{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T08:17:29Z","timestamp":1777709849432,"version":"3.51.4"},"reference-count":56,"publisher":"IOP Publishing","issue":"2","license":[{"start":{"date-parts":[[2024,1,24]],"date-time":"2024-01-24T00:00:00Z","timestamp":1706054400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,1,24]],"date-time":"2024-01-24T00:00:00Z","timestamp":1706054400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2024,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Ureters are essential components of the urinary system and play a crucial role in the transportation of urine from the kidneys to the bladder. In the current study, a three-dimensional ureter is modelled. A series of peristaltic waves are made to travel on the ureter wall to analyse and measure parameter effects such as pressure, velocity, gradient pressure, and wall shear at different time steps. The flow dynamics in the ureters are thoroughly analysed using the commercially available ANSYS-CFX software. The maximum pressure is found in the triple wave at the ureteropelvic junction and maximum velocity is observed in the single and double wave motion due to the contraction produced by the peristalsis motion. The pressure gradient is maximum at the inlet of the ureter during the single bolus motion. The contraction produces a high jet of velocity due to neck formation and also helps in urine trapping in the form of a bolus, which leads to the formation of reverse flow. Due to the reduction in area, shear stress builds on the ureter wall. The high shear stress may rupture the junctions in the ureter.<\/jats:p>","DOI":"10.1088\/2057-1976\/ad1f02","type":"journal-article","created":{"date-parts":[[2024,1,16]],"date-time":"2024-01-16T22:23:40Z","timestamp":1705443820000},"page":"025011","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["CFD investigation of multiple peristaltic waves in a 3D unobstructed ureter"],"prefix":"10.1088","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7010-7186","authenticated-orcid":false,"given":"Laxmikant G","family":"Keni","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2374-3854","authenticated-orcid":false,"given":"B","family":"Satish Shenoy","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9399-685X","authenticated-orcid":false,"given":"K N","family":"Chethan","sequence":"additional","affiliation":[]},{"given":"Padmaraj","family":"Hegde","sequence":"additional","affiliation":[]},{"given":"K","family":"Prakashini","sequence":"additional","affiliation":[]},{"given":"Masaaki","family":"Tamagawa","sequence":"additional","affiliation":[]},{"given":"Mohammad","family":"Zuber","sequence":"additional","affiliation":[]}],"member":"266","published-online":{"date-parts":[[2024,1,24]]},"reference":[{"key":"bpexad1f02bib1","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1016\/j.mpsur.2016.04.001","article-title":"Anatomy of the lower urinary tract","volume":"34","author":"Mahadevan","year":"2016","journal-title":"Surg."},{"key":"bpexad1f02bib2","author":"Krstic","year":"2013"},{"key":"bpexad1f02bib3","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1038\/nrn2401","article-title":"The neural control of micturition","volume":"9","author":"Fowler","year":"2008","journal-title":"Nat. Rev. Neurosci."},{"key":"bpexad1f02bib4","doi-asserted-by":"publisher","DOI":"10.1142\/S1793524515500734","article-title":"Effect of melting heat transfer on peristalsis in the presence of thermal radiation and Joule heating","volume":"08","author":"Hayat","year":"2015","journal-title":"Int. J. Biomath."},{"key":"bpexad1f02bib5","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1002\/wsbm.1212","article-title":"Lower urinary tract development and disease","volume":"5","author":"Rasouly","year":"2013","journal-title":"Wiley Interdiscip. Rev. Syst. Biol. Med."},{"key":"bpexad1f02bib6","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1002\/aja.1001330302","article-title":"The ureteral lumen during peristalsis","volume":"133","author":"Woodburne","year":"1972","journal-title":"Am. J. Anat."},{"key":"bpexad1f02bib7","doi-asserted-by":"publisher","first-page":"52","DOI":"10.3390\/mca25030052","article-title":"Effects of convection on sisko fluid with peristalsis in an asymmetric channel","volume":"25","author":"Iqbal","year":"2020","journal-title":"Math. Comput. Appl."},{"key":"bpexad1f02bib8","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1155\/2013\/920276","article-title":"Convective heat transfer analysis on Prandtl fluid model with peristalsis","volume":"10","author":"Alsaedi","year":"2013","journal-title":"Appl. Bionics Biomech."