{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T15:46:14Z","timestamp":1787586374237,"version":"build-2736575974"},"reference-count":17,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Lymphatic Research and Biology"],"published-print":{"date-parts":[[2022,2,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Measuring lymphedema with high accuracy is important for several reasons. The aim of this study was to assess the reliability and validity of three routinely used methods to estimate limb volumes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and Results:<\/jats:title>\n                    <jats:p>Inverse water displacement, girth measurements, and Perometer measurements were executed. Although standard techniques were used, extra precautions were taken to maximize accuracy within and between observers. Water displacement, and girth and Perometer measurements resulted in standard deviations of 0.7%\u20130.8%, 0.5%, and 0.4%\u20131.0%, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Measuring limb volumes using routine methods is not easy. Even under optimal conditions, the measurements are quite dependent on the observer. For practical situations, an easy, objective, and reliable method is lacking.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1089\/lrb.2019.0082","type":"journal-article","created":{"date-parts":[[2021,3,22]],"date-time":"2021-03-22T17:08:31Z","timestamp":1616432911000},"page":"48-52","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":17,"title":["Estimates for Assessment of Lymphedema: Reliability and Validity of Extremity Measurements"],"prefix":"10.1177","volume":"20","author":[{"given":"Frans","family":"Houwen","sequence":"first","affiliation":[{"name":"Peracutus B.V., Kronenberg, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johannes","family":"Stemkens","sequence":"additional","affiliation":[{"name":"Stemkens.Com B.V., Roggel, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter J.","family":"de Schipper","sequence":"additional","affiliation":[{"name":"Health Innovations and Technology, Fontys University of Applied Sciences, Eindhoven, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pim","family":"van der Wouw","sequence":"additional","affiliation":[{"name":"Health Innovations and Technology, Fontys University of Applied Sciences, Eindhoven, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martijn","family":"Heitink","sequence":"additional","affiliation":[{"name":"Department of Dermatology, Zuyderland Medical Centre, Heerlen, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Herman","family":"van Langen","sequence":"additional","affiliation":[{"name":"Department of Medical Physics and Devices, VieCuri Medical Centre, Venlo, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2022,2,28]]},"reference":[{"key":"e_1_3_4_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-4632.2008.03959.x"},{"key":"e_1_3_4_3_2","doi-asserted-by":"publisher","DOI":"10.1080\/17441692.2010.549140"},{"key":"e_1_3_4_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10549-006-9213-0"},{"key":"e_1_3_4_5_2","first-page":"57","article-title":"Limb circumference measurement for recording edema volume in patients with filarial lymphedema","volume":"28","author":"Pani SP","year":"1995","unstructured":"Pani SP, , Vanamail P, , Yuvaraj J. Limb circumference measurement for recording edema volume in patients with filarial lymphedema. Lyphology, 1995; 28:57\u201363.","journal-title":"Lyphology"},{"key":"e_1_3_4_6_2","first-page":"26","article-title":"Reliability and limits of agreement of circumferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema","volume":"40","author":"Deltombe T","year":"2007","unstructured":"Deltombe T, , Jamart J, , Recloux S, et al. Reliability and limits of agreement of circumferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema. Lymphology, 2007; 40:26\u201334.","journal-title":"Lymphology"},{"key":"e_1_3_4_7_2","doi-asserted-by":"publisher","DOI":"10.3109\/07357900902918494"},{"key":"e_1_3_4_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/ptj\/83.2.134"},{"key":"e_1_3_4_9_2","doi-asserted-by":"publisher","DOI":"10.1093\/ptj\/pzz175"},{"key":"e_1_3_4_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2020.105795"},{"key":"e_1_3_4_11_2","doi-asserted-by":"publisher","DOI":"10.1089\/lrb.2018.0037"},{"key":"e_1_3_4_12_2","volume-title":"8th International Lymphedema Framework Conference","author":"Martignon M","unstructured":"Martignon M, , Vankerckhove S, , Fung LH, , Vandermeeren L, , Belgrado J-P. Evaluation of the reliability of four measuring methods of hand's perimeter and volume: Bouyancy Forces ValGrado system, circumference measurement, Figure-of-Eight Method and Manu3metrix scanner. In: 8th International Lymphedema Framework Conference, Rotterdam, 2018."},{"key":"e_1_3_4_13_2","first-page":"2006","volume-title":"CRC Handbook of Chemistry and Physics","author":"Lide DR","unstructured":"Lide DR. CRC Handbook of Chemistry and Physics, 87th ed. Boca Raton: CRC Press; 2006\u20132007."},{"key":"e_1_3_4_14_2","first-page":"228","article-title":"Determination of volume from circumferential measurements [in German]","volume":"24","author":"Kuhnke E","year":"1976","unstructured":"Kuhnke E. Determination of volume from circumferential measurements [in German]. Folia Angiol, 1976; 24:228\u2013232.","journal-title":"Folia Angiol"},{"key":"e_1_3_4_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.physio.2012.12.004"},{"key":"e_1_3_4_16_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2288-11-138"},{"key":"e_1_3_4_17_2","doi-asserted-by":"publisher","DOI":"10.1089\/lrb.2014.0007"},{"key":"e_1_3_4_18_2","doi-asserted-by":"publisher","DOI":"10.1089\/lrb.2015.0011"}],"container-title":["Lymphatic Research and Biology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1089\/lrb.2019.0082","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/lrb.2019.0082","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/lrb.2019.0082","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T20:12:57Z","timestamp":1777666377000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1089\/lrb.2019.0082"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,1]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,2,1]]}},"alternative-id":["10.1089\/lrb.2019.0082"],"URL":"https:\/\/doi.org\/10.1089\/lrb.2019.0082","relation":{},"ISSN":["1539-6851","1557-8585"],"issn-type":[{"value":"1539-6851","type":"print"},{"value":"1557-8585","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,1]]}}}