{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T21:09:35Z","timestamp":1766178575799,"version":"3.37.3"},"reference-count":29,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[2021,10,23]],"date-time":"2021-10-23T00:00:00Z","timestamp":1634947200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003693","name":"KIST","doi-asserted-by":"publisher","award":["2E31072"],"award-info":[{"award-number":["2E31072"]}],"id":[{"id":"10.13039\/501100003693","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,10,23]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Robot-assisted surgery has been extensively applied in various microsurgical disciplines owing to its enhanced accuracy and dexterity based on the motion-scaling function between a hand and a surgical instrument. However, the surgical robot system developed thus far incurs high manufacturing costs and restricted compatibility due to the complicated control system, including many actuators and sensors. This paper proposes a novel passive mechanism for motion scaling based on the pantograph structure to resolve these drawbacks of robotic assistance devices. As a first step, a design configuration featuring gravity compensation and the duplication of directional motion is suggested. Subsequently, the geometric dimensions required to satisfy the surgical space and structural constraints are defined. Moreover, the mass of elements required to enable gravity compensation is calculated using moment equations. After determining the principal design parameters, the motion scaling of the proposed passive model is identified using a three-dimensional computer-aided design. In addition, for an extremely precise operation in microsurgery, the dynamic reaction force is expected to be constant in any location. Therefore, to investigate dynamic dexterity, the mathematical model is formulated based on the Lagrangian dynamic equation. Then, the dynamic workspace range is analysed from the determinant of the mass matrix. In addition, the analysis results are evaluated through comparative simulations in different workspace ranges; hence, a constant reaction force can be achieved only in the dynamic workspace range.<\/jats:p>","DOI":"10.1093\/jcde\/qwab056","type":"journal-article","created":{"date-parts":[[2021,9,16]],"date-time":"2021-09-16T07:12:30Z","timestamp":1631776350000},"page":"1446-1467","source":"Crossref","is-referenced-by-count":7,"title":["Computational design and workspace analysis of a passive motion-scaling mechanism based on pantograph for microsurgery"],"prefix":"10.1093","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4151-6647","authenticated-orcid":false,"given":"Tae-Hoon","family":"Lee","sequence":"first","affiliation":[{"name":"Center for Healthcare Robotics, Korea Institute of Science and Technology, Hwarangno 14-Gil 5, Seongbuk-gu, Seoul 02792, South Korea"}]},{"given":"Dongeun","family":"Choi","sequence":"additional","affiliation":[{"name":"Center for Healthcare Robotics, Korea Institute of Science and Technology, Hwarangno 14-Gil 5, Seongbuk-gu, Seoul 02792, South Korea"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1813-9348","authenticated-orcid":false,"given":"Woosub","family":"Lee","sequence":"additional","affiliation":[{"name":"Center for Healthcare Robotics, Korea Institute of Science and Technology, Hwarangno 14-Gil 5, Seongbuk-gu, Seoul 02792, South Korea"},{"name":"Division of Nano & Information Technology, KIST School, University of Science and Technology, Gajeong-ro 217, Yuseong-gu, Daejeon 34113, South Korea"}]}],"member":"286","published-online":{"date-parts":[[2021,10,23]]},"reference":[{"issue":"1","key":"2021102311534396400_bib1","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1097\/IAE.0b013e318068de46","article-title":"Feasibility study of intraocular robotic surgery with the da Vinci surgical system","volume":"28","author":"Bourla","year":"2008","journal-title":"Retina"},{"issue":"3","key":"2021102311534396400_bib2","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1016\/S0003-4975(00)01738-0","article-title":"A comparison of robot-assisted versus manually constructed endoscopic coronary anastomosis","volume":"70","author":"Boyd","year":"2000","journal-title":"The Annals of Thoracic Surgery"},{"issue":"2","key":"2021102311534396400_bib3","doi-asserted-by":"crossref","first-page":"021001","DOI":"10.1115\/1.3046125","article-title":"Pantopteron: