{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,7]],"date-time":"2025-04-07T11:10:10Z","timestamp":1744024210266,"version":"3.40.3"},"reference-count":38,"publisher":"IOP Publishing","issue":"3","license":[{"start":{"date-parts":[[2025,4,7]],"date-time":"2025-04-07T00:00:00Z","timestamp":1743984000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,4,7]],"date-time":"2025-04-07T00:00:00Z","timestamp":1743984000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/iopscience.iop.org\/info\/page\/text-and-data-mining"}],"funder":[{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","award":["2018.137800.BD"],"award-info":[{"award-number":["2018.137800.BD"]}]}],"content-domain":{"domain":["iopscience.iop.org"],"crossmark-restriction":false},"short-container-title":["Biomed. Phys. Eng. Express"],"published-print":{"date-parts":[[2025,5,30]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:italic>Introduction:<\/jats:italic> Positron Emission Tomography (PET) imaging\u2019s diagnostic accuracy is dependent on the scanner design and image quality, which is affected by several factors including the coincidence timing window (CTW). NEMA NU 4-2008 procedures are commonly used to assess and compare PET systems performance, including dual rotation technologies like easyPET.3D, known for high-spatial resolution and reduced parallax contribution. <jats:italic>Aim:<\/jats:italic> This study aims to identify easyPET.3D\u2019s optimal performance based on NEMA standards. In addition, explores the impact of different CTWs on PET image quality by comparing simulated electronics capable of a 300 ps CTW with a 40 ns CTW. <jats:italic>Results:<\/jats:italic> When the data is filtered by a 40 ns CTW, a sub-millimetre resolution at the field-of-view (FoV) centre and a constant behaviour in the radial direction are achieved. The absolute sensitivity was 0.18% with a maximum value of 0.31%, for a 15 mm transverse FoV. The noise equivalent count rate peaked at 18 MBq with 249 cps. Recovery coefficients ranged from 17% to 90%, and spilled-over ratios were 0.32 (water) and 0.41 (air). <jats:italic>Conclusions:<\/jats:italic> A shorter 300 ps CTW primarily impacted PET dynamic range, allowing higher activity acquisitions, with no significant changes in resolution and sensitivity under NEMA test conditions. As for the image quality test, the 300 ps CTW images have less background, better SOR values, and similar RC values when comparing the 40 ns CTW.<\/jats:p>","DOI":"10.1088\/2057-1976\/adc5f5","type":"journal-article","created":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T14:48:20Z","timestamp":1743086900000},"page":"035012","update-policy":"https:\/\/doi.org\/10.1088\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Timing performance evaluation of a dual-Axis rotational PET system according to NEMA NU 4-2008 standards: A simulation study"],"prefix":"10.1088","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4435-4719","authenticated-orcid":true,"given":"P M C C","family":"Encarna\u00e7\u00e3o","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7292-7735","authenticated-orcid":true,"given":"P M M","family":"Correia","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3211-8153","authenticated-orcid":true,"given":"F M","family":"Ribeiro","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7107-7203","authenticated-orcid":true,"given":"J F C A","family":"Veloso","sequence":"additional","affiliation":[]}],"member":"266","published-online":{"date-parts":[[2025,4,7]]},"reference":[{"year":"2016","author":"Saha","key":"bpexadc5f5bib1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-16423-6"},{"key":"bpexadc5f5bib2","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1007\/s00259-011-1768-2","article-title":"Quantitative imaging of 124I and 86Y with PET","volume":"38","author":"Lubberink","year":"2011","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"key":"bpexadc5f5bib3","doi-asserted-by":"publisher","first-page":"1786","DOI":"10.2967\/jnumed.112.103507","article-title":"Engineering and performance (NEMA and animal) of a lower-cost higher-resolution animal PET\/CT scanner using photomultiplier-quadrant-sharing detectors","volume":"53","author":"Wong","year":"2012","journal-title":"J. Nucl. Med."},{"key":"bpexadc5f5bib4"},{"key":"bpexadc5f5bib5","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aba08c","article-title":"Characterization of a preclinical PET insert in a 7 tesla MRI scanner: Beyond NEMA testing","volume":"65","author":"Gsell","year":"2020","journal-title":"Phys. Med. Biol."},{"key":"bpexadc5f5bib6","doi-asserted-by":"publisher","first-page":"1432","DOI":"10.1002\/mp.15455","article-title":"Physical and imaging performance of SIAT aPET under different energy windows and timing windows","volume":"49","author":"Kuang","year":"2022","journal-title":"Med. Phys."