{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T07:25:34Z","timestamp":1784013934452,"version":"3.55.0"},"reference-count":6,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2020,4,15]],"date-time":"2020-04-15T00:00:00Z","timestamp":1586908800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title\/>\n                  <jats:p>This is a single-surgeon experience detailing the senior author\u2019s (J.G.) minimal-touch technique for placement of breast implants. Adams et al. 14-point plan has been incorporated into the technique, and the implant box paper cover sheet is used as a barrier between the patient and the implant near the incision during placement. Over a period of ten years, the senior author reports a less than 1% development in capsular contracture using this technique and no implant fractures. These findings elucidate the importance of describing this alternative technique to other barriers currently on the market.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Level of Evidence: 4<\/jats:title>\n                  <jats:p\/>\n               <\/jats:sec>","DOI":"10.1093\/asjof\/ojaa015","type":"journal-article","created":{"date-parts":[[2020,4,15]],"date-time":"2020-04-15T06:46:06Z","timestamp":1586933166000},"source":"Crossref","is-referenced-by-count":6,"title":["A Simple Alternative: A Minimal-Touch Technique for Placing Breast Implants"],"prefix":"10.1093","volume":"2","author":[{"given":"Vanessa","family":"Molinar","sequence":"first","affiliation":[{"name":"Department of Surgery, Division of Plastic Surgery, Mayo Clinic, Rochester, MN"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0412-4356","authenticated-orcid":false,"given":"Karan","family":"Chopra","sequence":"additional","affiliation":[{"name":"Department of Surgery, Division of Plastic Surgery, The Johns Hopkins University School of Medicine, Baltimore, MD"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joe","family":"Gryskiewicz","sequence":"additional","affiliation":[{"name":"Cleft Palate Craniofacial Clinics, University of Minnesota, School of Dentistry, Burnsville, MN"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2020,4,15]]},"reference":[{"issue":"2","key":"2021020111252499100_CIT0001","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1177\/1090820X11434505","article-title":"Contamination in smooth gel breast implant placement: testing a funnel versus digital insertion technique in a cadaver model","volume":"32","author":"Moyer","year":"2012","journal-title":"Aesthet Surg J."},{"issue":"1","key":"2021020111252499100_CIT0002","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.cps.2008.08.007","article-title":"Capsular contracture: what is it? What causes it? How can it be prevented and managed?","volume":"36","author":"Adams","year":"2009","journal-title":"Clin Plast Surg."},{"issue":"3","key":"2021020111252499100_CIT0003","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1097\/PRS.0000000000003575","article-title":"Macrotextured breast implants with defined steps to minimize bacterial contamination around the device: experience in 42,000 implants","volume":"140","author":"Adams","year":"2017","journal-title":"Plast Reconstr Surg."},{"issue":"6","key":"2021020111252499100_CIT0004","doi-asserted-by":"crossref","first-page":"933e","DOI":"10.1097\/PRS.0000000000005050","article-title":"Modern primary breast augmentation: best recommendations for best results","volume":"142","author":"Wan","year":"2018","journal-title":"Plast Reconstr Surg"},{"issue":"5","key":"2021020111252499100_CIT0005","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1093\/asj\/sjv237","article-title":"Does implant insertion with a funnel decrease capsular contracture? A preliminary report","volume":"36","author":"Flugstad","year":"2016","journal-title":"Aesthet Surg J."},{"issue":"6","key":"2021020111252499100_CIT0006","doi-asserted-by":"crossref","first-page":"e1834","DOI":"10.1097\/GOX.0000000000001834","article-title":"Effect of keller funnel on the rate of capsular contracture in periareolar breast augmentation","volume":"6","author":"Newman","year":"2018","journal-title":"Plast Reconstr Surg Glob Open."}],"container-title":["Aesthetic Surgery Journal Open Forum"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/asjopenforum\/advance-article-pdf\/doi\/10.1093\/asjof\/ojaa015\/33046009\/ojaa015.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/asjopenforum\/article-pdf\/2\/2\/ojaa015\/36162507\/asjopenforum_2_2_ojaa015.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/asjopenforum\/article-pdf\/2\/2\/ojaa015\/36162507\/asjopenforum_2_2_ojaa015.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,1]],"date-time":"2021-02-01T13:57:43Z","timestamp":1612187863000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/asjopenforum\/article\/doi\/10.1093\/asjof\/ojaa015\/5820214"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,15]]},"references-count":6,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,6,1]]}},"URL":"https:\/\/doi.org\/10.1093\/asjof\/ojaa015","relation":{},"ISSN":["2631-4797"],"issn-type":[{"value":"2631-4797","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,6]]},"published":{"date-parts":[[2020,4,15]]},"article-number":"ojaa015"}}