{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T11:19:07Z","timestamp":1761218347396,"version":"3.37.3"},"reference-count":49,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2021,3,12]],"date-time":"2021-03-12T00:00:00Z","timestamp":1615507200000},"content-version":"vor","delay-in-days":1,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,4,28]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Most of the building energy is mainly contributing to the achievement of thermal comfort. The cooling load on air conditioners will increase with increased heat transfer into the building from the surroundings. The amount of heat transfer into the building mainly depends on building materials used in construction. In this research, an attempt has been made to analyse the self-sufficient homes\u2019 concept by visualizing variation in heat transfer of the building concerning ordinary clay brick and brick with sinicon composition. The temperature distribution of airflow, time lag, decrement factor, and comfort conditions are investigated concerning these materials with computational fluid dynamics. Numerical modeling has been defined by selecting three-dimensional fluid flow governing equations and the k\u2013\u03b5 turbulence model. All the fluid flow governing equations have been solved with the finite-volume second-order upwind discretization and SIMPLE algorithm for pressure\u2013velocity coupling. Numerical results have been analysed for both the materials and we identified that the sinicon brick material for the considered wall thickness (9 inches) had registered an increased time lag (\u223c2 hrs) and a decreased decrement factor (0.05). This research investigation shows that the sinicon-brick wall strongly decreases heat transfer through it compared to the normal-red brick wall. The sinicon brick significantly reduces the air conditioner\u2019s cooling load by decreasing heat energy penetration into the building.<\/jats:p>","DOI":"10.1093\/jcde\/qwab013","type":"journal-article","created":{"date-parts":[[2021,2,15]],"date-time":"2021-02-15T13:39:47Z","timestamp":1613396387000},"page":"773-787","source":"Crossref","is-referenced-by-count":3,"title":["Computational investigation of heat energy interaction for a residential building with a normal clay brick and sinicon brick"],"prefix":"10.1093","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5088-3329","authenticated-orcid":false,"given":"Obula Reddy","family":"Kummitha","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, B V Raju Institute of Technology, Narsapur 502313, Telangana, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R Vijay","family":"Kumar","sequence":"additional","affiliation":[{"name":"Department of Civil Engineering, B V Raju Institute of Technology, Narsapur 502313, Telangana, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2021,3,11]]},"reference":[{"issue":"4","key":"2021042911565294700_bib1","first-page":"1","article-title":"Thermal characteristics of laterite-mud and concrete block for walls in building construction in Nigeria","volume":"4","author":"Alausa","year":"2013","journal-title":"International Journal of Engineering and Applied Sciences"},{"key":"2021042911565294700_bib2","first-page":"2000","article-title":"Construction of a test room for evaluating thermal performance of building wall systems under real conditions","volume":"2","author":"Almujahid","year":"2013","journal-title":"International Journal of Innovative Research in Science, Engineering and Technology"},{"key":"2021042911565294700_bib3","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/S0378-7788(98)00030-9","article-title":"Effects of wall\u2019s insulation thickness and position on time lag and decrement factor","volume":"28","author":"Asan","year":"1998","journal-title":"Energy and Buildings"},{"key":"2021042911565294700_bib4","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S0378-7788(00)00044-X","article-title":"Investigation of wall\u2019s optimum insulation position from maximum time lag and minimum decrement factor point of view","volume":"32","author":"Asan","year":"2000","journal-title":"Energy and Buildings"},{"key":"2021042911565294700_bib5","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/j.buildenv.2005.02.020","article-title":"Numerical computation of time lags and decrement factors for different building materials","volume":"41","author":"Asan","year":"2006","journal-title":"Building and Environment"},{"key":"2021042911565294700_bib6","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/S0378-7788(98)00007-3","article-title":"Effects of wall\u2019s thermo physical properties on time lag and decrement factor","volume":"28","author":"Asan","year":"1998","journal-title":"Energy and Buildings"},{"issue":"2","key":"2021042911565294700_bib7","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1080\/19401493.2010.513740","article-title":"Application