{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T23:18:43Z","timestamp":1785280723372,"version":"3.55.0"},"reference-count":29,"publisher":"SAGE Publications","issue":"9","license":[{"start":{"date-parts":[[2022,9,1]],"date-time":"2022-09-01T00:00:00Z","timestamp":1661990400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Tissue Engineering Part C: Methods"],"published-print":{"date-parts":[[2022,9,1]]},"abstract":"<jats:p>Goat is an adequate experimental model for cervical spine testing. However, studies on the anatomy of the cervical spine in goats are limited, and there is no uniform standard for establishing a single-segment anterior cervical discectomy and fusion (ACDF) model in goats. To address this issue, we investigated the cervical spine anatomy of goats and provided a technical basis for establishing a single-segment ACDF model in goats. We measured the imaging anatomical parameters using Mimics Medical 20.0 software. We then performed histological analysis of the cervical spine segment 2\u20133 (C2\u20133) segment of six goat cervical spine specimens. Based on the measurements and histological analysis, the fusion cage was designed to be wedge-shaped, the length of the plate was 25\u2009mm, and the length of the screw was 15\u2009mm. Based on the anatomical characteristics of goats, we believed that the C2\u20133 segment of goats was most suitable for a single-segment ACDF model in goats, and the decompression should be performed medial to the pterygoid joint on both sides, the thickness of the removed endplate was \u223c0.6\u2009mm, the cage implanted in the anterior two-thirds of the intervertebral space could maximize the contact area of the cage-endplate interface, and the location of the midline spur could position the implantation of the internal fixtures. Radiological examination at 12 weeks postoperatively suggested that the internal fixtures were in place and new bone formation was visible. These results demonstrated that these technical notes based on anatomical features were practical and could minimize damage to animals.<\/jats:p>","DOI":"10.1089\/ten.tec.2022.0133","type":"journal-article","created":{"date-parts":[[2022,8,5]],"date-time":"2022-08-05T10:22:12Z","timestamp":1659694932000},"page":"476-488","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":4,"title":["Technical Notes for Establishing a Cervical Fusion Model in Goats Based on Distinctive Anatomy"],"prefix":"10.1177","volume":"28","author":[{"given":"Haiyuan","family":"Yang","sequence":"first","affiliation":[{"name":"Department of Orthopedics, Huashan Hospital, Fudan University, Shanghai, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Huashan Hospital, Fudan University, Shanghai, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haocheng","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Huashan Hospital, Fudan University, Shanghai, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Huashan Hospital, Fudan University, Shanghai, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feizhou","family":"Lyu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Huashan Hospital, Fudan University, Shanghai, China."},{"name":"Department of Orthopedics, Shanghai Fifth People's Hospital, Fudan University, Shanghai, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2022,9,13]]},"reference":[{"key":"e_1_3_5_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-007-0485-9"},{"key":"e_1_3_5_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199710150-00009"},{"key":"e_1_3_5_4_2","doi-asserted-by":"publisher","DOI":"10.3171\/SPI-07\/11\/549"},{"key":"e_1_3_5_5_2","doi-asserted-by":"crossref","unstructured":"Smith GW Robinson RA. The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am 1958;40-A(3):607\u2013624; doi: 10.2106\/00004623-195840030-00009.","DOI":"10.2106\/00004623-195840030-00009"},{"key":"e_1_3_5_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000002925"},{"key":"e_1_3_5_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01400873"},{"key":"e_1_3_5_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jot.2020.01.002"},{"key":"e_1_3_5_9_2","article-title":"Anterior cervical discectomy and fusion","author":"Zdeblick TA","year":"1992","unstructured":"Zdeblick TA, , Wilson D, , Cooke ME, et al. Anterior cervical discectomy and fusion. A comparison of techniques in an animal model. Spine, 1992;17(10 Suppl):S418\u2013S426; doi: 10.1097\/00007632-199210001-00013.","journal-title":"A comparison of techniques in an animal model. Spine"},{"key":"e_1_3_5_10_2","article-title":"Suitability of bioresorbable cages for anterior cervical fusion","author":"Cahill DW","year":"2003","unstructured":"Cahill DW, , Martin GJJr, ., Hajjar MV, et al. Suitability of bioresorbable cages for anterior cervical fusion. J Neurosurg, 2003;98(2 Suppl):195\u2013201; doi: 10.3171\/spi.2003.98.2.0195.","journal-title":"J Neurosurg"},{"key":"e_1_3_5_11_2","article-title":"Bioabsorbable high-purity magnesium interbody cage: Degradation, interbody fusion, and biocompatibility from a goat cervical spine model","author":"Guo X","year":"2020","unstructured":"Guo X, , Xu H, , Zhang F, et al. Bioabsorbable high-purity magnesium interbody cage: Degradation, interbody fusion, and biocompatibility from a goat cervical spine model. Ann Transl Med, 2020;8(17):1054-; doi: 10.21037\/atm-20-225.","journal-title":"Ann Transl Med"},{"key":"e_1_3_5_12_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-021-04412-4"},{"key":"e_1_3_5_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-009-1192-5"},{"key":"e_1_3_5_14_2","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/7961509"},{"key":"e_1_3_5_15_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-018-2027-5"},{"key":"e_1_3_5_16_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20140124-13"},{"key":"e_1_3_5_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181dfcec9"},{"key":"e_1_3_5_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0185(199704)247:4<542::AID-AR13>3.0.CO;2-P"},{"key":"e_1_3_5_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200105010-00008"},{"key":"e_1_3_5_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-006-0284-8"},{"key":"e_1_3_5_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/2192568220963061"},{"key":"e_1_3_5_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181695716"},{"key":"e_1_3_5_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jot.2021.11.001"},{"key":"e_1_3_5_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2013.05.027"},{"key":"e_1_3_5_25_2","doi-asserted-by":"publisher","DOI":"10.3349\/ymj.2016.57.4.968"},{"key":"e_1_3_5_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3182512425"},{"key":"e_1_3_5_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00701-015-2594-2"},{"key":"e_1_3_5_28_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1439-0264.2007.00829.x"},{"key":"e_1_3_5_29_2","doi-asserted-by":"publisher","DOI":"10.1111\/joa.13402"},{"key":"e_1_3_5_30_2","doi-asserted-by":"crossref","unstructured":"Choi JY Sung KH. Subsidence after anterior lumbar interbody fusion using paired stand-alone rectangular cages. Eur Spine J 2006;15(1):16\u201322; doi: 10.1007\/s00586-004-0817-y.","DOI":"10.1007\/s00586-004-0817-y"}],"container-title":["Tissue Engineering Part C: Methods"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1089\/ten.tec.2022.0133","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/ten.tec.2022.0133","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1089\/ten.tec.2022.0133","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T05:19:27Z","timestamp":1777699167000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1089\/ten.tec.2022.0133"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,1]]},"references-count":29,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2022,9,1]]}},"alternative-id":["10.1089\/ten.tec.2022.0133"],"URL":"https:\/\/doi.org\/10.1089\/ten.tec.2022.0133","relation":{},"ISSN":["1937-3384","1937-3392"],"issn-type":[{"value":"1937-3384","type":"print"},{"value":"1937-3392","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,1]]}}}