","family":"Rodrigues","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1121-6793","authenticated-orcid":false,"given":"H","family":"Puga","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5991-1069","authenticated-orcid":false,"given":"J H","family":"Correia","sequence":"additional","affiliation":[]}],"member":"266","published-online":{"date-parts":[[2021,8,24]]},"reference":[{"key":"bpexac1d88bib1","doi-asserted-by":"publisher","first-page":"2509","DOI":"10.1016\/j.sjbs.2020.03.015","type":"journal-article","article-title":"Impact of weight loss predictors in severe-morbid obesity patients in the Saudi population","volume":"27","author":"Al-Nbaheen","year":"2020","journal-title":"Saudi J. Biol. Sci."},{"key":"bpexac1d88bib2","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.medengphy.2006.03.009","type":"journal-article","article-title":"Implantable neural electrical stimulator for external control of gastrointestinal motility","volume":"29","author":"Jalilian","year":"2007","journal-title":"Med. Eng. Phys."},{"key":"bpexac1d88bib3","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.medengphy.2008.03.006","type":"journal-article","article-title":"In vivo quantification of subcutaneous and visceral adiposity by micro-computed tomography in a small animal model","volume":"31","author":"Luu","year":"2009","journal-title":"Med. Eng. Phys."},{"key":"bpexac1d88bib4","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.medengphy.2017.12.008","type":"journal-article","article-title":"Instantaneous VO2 from a wearable device","volume":"52","author":"Cook","year":"2018","journal-title":"Med. Eng. Phys."},{"key":"bpexac1d88bib5","doi-asserted-by":"publisher","first-page":"5495","DOI":"10.3748\/wjg.v22.i24.5495","type":"journal-article","article-title":"Current status of intragastric balloon for obesity treatment","volume":"22","author":"Kim","year":"2016","journal-title":"World J. Gastroenterol."},{"key":"bpexac1d88bib6","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1007\/s11695-007-9331-8","type":"journal-article","article-title":"Safety and effectiveness of the intragastric balloon for obesity. A meta-analysis","volume":"18","author":"Imaz","year":"2008","journal-title":"Obes. Surg."},{"key":"bpexac1d88bib7","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1016\/j.gie.2009.02.014","type":"journal-article","article-title":"The risks of GI endoscopy","volume":"69","author":"Lipp","year":"2009","journal-title":"Gastrointest. Endosc."},{"key":"bpexac1d88bib8","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.medengphy.2020.09.012","type":"journal-article","article-title":"Active delivery of multi-layer drug-loaded microneedle patches using magnetically driven capsule","volume":"85","author":"Lee","year":"2020","journal-title":"Med. Eng. Phys."},{"key":"bpexac1d88bib9","doi-asserted-by":"publisher","first-page":"045006","DOI":"10.1088\/2057-1976\/aab974","type":"journal-article","article-title":"Bone fracture monitoring using implanted antennas in the radius, tibia and phalange heterogeneous bone phantoms","volume":"4","author":"Symeonidis","year":"2018","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexac1d88bib10","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0148035","type":"journal-article","article-title":"Development and testing of a magnetically actuated capsule endoscopy for obesity treatment","volume":"11","author":"Do","year":"2016","journal-title":"PLoS One"},{"key":"bpexac1d88bib11","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1016\/j.soard.2015.10.074","type":"journal-article","article-title":"A history of intragastric balloons","volume":"12","author":"Gleysteen","year":"2016","journal-title":"Surg. Obes. Relat. Dis."},{"year":"2012","author":"Otilia","key":"bpexac1d88bib12","type":"book"},{"year":"2015","author":"Silva","key":"bpexac1d88bib13","type":"other"},{"edition":"1st ed.","year":"1991","author":"Jiles","key":"bpexac1d88bib14","type":"book"},{"year":"2009","author":"Pinho","key":"bpexac1d88bib15","type":"other"},{"key":"bpexac1d88bib16","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1586\/17434440.2015.1080120","type":"journal-article","article-title":"Magnetically driven medical devices: a review","volume":"12","author":"Sliker","year":"2015","journal-title":"Expert Rev. Med. Devices"},{"key":"bpexac1d88bib17","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2019.126711","type":"journal-article","article-title":"Stretchable, printable, and tunable PDMS-CaCl2 microcomposite for capacitive humidity sensors on textiles","volume":"297","author":"Komazaki","year":"2019","journal-title":"Sensors Actuators, B Chem."},{"key":"bpexac1d88bib18","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/s10544-005-6070-2","type":"journal-article","article-title":"Characterization of Polydimethylsiloxane (PDMS) Properties for biomedical micro\/nanosystems","volume":"7","author":"Mata","year":"2005","journal-title":"Biomed. Microdevices"},{"key":"bpexac1d88bib19","doi-asserted-by":"publisher","first-page":"1620","DOI":"10.1038\/s41467-018-03759-y","type":"journal-article","article-title":"Precisely printable and biocompatible silk fibroin bioink for digital light processing 3D printing","volume":"9","author":"Kim","year":"2018","journal-title":"Nat. Commun."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ac1d88","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ac1d88\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ac1d88","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ac1d88\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ac1d88\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ac1d88\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ac1d88\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ac1d88\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T15:14:48Z","timestamp":1765034088000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ac1d88"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,24]]},"references-count":19,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2021,8,24]]},"published-print":{"date-parts":[[2021,9,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ac1d88","relation":{},"ISSN":["2057-1976"],"issn-type":[{"type":"electronic","value":"2057-1976"}],"subject":[],"published":{"date-parts":[[2021,8,24]]},"assertion":[{"value":"Design, simulation, and fabrication of an ingestible capsule with gastric balloon for obesity treatment","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2021 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved.","name":"copyright_information","label":"Copyright Information"},{"value":"2021-05-12","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-08-13","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2021-08-24","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}