{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T08:28:06Z","timestamp":1772180886650,"version":"3.50.1"},"reference-count":19,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T00:00:00Z","timestamp":1770595200000},"content-version":"vor","delay-in-days":8,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52477009"],"award-info":[{"award-number":["52477009"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52577249"],"award-info":[{"award-number":["52577249"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,2,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Real-time nuclear magnetic resonance (NMR) logging-while-drilling (LWD) is critical for reservoir evaluation. The magnet system, as the core of the NMR-LWD sensor, directly influences signal quality and measurement temperature stability. However, traditional magnet system design methods are based on empirical structures and size optimization, making it difficult to obtain a novel and excellent magnet system. This study proposed a novel shape optimization method via B-spline boundaries and mesh deformation. First, the boundaries of the magnet system are controlled by the B-spline curves to present more novel structures. To improve the efficiency of finite element analysis (FEA) and guarantee a seamless optimization, the radial basis function-based mesh deformation method is applied to obtain the mesh for different shapes without time-consuming remeshing. Finally, the multi-objective optimization is conducted. The performance of some typical Pareto solutions is evaluated and compared with that from traditional size optimization based on FEA. It is found that the proposed shape optimization yields a magnet system that is superior to its size optimization counterpart, providing a 10% stronger magnetic field and 56% better stability in signal strength against temperature variations.<\/jats:p>","DOI":"10.1093\/jcde\/qwag012","type":"journal-article","created":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T12:46:31Z","timestamp":1770381991000},"page":"229-238","source":"Crossref","is-referenced-by-count":0,"title":["Shape optimization of magnet system for NMR logging-while-drilling sensor via B-spline boundaries and mesh deformation"],"prefix":"10.1093","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9204-5702","authenticated-orcid":false,"given":"Xianneng","family":"Xu","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, Tsinghua University , Beijing 100084 ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3968-414X","authenticated-orcid":false,"given":"Zheng","family":"Xu","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Chongqing University , Chongqing 400044 ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanzuo","family":"Song","sequence":"additional","affiliation":[{"name":"China Oilfield Services Limited, Well-Tech Research and Development Institute , Beijing 101149 ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5637-834X","authenticated-orcid":false,"given":"Jun","family":"Zou","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Tsinghua University , Beijing 100084 ,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2026,2,9]]},"reference":[{"key":"2026022702164535700_bib1","doi-asserted-by":"publisher","first-page":"6645","DOI":"10.1109\/TIA.2023.3298869","article-title":"Hybrid excited permanent magnet motor: analytical sizing, finite element analysis and tests","volume":"59","author":"Cinti","year":"2023","journal-title":"IEEE Transactions on Industry Applications"},{"key":"2026022702164535700_bib2","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1109\/4235.996017","article-title":"A fast and elitist multiobjective genetic algorithm: NSGA-II","volume":"6","author":"Deb","year":"2002","journal-title":"IEEE Transactions on Evolutionary Computation"},{"key":"2026022702164535700_bib3","doi-asserted-by":"publisher","first-page":"2747","DOI":"10.1007\/s13202-022-01476-3","article-title":"A review on the applications of nuclear magnetic resonance (NMR) in the oil and gas industry: laboratory and field-scale measurements","volume":"12","author":"Elsayed","year":"2022","journal-title":"Journal of Petroleum Exploration and Production Technology"},{"key":"2026022702164535700_bib4","doi-asserted-by":"publisher","first-page":"2587","DOI":"10.1109\/TMTT.2024.3487573","article-title":"Efficient mesh space mapping optimization for tunable filters incorporating structurally simplified coarse mesh model without tunable elements","volume":"73","author":"Feng","year":"2025","journal-title":"IEEE Transactions on Microwave Theory and Techniques"},{"key":"2026022702164535700_bib5","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1002\/nme.2579","article-title":"Gmsh: A 3-D finite element mesh generator with built-in pre- and post-processing facilities","volume":"79","author":"Geuzaine","year":"2009","journal-title":"International Journal for Numerical Methods in Engineering"},{"key":"2026022702164535700_bib6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2022.3227991","article-title":"A temperature stable inside-out NMR