{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T05:55:48Z","timestamp":1792130148567,"version":"4.4.0"},"reference-count":24,"publisher":"SAGE Publications","issue":"9","license":[{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Endourology"],"published-print":{"date-parts":[[2022,9]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction and Objective:<\/jats:title>\n                    <jats:p>The novel thulium fiber laser (TFL) has been shown to break stones more rapidly than the holmium:YAG laser (HL). However, some evidence suggests that the TFL generates more heat. The purpose of this study is to compare ureteral temperatures generated by these lasers during ureteroscopic laser lithotripsy in a benchtop model.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      A 1-cm BegoStone was manually impacted in the proximal ureter of a three-dimensional printed kidney-ureter model and submerged in 35.5\u00b0C saline. Lithotripsy was performed using a 7.6F flexible ureteroscope and a 200\u2009\u03bcm laser fiber without a ureteral access sheath. The Dornier 30 W HL, Olympus 100 W HL, and Olympus 60 W TFL were compared. A needle thermocouple to measure temperature was inserted 2\u2009mm from the laser tip. Irrigation was maintained at 35 cc\/minute at room temperature using the Thermedx FluidSmart System. Intraluminal temperature was continuously recorded for 60 seconds of laser activation. Five trials were performed for each of four different power settings: 3.6, 10, 20, and 30 W. Analysis of variance and Mann\u2013Whitney\n                      <jats:italic toggle=\"yes\">U<\/jats:italic>\n                      tests were performed with\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009&lt;\u20090.05 considered significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Intraureteral fluid temperature increased as laser power settings increased for all lasers (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009&lt;\u20090.05). The TFL generated higher average ureteral fluid temperatures than the Dornier and Empower HL at all power settings tested (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009&lt;\u20090.001). The maximum temperature for the TFL was higher than the Dornier and Empower HL at all power settings tested (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2009&lt;\u20090.001), except at 20 W with the Empower HL. At 30 W, the TFL exceeded 43\u00b0C, the threshold for tissue damage.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The TFL generated more heat at all settings tested. Supraphysiologic ureteral temperatures may be generated with extended use at high energy settings and low irrigation rates. Understanding the heat generation properties of both lasers could help improve the safety of ureteroscopic laser lithotripsy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1089\/end.2021.0842","type":"journal-article","created":{"date-parts":[[2022,3,18]],"date-time":"2022-03-18T09:29:10Z","timestamp":1647595750000},"page":"1249-1254","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":61,"title":["Does the Novel Thulium Fiber Laser Have a Higher Risk of Urothelial Thermal Injury than the Conventional Holmium Laser in an\n                    <i>In Vitro<\/i>\n                    Study?"],"prefix":"10.1177","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5054-1652","authenticated-orcid":false,"given":"Joshua D.","family":"Belle","sequence":"first","affiliation":[{"name":"Department of Urology, Loma Linda University Medical Center, Loma Linda, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ricky","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Urology, Loma Linda University Medical Center, Loma Linda, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathaniel","family":"Srikureja","sequence":"additional","affiliation":[{"name":"Department of Urology, Loma Linda University Medical Center, Loma Linda, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akin S.","family":"Amasyali","sequence":"additional","affiliation":[{"name":"Department of Urology, Loma Linda University Medical Center, Loma Linda, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed","family":"Keheila","sequence":"additional","affiliation":[{"name":"Department of Urology, Loma Linda University Medical Center, Loma Linda, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. Duane","family":"Baldwin","sequence":"additional","affiliation":[{"name":"Department of