A new fully decoupled 3DOF translational parallel robot for pick-and-place applications","volume":"1","author":"Briot","year":"2009","journal-title":"Journal of Mechanisms and Robotics"},{"issue":"5","key":"2021102311534396400_bib4","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.mechmachtheory.2009.07.007","article-title":"Pantopteron-4: A new 3T1R decoupled parallel manipulator for pick-and-place applications","volume":"45","author":"Briot","year":"2010","journal-title":"Mechanism and Machine Theory"},{"issue":"2","key":"2021102311534396400_bib5","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.surg.2004.05.002","article-title":"Optimizing motion scaling and magnification in robotic surgery","volume":"136","author":"Cassilly","year":"2004","journal-title":"Surgery"},{"issue":"2","key":"2021102311534396400_bib6","doi-asserted-by":"crossref","first-page":"021006","DOI":"10.1115\/1.4043017","article-title":"Design and modeling of a three-degree-of-freedom articulating robotic microsurgical forceps for trans-oral laser microsurgery","volume":"13","author":"Chauhan","year":"2019","journal-title":"Journal of Medical Devices"},{"volume-title":"Introduction to robotics: Mechanics and control, 3\/E","year":"2009","author":"Craig","key":"2021102311534396400_bib7"},{"issue":"1","key":"2021102311534396400_bib8","doi-asserted-by":"crossref","first-page":"15","DOI":"10.3109\/10929089909148155","article-title":"Evaluation of a telerobotic system to assist surgeons in microsurgery","volume":"4","author":"Das","year":"1999","journal-title":"Computer Aided Surgery"},{"issue":"1","key":"2021102311534396400_bib9","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1007\/s10846-016-0452-y","article-title":"Design and analysis of a novel 3d decoupled manipulator based on compliant pantograph for micromanipulation","volume":"87","author":"Elgammal","year":"2017","journal-title":"Journal of Intelligent & Robotic Systems"},{"issue":"1","key":"2021102311534396400_bib11","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1097\/01.sla.0000103020.19595.7d","article-title":"Robotic surgery: A current perspective","volume":"239","author":"Lanfranco","year":"2004","journal-title":"Annals of Surgery"},{"issue":"1","key":"2021102311534396400_bib12","doi-asserted-by":"crossref","first-page":"014501","DOI":"10.1115\/1.4031804","article-title":"Type synthesis of 1R1T remote center of motion mechanisms based on pantograph mechanisms","volume":"138","author":"Long","year":"2016","journal-title":"Journal of Mechanical Design"},{"issue":"2","key":"2021102311534396400_bib15","doi-asserted-by":"crossref","first-page":"189","DOI":"10.4103\/aja.aja_45_17","article-title":"A retrospective review of single-institution outcomes with robotic-assisted microsurgical varicocelectomy","volume":"20","author":"McCullough","year":"2018","journal-title":"Asian Journal of Andrology"},{"issue":"3","key":"2021102311534396400_bib13","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1002\/rcs.1679","article-title":"Quantifying workspace and forces of surgical dissection during robot-assisted neurosurgery","volume":"12","author":"Maddahi","year":"2016","journal-title":"The International Journal of Medical Robotics and Computer Assisted Surgery"},{"key":"2021102311534396400_bib14","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.mechmachtheory.2017.07.010","article-title":"Kinematic design and novel mobility analysis of a new 3d pantograph decoupled manipulator","volume":"117","author":"Magdy","year":"2017","journal-title":"Mechanism and Machine Theory"},{"volume-title":"Product catalog of aluminum frames 15mm square","year":"2021","author":"MISUMI Corporation","key":"2021102311534396400_bib16"},{"issue":"6","key":"2021102311534396400_bib17","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1016\/j.jamcollsurg.2004.08.027","article-title":"Surgical robotics: Impact of motion scaling on task performance","volume":"199","author":"Prasad","year":"2004","journal-title":"Journal of the American College of Surgeons"},{"issue":"5","key":"2021102311534396400_bib18","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1002\/micr.22111","article-title":"Assessment of microsurgery competency-where are we