sensor","volume":"72","author":"Han","year":"2023","journal-title":"IEEE Transactions on Instrumentation and Measurement"},{"key":"2026022702164535700_bib7","doi-asserted-by":"publisher","first-page":"20240054","DOI":"10.1515\/nleng-2024-0054","article-title":"B-spline curve theory: An overview and applications in real life","volume":"13","author":"Hasan","year":"2024","journal-title":"Nonlinear Engineering"},{"key":"2026022702164535700_bib8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TMAG.2019.2896623","article-title":"Mesh deformation based on radial basis function interpolation applied to low-frequency electromagnetic problem","volume":"55","author":"Henneron","year":"2019","journal-title":"IEEE Transactions on Magnetics"},{"key":"2026022702164535700_bib9","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1093\/jcde\/qwac129","article-title":"Intuitive approach for design of inner structure by mimicking magnetic effect","volume":"10","author":"Kam","year":"2023","journal-title":"Journal of Computational Design and Engineering"},{"key":"2026022702164535700_bib10","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1093\/jcde\/qwae085","article-title":"Automatic cable routing based on improved pathfinding algorithm and b-spline optimization for collision avoidance","volume":"11","author":"Kim","year":"2024","journal-title":"Journal of Computational Design and Engineering"},{"key":"2026022702164535700_bib11","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1093\/jcde\/qwae102","article-title":"BMO-GNN: Bayesian mesh optimization for graph neural networks to enhance engineering performance prediction","volume":"11","author":"Park","year":"2024","journal-title":"Journal of Computational Design and Engineering"},{"key":"2026022702164535700_bib12","doi-asserted-by":"publisher","first-page":"1744","DOI":"10.1109\/TEMC.2023.3311632","article-title":"SIMP-method topology optimization of ferrite structures in inductive power transfer systems","volume":"65","author":"Pei","year":"2023","journal-title":"IEEE Transactions on Electromagnetic Compatibility"},{"key":"2026022702164535700_bib13","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-031-01689-9","volume-title":"Introduction to the Finite Element Method in Electromagnetics, Synthesis Lectures on Computational Electromagnetics","author":"Polycarpou","year":"2006"},{"key":"2026022702164535700_bib14","doi-asserted-by":"publisher","first-page":"8276","DOI":"10.1109\/TIE.2023.3234129","article-title":"Investigation of rotor topologies for reducing torque ripple in double-layer IPMSMs for automotive applications","volume":"70","author":"Shimizu","year":"2023","journal-title":"IEEE Transactions on Industrial Electronics"},{"key":"2026022702164535700_bib15","doi-asserted-by":"publisher","first-page":"107082","DOI":"10.1016\/j.jmr.2021.107082","article-title":"Inside-out NMR with two concentric ring magnets","volume":"333","author":"Utsuzawa","year":"2021","journal-title":"Journal of Magnetic Resonance"},{"key":"2026022702164535700_bib16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TGRS.2023.3268727","article-title":"Modeling and analysis of litz wire radio frequency (RF) coil in inside-out NMR well logging sensor","volume":"61","author":"Xu","year":"2023","journal-title":"IEEE Transactions on Geoscience and Remote Sensing"},{"key":"2026022702164535700_bib17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/JSEN.2024.3416625","article-title":"Topology optimization based design of magnet system in unilateral nmr logging sensor considering coil efficiency","volume":"24","author":"Xu","year":"2024","journal-title":"IEEE Sensors Journal"},{"key":"2026022702164535700_bib18","doi-asserted-by":"publisher","first-page":"100085","DOI":"10.1016\/j.mrl.2023.06.002","article-title":"A study on the temperature sensitivity of NMR porosity in porous media based on the intensity of magnetization","volume":"4","author":"Zhang","year":"2024","journal-title":"Magnetic Resonance Letters"},{"key":"2026022702164535700_bib19","doi-asserted-by":"publisher","first-page":"3760","DOI":"10.1002\/mp.17856","article-title":"Design simulation of high-homogeneity portable MRI magnet array using global optimization algorithm and equivalent currents model","volume":"52","author":"Zhou","year":"2025","journal-title":"Medical Physics"}],"container-title":["Journal of Computational Design and Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/jcde\/advance-article-pdf\/doi\/10.1093\/jcde\/qwag012\/66820572\/qwag012.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jcde\/article-pdf\/13\/2\/229\/66820572\/qwag012.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jcde\/article-pdf\/13\/2\/229\/66820572\/qwag012.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T07:16:54Z","timestamp":1772176614000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jcde\/article\/13\/2\/229\/8469371"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2,5]]}},"URL":"https:\/\/doi.org\/10.1093\/jcde\/qwag012","relation":{},"ISSN":["2288-5048"],"issn-type":[{"value":"2288-5048","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,2]]},"published":{"date-parts":[[2026,2]]}}}