{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T07:53:54Z","timestamp":1770710034589,"version":"3.49.0"},"reference-count":38,"publisher":"Oxford University Press (OUP)","issue":"5","license":[{"start":{"date-parts":[[2022,7,29]],"date-time":"2022-07-29T00:00:00Z","timestamp":1659052800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"Seoul R &BD","award":["CT210006"],"award-info":[{"award-number":["CT210006"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,9,8]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This study analyzed the effects of implant design factors (diameter, length, and connection type) and bone quality on the long-term success of implantation via finite element (FE) analysis, considering the bone remodeling process. A total of 36 cases of the three-dimensional FE model, with an implant complex located in the mandibular bone section of the molar region, were considered. An FE analysis considering dental bone remodeling was implemented in the Abaqus UMAT subroutine. A preload of 32 N\u2219cm and an average biting force of 50 N were applied during the bone remodeling process as the loading conditions. After the bone remodeling process, a maximum biting force of 200 N was applied in the oblique direction. The stability of the peri-implant bone was analyzed by measuring the apparent bone density over time and the principal strain in the cancellous bone. The stability of the peri-implant bone differs depending on the host bone conditions and implant design features. The initial bone condition greatly influenced the final density and maximum principal strain distribution in the cancellous bone surrounding the implant. The need for a stability evaluation considering the bone remodeling process has increased under the conditions of placing short-length and narrow-diameter implants in poor-quality bones.<\/jats:p>","DOI":"10.1093\/jcde\/qwac069","type":"journal-article","created":{"date-parts":[[2022,7,29]],"date-time":"2022-07-29T12:39:12Z","timestamp":1659098352000},"page":"1538-1548","source":"Crossref","is-referenced-by-count":10,"title":["Biomechanical effects of bone quality and design features in dental implants in long-term bone stability"],"prefix":"10.1093","volume":"9","author":[{"given":"Jieun","family":"Park","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering, Korea University , Seoul 02841, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Soyeon","family":"Park","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Korea University , Seoul 02841, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Inyeong","family":"Kang","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Korea University , Seoul 02841, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4817-7932","authenticated-orcid":false,"given":"Gunwoo","family":"Noh","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Korea University , Seoul 02841, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2022,7,29]]},"reference":[{"key":"2022110904480979700_bib1","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1093\/jcde\/qwaa069","article-title":"Size optimization methods to approximate equivalent mechanical behaviour in thermoplastics","volume":"8","author":"Althammer","year":"2021","journal-title":"Journal of Computational Design and Engineering"},{"key":"2022110904480979700_bib5","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1093\/jcde\/qwaa053","article-title":"Design and numerical investigation of an adaptive intramedullary nail with a novel interlocking mechanism","volume":"7","author":"Bagheri","year":"2020","journal-title":"Journal of Computational Design and Engineering"},{"key":"2022110904480979700_bib2","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1046\/j.1365-2842.1998.00318.x","article-title":"Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog","volume":"25","author":"Barbier","year":"1998","journal-title":"Journal of Oral Rehabilitation"},{"key":"2022110904480979700_bib3","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1007\/s10237-010-0274-y","article-title":"Modeling of bone adaptative behavior based on cells activities","volume":"10","author":"Bonfoh","year":"2011","journal-title":"Biomechanics and Modeling in Mechanobiology"},{"key":"2022110904480979700_bib4","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1016\/j.jcms.2013.12.005","article-title":"The biomechanical aspects of reconstruction for segmental defects of the mandible: A finite element study to assess the optimisation of plate and screw factors","volume":"42","author":"Bujt\u00e1r","year":"2014","journal-title":"Journal of Cranio-Maxillofacial Surgery"},{"key":"2022110904480979700_bib6","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.jcde.2018.01.001","article-title":"Towards a CAD-based automatic procedure for patient specific cutting guides to assist sternal osteotomies in pectus arcuatum surgical correction","volume":"6","author":"Carfagni","year":"2019","journal-title":"Journal of Computational Design and Engineering"},{"key":"2022110904480979700_bib7","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1016\/j.medengphy.2006.10.017","article-title":"Biomechanical study of a prosthetic solution based on an angled abutment: Case of upper lateral incisor","volume":"29","author":"Dubois","year":"2007","journal-title":"Medical Engineering & Physics"},{"key":"2022110904480979700_bib8","doi-asserted-by":"crossref","first-page":"186","DOI":"10.4103\/1305-7456.208432","article-title":"New dental implant selection criterion based on implant design","volume":"11","author":"El-Anwar","year":"2017","journal-title":"European Journal of Dentistry"},{"key":"2022110904480979700_bib9","first-page":"73","article-title":"The mechanostat: a proposed pathogenic mechanism of osteoporoses and the bone mass effects of mechanical and non mechanical agents","volume":"2","author":"Frost","year":"1987","journal-title":"Bone and Mineral"},{"key":"2022110904480979700_bib10","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1093\/jcde\/qwab048","article-title":"Design of wood-like metallic material using metal sheet architecture","volume":"8","author":"Han","year":"2021","journal-title":"Journal of Computational Design and Engineering"},{"key":"2022110904480979700_bib11","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1556\/imas.5.2013.4.3","article-title":"Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation","volume":"5","author":"Javed","year":"2013","journal-title":"Interventional Medicine and Applied Science"},{"key":"2022110904480979700_bib12","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.msec.2016.02.061","article-title":"Finite element analysis on influence of implant surface treatments, connection and bone types","volume":"63","author":"Junior","year":"2016","journal-title":"Materials Science and Engineering: C"},{"key":"2022110904480979700_bib14","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1093\/jcde\/qwab008","article-title":"A quasi-3D model of the whole lung: airway extension to the tracheobronchial limit using the constrained constructive optimization and alveolar modeling, using a sac\u2013trumpet model","volume":"8","author":"Kannan","year":"2021","journal-title":"Journal of Computational Design and Engineering"},{"key":"2022110904480979700_bib13","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/S8756-3282(03)00157-1","article-title":"Mathematical model predicts a critical role for osteoclast autocrine regulation in the control of bone remodeling","volume":"33","author":"Komarova","year":"2003","journal-title":"Bone"},{"key":"2022110904480979700_bib16","doi-asserted-by":"crossref","first-page":"341","DOI":"10.4047\/jap.2019.11.6.341","article-title":"Effects of cementless fixation of implant prosthesis: A finite element study","volume":"11","author":"Lee","year":"2019","journal-title":"The Journal of Advanced Prosthodontics"},{"key":"2022110904480979700_bib17","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.prosdent.2018.07.013","article-title":"Biomechanical analysis of 4 types of short dental implants in a resorbed mandible","volume":"121","author":"Lee","year":"2019","journal-title":"The Journal of Prosthetic Dentistry"},{"key":"2022110904480979700_bib18","doi-asserted-by":"crossref","first-page":"105863","DOI":"10.1016\/j.cmpb.2020.105863","article-title":"Biomechanical effects of dental implant diameter, connection type, and bone density on microgap formation and fatigue failure: A finite element analysis","volume":"200","author":"Lee","year":"2021","journal-title":"Computer Methods and Programs in Biomedicine"},{"key":"2022110904480979700_bib19","article-title":"Effects of implant diameter, implant-abutment connection type and bone density on the biomechanical stability of implant components and bone: A finite element analysis study","author":"Lee","year":"2021","journal-title":"The Journal of Prosthetic Dentistry"},{"key":"2022110904480979700_bib20","first-page":"199","article-title":"Patient selection and preparation","volume-title":"Tissue-integrated prosthesis: Osseointegration in clinical dentistry","author":"Lekholm","year":"1985"},{"key":"2022110904480979700_bib21","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1016\/j.jmbbm.2008.11.007","article-title":"Dental implant induced bone remodeling and associated algorithms","volume":"2","author":"Lin","year":"2009","journal-title":"Journal of the Mechanical Behavior of Biomedical Materials"},{"key":"2022110904480979700_bib22","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/S0921-5093(97)00806-X","article-title":"Mechanical properties of biomedical titanium alloys","volume":"243","author":"Niinomi","year":"1998","journal-title":"Materials Science and Engineering: A"},{"key":"2022110904480979700_bib23","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1590\/S0103-64402010000600001","article-title":"Influence of implant surfaces on osseointegration","volume":"21","author":"Novaes","year":"2010","journal-title":"Brazilian Dental Journal"},{"key":"2022110904480979700_bib25","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1016\/j.prosdent.2019.05.023","article-title":"Designing a mandibular advancement device with topology optimization for a partially edentulous patient","volume":"123","author":"Park","year":"2019","journal-title":"The Journal of Prosthetic Dentistry"},{"issue":"5","key":"2022110904480979700_bib27","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1093\/jcde\/qwab047","article-title":"Design process of patient-specific osteosynthesis plates using topology optimization","volume":"8","author":"Park","year":"2021","journal-title":"Journal of Computational Design and