{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T07:29:10Z","timestamp":1782804550518,"version":"3.54.5"},"reference-count":16,"publisher":"Oxford University Press (OUP)","issue":"1175","license":[{"start":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:00:00Z","timestamp":1749168000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Photon-counting detector CT (PCD-CT) represents a significant advancement in medical imaging, particularly for musculoskeletal (MSK) applications. Its primary innovation lies in enhanced spatial resolution, which facilitates improved detection of small anatomical structures such as trabecular bone, osteophytes, and subchondral cysts. PCD-CT enables high-quality imaging with reduced radiation doses, making it especially beneficial for populations requiring frequent imaging, such as paediatric patients and individuals with multiple myeloma. Additionally, PCD-CT supports advanced applications like bone quality assessment, which correlates well with gold-standard tests, and can aid in diagnosing osteoporosis and assessing fracture risk. Techniques such as spectral shaping and virtual monoenergetic imaging further optimize the technology, minimizing artefacts and enhancing material decomposition. These capabilities extend to conditions like gout and haematologic malignancies, offering improved detection and assessment. The integration of artificial intelligence could enhance PCD-CT\u2019s performance by reducing image noise and improving quantitative assessments. Ultimately, PCD-CT\u2019s superior resolution, reduced dose protocols, and multi-energy imaging capabilities will likely have a transformative impact on MSK imaging, improving diagnostic accuracy, patient care, and clinical outcomes.<\/jats:p>","DOI":"10.1093\/bjr\/tqaf124","type":"journal-article","created":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T12:21:09Z","timestamp":1749212469000},"page":"1859-1862","source":"Crossref","is-referenced-by-count":9,"title":["Photon-counting detector CT in musculoskeletal imaging: benefits and outlook"],"prefix":"10.1093","volume":"98","author":[{"given":"Ahmed O","family":"El Sadaney","sequence":"first","affiliation":[{"name":"Department of Radiology, Mayo Clinic , Rochester, MN 55905,","place":["United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Ferrero","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic , Rochester, MN 55905,","place":["United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8314-3642","authenticated-orcid":false,"given":"Kishore","family":"Rajendran","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic , Rochester, MN 55905,","place":["United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald","family":"Booij","sequence":"additional","affiliation":[{"name":"Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center , Rotterdam, Postbus 2040, 3000 CA, The","place":["Netherlands"]},{"name":"Center for Medical Image Science and Visualization (CMIV), Link\u00f6ping University , 581 85 Link\u00f6ping,","place":["Sweden"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roy","family":"Marcus","sequence":"additional","affiliation":[{"name":"Department of Radiology, Balgrist University Hospital, University of Zurich , 8008 Z\u00fcrich,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reto","family":"Sutter","sequence":"additional","affiliation":[{"name":"Department of Radiology, Balgrist University Hospital, University of Zurich , 8008 Z\u00fcrich,","place":["Switzerland"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edwin H G","family":"Oei","sequence":"additional","affiliation":[{"name":"Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center , Rotterdam, Postbus 2040, 3000 CA, The","place":["Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8005-4823","authenticated-orcid":false,"given":"Francis","family":"Baffour","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic , Rochester, MN 55905,","place":["United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2025,6,6]]},"reference":[{"key":"2025112712215341600_tqaf124-B1","doi-asserted-by":"crossref","first-page":"551","DOI":"10.2214\/AJR.22.28418","article-title":"Photon-counting detector CT for musculoskeletal imaging: a clinical perspective","volume":"220","author":"Baffour","year":"2023","journal-title":"AJR Am J Roentgenol"},{"key":"2025112712215341600_tqaf124-B2","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1097\/RLI.0000000000000616","article-title":"Effects of detector sampling on noise reduction in clinical photon-counting whole-body computed tomography","volume":"55","author":"Klein","year":"2020","journal-title":"Invest Radiol"},{"key":"2025112712215341600_tqaf124-B3","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1007\/s00256-022-04117-2","article-title":"Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT","volume":"52","author":"Rajendran","year":"2023","journal-title":"Skeletal Radiol"},{"key":"2025112712215341600_tqaf124-B4","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1007\/s00256-024-04770-9","article-title":"Quantitative metrics of bone quality determined at the