of computational fluid dynamics in building performance simulation for the outdoor environment: An overview","volume":"4","author":"Blocken","year":"2011","journal-title":"Journal of Building Performance Simulation"},{"issue":"4","key":"2021042911565294700_bib8","doi-asserted-by":"crossref","first-page":"90","DOI":"10.3390\/buildings7040090","article-title":"Numerical modelling for the thermal performance assessment of a semi-opaque fa\u00e7ade with a multilayer of nano-structured and phase change materials","volume":"7","author":"Carla","year":"2017","journal-title":"Buildings"},{"key":"2021042911565294700_bib9","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1080\/10407799508928838","article-title":"Comparison of different k-\u03b5 models for indoor airflow computations","volume":"28","author":"Chen","year":"1995","journal-title":"Numerical Heat Transfer, Part B: Fundamentals"},{"issue":"3","key":"2021042911565294700_bib10","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/0360-1323(95)00049-6","article-title":"Prediction of room air motion by Reynolds-stress models","volume":"31","author":"Chen","year":"1996","journal-title":"Building and Environment"},{"issue":"1","key":"2021042911565294700_bib11","first-page":"14","article-title":"Application of CFD tools for indoor and outdoor environment design","volume":"1","author":"Chen","year":"2000","journal-title":"International Journal on Architectural Science"},{"key":"2021042911565294700_bib12","article-title":"Analysis of building systems performance through integrated computation fluid dynamics technique","volume-title":"Proceedings of the 13th Asian Congress of Fluid Mechanics","author":"Chowdhury","year":"2010"},{"key":"2021042911565294700_bib13","first-page":"R9651","article-title":"Large eddy simulations of the flow in a three-dimensional ventilated room","volume":"59","author":"Davidson","year":"1996","journal-title":"Indoor Environmental Technology"},{"key":"2021042911565294700_bib15","article-title":"A comparative study of the thermal performance of building materials","volume-title":"The 23rd Conference on Passive and Low Energy Architecture","author":"Elias-Ozkan","year":"2006"},{"issue":"5","key":"2021042911565294700_bib16","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.enbuild.2005.08.008","article-title":"Computational analysis of wind driven natural ventilation in buildings","volume":"38","author":"Evola","year":"2006","journal-title":"Energy and Buildings"},{"key":"2021042911565294700_bib17","doi-asserted-by":"crossref","DOI":"10.4172\/2165-784X.1000S1-001","article-title":"Simulation of airflow and wind pressure coefficient in a naturally ventilated classroom model using environmental wind tunnel and CFD modelling","author":"Goyal","year":"2012","journal-title":"Journal of Civil and Environmental Engineering"},{"key":"2021042911565294700_bib18","doi-asserted-by":"crossref","first-page":"103607","DOI":"10.1063\/1.5124516","article-title":"Natural convection of water-based carbon nanotubes in a partially heated rectangular fin-shaped cavity with an inner cylindrical obstacle","volume":"31","author":"Hamid","year":"2019","journal-title":"Physics of Fluids"},{"issue":"4","key":"2021042911565294700_bib19","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1016\/j.jcde.2019.03.004","article-title":"Natural convection effects on heat and mass transfer of slip flow of time-dependent Prandtl fluid","volume":"6","author":"Hamid","year":"2019","journal-title":"Journal of Computational Design and Engineering"},{"key":"2021042911565294700_bib20","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1016\/j.applthermaleng.2015.12.138","article-title":"Stagnation electrical MHD nanofluid mixed convection with slip boundary on a stretching sheet","volume":"98","author":"Hsiao","year":"2016","journal-title":"Applied Thermal Engineering"},{"key":"2021042911565294700_bib21","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1016\/j.applthermaleng.2016.08.208","article-title":"Combined electrical MHD heat transfer thermal extrusion system using Maxwell fluid with radiative and viscous dissipation effects","volume":"112","author":"Hsiao","year":"2017","journal-title":"Applied Thermal Engineering"},{"key":"2021042911565294700_bib22","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.energy.2017.05.004","article-title":"To promote radiation electrical MHD activation energy thermal extrusion manufacturing system efficiency by using Carreau-nanofluid with parameters control method","volume":"130","author":"Hsiao","year":"2017","journal-title":"Energy"},{"key":"2021042911565294700_bib23","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1016\/j.ijheatmasstransfer.2017.05.042","article-title":"Micropolar nanofluid flow with MHD and viscous dissipation effects towards a stretching sheet with multimedia feature","volume":"112","author":"Hsiao","year":"2017","journal-title":"International