{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T17:04:59Z","timestamp":1785431099979,"version":"3.56.0"},"reference-count":25,"publisher":"Oxford University Press (OUP)","license":[{"start":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T00:00:00Z","timestamp":1778025600000},"content-version":"vor","delay-in-days":125,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,14]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Silicone breast implants remain a mainstay of aesthetic surgery; however, long-term rupture remains a significant complication. MRI offers superior sensitivity for detecting silent ruptures. In patients declining reimplantation, autologous breast augmentation using a pedicled transverse rectus abdominis myocutaneous (TRAM) flap combined with fat grafting presents a natural, durable alternative.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>The purpose of this study was to evaluate long-term implant survival and the outcomes of hybrid autologous augmentation using pedicled TRAM flap and fat grafting following explantation for rupture.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A retrospective review was conducted on 150 female patients with 179 ruptured implants (June 2022-September 2024). Implant rupture was confirmed through 3T MRI. Implant longevity was analyzed using Kaplan\u2013Meier survival. A subgroup of 41 patients underwent autologous reconstruction using a modified pedicled TRAM flap plus fat grafting. Intraoperative flap volume was calculated using a geometric model for truncated pyramids. Fat retention was quantified through MRI at 6 to 12 months. Patient-reported satisfaction was assessed using the BREAST-Q Postoperative Augmentation Module.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>MRI demonstrated linguine (25.1%), teardrop (15.6%), and combined rupture signs. Kaplan\u2013Meier analysis showed a 20-year implant survival rate of 83%. In the autologous group (n = 41), the average intraoperative volume was 328.5\u2005cc, with 83.0% fat retention on follow-up MRI. The mean BREAST-Q satisfaction score was 62.7, positively correlating with volume retention (r = 0.317, P = .043).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Hybrid autologous breast augmentation using a TRAM flap and fat grafting is a reliable and aesthetically satisfying alternative to reimplantation. MRI facilitates accurate rupture diagnosis and postoperative volumetric monitoring. This technique also yields abdominal contouring benefits and reduced long-term costs, making it an attractive option for selected patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence: 4 (Therapeutic)<\/jats:title>\n                    <jats:p\/>\n                  <\/jats:sec>","DOI":"10.1093\/asjof\/ojag077","type":"journal-article","created":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T12:25:35Z","timestamp":1777724735000},"source":"Crossref","is-referenced-by-count":0,"title":["Implant Survival and Autologous Breast Augmentation in Rupture Management"],"prefix":"10.1093","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-8781-7810","authenticated-orcid":false,"given":"Tung Dinh","family":"Nguyen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,5,5]]},"reference":[{"key":"2026073012305232200_ojag077-B1","volume-title":"International Survey on Aesthetic\/Cosmetic Procedures Performed in 2023","author":"International Society of Aesthetic Plastic Surgery (ISAPS)","year":"2023"},{"key":"2026073012305232200_ojag077-B2","volume-title":"Silicone Gel\u2013Filled Breast Implants\u2014Rupture Rates","author":"FDA","year":"2022"},{"key":"2026073012305232200_ojag077-B3","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1097\/01.prs.0000233471.58039.30","article-title":"Prevalence of rupture in Inamed silicone breast implants","volume":"118","author":"Heden","year":"2006","journal-title":"Plast Reconstr Surg"},{"key":"2026073012305232200_ojag077-B4","author":"U.S. Food and Drug Administration"},{"key":"2026073012305232200_ojag077-B5","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1007\/s13244-011-0122-3","article-title":"Imaging of breast implants\u2014a pictorial review","volume":"2","author":"Juanpere","year":"2011","journal-title":"Insights Imaging"},{"key":"2026073012305232200_ojag077-B6","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.anplas.2020.09.001","article-title":"Accuracy of mammography, sonography and magnetic resonance imaging for detecting silicone breast implant ruptures: a retrospective observational study of 367 cases","volume":"66","author":"Goldammer","year":"2021","journal-title":"Ann Chir Plast Esthet"},{"key":"2026073012305232200_ojag077-B7","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.cps.2006.10.011","article-title":"Autologous breast reconstruction: TRAM\/DIEP flap outcomes","volume":"34","author":"Nahabedian","year":"2007","journal-title":"Clin Plast Surg"},{"key":"2026073012305232200_ojag077-B8","first-page":"653","volume-title":"Fat Injection: From Filling to Regeneration","author":"Coleman","year":"2018","edition":"2nd ed."