{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,17]],"date-time":"2026-05-17T01:10:50Z","timestamp":1778980250929,"version":"3.51.4"},"reference-count":52,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2020,9,15]],"date-time":"2020-09-15T00:00:00Z","timestamp":1600128000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,1,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Filtering facepiece respirators (FFRs) are made for one-time use. A massive shortage of FFRs is widespread during pandemic events and has forced many healthcare organizations to decontaminate them and re-use for a limited time. Many decontamination methods have been proposed for the decontamination of FFRs. This review highlights various aspects of decontamination methods available in the literature. Among various methods available, vaporized hydrogen peroxide, ultraviolet irradiation, and dry heat seem to be the most promising decontaminants for FFRs. On the other hand, microwave, bleach, ethylene oxide, alcohol, hydrogen peroxide liquid, sanitizing wipes, and soap and water are not recommended methods for FFR decontamination.<\/jats:p>","DOI":"10.1093\/annweh\/wxaa090","type":"journal-article","created":{"date-parts":[[2020,8,12]],"date-time":"2020-08-12T19:31:30Z","timestamp":1597260690000},"page":"26-52","source":"Crossref","is-referenced-by-count":7,"title":["Decontamination Strategies for Filtering Facepiece Respirators (FFRs) in Healthcare Organizations: A Comprehensive Review"],"prefix":"10.1093","volume":"65","author":[{"given":"Ashok Kumar","family":"Jena","sequence":"first","affiliation":[{"name":"Department of Dentistry, All India Institute of Medical Sciences, Sijua, Dumduma, Bhubaneswar, Khorda, Odisha, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jitendra","family":"Sharan","sequence":"additional","affiliation":[{"name":"Department of Dentistry, All India Institute of Medical Sciences, Sijua, Dumduma, Bhubaneswar, Khorda, Odisha, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2020,9,15]]},"reference":[{"key":"2021011405443029000_CIT0001","author":"3M Company","year":"2020"},{"key":"2021011405443029000_CIT0002","author":"Battelle","year":"2016"},{"key":"2021011405443029000_CIT0003","first-page":"33","article-title":"Evaluation of multiple (3-cycle) decontamination processing for filtering facepiece respirators","volume":"5","author":"Bergman","year":"2010","journal-title":"J Eng Fibers Fabrics"},{"key":"2021011405443029000_CIT0004","first-page":"48","article-title":"Impact of three cycles of decontamination treatments on filtering facepiece respirator fit","volume":"28","author":"Bergman","year":"2011","journal-title":"J Int Soc Respir Prot"},{"key":"2021011405443029000_CIT0005","first-page":"523","article-title":"Evaluation of permanently charged electrofibrous filters.","volume-title":"Proceedings of the 17th annual DOE Nuclear Air Cleaning Conference.","author":"Bierman","year":"1982"},{"key":"2021011405443029000_CIT0006","author":"Centers for Disease Control and Prevention (CDC)","year":"2008"},{"key":"2021011405443029000_CIT0007","author":"Centers for Disease Control and Prevention (CDC)","year":"2008"},{"key":"2021011405443029000_CIT0008","author":"Centers for Disease Control and Prevention (CDC)","year":"2020"},{"key":"2021011405443029000_CIT0009","author":"Centers for Disease Control and Prevention (CDC)","year":"2020"},{"key":"2021011405443029000_CIT0010","author":"Code of Federal Regulations (CFR)","year":"1995"},{"key":"2021011405443029000_CIT0011","article-title":"Analysis of SteraMist ionized hydrogen peroxide technology in the sterilization of N95 respirators and other PPE: a quality improvement study","author":"Cramer","year":"2020","journal-title":"medRxiv"},{"key":"2021011405443029000_CIT0012","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/S0039-6028(01)01297-3","article-title":"Does UV irradiation affect polymer properties relevant to tissue engineering?","volume":"491","author":"Fischbach","year":"2001","journal-title":"Surf Sci"},{"key":"2021011405443029000_CIT0013","doi-asserted-by":"crossref","first-page":"2253","DOI":"10.3201\/eid2609.201524","article-title":"Effectiveness of N95 respirator decontamination and re-use against SARS-CoV-2 virus","volume":"26","author":"Fischer","year":"2020","journal-title":"Emerg Infect Dis"},{"key":"2021011405443029000_CIT0014","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1111\/j.1365-2672.2010.04881.x","article-title":"A method to determine the available UV-C dose for the decontamination of filtering facepiece respirators","volume":"110","author":"Fisher","year":"2011","journal-title":"J Appl Microbiol"},{"key":"2021011405443029000_CIT0015","doi-asserted-by":"crossref","first-page":"e18585","DOI":"10.1371\/journal.pone.0018585","article-title":"Evaluation of microwave steam bags for the decontamination of filtering facepiece respirators","volume":"6","author":"Fisher","year":"2011","journal-title":"PLoS