{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T10:12:19Z","timestamp":1780481539172,"version":"3.54.1"},"reference-count":32,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2011,8,1]],"date-time":"2011-08-01T00:00:00Z","timestamp":1312156800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,8,1]],"date-time":"2011-08-01T00:00:00Z","timestamp":1312156800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2017,12,4]],"date-time":"2017-12-04T00:00:00Z","timestamp":1512345600000},"content-version":"vor","delay-in-days":2317,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["bjanaesthesia.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["British Journal of Anaesthesia"],"published-print":{"date-parts":[[2011,8]]},"DOI":"10.1093\/bja\/aer123","type":"journal-article","created":{"date-parts":[[2011,6,10]],"date-time":"2011-06-10T20:49:53Z","timestamp":1307738993000},"page":"202-208","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":45,"title":["Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients"],"prefix":"10.1016","volume":"107","author":[{"given":"F.","family":"Franchi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Silvestri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Cubattoli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.S.","family":"Taccone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Donadello","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.M.","family":"Romano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Giomarelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W.T.","family":"McBride","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Scolletta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1093\/bja\/aer123_bib1","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1056\/NEJMoa010307","article-title":"Early goal directed therapy in the treatment of severe sepsis and septic shock","volume":"345","author":"Rivers","year":"2001","journal-title":"N Engl J Med"},{"key":"10.1093\/bja\/aer123_bib2","doi-asserted-by":"crossref","first-page":"2020","DOI":"10.1378\/chest.07-0073","article-title":"Hemodynamic evaluation and monitoring in the ICU","volume":"132","author":"Pinsky","year":"2007","journal-title":"Chest"},{"key":"10.1093\/bja\/aer123_bib3","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1378\/chest.122.3.990","article-title":"Lack of agreement between thermodilution and Fick cardiac output in critically ill patients","volume":"122","author":"Dhingra","year":"2002","journal-title":"Chest"},{"key":"10.1093\/bja\/aer123_bib4","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1016\/S0140-6736(05)67061-4","article-title":"Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomized controlled trial","volume":"366","author":"Harvey","year":"2005","journal-title":"Lancet"},{"key":"10.1093\/bja\/aer123_bib5","doi-asserted-by":"crossref","first-page":"3093","DOI":"10.1097\/CCM.0b013e31818c10c7","article-title":"The pulmonary artery catheter: in medio virtus","volume":"36","author":"Vincent","year":"2008","journal-title":"Crit Care Med"},{"key":"10.1093\/bja\/aer123_bib6","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1097\/ACO.0b013e328332a473","article-title":"Cardiac output derived from arterial pressure waveform","volume":"22","author":"Mayer","year":"2009","journal-title":"Curr Opin Anaesthesiol"},{"key":"10.1093\/bja\/aer123_bib7","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1093\/bja\/82.4.525","article-title":"Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients","volume":"82","author":"R\u00f6dig","year":"1999","journal-title":"Br J Anaesth"},{"key":"10.1093\/bja\/aer123_bib8","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1213\/ANE.0b013e3181c135f1","article-title":"Estimation of hemodynamic parameters by arterial waveform: available technologies","volume":"110","author":"Romagnoli","year":"2010","journal-title":"Anesth Analg"},{"key":"10.1093\/bja\/aer123_bib9","doi-asserted-by":"crossref","first-page":"R109","DOI":"10.1186\/cc9058","article-title":"Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices","volume":"14","author":"Monnet","year":"2010","journal-title":"Crit Care"},{"key":"10.1093\/bja\/aer123_bib10","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1097\/01.CCM.OB013E318161FEC4","article-title":"Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period","volume":"36","author":"Hamzaoui","year":"2008","journal-title":"Crit Care Med"},{"key":"10.1093\/bja\/aer123_bib11","doi-asserted-by":"crossref","first-page":"1834","DOI":"10.1097\/00003246-200208000-00027","article-title":"Assessment of cardiac output from systemic arterial pressure in humans","volume":"30","author":"Romano","year":"2002","journal-title":"Crit Care Med"},{"key":"10.1093\/bja\/aer123_bib12","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.ejcts.2004.05.025","article-title":"Cardiac output monitoring by pressure recording analytical method in cardiac surgery","volume":"26","author":"Giomarelli","year":"2004","journal-title":"Eur J Cardiothorac Surg"},{"key":"10.1093\/bja\/aer123_bib13","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1093\/bja\/aei154","article-title":"Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states","volume":"95","author":"Scolletta","year":"2005","journal-title":"Br J Anaesth"},{"key":"10.1093\/bja\/aer123_bib14","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/PCC.0b013e31816c7151","article-title":"Assessment of cardiac output in children: a comparison between the pressure recording analytical method