{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T22:40:05Z","timestamp":1777588805590,"version":"3.51.4"},"reference-count":13,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2018,2,1]],"date-time":"2018-02-01T00:00:00Z","timestamp":1517443200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Endourology"],"published-print":{"date-parts":[[2018,2]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>With the introduction of laparoscopy and now robotics, more patients are able to reap benefit from minimally invasive techniques during urologic surgery. With these advancing technologies, it is important to evaluate whether the outlay of hospital capital actually improves patient care. To date, there has been little literature regarding the impact of these advances on patient outcomes. In this article, we directly compare perioperative outcomes and hospital costs between the older da Vinci Standard\/S\/Si platform and the newer Xi robotic platform during nephroureterectomy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      A review of our robotic nephroureterectomy database between April 2009 and December 2017 identified 87 patients, 30 in group 1 (Xi) and 57 in group 2 (Standard\/S\/Si). Preoperative, perioperative, and postoperative parameters as well as hospital costs were evaluated. Independent\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -test was performed for continuous variables, while categorical variables were evaluated using chi-square tests or Fisher's exact test.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      There were no significant differences between groups preoperatively. Operative time using the Xi was shorter, 184.4\n                      <jats:italic toggle=\"yes\">vs<\/jats:italic>\n                      232.09 minutes (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u20090.0035). Other perioperative variables were similar. There was more lymphovascular invasion in group 2 (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u20090.0108), but there were higher stage tumors in group 1 (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009&lt;\u20090.0001). More patients underwent lymph node dissection in group 1 (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009=\u20090.0186). Complications were similar between groups. Costs for anesthesia were less in group 1, which led to decreased total hospitalization costs (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009&lt;\u20090.001)\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Operative times were found to be less with the daVinci Xi, without any other significant difference in patient outcomes between the groups. Anesthesia and operating room cost were substantial factors in lowering the overall hospital costs. More multi-institutional studies with larger groups of patients are needed to determine if advancing technology really improves outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1089\/end.2017.0477","type":"journal-article","created":{"date-parts":[[2017,12,5]],"date-time":"2017-12-05T06:00:47Z","timestamp":1512453647000},"page":"133-138","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":43,"title":["Does Advancing Technology Improve Outcomes? Comparison of the Da Vinci Standard\/S\/Si to the Xi Robotic Platforms During Robotic Nephroureterectomy"],"prefix":"10.1177","volume":"32","author":[{"given":"Manish N.","family":"Patel","sequence":"first","affiliation":[{"name":"Wake Forest University"},{"name":"Wake Forest University Baptist Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashok K.","family":"Hemal","sequence":"additional","affiliation":[{"name":"Wake Forest University Baptist Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2018,2]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1089\/end.1998.12.139"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ju.0000148851.68215.93"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2015.07.081"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-410X.2009.08671.x"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.urology.2010.12.075"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","unstructured":"Pathak RA Patel M Hemal A. Comprehensive approach to port placement templates for robotic-assisted laparoscopic urologic surgeries. J Endourol 2017 [Epub ahead of print]; DOI: 10.1089\/end.2017.0578.","DOI":"10.1089\/end.2017.0578"},{"key":"e_1_3_2_8_2","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1111\/bju.13210","article-title":"Does transition from the da Vinci Si to Xi robotic platform impact single-docking technique for robot-assisted laparoscopic nephroureterectomy?","volume":"116","author":"Patel MN","year":"2015","unstructured":"Patel MN, , Aboumohamed A, , Hemal A. Does transition from the da Vinci Si to Xi robotic platform impact single-docking technique for robot-assisted laparoscopic nephroureterectomy?. BJU Int, 2015; 116:990\u2013994.","journal-title":"BJU Int"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1089\/lap.2013.0251"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1089\/end.2012.0394"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.eururo.2014.02.060"},{"key":"e_1_3_2_12_2","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1186\/s40064-015-1076-6","article-title":"Operative technique and early experience for robotic-assisted laparoscopic nephroureterectomy (RALNU) using Da Vinci Xi","volume":"4","author":"Darwiche F","year":"2015","unstructured":"Darwiche F, , Swain S, , Kallingal G, et al. Operative technique and early experience for robotic-assisted laparoscopic nephroureterectomy (RALNU) using Da Vinci Xi. SpringerPlus, 2015; 4:298.","journal-title":"SpringerPlus"},{"key":"e_1_3_2_13_2","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.urology.2016.02.047","article-title":"Radical nephroureterectomy without patient or port repositioning using the Da Vinci Xi robotic system: Initial experience","volume":"92","author":"Argun OB","year":"2016","unstructured":"Argun OB, , Mourmouris P, , Tufek I, et al. Radical nephroureterectomy without patient or port repositioning using the Da Vinci Xi robotic system: Initial experience. Urology, 2016; 92:136\u2013139.","journal-title":"Urology"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.sla.0000133083.54934.ae"}],"container-title":["Journal of Endourology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1089\/end.2017.0477","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/end.2017.0477","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/end.2017.0477","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T20:15:36Z","timestamp":1777407336000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.1089\/end.2017.0477"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,2]]}},"alternative-id":["10.1089\/end.2017.0477"],"URL":"https:\/\/doi.org\/10.1089\/end.2017.0477","relation":{},"ISSN":["0892-7790","1557-900X"],"issn-type":[{"value":"0892-7790","type":"print"},{"value":"1557-900X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,2]]}}}