One"},{"key":"2021011405443029000_CIT0016","author":"Food and Drug Administration (FDA)","year":"2020"},{"key":"2021011405443029000_CIT0017","author":"Food and Drug Administration (FDA)","year":"2020"},{"key":"2021011405443029000_CIT0018","author":"Food and Drug Administration","year":"2020"},{"key":"2021011405443029000_CIT0019","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1016\/j.jhin.2020.06.030","article-title":"Autoclave sterilization and ethanol treatment of re-used surgical masks and N95 respirators during COVID-19: impact on their performance and integrity","volume":"105","author":"Grinshpun","year":"2020","journal-title":"J Hosp Infect"},{"key":"2021011405443029000_CIT0020","doi-asserted-by":"crossref","first-page":"244","DOI":"10.2307\/3579001","article-title":"Ultraviolet (193, 216 and 254 nm) photoinactivation of Escherichia coli strains with different repair deficiencies","volume":"141","author":"Gurzadyan","year":"1995","journal-title":"Radiat Res"},{"key":"2021011405443029000_CIT0021","author":"Heimbuch","year":"2020"},{"key":"2021011405443029000_CIT0022","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.ajic.2013.09.014","article-title":"Cleaning of filtering facepiece respirators contaminated with mucin and Staphylococcus aureus","volume":"42","author":"Heimbuch","year":"2014","journal-title":"Am J Infect Control"},{"key":"2021011405443029000_CIT0023","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.ajic.2010.07.004","article-title":"A pandemic influenza preparedness study: use of energetic methods to decontaminate filtering facepiece respirators contaminated with H1N1 aerosols and droplets","volume":"39","author":"Heimbuch","year":"2011","journal-title":"Am J Infect Control"},{"key":"2021011405443029000_CIT0024","first-page":"148","volume-title":"Handbook of nonwoven filter media","author":"Hutten","year":"2007"},{"key":"2021011405443029000_CIT0025","doi-asserted-by":"crossref","DOI":"10.1016\/j.ajic.2020.06.216","article-title":"Disinfection of N95 masks artificially contaminated with SARS-CoV-2 and ESKAPE bacteria using hydrogen peroxide plasma: impact on the reutilization of disposable devices","author":"Ib\u00e1\u00f1ez-Cervantes","year":"2020","journal-title":"Am J Infect Control"},{"key":"2021011405443029000_CIT0053","first-page":"92","author":"Institute of Medicine of the National Academies (IOM)","year":"2006","journal-title":"Committee on the development of reusable facemasks for use during an influenza pandemics. Reusability of facemasks during an influenza pandemic: facing the flue"},{"key":"2021011405443029000_CIT0026","first-page":"71","article-title":"Efficiency of degraded electret filters: part 1\u2014laboratory testing against NaCl and DOP before and after exposure to workplace aerosols","volume":"20","author":"Janssen","year":"2003","journal-title":"J Int Soc Respir Prot"},{"key":"2021011405443029000_CIT0027","first-page":"97","article-title":"Effect of phase of toluene on filtration performance of electret filter media against di-octyl-phthalate aerosols","volume":"22","author":"Jasper","year":"2005","journal-title":"J Int Soc Respir Prot"},{"key":"2021011405443029000_CIT0028","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1016\/j.jaerosci.2005.06.008","article-title":"Effect of xylene exposure on the performance of electret filter media","volume":"37","author":"Jasper","year":"2006","journal-title":"J Aerosol Sci"},{"key":"2021011405443029000_CIT0029","article-title":"N95 reprocessing by low temperature sterilization with 59% vaporized hydrogen peroxide during the 2020 COVID-19 pandemic","author":"Jatta","year":"2020","journal-title":"Am J Infect Control"},{"key":"2021011405443029000_CIT0030","doi-asserted-by":"crossref","first-page":"2133","DOI":"10.1128\/AEM.53.9.2133-2137.1987","article-title":"Mechanism of microwave sterilization in the dry state","volume":"53","author":"Jeng","year":"1987","journal-title":"Appl Environ Microbiol"},{"key":"2021011405443029000_CIT0031","article-title":"Hydrogen peroxide vapor sterilization of N95 respirators for re-use","author":"Kenney","year":"2020","journal-title":"medRxiv"},{"key":"2021011405443029000_CIT0032","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1111\/ina.12475","article-title":"Relative survival of Bacillus subtilis spores loaded on filtering facepiece respirators after five decontamination methods","volume":"28","author":"Lin","year":"2018","journal-title":"Indoor Air"},{"key":"2021011405443029000_CIT0033","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1080\/15459624.2015.1018518","article-title":"Effects of ultraviolet germicidal irradiation (UVGI) on N95 respirator filtration performance and structural integrity","volume":"12","author":"Lindsley","year":"2015","journal-title":"J Occup Environ Hyg"},{"key":"2021011405443029000_CIT0034","first-page":"92","article-title":"Effectiveness of three decontamination treatments against influenza virus applied to filtering facepiece