and Doppler echocardiography","volume":"9","author":"Calamandrei","year":"2008","journal-title":"Pediatr Crit Care Med"},{"key":"10.1093\/bja\/aer123_bib15","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1097\/00000542-199212000-00024","article-title":"The fast flush test measures the dynamic response of the entire blood pressure monitoring system","volume":"77","author":"Kleinman","year":"1992","journal-title":"Anesthesiology"},{"key":"10.1093\/bja\/aer123_bib16","series-title":"R: A Language and Environment for Statistical Computing","author":"R Development Core Team.","year":"2010"},{"key":"10.1093\/bja\/aer123_bib17","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"10.1093\/bja\/aer123_bib18","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1023\/A:1009982611386","article-title":"A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques","volume":"15","author":"Critchley","year":"1999","journal-title":"J Clin Monitor"},{"key":"10.1093\/bja\/aer123_bib19","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1093\/bja\/aem214","article-title":"Using the Bland\u2013Altman method to measure agreement with repeated measures","volume":"99","author":"Myles","year":"2007","journal-title":"Br J Anaesth"},{"key":"10.1093\/bja\/aer123_bib20","author":"Carstensen"},{"key":"10.1093\/bja\/aer123_bib21","author":"Carstensen"},{"key":"10.1093\/bja\/aer123_bib22","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1093\/bja\/aen343","article-title":"Evaluation of an uncalibrated arterial pulse contour cardiac output monitor system in cirrhotic patients undergoing liver surgery","volume":"102","author":"Biancofiore","year":"2009","journal-title":"Br J Anaesth"},{"key":"10.1093\/bja\/aer123_bib23","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1093\/bja\/87.2.212","article-title":"A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients","volume":"87","author":"Jansen","year":"2001","journal-title":"Br J Anaesth"},{"key":"10.1093\/bja\/aer123_bib24","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1097\/00000542-199808000-00010","article-title":"Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: a comparison to thermodilution","volume":"89","author":"Perrino","year":"1998","journal-title":"Anesthesiology"},{"key":"10.1093\/bja\/aer123_bib25","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1093\/bja\/aem177","article-title":"Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis","volume":"99","author":"Sakka","year":"2007","journal-title":"Br J Anaesth"},{"key":"10.1093\/bja\/aer123_bib26","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1053\/j.jvca.2006.08.004","article-title":"Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration","volume":"21","author":"Manecke","year":"2007","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"10.1093\/bja\/aer123_bib27","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1016\/0021-9290(85)90015-6","article-title":"The pressure-dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five-component model","volume":"18","author":"Langewouters","year":"1985","journal-title":"J Biomech"},{"key":"10.1093\/bja\/aer123_bib28","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.1213\/ane.0b013e318168b309","article-title":"Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis","volume":"106","author":"Biais","year":"2008","journal-title":"Anesth Analg"},{"key":"10.1093\/bja\/aer123_bib29","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1097\/00000542-198103000-00010","article-title":"Direct blood pressure measurement: dynamic response requirements","volume":"54","author":"Gardner","year":"1981","journal-title":"Anesthesiology"},{"key":"10.1093\/bja\/aer123_bib30","first-page":"43","article-title":"Dynamics of invasive pressure monitoring systems: clinical and laboratory evaluation","volume":"17","author":"Gibbs","year":"1988","journal-title":"Heart Lung"},{"key":"10.1093\/bja\/aer123_bib31","first-page":"S147","article-title":"Pulse wave analysis","volume":"14","author":"O'Rourke","year":"1996","journal-title":"J Hypertens"},{"key":"10.1093\/bja\/aer123_bib32","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.biopha.2010.01.001","article-title":"Relationship between N-terminal pro-B-type natriuretic peptide (Nt-proBNP) and cardiac cycle efficiency in cardiac surgery","volume":"64","author":"Scolletta","year":"2010","journal-title":"Biomed Pharmacother"}],"container-title":["British Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0007091217331161?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0007091217331161?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/academic.oup.com\/bja\/article-pdf\/107\/2\/202\/844178\/aer123.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T18:42:27Z","timestamp":1757788947000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0007091217331161"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,8]]},"references-count":32,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,8]]}},"alternative-id":["S0007091217331161"],"URL":"https:\/\/doi.org\/10.1093\/bja\/aer123","relation":{},"ISSN":["0007-0912"],"issn-type":[{"value":"0007-0912","type":"print"}],"subject":[],"published":{"date-parts":[[2011,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients","name":"articletitle","label":"Article Title"},{"value":"British Journal of Anaesthesia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1093\/bja\/aer123","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2011 The Author(s). Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}