{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T13:37:33Z","timestamp":1777556253561,"version":"3.51.4"},"reference-count":22,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2023,7,31]],"date-time":"2023-07-31T00:00:00Z","timestamp":1690761600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Diabetes Technology &amp; Therapeutics"],"published-print":{"date-parts":[[2023,8]]},"abstract":"<jats:p>\n                    There are limited data on head-to-head performance of Freestyle Libre Pro (FSL-Pro) and blinded Medtronic iPro2 continuous glucose monitoring system in pregnancy. In this prospective observational study, women with hyperglycemia in pregnancy (\n                    <jats:italic toggle=\"yes\">n<\/jats:italic>\n                    \u2009=\u200942) underwent simultaneous FSL-Pro and Medtronic iPro2 sensor insertion and self-monitoring of blood glucose using Contour Plus meter (reference). The overall mean absolute relative difference (MARD) for iPro2 and FSL-Pro systems were 8.0%\u2009\u00b1\u20099.2% and 19.0%\u2009\u00b1\u200912.7%, respectively. At hypoglycemic range, both sensors performed less accurately (MARD: 18.0% and 16.8%, respectively), whereas iPro2 showed higher accuracy at euglycemic (8.2% and 19.3%, respectively) and hyperglycemic (6.8% and 18.0%, respectively) ranges. On Bland\u2013Altman analysis, iPro2 and FSL-Pro underestimated glucose by 0.01 and 1.09\u2009mmol\/L, respectively. The ISO criteria were fulfilled for 88.5% and 44.9% of all values, respectively. To conclude, iPro2 was more accurate; however, both sensors demonstrated inaccuracy at hypoglycemic range, highlighting the need for refinements in the current generation of sensors to address this problem.\n                  <\/jats:p>","DOI":"10.1089\/dia.2023.0070","type":"journal-article","created":{"date-parts":[[2023,4,27]],"date-time":"2023-04-27T08:17:32Z","timestamp":1682583452000},"page":"538-542","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of Accuracy of Freestyle Libre Pro and Medtronic iPro2 Continuous Glucose Monitoring Systems in Pregnancy"],"prefix":"10.1177","volume":"25","author":[{"given":"Kiran Kumar","family":"Golla","sequence":"first","affiliation":[{"name":"Department of Endocrinology and Metabolism, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4345-717X","authenticated-orcid":false,"given":"Yashdeep","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of Endocrinology and Metabolism, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alpesh","family":"Goyal","sequence":"additional","affiliation":[{"name":"Department of Endocrinology and Metabolism, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mani","family":"Kalaivani","sequence":"additional","affiliation":[{"name":"Department of Biostatistics, and All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Garima","family":"Kachhawa","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vidushi","family":"Kulshrestha","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aparna K.","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jyoti","family":"Meena","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juhi","family":"Bharti","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jai B.","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vatsla","family":"Dadhwal","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neena","family":"Malhotra","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neerja","family":"Bhatla","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikhil","family":"Tandon","sequence":"additional","affiliation":[{"name":"Department of Endocrinology and Metabolism, All India Institute of Medical Sciences, New Delhi, India."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2023,7,31]]},"reference":[{"key":"e_1_3_7_2_2","unstructured":"International Diabetes Federation. IDF Diabetes Atlas\u201410th ed. 2021. Diabetes Atlas. Available from: http:\/\/www.diabetesatlas.org [Last accessed: February8 2023]."},{"key":"e_1_3_7_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(17)32400-5"},{"key":"e_1_3_7_4_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2020.0667"},{"key":"e_1_3_7_5_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2021.0093"},{"key":"e_1_3_7_6_2","doi-asserted-by":"publisher","DOI":"10.1210\/clinem\/dgab502"},{"key":"e_1_3_7_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S2213-8587(22)00319-9"},{"key":"e_1_3_7_8_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2017.0035"},{"key":"e_1_3_7_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/dme.13584"},{"key":"e_1_3_7_10_2","doi-asserted-by":"publisher","DOI":"10.1177\/1479164118756240"},{"key":"e_1_3_7_11_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2014.0272"},{"key":"e_1_3_7_12_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2017.0386"},{"key":"e_1_3_7_13_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2004.6.645"},{"key":"e_1_3_7_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00592-020-01575-9"},{"key":"e_1_3_7_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.diabet.2019.08.001"},{"key":"e_1_3_7_16_2","doi-asserted-by":"publisher","DOI":"10.2337\/dc19-2073"},{"key":"e_1_3_7_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40618-016-0495-8"},{"issue":"1","key":"e_1_3_7_18_2","first-page":"E5","article-title":"Accuracy of a professional continuous glucose monitoring device in individuals with type 2 diabetes mellitus","volume":"68","author":"Nakagawa Y","year":"2022","unstructured":"Nakagawa Y, , Hirota Y, , Yamamoto A, et al. Accuracy of a professional continuous glucose monitoring device in individuals with type 2 diabetes mellitus. Kobe J Med Sci, 2022; 68(1):E5\u2013E10.","journal-title":"Kobe J Med Sci"},{"key":"e_1_3_7_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/jdi.12970"},{"key":"e_1_3_7_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/19322968211027590"},{"key":"e_1_3_7_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/1932296814532203"},{"key":"e_1_3_7_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/dom.12907"},{"key":"e_1_3_7_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.numecd.2017.10.023"}],"container-title":["Diabetes Technology &amp; Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1089\/dia.2023.0070","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/dia.2023.0070","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/dia.2023.0070","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T18:14:04Z","timestamp":1777400044000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1089\/dia.2023.0070"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,31]]},"references-count":22,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2023,8]]}},"alternative-id":["10.1089\/dia.2023.0070"],"URL":"https:\/\/doi.org\/10.1089\/dia.2023.0070","relation":{},"ISSN":["1520-9156","1557-8593"],"issn-type":[{"value":"1520-9156","type":"print"},{"value":"1557-8593","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,31]]}}}