Engineering"},{"key":"2022110904480979700_bib26","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1093\/jcde\/qwaa067","article-title":"Implant placement in the removable mandibular advancement device for completely edentulous patients: A finite element study","volume":"8","author":"Park","year":"2021","journal-title":"Journal of Computational Design and Engineering"},{"key":"2022110904480979700_bib28","doi-asserted-by":"crossref","first-page":"106852","DOI":"10.1016\/j.cmpb.2022.106852","article-title":"Effects of assessing the bone remodeling process in biomechanical finite element stability evaluations of dental implants","volume":"221","author":"Park","year":"2022","journal-title":"Computer Methods and Programs in Biomedicine"},{"key":"2022110904480979700_bib24","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1563\/AAID-JOI-D-11-00138","article-title":"Photoelastic analysis of stress distribution with different implant systems","volume":"40","author":"Pellizzer","year":"2014","journal-title":"Journal of Oral Implantology"},{"key":"2022110904480979700_bib29","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1111\/j.1532-849X.1994.tb00124.x","article-title":"Cantilever and implant biomechanics: A review of the literature, part 1","volume":"3","author":"Rodriguez","year":"1994","journal-title":"Journal of Prosthodontics"},{"key":"2022110904480979700_bib32","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1177\/0022034513504782","article-title":"Comparison of long-term survival of implants and endodontically treated teeth","volume":"93","author":"Setzer","year":"2014","journal-title":"Journal of Dental Research"},{"key":"2022110904480979700_bib31","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/01.ID.0000091140.76130.A1","article-title":"Dental implant design and its relationship to long-term implant success","volume":"12","author":"Steigenga","year":"2003","journal-title":"Implant Dentistry"},{"key":"2022110904480979700_bib36","doi-asserted-by":"crossref","first-page":"106365","DOI":"10.1016\/j.cmpb.2021.106365","article-title":"Modeling the musculoskeletal loading in bone remodeling at the hip of a child","volume":"210","author":"Terryn","year":"2021","journal-title":"Computer Methods and Programs in Biomedicine"},{"key":"2022110904480979700_bib35","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jmbbm.2011.10.002","article-title":"Dynamic and static mechanical analysis of resin luting cements","volume":"6","author":"Tolidis","year":"2012","journal-title":"Journal of the Mechanical Behavior of Biomedical Materials"},{"key":"2022110904480979700_bib33","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1097\/01.id.0000239333.24384.5d","article-title":"Dental implant success-failure analysis: A concept of implant vulnerability","volume":"15","author":"Tolstunov","year":"2006","journal-title":"Implant Dentistry"},{"key":"2022110904480979700_bib34","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1472-6831-8-32","article-title":"Influence of bone density on implant stability parameters and implant success: A retrospective clinical study","volume":"8","author":"Turkyilmaz","year":"2008","journal-title":"BMC Oral Health"},{"key":"2022110904480979700_bib37","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1002\/jab.770060408","article-title":"Finite element analysis of crestal bone loss around porous-coated dental implants","volume":"6","author":"Vaillancourt","year":"1995","journal-title":"Journal of Applied Biomaterials"},{"key":"2022110904480979700_bib38","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/S0022-3913(09)60079-2","article-title":"The dynamic natures of implant loading","volume":"101","author":"Wang","year":"2009","journal-title":"The Journal of Prosthetic Dentistry"},{"key":"2022110904480979700_bib40","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1093\/jcde\/qwaa096","article-title":"Effect of mandibular contouring surgery on the stress distribution during various clenching tasks","volume":"8","author":"Yoon","year":"2021","journal-title":"Journal of Computational Design and Engineering"},{"key":"2022110904480979700_bib39","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/S0109-5641(98)00007-4","article-title":"Design of prosthetic cantilever bridgework supported by osseointegrated implants using the finite element method","volume":"14","author":"Young","year":"1998","journal-title":"Dental Materials"}],"container-title":["Journal of Computational Design and Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jcde\/advance-article-pdf\/doi\/10.1093\/jcde\/qwac069\/45186482\/qwac069.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jcde\/article-pdf\/9\/5\/1538\/46878017\/qwac069.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jcde\/article-pdf\/9\/5\/1538\/46878017\/qwac069.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,9]],"date-time":"2022-11-09T04:48:40Z","timestamp":1667969320000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jcde\/article\/9\/5\/1538\/6651688"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,29]]},"references-count":38,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,9,8]]}},"URL":"https:\/\/doi.org\/10.1093\/jcde\/qwac069","relation":{},"ISSN":["2288-5048"],"issn-type":[{"value":"2288-5048","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2022,10]]},"published":{"date-parts":[[2022,7,29]]}}}