{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T22:19:46Z","timestamp":1790374786941,"version":"4.1.0"},"reference-count":27,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2008,9,1]],"date-time":"2008-09-01T00:00:00Z","timestamp":1220227200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2008,9,1]],"date-time":"2008-09-01T00:00:00Z","timestamp":1220227200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2017,12,4]],"date-time":"2017-12-04T00:00:00Z","timestamp":1512345600000},"content-version":"vor","delay-in-days":3381,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["bjanaesthesia.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["British Journal of Anaesthesia"],"published-print":{"date-parts":[[2008,9]]},"DOI":"10.1093\/bja\/aen166","type":"journal-article","created":{"date-parts":[[2008,6,17]],"date-time":"2008-06-17T20:13:16Z","timestamp":1213733596000},"page":"411-418","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":51,"title":["Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study"],"prefix":"10.1016","volume":"101","author":[{"given":"D.","family":"Steinmann","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.A.","family":"Stahl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Minner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Schumann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Loop","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Kirschbaum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.J.","family":"Priebe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Guttmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1093\/bja\/aen166_bib1","series-title":"Miller's Anesthesia","first-page":"1847","article-title":"Anesthesia for thoracic surgery","author":"Wilson","year":"2005"},{"key":"10.1093\/bja\/aen166_bib2","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1097\/00000542-200602000-00010","article-title":"Devices for lung isolation used by anesthesiologists with limited thoracic experience: comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker","volume":"104","author":"Campos","year":"2006","journal-title":"Anesthesiology"},{"key":"10.1093\/bja\/aen166_bib3","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1097\/00000542-199802000-00012","article-title":"Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: a prospective study","volume":"88","author":"Klein","year":"1998","journal-title":"Anesthesiology"},{"key":"10.1093\/bja\/aen166_bib4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00001503-200402000-00002","article-title":"Double-lumen tube position should be confirmed by fiberoptic bronchoscopy","volume":"17","author":"Cohen","year":"2004","journal-title":"Curr Opin Anaesthesiol"},{"key":"10.1093\/bja\/aen166_bib5","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1093\/bja\/aeh055","article-title":"Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation","volume":"92","author":"Inoue","year":"2004","journal-title":"Br J Anaesth"},{"key":"10.1093\/bja\/aen166_bib6","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1097\/00000542-198606000-00052","article-title":"End-tidal CO2 analyzers in proper positioning of the double-lumen tubes","volume":"64","author":"Shafieha","year":"1986","journal-title":"Anesthesiology"},{"key":"10.1093\/bja\/aen166_bib7","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1007\/BF03008694","article-title":"Dual end-tidal CO2 monitoring and double-lumen tubes","volume":"39","author":"Shankar","year":"1992","journal-title":"Can J Anaesth"},{"key":"10.1093\/bja\/aen166_bib8","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1097\/00000542-199205000-00033","article-title":"An aid in the diagnosis of malpositioned double-lumen tubes","volume":"76","author":"Simon","year":"1992","journal-title":"Anesthesiology"},{"key":"10.1093\/bja\/aen166_bib9","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1097\/00000542-198801000-00040","article-title":"Intraoperative manipulation for positioning of double-lumen tubes","volume":"68","author":"Cohen","year":"1988","journal-title":"Anesthesiology"},{"key":"10.1093\/bja\/aen166_bib10","doi-asserted-by":"crossref","first-page":"1489","DOI":"10.1213\/01.ane.0000240909.48774.49","article-title":"Acoustic monitoring of double-lumen ventilated lungs for the detection of selective unilateral lung ventilation","volume":"103","author":"Tejman-Yarden","year":"2006","journal-title":"Anesth Analg"},{"key":"10.1093\/bja\/aen166_bib11","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1080\/0309190021000059687","article-title":"Electrical impedance tomography (EIT): a review","volume":"27","author":"Brown","year":"2003","journal-title":"J Med Eng Technol"},{"key":"10.1093\/bja\/aen166_bib12","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s00423-006-0034-8","article-title":"Electrical impedance tomography: changes in distribution of pulmonary ventilation during laparoscopic surgery in a porcine model","volume":"391","author":"Meier","year":"2006","journal-title":"Langenbecks Arch