},{"key":"bpexad1f02bib9","doi-asserted-by":"publisher","first-page":"2673","DOI":"10.3390\/math11122673","article-title":"Mathematical analysis of mixed convective peristaltic flow for chemically reactive casson nanofluid","volume":"11","author":"Yasmin","year":"2023","journal-title":"Mathematics"},{"key":"bpexad1f02bib10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2021\/2638647","article-title":"Convective mass\/heat analysis of an electroosmotic peristaltic flow of ionic liquid in a symmetric porous microchannel with soret and dufour","volume":"2021","author":"Yasmin","year":"2021","journal-title":"Math. Probl. Eng."},{"key":"bpexad1f02bib11","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s12043-014-0888-1","article-title":"Simultaneous effects of hall and convective conditions on peristaltic flow of couple-stress fluid in an inclined asymmetric channel","volume":"85","author":"Hayat","year":"2015","journal-title":"Pramana - J. Phys."},{"key":"bpexad1f02bib12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3390\/math8101710","article-title":"Engineering applications of peristaltic fluid flow with hall current, thermal deposition and convective conditions","volume":"8","author":"Yasmin","year":"2020","journal-title":"Mathematics"},{"key":"bpexad1f02bib13","first-page":"387","article-title":"The contraction of the ureter. I. Observations in normal human and dog ureters","volume":"32","author":"Kondo","year":"1970","journal-title":"Nagoya J. Med. Sci."},{"key":"bpexad1f02bib14","article-title":"Anatomy and physiology of the urinary tract: relation to host defense and microbial infection","volume":"3","author":"Hickling","year":"2015"},{"key":"bpexad1f02bib15","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.jtbi.2011.12.019","article-title":"A biomechanical simulation of ureteral flow during peristalsis using intraluminal morphometric data","volume":"298","author":"Vahidi","year":"2012","journal-title":"J. Theor. Biol."},{"key":"bpexad1f02bib16","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1007\/BF02951244","article-title":"The function of the ureter and renal pelvis","volume":"33","author":"Kill","year":"1958","journal-title":"Ir. J. Med. Sci."},{"key":"bpexad1f02bib17","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1088\/0031-9155\/32\/7\/002","article-title":"Dynamics of the upper urinary tract: i. Peristaltic flow through a distensible tube of limited length","volume":"32","author":"Griffiths","year":"1987","journal-title":"Phys. Med. Biol."},{"key":"bpexad1f02bib18","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1088\/0031-9155\/32\/7\/003","article-title":"Dynamics of the upper urinary tract: II. the effect of variations of peristaltic frequency and bladder pressure on pyeloureteral pressure\/flow relations","volume":"32","author":"Griffiths","year":"1987","journal-title":"Phys. Med. Biol."},{"key":"bpexad1f02bib19","first-page":"217","article-title":"Hydrodynamic model of ureteral function","author":"Weinberg","year":"1971"},{"key":"bpexad1f02bib20","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1001\/jama.1961.03040010017005","article-title":"Measurement of peristalsis of the ureter and its relation to drugs","volume":"175","author":"Weinberg","year":"1961","journal-title":"JAMA"},{"key":"bpexad1f02bib21","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1080\/10255842.2018.1516764","article-title":"A two way fully coupled fluid structure simulation of human ureter peristalsis","volume":"21","author":"Takaddus","year":"2018","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"bpexad1f02bib22","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1113\/jphysiol.2006.116855","article-title":"Pyeloureteric peristalsis: role of atypical smooth muscle cells and interstitial cells of Cajal-like cells as pacemakers","volume":"576","author":"Lang","year":"2006","journal-title":"J. Physiol."},{"key":"bpexad1f02bib23","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1115\/1.3168367","article-title":"Flow of urine through the ureter: a collapsible, muscular tube undergoing peristalsis","volume":"111","author":"Griffiths","year":"1989","journal-title":"J. Biomech. Eng."},{"key":"bpexad1f02bib24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/BF00296725","article-title":"Progress in urodynamic research on the upper urinary tract: implications for practical urology","volume":"24","author":"Kinn","year":"1996","journal-title":"Urol. Res."},{"key":"bpexad1f02bib25","doi-asserted-by":"crossref","DOI":"10.1142\/S0219519419500295","article-title":"Finite element analysis of urinary bladder wall thickness at different pressure condition","author":"Keni","year":"2019","journal-title":"J. Mech. Med. Biol."