{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T02:50:39Z","timestamp":1761706239366,"version":"3.44.0"},"reference-count":18,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2008,9,1]],"date-time":"2008-09-01T00:00:00Z","timestamp":1220227200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2008,9,1]],"date-time":"2008-09-01T00:00:00Z","timestamp":1220227200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2017,12,4]],"date-time":"2017-12-04T00:00:00Z","timestamp":1512345600000},"content-version":"vor","delay-in-days":3381,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["bjanaesthesia.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["British Journal of Anaesthesia"],"published-print":{"date-parts":[[2008,9]]},"DOI":"10.1093\/bja\/aen167","type":"journal-article","created":{"date-parts":[[2008,6,13]],"date-time":"2008-06-13T22:37:28Z","timestamp":1213396648000},"page":"424-428","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["The Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers"],"prefix":"10.1016","volume":"101","author":[{"given":"S.","family":"Ghosh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.A.","family":"Klein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Prabhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Falter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.E.","family":"Arrowsmith","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1093\/bja\/aen167_bib1","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/ACO.0b013e3280111e2a","article-title":"Which device should be considered the best for lung isolation: double lumen endotracheal tubes versus bronchus blockers","volume":"20","author":"Campos","year":"2007","journal-title":"Curr Opin Anaesthesiol"},{"key":"10.1093\/bja\/aen167_bib2","first-page":"283","article-title":"A comparison of a left-sided Broncho-Cath, with the torque control blocker Univent\u00ae and the wire-guided blocker","volume":"96","author":"Campos","year":"2003","journal-title":"Anesth Analg"},{"key":"10.1093\/bja\/aen167_bib3","first-page":"250","article-title":"Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy","volume":"45","author":"Bauer","year":"2001","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1093\/bja\/aen167_bib4","doi-asserted-by":"crossref","first-page":"1728","DOI":"10.1213\/01.ANE.0000149895.99151.20","article-title":"Endobronchial blocker dislodgement leading to pulseless electrical activity","volume":"100","author":"Sandberg","year":"2005","journal-title":"Anesth Analg"},{"key":"10.1093\/bja\/aen167_bib5","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.thorsurg.2004.09.003","article-title":"Progress in lung separation","volume":"15","author":"Campos","year":"2005","journal-title":"Thorac Surg Clin"},{"key":"10.1093\/bja\/aen167_bib6","doi-asserted-by":"crossref","first-page":"1877","DOI":"10.1213\/01.ANE.0000184116.86888.D9","article-title":"The Cohen flexitip endobronchial blocker: an alternative to double lumen tubes","volume":"101","author":"Cohen","year":"2005","journal-title":"Anesth Analg"},{"key":"10.1093\/bja\/aen167_bib7","first-page":"1317","article-title":"Experience using an improved bronchial blocker (Phycon TCB bronchial blocker)","volume":"53","author":"Sarabi","year":"2004","journal-title":"Jpn J Anesth"},{"key":"10.1093\/bja\/aen167_bib8","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1034\/j.1399-6576.1999.430320.x","article-title":"One-lung ventilation when intubation is difficult: presentation of a new endobronchial blocker","volume":"43","author":"Arndt","year":"1999","journal-title":"Acta Anaesthesiol Scand"},{"key":"10.1093\/bja\/aen167_bib9","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1016\/S0022-5223(19)37196-X","article-title":"New device for one-lung anesthesia: endotracheal tube with movable blocker","volume":"83","author":"Inoue","year":"1982","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1093\/bja\/aen167_bib10","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1097\/00000542-200602000-00010","article-title":"Devices for lung isolation used by anesthesiologists with limited thoracic experience","volume":"104","author":"Campos","year":"2006","journal-title":"Anesthesiology"},{"key":"10.1093\/bja\/aen167_bib11","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1016\/S1053-0770(97)90153-1","article-title":"Thoracic surgery and difficult intubation: another application of the Univent\u00ae tube for one-lung ventilation","volume":"7","author":"Garcia-Aguado","year":"1997","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1093\/bja\/aen167_bib12","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/BF03012521","article-title":"Wire-guided endobronchial blockade in a patient with limited mouth opening","volume":"46","author":"Arndt","year":"1999","journal-title":"Can J Anaesth"},{"key":"10.1093\/bja\/aen167_bib13","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1097\/01.ta.0000202548.71066.a5","article-title":"The wire guided endobronchial blocker: applications in trauma patients beyond mere single-lung ventilation","volume":"61","author":"Byhahn","year":"2006","journal-title":"J Trauma"},{"key":"10.1093\/bja\/aen167_bib14","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1097\/00005373-200011000-00023","article-title":"A new technique for lung isolation in acute thoracic trauma","volume":"49","author":"Grocott","year":"2000","journal-title":"J Trauma"},{"key":"10.1093\/bja\/aen167_bib15","first-page":"643","article-title":"Anaesthesia in thoracic surgery with special reference to lobectomy","volume":"29","author":"Magill","year":"1936","journal-title":"Proc R Soc Med"},{"key":"10.1093\/bja\/aen167_bib16","first-page":"742","article-title":"A new flexible double-lumen catheter for bronchospirometry","volume":"18","author":"Carlens","year":"1949","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1093\/bja\/aen167_bib17","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1093\/bja\/34.8.576","article-title":"Low resistance double-lumen endobronchial tubes","volume":"34","author":"Robertshaw","year":"1962","journal-title":"Br J Anaesth"},{"key":"10.1093\/bja\/aen167_bib18","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1016\/S0022-5223(19)39292-X","article-title":"New technique for one lung anaesthesia using an endobronchial blocker","volume":"82","author":"Ginsberg","year":"1981","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["British Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0007091217342101?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0007091217342101?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/academic.oup.com\/bja\/article-pdf\/101\/3\/424\/672102\/aen167.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T18:46:11Z","timestamp":1757789171000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0007091217342101"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,9]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2008,9]]}},"alternative-id":["S0007091217342101"],"URL":"https:\/\/doi.org\/10.1093\/bja\/aen167","relation":{},"ISSN":["0007-0912"],"issn-type":[{"type":"print","value":"0007-0912"}],"subject":[],"published":{"date-parts":[[2008,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers","name":"articletitle","label":"Article Title"},{"value":"British Journal of Anaesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1093\/bja\/aen167","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2008 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}