Urology, Loma Linda University Medical Center, Loma Linda, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2022,9,1]]},"reference":[{"key":"e_1_3_5_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00345-019-02654-5"},{"key":"e_1_3_5_3_2","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.9.004552"},{"key":"e_1_3_5_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/lsm.23057"},{"key":"e_1_3_5_5_2","unstructured":"MAUDE Adverse Event Report: Gyrus ACMI Inc SOLTIVE Premium SuperPulsed Laser System Powered Laser Surgical Instrument: U.S. Food and Drug Administration 2021. Available at https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfMAUDE\/detail.cfm?mdrfoi__id=12043126&pc=GEX Last accessed Aug 6th 2021."},{"key":"e_1_3_5_6_2","unstructured":"MAUDE Adverse Event Report: Gyrus ACMI INC SOLTIVE Premium SuperPulsed Laser System SOLTIVE Laser system: U.S. Food and Drug Administration 2021. Available at https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfMAUDE\/detail.cfm?mdrfoi__id=10782150&pc=GEX Last accessed Aug 6th 2021."},{"key":"e_1_3_5_7_2","unstructured":"TGA Recall: SFDA National Center for Medical Devices Reporting 2021 Available at https:\/\/ncmdr.sfda.gov.sa\/Secure\/CA\/CaViewRecall.aspx?caid=10&rid=15757 Last accessed Aug 6th 2021."},{"key":"e_1_3_5_8_2","unstructured":"Soltive Premium Superpulsed Laser System Recalls and Safety Alerts: Health Canada 2021. Available at: https:\/\/healthycanadians.gc.ca\/recall-alert-rappel-avis\/hc-sc\/2021\/75943r-eng.php Last accessed Aug 6th 2021."},{"key":"e_1_3_5_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2011.10.147"},{"key":"e_1_3_5_10_2","doi-asserted-by":"publisher","DOI":"10.1089\/end.2014.0850"},{"key":"e_1_3_5_11_2","doi-asserted-by":"publisher","DOI":"10.4103\/0259-1162.134508"},{"key":"e_1_3_5_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(84)90379-1"},{"key":"e_1_3_5_13_2","doi-asserted-by":"publisher","DOI":"10.3109\/02656736.2010.534527"},{"key":"e_1_3_5_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2007.09.107"},{"key":"e_1_3_5_15_2","doi-asserted-by":"publisher","DOI":"10.1089\/end.2017.0658"},{"key":"e_1_3_5_16_2","doi-asserted-by":"publisher","DOI":"10.1089\/end.2018.0395"},{"key":"e_1_3_5_17_2","doi-asserted-by":"publisher","DOI":"10.1089\/end.2019.0426"},{"key":"e_1_3_5_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00345-021-03619-3"},{"key":"e_1_3_5_19_2","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.19.12.128001"},{"key":"e_1_3_5_20_2","first-page":"e73","article-title":"PD04-02 thermal dose during holmium laser lithotripsy: In vitro ureteral model","volume":"201","author":"Aldoukhi AH","year":"2019","unstructured":"Aldoukhi AH, , Black KM, , Hall TL, , Ghani KR, , Maxwell AD, , MacConaghy B, et al. PD04-02 thermal dose during holmium laser lithotripsy: In vitro ureteral model. J Urol, 2019; 201:e73\u2013e74.","journal-title":"J Urol"},{"key":"e_1_3_5_21_2","first-page":"487","volume-title":"Optical-Thermal Response of Laser-Irradiated Tissue","author":"Thomsen S","year":"2011","unstructured":"Thomsen S, , Pearce JA. Thermal damage and rate processes in biologic tissues. In: Welch AJ, , van Gemert MJC, eds. Optical-Thermal Response of Laser-Irradiated Tissue. Dordrecht: Springer Netherlands, 2011, pp. 487\u2013549."},{"key":"e_1_3_5_22_2","doi-asserted-by":"publisher","DOI":"10.1089\/end.2017.0298"},{"key":"e_1_3_5_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2017.08.039"},{"key":"e_1_3_5_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00345-018-2379-3"},{"key":"e_1_3_5_25_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.178.1.1780047"}],"container-title":["Journal of Endourology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1089\/end.2021.0842","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/end.2021.0842","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/end.2021.0842","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T20:14:27Z","timestamp":1777407267000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1089\/end.2021.0842"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9]]},"references-count":24,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2022,9]]}},"alternative-id":["10.1089\/end.2021.0842"],"URL":"https:\/\/doi.org\/10.1089\/end.2021.0842","relation":{},"ISSN":["0892-7790","1557-900X"],"issn-type":[{"value":"0892-7790","type":"print"},{"value":"1557-900X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9]]}}}