},{"key":"bpexad1f02bib26","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/0021-9290(70)90060-6","article-title":"Peristaltic transport in circular cylindrical tubes","volume":"3","author":"Li","year":"1970","journal-title":"J. Biomech."},{"key":"bpexad1f02bib27","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/0021-9290(70)90051-5","article-title":"A long wave approximation to peristaltic motion","volume":"3","author":"Zien","year":"1970","journal-title":"J. Biomech."},{"key":"bpexad1f02bib28","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1159\/000280227","article-title":"The ureteral pressure profile","volume":"33","author":"Bruijnes","year":"1978","journal-title":"Urol. Int."},{"key":"bpexad1f02bib29","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1080\/003655998750014620","article-title":"Ureteric profilometry: a study of the ureteric pressure profile in the normal and pathologic ureter","volume":"32","author":"Shafik","year":"1998","journal-title":"Scand. J. Urol. Nephrol."},{"key":"bpexad1f02bib30","doi-asserted-by":"publisher","first-page":"S223","DOI":"10.1016\/S0021-9290(07)70219-1","article-title":"Mathematical modeling of the ureteral peristaltic flow with fluid structure interaction","volume":"40","author":"Vahidi","year":"2007","journal-title":"J. Biomech."},{"key":"bpexad1f02bib31","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1002\/nau.1930130515","article-title":"Elastic wall properties and collagen content in the ureter: an experimental study in pigs","volume":"13","author":"Knudsen","year":"1994","journal-title":"Neurourol. Urodyn."},{"key":"bpexad1f02bib32","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1080\/10255842.2011.581237","article-title":"Multiaxial mechanical behaviour of the passive ureteral wall: experimental study and mathematical characterisation","volume":"15","author":"Sokolis","year":"2012","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"bpexad1f02bib33","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1615\/CritRevBiomedEng.2013009704","article-title":"Simulation of the upper urinary system","volume":"41","author":"Hosseini","year":"2013","journal-title":"Crit. Rev. Biomed. Eng."},{"key":"bpexad1f02bib34","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1115\/1.4034307","article-title":"Three-dimensional numerical simulations of peristaltic contractions in obstructed ureter flows","volume":"138","author":"Najafi","year":"2016","journal-title":"J. Biomech. Eng."},{"key":"bpexad1f02bib35","first-page":"1678","article-title":"Biaxial mechanical properties of human ureter under tension","volume":"11","author":"Rassoli","year":"2014","journal-title":"Urol. J."},{"key":"bpexad1f02bib36","first-page":"1","article-title":"Numerical simulations of peristalsis in unobstructed human ureters","volume":"3","author":"Takaddus","year":"2016","journal-title":"ASME Int. Mech. Eng. Congr. Expo. Proc."},{"key":"bpexad1f02bib37","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1080\/10255842.2017.1415333","article-title":"A two-dimensional numerical study of peristaltic contractions in obstructed ureter flows","volume":"21","author":"Najafi","year":"2018","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"bpexad1f02bib38","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/23311916.2022.2027080","article-title":"Static structural analysis of the effect of change in femoral head sizes used in Total Hip Arthroplasty using finite element method","volume":"9","author":"Bhawe","year":"2022","journal-title":"Cogent Eng."},{"key":"bpexad1f02bib39","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/23311916.2023.2222985","article-title":"Wear estimation at the contact surfaces of oval shaped hip implants using finite element analysis","volume":"10","author":"Shaikh","year":"2023","journal-title":"Cogent Eng."},{"key":"bpexad1f02bib40","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/2057-1976\/acb710","article-title":"Wear estimation of hip implants with varying chamfer geometry at the trunnion junction: a finite element analysis","volume":"9","author":"Gutmann","year":"2023","journal-title":"Biomed. Phys. Eng. Express"},{"key":"bpexad1f02bib41","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.cmpb.2020.105356","article-title":"Finite element analysis of immature teeth filled with MTA, Biodentine and Bioaggregate","volume":"190","author":"Eram","year":"2020","journal-title":"Comput. Methods Programs Biomed."},{"key":"bpexad1f02bib42","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1080\/02286203.2023.2212346","article-title":"Static, dynamic, and fatigue life investigation of a hip prosthesis for walking gait using finite element analysis","volume":"43","author":"Reginald","year":"2023","journal-title":"Int. J. Model. Simul."