},{"key":"bpexadc5f5bib7","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1109\/TNS.2003.817319","article-title":"Time of Flight in PET Revisited","volume":"50","author":"Moses","year":"2003","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"bpexadc5f5bib8","doi-asserted-by":"publisher","first-page":"2255","DOI":"10.1088\/0031-9155\/61\/6\/2255","article-title":"Advances in coincidence time resolution for PET","volume":"61","author":"Cates","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"bpexadc5f5bib9","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.ejmp.2020.10.031","article-title":"Update on latest advances in time-of-flight PET","volume":"80","author":"Surti","year":"2020","journal-title":"Phys. Medica"},{"key":"bpexadc5f5bib10","article-title":"Performance Measurements of Small Animal Positron Emission Tomographs (PETs)","author":"NEMA Standards Publication NU 4","year":"2008","unstructured":"NEMA Standards Publication NU 4 2008 Performance Measurements of Small Animal Positron Emission Tomographs (PETs) National Electrical Manufacturers Association https:\/\/nema.org\/Standards\/Pages\/Performance-Measurements-of-Small-Animal-Positron-Emission-Tomographs.aspx"},{"key":"bpexadc5f5bib11","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1007\/s11307-020-01491-y","article-title":"SimPET: a Preclinical PET Insert for Simultaneous PET\/MR Imaging","volume":"22","author":"Son","year":"2020","journal-title":"Molecular Imaging and Biology"},{"key":"bpexadc5f5bib12","doi-asserted-by":"publisher","first-page":"1741","DOI":"10.2967\/jnumed.111.088260","article-title":"National electrical manufacturers association NU-4 performance evaluation of the PET component of the nanoPET\/CT preclinical PET\/CT scanner","volume":"52","author":"Szanda","year":"2011","journal-title":"J. Nucl. Med."},{"key":"bpexadc5f5bib13","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aacec3","article-title":"Performance evaluation of the MOLECUBES \u03b2 -CUBE - A high spatial resolution and high sensitivity small animal PET scanner utilizing monolithic LYSO scintillation detectors","volume":"63","author":"Krishnamoorthy","year":"2018","journal-title":"Phys. Med. Biol."},{"key":"bpexadc5f5bib14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fmed.2019.00088","article-title":"Low-dose imaging in a new preclinical total-body PET\/CT scanner","volume":"6","author":"Molinos","year":"2019","journal-title":"Frontiers in Medicine"},{"key":"bpexadc5f5bib15","doi-asserted-by":"publisher","first-page":"4671","DOI":"10.1109\/NSSMIC.2008.4774465","article-title":"VrPET\/CT:Development of a rotating multimodality scanner for small-animal imaging","author":"Lage","year":"2008"},{"key":"bpexadc5f5bib16","doi-asserted-by":"publisher","first-page":"3791","DOI":"10.1088\/0031-9155\/58\/11\/3791","article-title":"NEMA NU-4 performance evaluation of PETbox4, a high sensitivity dedicated PET preclinical tomograph","volume":"58","author":"Gu","year":"2013","journal-title":"Phys. Med. Biol."},{"key":"bpexadc5f5bib17","doi-asserted-by":"publisher","first-page":"142","DOI":"10.2967\/jnumed.118.208827","article-title":"Performance evaluation of G8, a high-sensitivity benchtop preclinical PET\/CT tomograph","volume":"60","author":"Gu","year":"2019","journal-title":"J. Nucl. Med."},{"key":"bpexadc5f5bib18"},{"key":"bpexadc5f5bib19","article-title":"Positron emission tomography system and method with two rotation shafts","author":"Veloso","year":"2016","unstructured":"Veloso J F 2016 Positron emission tomography system and method with two rotation shafts Available from: https:\/\/patents.google.com\/patent\/WO2016147130A1\/en"},{"key":"bpexadc5f5bib20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/NSSMIC.2016.8069360","article-title":"The EasyPET: A novel concept for an educational cost-effective positron emission 2d scanner","author":"Arosio","year":"2016"},{"key":"bpexadc5f5bib21","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1016\/j.nima.2016.05.004","article-title":"easyPET: a novel concept for an affordable tomographic system","volume":"845","author":"Arosio","year":"2017 feb","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"bpexadc5f5bib22","article-title":"University of Aveiro","author":"Correia","year":"2018","journal-title":"Small Animal Positron Emission Tomography Systems [PhD]"},{"key":"bpexadc5f5bib23"},{"key":"bpexadc5f5bib24","doi-asserted-by":"publisher","first-page":"4543","DOI":"10.1088\/0031-9155\/49\/19\/007","article-title":"al E. GATE: a simulation toolkit for PET and SPECT","volume":"49","author":"Jan","year":"2004 oct","journal-title":"Phys. Med. Biol."