now?","volume":"33","author":"Ramachandran","year":"2013","journal-title":"Microsurgery"},{"issue":"2","key":"2021102311534396400_bib19","first-page":"99","article-title":"Robot-assisted neurosurgery","volume":"11","author":"Rizun","year":"2004","journal-title":"In Seminars in Laparoscopic Surgery"},{"issue":"8","key":"2021102311534396400_bib20","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1136\/bjophthalmol-2018-313318","article-title":"Robot-assisted tremor control for performance enhancement of retinal microsurgeons","volume":"103","author":"Roizenblatt","year":"2019","journal-title":"British Journal of Ophthalmology"},{"key":"2021102311534396400_bib21","first-page":"789","article-title":"Performance measurement in scaled teleoperation for microsurgery","volume-title":"First Joint Conference Computer Vision, Virtual Reality and Robotics in Medicine and Medical Robotics and Computer-Assisted Surgery (CVRMed-MRCAS\u201997)","author":"Salcudean","year":"1997"},{"issue":"4","key":"2021102311534396400_bib22","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/0094-114X(87)90021-8","article-title":"Motion study of two-and three-dimensional pantograph mechanisms","volume":"22","author":"Song","year":"1987","journal-title":"Mechanism and Machine Theory"},{"issue":"1","key":"2021102311534396400_bib23","first-page":"69","article-title":"The mechanical efficiency and kinematics of pantograph-type manipulators","volume":"2","author":"Song","year":"1988","journal-title":"Journal of Mechanical Science and Technology"},{"issue":"22","key":"2021102311534396400_bib24","first-page":"1","article-title":"Current limitations of surgical robotics in reconstructive plastic microsurgery","volume":"5","author":"Tan","year":"2018","journal-title":"Frontiers in Surgery"},{"key":"2021102311534396400_bib25","first-page":"15","article-title":"Synthesis method for linkages with center of mass at invariant link point-pantograph based mechanisms","volume":"48","author":"van\u00a0der\u00a0Wijk","year":"2012","journal-title":"Mechanism and Machine Theory"},{"issue":"5","key":"2021102311534396400_bib26","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1002\/jso.25195","article-title":"Robotic (super) microsurgery: Feasibility of a new master-slave platform in an in vivo animal model and future directions","volume":"118","author":"van\u00a0Mulken","year":"2018","journal-title":"Journal of Surgical Oncology"},{"issue":"1","key":"2021102311534396400_bib27","first-page":"1","article-title":"First-in-human robotic supermicrosurgery using a dedicated microsurgical robot for treating breast cancer-related lymphedema: A randomized pilot trial","volume":"11","author":"van\u00a0Mulken","year":"2020","journal-title":"Nature Communications"},{"issue":"2","key":"2021102311534396400_bib10","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/0094-114X(85)90017-5","article-title":"Pantograph mechanism as a non-traditional manipulator structure","volume":"20","author":"Yang","year":"1985","journal-title":"Mechanism and Machine Theory"},{"volume-title":"World's first clinically available microsurgical robotic system: Super-microsurgery with robot hands","year":"2020","author":"YouTube","key":"2021102311534396400_bib28"},{"issue":"1","key":"2021102311534396400_bib29","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/s11548-019-02074-1","article-title":"A microsurgical robot research platform for robot-assisted microsurgery research and training","volume":"15","author":"Zhang","year":"2020","journal-title":"International Journal of Computer Assisted Radiology and Surgery"}],"container-title":["Journal of Computational Design and Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/jcde\/article-pdf\/8\/6\/1446\/40830683\/qwab056.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/jcde\/article-pdf\/8\/6\/1446\/40830683\/qwab056.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,23]],"date-time":"2021-10-23T07:54:16Z","timestamp":1634975656000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jcde\/article\/8\/6\/1446\/6409165"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,23]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,10,23]]}},"URL":"https:\/\/doi.org\/10.1093\/jcde\/qwab056","relation":{},"ISSN":["2288-5048"],"issn-type":[{"type":"electronic","value":"2288-5048"}],"subject":[],"published-other":{"date-parts":[[2021,12]]},"published":{"date-parts":[[2021,10,23]]}}}