distal radius using photon-counting CT","volume":"54","author":"Dutta","year":"2025","journal-title":"Skeletal Radiol"},{"key":"2025112712215341600_tqaf124-B5","doi-asserted-by":"crossref","first-page":"1651","DOI":"10.1007\/s00256-023-04325-4","article-title":"Feasibility of photon-counting CT for femoroacetabular impingement syndrome evaluation: lower radiation dose and improved diagnostic confidence","volume":"52","author":"Ferrero","year":"2023","journal-title":"Skeletal Radiol"},{"key":"2025112712215341600_tqaf124-B6","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1148\/radiol.220311","article-title":"Photon-counting detector CT with deep learning noise reduction to detect multiple myeloma","volume":"306","author":"Baffour","year":"2023","journal-title":"Radiology"},{"key":"2025112712215341600_tqaf124-B7","doi-asserted-by":"crossref","first-page":"e2329950","DOI":"10.2214\/AJR.23.29950","article-title":"Photon-counting detector CT versus energy-integrating detector CT of the lumbar spine: comparison of radiation dose and image quality","volume":"222","author":"Marth","year":"2024","journal-title":"AJR Am J Roentgenol"},{"key":"2025112712215341600_tqaf124-B8","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1097\/RLI.0000000000001058","article-title":"Photon-counting detector CT: clinical utility of virtual monoenergetic imaging combined with tin prefiltration to reduce metal artifacts in the postoperative ankle","volume":"59","author":"Marth","year":"2024","journal-title":"Invest Radiol"},{"key":"2025112712215341600_tqaf124-B9","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s00256-020-03528-3","article-title":"Benefits of iterative metal artifact reduction and dual-energy CT towards mitigating artifact in the setting of total shoulder prostheses","volume":"50","author":"Mohammadinejad","year":"2021","journal-title":"Skeletal Radiol"},{"key":"2025112712215341600_tqaf124-B10","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.2214\/AJR.21.27139","article-title":"Evolving role of dual-energy CT in the clinical workup of gout: a retrospective study","volume":"218","author":"Baffour","year":"2022","journal-title":"AJR Am J Roentgenol"},{"key":"2025112712215341600_tqaf124-B11","doi-asserted-by":"crossref","first-page":"4848","DOI":"10.1118\/1.4926780","article-title":"A general framework of noise suppression in material decomposition for dual-energy CT","volume":"42","author":"Petrongolo","year":"2015","journal-title":"Med Phys"},{"key":"2025112712215341600_tqaf124-B12","doi-asserted-by":"crossref","first-page":"2052","DOI":"10.1002\/mp.17664","article-title":"Spatial resolution improvements for photon counting detectors using coincidence counting and frequency weighted reconstruction","volume":"52","author":"Hsieh","year":"2025","journal-title":"Med Phys"},{"key":"2025112712215341600_tqaf124-B13","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1002\/mp.14047","article-title":"Multi-energy inter-pixel coincidence counters for charge sharing correction and compensation in photon counting detectors","volume":"47","author":"Taguchi","year":"2020","journal-title":"Med Phys"},{"key":"2025112712215341600_tqaf124-B14","doi-asserted-by":"crossref","first-page":"e2329765","DOI":"10.2214\/AJR.23.29765","article-title":"Photon-counting detector CT with denoising for imaging of the osseous pelvis at low radiation doses: a phantom study","volume":"222","author":"Marcus","year":"2024","journal-title":"AJR Am J Roentgenol"},{"key":"2025112712215341600_tqaf124-B15","doi-asserted-by":"crossref","first-page":"e2431909","DOI":"10.2214\/AJR.24.31909","article-title":"Opportunistic bone mineral density measurement using photon-counting detector CT spectral localizer images: a prospective study","volume":"224","author":"El Sadaney","year":"2025","journal-title":"AJR Am J Roentgenol"},{"key":"2025112712215341600_tqaf124-B16","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000001201","article-title":"Dual-source dual-energy imaging using photon-counting detector CT FOR bone edema detection: Leveraging tin prefiltration for improved spectral performance","author":"Rajendran","year":"2025","journal-title":"Invest Radiol"}],"container-title":["British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/advance-article-pdf\/doi\/10.1093\/bjr\/tqaf124\/63446307\/tqaf124.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/98\/1175\/1859\/63446307\/tqaf124.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/98\/1175\/1859\/63446307\/tqaf124.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T17:22:01Z","timestamp":1764264121000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/98\/1175\/1859\/8157878"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,6]]},"references-count":16,"journal-issue":{"issue":"1175","published-online":{"date-parts":[[2025,6,6]]},"published-print":{"date-parts":[[2025,11,1]]}},"URL":"https:\/\/doi.org\/10.1093\/bjr\/tqaf124","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"value":"0007-1285","type":"print"},{"value":"1748-880X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,11]]},"published":{"date-parts":[[2025,6,6]]}}}