},{"year":"2009","author":"Rossum","key":"bpexadc5f5bib25"},{"key":"bpexadc5f5bib26","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1038\/s41586-020-2649-2","article-title":"Array programming with NumPy","volume":"585","author":"Harris","year":"2020","journal-title":"Nature"},{"key":"bpexadc5f5bib27","first-page":"56","article-title":"Data Structures for Statistical Computing in Python","author":"McKinney","year":"2010"},{"key":"bpexadc5f5bib28","doi-asserted-by":"publisher","unstructured":"pandas development Team T. pandas-dev - pandas: Pandas. Zenodo 10.5281\/zenodo.3509134","DOI":"10.5281\/zenodo.3509134"},{"key":"bpexadc5f5bib29","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1109\/MCSE.2007.55","article-title":"Matplotlib: A 2D graphics environment","volume":"9","author":"Hunter","year":"2007","journal-title":"Comput. Sci. Eng."},{"edition":"4th edn","year":"2006","author":"Schroeder","key":"bpexadc5f5bib30"},{"key":"bpexadc5f5bib31","first-page":"262","article-title":"\u00dcber die Bestimmung von Funktionen durch ihre Integralwerte l\u00e4ngs gewisser Mannigfaltigkeiten. Mathematisch-Physische Klasse","author":"Radon","year":"1917","journal-title":"Reports on the Proceedings of the Royal Saxonian Academy of Sciences at Leipzig, Mathematical and Physical Section"},{"key":"bpexadc5f5bib32","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1109\/TMI.1986.4307775","article-title":"On the determination of functions from their integral values along certain manifolds","volume":"5","author":"Radon","year":"1986 dec","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexadc5f5bib33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40658-020-0279-2","article-title":"Comments on the NEMA NU 4-2008 Standard on Performance Measurement of Small Animal Positron Emission Tomographs","volume":"7","author":"Hallen","year":"2020","journal-title":"EJNMMI Physics"},{"key":"bpexadc5f5bib34","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1109\/TMI.1982.4307558","article-title":"Maximum likelihood reconstruction emission tomography","volume":"1","author":"Shepp","year":"1982","journal-title":"IEEE Trans. Med. Imaging"},{"key":"bpexadc5f5bib35","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1007\/s00259-020-04988-4","article-title":"LM-MLEM for an Ultra-High VoR density PET(Top rated OP-842)","volume":"47","author":"Encarna\u00e7\u00e3o","year":"2020"},{"key":"bpexadc5f5bib36","doi-asserted-by":"publisher","first-page":"1825","DOI":"10.2967\/jnumed.112.119065","article-title":"Performance evaluation of the small-animal nanoscan PET\/MRI system","volume":"54","author":"Nagy","year":"2013","journal-title":"J. Nucl. Med."},{"key":"bpexadc5f5bib37","first-page":"1717","article-title":"Treatment of axial data in three-dimensional PET","volume":"28","author":"Daube-Witherspoon","year":"1987","journal-title":"J. Nucl. Med."},{"key":"bpexadc5f5bib38","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s13550-022-00921-y","article-title":"A guideline proposal for mice preparation and care in 18F-FDG PET imaging","volume":"12","author":"Ribeiro","year":"2022","journal-title":"EJNMMI Research"}],"container-title":["Biomedical Physics &amp; Engineering Express"],"original-title":[],"link":[{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adc5f5","content-type":"text\/html","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adc5f5\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adc5f5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adc5f5\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adc5f5\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adc5f5\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adc5f5\/pdf","content-type":"application\/pdf","content-version":"am","intended-application":"similarity-checking"},{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adc5f5\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,7]],"date-time":"2025-04-07T10:50:48Z","timestamp":1744023048000},"score":1,"resource":{"primary":{"URL":"https:\/\/iopscience.iop.org\/article\/10.1088\/2057-1976\/adc5f5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,7]]},"references-count":38,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,4,7]]},"published-print":{"date-parts":[[2025,5,30]]}},"URL":"https:\/\/doi.org\/10.1088\/2057-1976\/adc5f5","relation":{},"ISSN":["2057-1976"],"issn-type":[{"type":"electronic","value":"2057-1976"}],"subject":[],"published":{"date-parts":[[2025,4,7]]},"assertion":[{"value":"Timing performance evaluation of a dual-Axis rotational PET system according to NEMA NU 4-2008 standards: A simulation study","name":"article_title","label":"Article Title"},{"value":"Biomedical Physics & Engineering Express","name":"journal_title","label":"Journal Title"},{"value":"paper","name":"article_type","label":"Article Type"},{"value":"\u00a9 2025 The Author(s). Published by IOP Publishing Ltd","name":"copyright_information","label":"Copyright Information"},{"value":"2024-07-18","name":"date_received","label":"Date Received","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-03-17","name":"date_accepted","label":"Date Accepted","group":{"name":"publication_dates","label":"Publication dates"}},{"value":"2025-04-07","name":"date_epub","label":"Online publication date","group":{"name":"publication_dates","label":"Publication dates"}}]}}