Journal of Heat and Mass Transfer"},{"issue":"3","key":"2021042911565294700_bib24","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/S0167-6105(02)00380-X","article-title":"Natural ventilation in buildings: Measurement in a wind tunnel and numerical simulation with large-eddy simulation","volume":"91","author":"Jiang","year":"2003","journal-title":"Journal of Wind Engineering and Industrial Aerodynamics"},{"issue":"6","key":"2021042911565294700_bib25","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1016\/j.enbuild.2006.10.007","article-title":"The international building physics toolbox in Simulink","volume":"39","author":"Kalagasidis","year":"2007","journal-title":"Energy and Buildings"},{"issue":"6","key":"2021042911565294700_bib26","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1016\/S0360-1323(00)00063-9","article-title":"Hygrothermal system-performance of a whole building","volume":"36","author":"Karagiozis","year":"2001","journal-title":"Building and Environment"},{"key":"2021042911565294700_bib27","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1007\/s10973-019-09201-9","article-title":"Non-Newtonian fluid flow around a Y-shaped fin embedded in a square cavity","volume":"143","author":"Khan","year":"2021","journal-title":"Journal of Thermal Analysis and Calorimetry"},{"key":"2021042911565294700_bib28","doi-asserted-by":"crossref","first-page":"093609","DOI":"10.1063\/5.0021638","article-title":"Finite element analysis of hybrid nanofluid flow and heat transfer in a split lid-driven square cavity with Y-shaped obstacle","volume":"32","author":"Khan","year":"2020","journal-title":"Physics of Fluids"},{"key":"2021042911565294700_bib29","doi-asserted-by":"crossref","first-page":"104640","DOI":"10.1016\/j.icheatmasstransfer.2020.104640","article-title":"Effects of volume fraction on water-based carbon nanotubes flow in a right-angle trapezoidal cavity: FEM based analysis","volume":"116","author":"Khan","year":"2020","journal-title":"International Communications in Heat and Mass Transfer"},{"issue":"4","key":"2021042911565294700_bib30","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.solener.2004.03.002","article-title":"Simulation of indoor temperature and humidity conditions including hygrothermal interactions with the building envelope","volume":"78","author":"Kunzel","year":"2005","journal-title":"Solar Energy"},{"key":"2021042911565294700_bib31","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/0045-7825(74)90029-2","article-title":"The numerical computation of turbulent flows","volume":"3","author":"Launder","year":"1974","journal-title":"Computer Method in Applied Mechanics and Energy"},{"key":"2021042911565294700_bib32","article-title":"Effect of wall thermal properties on the energy consumption of buildings in the gaza strip, ISBS","volume-title":"Second International Sustainable Buildings Symposium","author":"Muhaisen","year":"2015"},{"issue":"2","key":"2021042911565294700_bib33","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1080\/17512549.2016.1215260","article-title":"Simulation studies on small rural residential houses using sustainable building materials for thermal comfort \u2013 case comparison","volume":"11","author":"Nadarajan","year":"2016","journal-title":"Advances in Building Energy Research"},{"key":"2021042911565294700_bib34","doi-asserted-by":"crossref","first-page":"2178","DOI":"10.1016\/j.buildenv.2006.04.012","article-title":"Environmental performance evaluation of thermal insulation materials and its impact on the building","volume":"42","author":"Papadopoulous","year":"2007","journal-title":"Building and Environment"},{"key":"2021042911565294700_bib35","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1007\/s12273-009-9317-7","article-title":"Analysis of thermal comfort in an office room by varying the dimensions of the windows on adjacent walls using CFD: A case study based on numerical simulation","volume":"2","author":"Ravikumar","year":"2009","journal-title":"Building Simulation"},{"key":"2021042911565294700_bib36","article-title":"Research into the thermal performance of traditional brick walls","volume-title":"English Heritage Research Report","author":"Rhee-Duverne","year":"2013"},{"key":"2021042911565294700_bib37","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1002\/ese3.333","article-title":"Computational fluid dynamics analysis of heat transfer in a greenhouse solar dryer \u201cchapel-type\u201d coupled to an air solar heating system","volume":"7","author":"Rom\u00e1n-Rold\u00e1n","year":"2018","journal-title":"Energy Science and Engineering"},{"issue":"5","key":"2021042911565294700_bib38","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1080\/09613210600822402","article-title":"Multi criteria analysis of health, comfort and energy efficiency in buildings","volume":"34","author":"Roulet","year":"2006","journal-title":"Building