respirators","volume":"56","author":"Lore","year":"2012","journal-title":"Ann Occup Hyg"},{"key":"2021011405443029000_CIT0035","author":"Lowe","year":"2020"},{"key":"2021011405443029000_CIT0036","author":"Mackenzie","year":"2020"},{"key":"2021011405443029000_CIT0037","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1080\/10473220050075617","article-title":"Electrostatic respirator filter media: filter efficiency and most penetrating particle size effects","volume":"15","author":"Martin","year":"2000","journal-title":"Appl Occup Environ Hyg"},{"key":"2021011405443029000_CIT0038","first-page":"1.34","article-title":"The use of hydrogen peroxide for disinfection and sterilization applications.","volume-title":"PATAI\u2019S chemistry of functional groups","author":"McDonnell","year":"2009"},{"key":"2021011405443029000_CIT0039","doi-asserted-by":"crossref","first-page":"e49","DOI":"10.1016\/j.ajic.2018.02.018","article-title":"Ultraviolet germicidal irradiation of influenza-contaminated N95 filtering facepiece respirators","volume":"46","author":"Mills","year":"2018","journal-title":"Am J Infect Control"},{"key":"2021011405443029000_CIT0041","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.jhin.2020.07.008","article-title":"Dry heat and microwave generated steam protocols for the rapid decontamination of respiratory personal protective equipment in response to COVID-19-related shortages","volume":"106","author":"Pascoe","year":"2020","journal-title":"J Hosp Infect"},{"key":"2021011405443029000_CIT0042","first-page":"239","volume-title":"Industrial sterilization","author":"Phillips","year":"1973"},{"key":"2021011405443029000_CIT0043","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1080\/15459624.2010.484794","article-title":"Analysis of residual chemicals on filtering facepiece respirators after decontamination","volume":"7","author":"Salter","year":"2010","journal-title":"J Occup Environ Hyg"},{"key":"2021011405443029000_CIT0044","author":"Tomimist","year":"2020"},{"key":"2021011405443029000_CIT0045","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1080\/15459620701329012","article-title":"Inactivation of viruses on surfaces by ultraviolet germicidal irradiation","volume":"4","author":"Tseng","year":"2007","journal-title":"J Occup Environ Hyg"},{"key":"2021011405443029000_CIT0046","doi-asserted-by":"crossref","first-page":"1564","DOI":"10.1056\/NEJMc2004973","article-title":"Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1","volume":"382","author":"van Doremalen","year":"2020","journal-title":"N Engl J Med"},{"key":"2021011405443029000_CIT0047","doi-asserted-by":"crossref","DOI":"10.1007\/b136268","volume-title":"Ultraviolet radiation in the solar system","author":"Vazqez","year":"2006"},{"key":"2021011405443029000_CIT0048","first-page":"815","article-title":"Evaluation of five decontamination methods for filtering facepiece respirators","volume":"53","author":"Viscusi","year":"2009","journal-title":"Ann Occup Hyg"},{"key":"2021011405443029000_CIT0049","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1080\/15459624.2011.585927","article-title":"Impact of three biological decontamination methods on filtering facepiece respirator fit, odor, comfort, and donning ease","volume":"8","author":"Viscusi","year":"2011","journal-title":"J Occup Environ Hyg"},{"key":"2021011405443029000_CIT0050","first-page":"93","article-title":"Effect of decontamination on the filtration efficiency of two filtering facepiece respirator models","volume":"24","author":"Viscusi","year":"2007","journal-title":"J Int Soc Respir Prot"},{"key":"2021011405443029000_CIT0051","article-title":"Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density","author":"Yim","year":"2020","journal-title":"medRxiv"},{"key":"2021011405443029000_CIT0052","doi-asserted-by":"crossref","first-page":"e00997-20","DOI":"10.1128\/mBio.00997-20","article-title":"Microwave-generated steam decontamination of N95 respirators utilizing universally accessible materials","volume":"11","author":"Zulauf","year":"2020","journal-title":"mBio"}],"container-title":["Annals of Work Exposures and Health"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/annweh\/article-pdf\/65\/1\/26\/35747814\/wxaa090.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/annweh\/article-pdf\/65\/1\/26\/35747814\/wxaa090.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,14]],"date-time":"2021-01-14T12:03:34Z","timestamp":1610625814000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/annweh\/article\/65\/1\/26\/5905737"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,15]]},"references-count":52,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,9,15]]},"published-print":{"date-parts":[[2021,1,14]]}},"URL":"https:\/\/doi.org\/10.1093\/annweh\/wxaa090","relation":{},"ISSN":["2398-7308","2398-7316"],"issn-type":[{"value":"2398-7308","type":"print"},{"value":"2398-7316","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,1,1]]},"published":{"date-parts":[[2020,9,15]]}}}