{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T19:07:53Z","timestamp":1777921673219,"version":"3.51.4"},"reference-count":11,"publisher":"SAGE Publications","issue":"9","license":[{"start":{"date-parts":[[2024,9,1]],"date-time":"2024-09-01T00:00:00Z","timestamp":1725148800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Laparoendoscopic &amp; Advanced Surgical Techniques"],"published-print":{"date-parts":[[2024,9,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Modified Anderson-Hynes pyeloplasty is currently preferred for ureteropelvic junction obstruction (UPJO). Extravasation of urine and anastomotic stenosis are the most common complications after Anderson-Hynes pyeloplasty, which are closely linked with the technique for anastomosis. However, there are currently no clear guidelines for the suture bite depth in suturing the anastomosis during pyeloplasty.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To analyze the optimal suture bite depth in laparoscopic Anderson-Hynes pyeloplasty.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>\n                      A total of 90 children aged 4\u201314 years with UPJO-induced hydronephrosis who were surgically treated in the First People's Hospital of Lianyungang from July 2019 to July 2022 were prospectively recruited. All received laparoscopic Anderson-Hynes pyeloplasty using 5-0 Vicryl continuous sutures. According to the suture bite depth, the patients were divided into group A (depth 1\u2009mm,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      \u2009=\u200946) and group B (depth 0.5\u2009mm,\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      \u2009=\u200944). Operation time, postoperative drainage volume, time of ureteral stent removal, incidence of postoperative complications, and time to hydronephrosis resolution were compared between groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Group A showed significantly less postoperative drainage volume, and shorter time of ureteral stent removal and hydronephrosis resolution (all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;\u2009.05). Four cases in group B received replacement of a double-J stent. Except for 1 patient receiving reoperation for anastomotic stenosis caused by massive extravasation of urine, the replaced double-J stent was successfully removed from the remaining 3 patients at 3 months, and the symptoms of anastomotic stenosis disappeared. No significant difference was detected in the operation time between groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&gt;\u2009.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>An appropriate deeper suture bite depth for anastomosis may reduce postoperative urine extravasation and related complications in children who received laparoscopic pyeloplasty for UPJO-induced hydronephrosis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1089\/lap.2023.0434","type":"journal-article","created":{"date-parts":[[2024,3,4]],"date-time":"2024-03-04T09:55:16Z","timestamp":1709546116000},"page":"871-875","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":0,"title":["The Optimal Suture Bite Depth in Laparoscopic Pyeloplasty: A Comparative Study in Children"],"prefix":"10.1177","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8071-8105","authenticated-orcid":false,"given":"Shaodong","family":"Gu","sequence":"first","affiliation":[{"name":"Department of Pediatric Surgery, The First People's Hospital of Lianyungang, Lianyungang, China."},{"name":"The Affiliated Lianyungang Hospital of Xuzhou Medical University\/The First People's Hospital of Lianyungang, Lianyungang, China."},{"name":"The First Affiliated Hospital of Kangda College of Nanjing Medical University\/The First People's Hospital of Lianyungang, Lianyungang, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong","family":"Luo","sequence":"additional","affiliation":[{"name":"Department of Pediatric Surgery, The First People's Hospital of Lianyungang, Lianyungang, China."},{"name":"The Affiliated Lianyungang Hospital of Xuzhou Medical University\/The First People's Hospital of Lianyungang, Lianyungang, China."},{"name":"The First Affiliated Hospital of Kangda College of Nanjing Medical University\/The First People's Hospital of Lianyungang, Lianyungang, China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2024,9,16]]},"reference":[{"key":"e_1_3_7_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11701-023-01559-1"},{"key":"e_1_3_7_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00383-022-05173-4"},{"key":"e_1_3_7_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00383-021-04960-9"},{"key":"e_1_3_7_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00345-019-02943-z"},{"key":"e_1_3_7_6_2","doi-asserted-by":"publisher","DOI":"10.1159\/000471963"},{"key":"e_1_3_7_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01076947"},{"key":"e_1_3_7_8_2","doi-asserted-by":"publisher","DOI":"10.1089\/end.2016.0655"},{"key":"e_1_3_7_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00383-020-04699-9"},{"key":"e_1_3_7_10_2","doi-asserted-by":"publisher","DOI":"10.1089\/lap.2021.0452"},{"key":"e_1_3_7_11_2","doi-asserted-by":"publisher","DOI":"10.1590\/s1677-5538.ibju.2022.0194"},{"key":"e_1_3_7_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.sempedsurg.2021.151083"}],"container-title":["Journal of Laparoendoscopic &amp; Advanced Surgical Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1089\/lap.2023.0434","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/lap.2023.0434","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/lap.2023.0434","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T19:59:33Z","timestamp":1777665573000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1089\/lap.2023.0434"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,1]]},"references-count":11,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2024,9,1]]}},"alternative-id":["10.1089\/lap.2023.0434"],"URL":"https:\/\/doi.org\/10.1089\/lap.2023.0434","relation":{},"ISSN":["1092-6429","1557-9034"],"issn-type":[{"value":"1092-6429","type":"print"},{"value":"1557-9034","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,1]]}}}