Surg"},{"key":"10.1093\/bja\/aen166_bib13","first-page":"344","article-title":"Electrical impedance tomography guided ventilation therapy","volume":"13","author":"Putensen","year":"2007","journal-title":"Curr Opin Crit Care"},{"key":"10.1093\/bja\/aen166_bib14","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1111\/j.1399-6576.1998.tb05308.x","article-title":"Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography","volume":"42","author":"Frerichs","year":"1998","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1093\/bja\/aen166_bib15","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1164\/rccm.200301-133OC","article-title":"Imbalances in regional lung ventilation: a validation study on electrical impedance tomography","volume":"169","author":"Victorino","year":"2004","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1093\/bja\/aen166_bib16","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1111\/j.1399-6576.2006.01079.x","article-title":"Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery","volume":"50","author":"Erlandsson","year":"2006","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1093\/bja\/aen166_bib17","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1007\/s00134-006-0425-x","article-title":"Regional lung derecruitment after endotracheal suction during volume- or pressure-controlled ventilation: a study using electric impedance tomography","volume":"33","author":"Lindgren","year":"2007","journal-title":"Intensive Care Med"},{"key":"10.1093\/bja\/aen166_bib18","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/S1053-0770(03)00046-6","article-title":"Left double-lumen tubes: clinical experience with 1,170 patients","volume":"17","author":"Brodsky","year":"2003","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1093\/bja\/aen166_bib19","series-title":"Anesthesiology and Critical Care Drug Handbook","author":"Donnelly","year":"2006"},{"key":"10.1093\/bja\/aen166_bib20","first-page":"861","article-title":"Tracheal diameter predicts double-lumen tube size: a method for selecting left double-lumen tubes","volume":"82","author":"Brodsky","year":"1996","journal-title":"Anesth Analg"},{"key":"10.1093\/bja\/aen166_bib21","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.resp.2004.07.014","article-title":"Distribution of ventilation in young and elderly adults determined by electrical impedance tomography","volume":"143","author":"Frerichs","year":"2004","journal-title":"Respir Physiol Neurobiol"},{"key":"10.1093\/bja\/aen166_bib22","series-title":"Intuitive Biostatistics","author":"Motulsky","year":"1995"},{"key":"10.1093\/bja\/aen166_bib23","series-title":"Clinical Anesthesiology","author":"Morgan","year":"2006"},{"key":"10.1093\/bja\/aen166_bib24","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1177\/0310057X9302100520","article-title":"The Australian Incident Monitoring Study. Problems related to the endotracheal tube: an analysis of 2000 incident reports","volume":"21","author":"Szekely","year":"1993","journal-title":"Anaesth Intensive Care"},{"key":"10.1093\/bja\/aen166_bib25","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1213\/01.ANE.0000118104.23660.F3","article-title":"Auscultation of bilateral breath sounds does not rule out endobronchial intubation in children","volume":"99","author":"Verghese","year":"2004","journal-title":"Anesth Analg"},{"key":"10.1093\/bja\/aen166_bib26","doi-asserted-by":"crossref","first-page":"S374","DOI":"10.1097\/01.CCM.0000134354.20449.B2","article-title":"Secondary confirmation of endotracheal tube position by ultrasound image","volume":"32","author":"Hsieh","year":"2004","journal-title":"Crit Care Med"},{"key":"10.1093\/bja\/aen166_bib27","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/1053-0770(93)90303-3","article-title":"The position of a double-lumen tube should be routinely determined by fiberoptic bronchoscopy","volume":"7","author":"Benumof","year":"1993","journal-title":"J Cardiothorac Vasc Anesth"}],"container-title":["British Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0007091217342083?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0007091217342083?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/academic.oup.com\/bja\/article-pdf\/101\/3\/411\/18252202\/aen166.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T18:46:04Z","timestamp":1757789164000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0007091217342083"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,9]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2008,9]]}},"alternative-id":["S0007091217342083"],"URL":"https:\/\/doi.org\/10.1093\/bja\/aen166","relation":{},"ISSN":["0007-0912"],"issn-type":[{"value":"0007-0912","type":"print"}],"subject":[],"published":{"date-parts":[[2008,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study","name":"articletitle","label":"Article Title"},{"value":"British Journal of Anaesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1093\/bja\/aen166","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2008 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}