},{"key":"bpexad1f02bib43","first-page":"87","article-title":"Ureteral delivery and efflux","author":"Morales","year":"1971"},{"key":"bpexad1f02bib44","first-page":"399","article-title":"Modal activity of ureteral peristalsis","author":"William","year":"1971"},{"key":"bpexad1f02bib45","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1590\/S1677-55382008000400007","article-title":"The length of the male urethra","volume":"34","author":"Kohler","year":"2008","journal-title":"Int. braz j urol"},{"key":"bpexad1f02bib46","doi-asserted-by":"crossref","DOI":"10.1016\/j.cmpb.2021.106378","article-title":"Computational flow analysis of a single peristaltic wave propagation in the ureter","volume":"210","author":"Keni","year":"2021","journal-title":"Comput. Methods Programs Biomed."},{"key":"bpexad1f02bib47","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jnnfm.2016.08.001","article-title":"Peristaltic transport of solid particles suspended in a viscoplastic fluid: a numerical study","volume":"236","author":"Khabazi","year":"2016","journal-title":"J. Nonnewton. Fluid Mech."},{"key":"bpexad1f02bib48","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10697-005-0039-y","article-title":"Mathematical models in urinary system mechanics (review)","volume":"40","author":"Bykova","year":"2005","journal-title":"Fluid Dyn."},{"key":"bpexad1f02bib49","author":"Patankar","year":"2018"},{"key":"bpexad1f02bib50","article-title":"Peristaltic flow with application to ureteral","volume":"195s","author":"Jimenez","year":"2009"},{"key":"bpexad1f02bib51","first-page":"103","article-title":"Ureteral function. i. simultaneous monitoring of ureteral peristalsis","volume":"12","author":"Weinberg","year":"1974","journal-title":"Invest. Urol."},{"key":"bpexad1f02bib52","first-page":"1168","article-title":"A numerical simulation of peristaltic motion in the ureter using fluid structure interactions","author":"Vahidi","year":"2007"},{"key":"bpexad1f02bib53","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s13534-017-0053-0","article-title":"A computational model of ureteral peristalsis and an investigation into ureteral reflux","volume":"8","author":"Hosseini","year":"2018","journal-title":"Biomed. Eng. Lett."},{"key":"bpexad1f02bib54","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/S1350-4533(01)00078-9","article-title":"Peristaltic flow in a tapered channel: application to embryo transport within the uterine cavity","volume":"23","author":"Eytan","year":"2001","journal-title":"Med. Eng. Phys."},{"key":"bpexad1f02bib55","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1115\/1.4003316","article-title":"A mathematical simulation of the ureter: effects of the model parameters on ureteral pressure\/flow relations","volume":"133","author":"Vahidi","year":"2011","journal-title":"J. Biomech. Eng."},{"key":"bpexad1f02bib56","first-page":"55","article-title":"A nonlinear analysis of urine bolus peristaltic transport from the renal pelvis into the bladder using computational method of fluid-structure interaction","volume":"10","author":"Vahidi","year":"2010","journal-title":"Modares Mech. Eng."}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad1f02","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad1f02\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad1f02","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad1f02\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad1f02\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad1f02\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad1f02\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad1f02\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,25]],"date-time":"2024-01-25T13:02:42Z","timestamp":1706187762000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/ad1f02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,24]]},"references-count":56,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,1,24]]},"published-print":{"date-parts":[[2024,3,1]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/ad1f02","relation":{},"ISSN":["2057-1976"],"issn-type":[{"value":"2057-1976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,24]]},"assertion":[{"value":"CFD investigation of multiple peristaltic waves in a 3D unobstructed ureter","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2024 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2023-07-25","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-01-16","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2024-01-24","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}