Research and Information"},{"key":"2021042911565294700_bib39","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/j.egypro.2015.11.564","article-title":"Effect of air space thickness within the external walls on the dynamic thermal behaviour of building envelopes for energy efficient building construction","volume":"79","author":"Shaik","year":"2015","journal-title":"Energy Procedia"},{"key":"2021042911565294700_bib40","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.buildenv.2016.01.030","article-title":"Influence of ambient air relative humidity and temperature on thermal properties and unsteady thermal response characteristics of laterite wall houses","volume":"99","author":"Shaik","year":"2016","journal-title":"Building and Environment"},{"key":"2021042911565294700_bib41","doi-asserted-by":"crossref","first-page":"9334","DOI":"10.1007\/s11356-015-5316-7","article-title":"Optimizing the position of insulating materials in flat roofs exposed to sunshine to gain minimum heat into buildings under periodic heat transfer conditions","volume":"23","author":"Shaik","year":"2016","journal-title":"Environmental Science and Pollution Research"},{"key":"2021042911565294700_bib42","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/s10901-006-9042-9","article-title":"Appropriate energy efficient building envelope technologies for social housing in the Irish climate","volume":"21","author":"Shanks","year":"2006","journal-title":"Journal of Housing and the Built Environment"},{"issue":"4","key":"2021042911565294700_bib43","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1034\/j.1600-0668.2002.01128.x","article-title":"The effect of structures on indoor humidity-possibility to improve comfort and perceived air quality","volume":"12","author":"Simonson","year":"2002","journal-title":"Indoor Air"},{"key":"2021042911565294700_bib44","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.buildenv.2008.05.002","article-title":"Modelling indoor air and hygrothermal wall interaction in building simulation: Comparison between CFD and a well-mixed zonal model","volume":"44","author":"Steeman","year":"2009","journal-title":"Building and Environment"},{"issue":"4","key":"2021042911565294700_bib45","doi-asserted-by":"crossref","first-page":"28","DOI":"10.2478\/mmce-2014-0020","article-title":"Appropriate CFD turbulence model for improving indoor air quality of ventilated spaces","volume":"10","author":"Teodosiu","year":"2014","journal-title":"Mathematical Modeling in Civil Engineering"},{"key":"2021042911565294700_bib46","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1016\/j.buildenv.2005.04.026","article-title":"The effect of material choice on the total energy need and recycling potential of a building","volume":"41","author":"Thormark","year":"2006","journal-title":"Building and Environment"},{"key":"2021042911565294700_bib14","doi-asserted-by":"crossref","first-page":"9088","DOI":"10.3390\/su7079088","article-title":"CFD analysis of convective heat transfer coefficient on external surfaces of buildings","volume":"7","author":"","year":"2015","journal-title":"Sustainability"},{"key":"2021042911565294700_bib47","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1080\/10789669.2009.10390881","article-title":"Assessment of various turbulence models for transitional flows in an enclosed environment (rp-1271)","volume":"15","author":"Wang","year":"2009","journal-title":"HVAC&R Research"},{"key":"2021042911565294700_bib48","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.enbuild.2010.09.031","article-title":"Experimental study on thermal behavior of a building structure using rubberized exterior-walls","volume":"43","author":"Yesilata","year":"2011","journal-title":"Energy and Buildings"},{"issue":"4","key":"2021042911565294700_bib49","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1177\/1420326X06067336","article-title":"Application of computational fluid dynamics in building design: Aspects and trends","volume":"15","author":"Zhai","year":"2006","journal-title":"Indoor Built and Environment"}],"container-title":["Journal of Computational Design and Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/jcde\/article-pdf\/8\/2\/773\/37562345\/qwab013.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/jcde\/article-pdf\/8\/2\/773\/37562345\/qwab013.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,21]],"date-time":"2023-10-21T07:16:47Z","timestamp":1697872607000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jcde\/article\/8\/2\/773\/6168513"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,11]]},"references-count":49,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,4,28]]}},"URL":"https:\/\/doi.org\/10.1093\/jcde\/qwab013","relation":{},"ISSN":["2288-5048"],"issn-type":[{"type":"electronic","value":"2288-5048"}],"subject":[],"published-other":{"date-parts":[[2021,4]]},"published":{"date-parts":[[2021,3,11]]}}}