},{"key":"2026073012305232200_ojag077-B9","doi-asserted-by":"publisher","first-page":"768","DOI":"10.1097\/01.PRS.0000179739.45032.35","article-title":"Cohesive silicone gel breast implants in aesthetic and reconstructive breast surgery","volume":"116","author":"Brown","year":"2005","journal-title":"Plast Reconstr Surg"},{"key":"2026073012305232200_ojag077-B10","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1097\/PRS.0000000000011841","article-title":". Long-term volume retention of breast augmentation with fat grafting depends on weight changes: a 3-year prospective magnetic resonance imaging study","volume":"155","author":"\u00d8rholt","year":"2025","journal-title":"Plast Reconstr Surg"},{"key":"2026073012305232200_ojag077-B11","doi-asserted-by":"publisher","first-page":"993","DOI":"10.1093\/asj\/sjw048","article-title":"Autologous fat grafting in cosmetic breast augmentation: a systematic review on radiological safety, complications, volume retention, and patient\/surgeon satisfaction","volume":"36","author":"Groen","year":"2016","journal-title":"Aesthetic Plast Surg"},{"key":"2026073012305232200_ojag077-B12","doi-asserted-by":"publisher","DOI":"10.1097\/GOX.0000000000000183","article-title":"Diffusion and perfusion: the keys to fat grafting","volume":"2","author":"Khouri","year":"2014","journal-title":"Plast Reconstr Surg Global Open"},{"key":"2026073012305232200_ojag077-B13","doi-asserted-by":"publisher","first-page":"1524","DOI":"10.1111\/jocd.14234","article-title":"Breast augmentation with autologous fat: 3D imaging evaluation of retention after Coleman technique","volume":"21","author":"Lin","year":"2022","journal-title":"J Cosmet Dermatol"},{"key":"2026073012305232200_ojag077-B14","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1080\/01621459.1958.10501452","article-title":"Nonparametric estimation from incomplete observations","volume":"53","author":"Kaplan","year":"1958","journal-title":"J Am Stat Assoc"},{"key":"2026073012305232200_ojag077-B15","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/j.bjps.2013.11.011","article-title":"Efficacy, safety and complications of autologous fat grafting to healthy breast tissue: a systematic review","volume":"67","author":"Largo","year":"2014","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"2026073012305232200_ojag077-B16","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1002\/micr.30441","article-title":"High long-term retention of cell-assisted lipotransfer in TRAM flap reconstruction","volume":"40","author":"Tissiani","year":"2020","journal-title":"Microsurgery"},{"key":"2026073012305232200_ojag077-B17","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1097\/PRS.0b013e3181aee807","article-title":"Development of a new patient-reported outcome measure for breast surgery: the BREAST-Q","volume":"124","author":"Pusic","year":"2009","journal-title":"Plast Reconstr Surg"},{"key":"2026073012305232200_ojag077-B18","doi-asserted-by":"publisher","first-page":"1476","DOI":"10.1016\/j.bjps.2018.04.029","article-title":"How to assess the volume of a DIEP flap using a free online calculator: the DIEP V method","volume":"71","author":"Razzano","year":"2018","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"2026073012305232200_ojag077-B19","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1007\/s00238-019-01610-1","article-title":"Suspected breast implant rupture: our experience, recommendations on its management and a proposal for a model of informed consent","volume":"43","author":"Zingaretti","year":"2019","journal-title":"Eur J Plast Surg"},{"key":"2026073012305232200_ojag077-B20","doi-asserted-by":"publisher","first-page":"703","DOI":"10.2147\/IJWH.S58493","article-title":"Correlation between MRI results and intraoperative findings in patients with silicone breast implants","volume":"6","author":"Lindenblatt","year":"2014","journal-title":"Int J Womens Health"},{"key":"2026073012305232200_ojag077-B21","doi-asserted-by":"publisher","first-page":"2054","DOI":"10.1097\/00006534-199912000-00016","article-title":"Silicone breast implant rupture: pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound","volume":"104","author":"Ikeda","year":"1999","journal-title":"Plast Reconstr Surg"},{"key":"2026073012305232200_ojag077-B22","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1097\/PRS.0000000000001122","article-title":"Cost-effectiveness of implants versus autologous perforator flaps using the BREAST-Q","volume":"135","author":"Matros","year":"2015","journal-title":"Plast Reconstr Surg"},{"key":"2026073012305232200_ojag077-B23","doi-asserted-by":"publisher","first-page":"2265","DOI":"10.1097\/00006534-200206000-00011","article-title":"Complications in postmastectomy breast reconstruction","volume":"109","author":"Alderman","year":"2002","journal-title":"Plast Reconstr Surg"},{"key":"2026073012305232200_ojag077-B24","doi-asserted-by":"publisher","first-page":"NP277","DOI":"10.1093\/asj\/sjaa001","article-title":"Long-term results of implant-based reconstruction: a 20-year review","volume":"40","author":"Becker","year":"2020","journal-title":"Aesthetic Surg J"},{"key":"2026073012305232200_ojag077-B25","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1097\/SAP.0b013e3181c863b0","article-title":"Patient satisfaction in autologous reconstruction using BREAST-Q","volume":"64","author":"McCarthy","year":"2010","journal-title":"Ann Plast Surg"}],"container-title":["Aesthetic Surgery Journal Open Forum"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/asjopenforum\/advance-article-pdf\/doi\/10.1093\/asjof\/ojag077\/68223733\/ojag077.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/asjopenforum\/article-pdf\/doi\/10.1093\/asjof\/ojag077\/68223733\/ojag077.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/asjopenforum\/article-pdf\/doi\/10.1093\/asjof\/ojag077\/68223733\/ojag077.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T16:30:59Z","timestamp":1785429059000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/asjopenforum\/article\/doi\/10.1093\/asjof\/ojag077\/8670064"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":25,"URL":"https:\/\/doi.org\/10.1093\/asjof\/ojag077","relation":{},"ISSN":["2631-4797"],"issn-type":[{"value":"2631-4797","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026]]},"published":{"date-parts":[[2026]]},"article-number":"ojag077"}}