{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T08:34:34Z","timestamp":1772181274251,"version":"3.50.1"},"reference-count":24,"publisher":"Oxford University Press (OUP)","issue":"1178","license":[{"start":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T00:00:00Z","timestamp":1763424000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"DOI":"10.13039\/501100012166","name":"National Key R&D Program of China","doi-asserted-by":"publisher","award":["2022YFC2010000"],"award-info":[{"award-number":["2022YFC2010000"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012166","name":"National Key R&D Program of China","doi-asserted-by":"publisher","award":["2022YFC2010006"],"award-info":[{"award-number":["2022YFC2010006"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To compare the free-breathing motion-corrected (MOCO) sequence with the segmented breath-hold (BH) sequence in subjects undergoing late gadolinium enhancement (LGE) scans of cardiac MRI.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>Retrospectively enrolled 71 consecutive subjects underwent MOCO-LGE and BH-LGE sequences in random order. Semi-quantitative image quality (IQ) scores, image contrast-to-noise ratios (CNRs), myocardial scar size, and thickness of pericardial effusion were evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Compared to BH-LGE images, MOCO-LGE images showed improved CNR of the scar to the remote myocardium (11.46 [6.43-16.82] vs. 7.94 [4.36-12.65], P\u2009&amp;lt;\u2009.001) as well as higher IQ scores (4.25\u2009\u00b1\u20090.60 vs. 3.70\u2009\u00b1\u20090.88, P\u2009&amp;lt;\u2009.001). More subepicardial scar was seen in MOCO-LGE than BH-LGE images (83.6% vs. 43.3%, P\u2009&amp;lt;\u2009.001) in lateral wall, and larger scar size was measured by MOCO-LGE than BH-LGE images by using 3-standard deviation (SD) method (24.39 [16.90-33.02] vs. 15.62 [10.67-24.76], P\u2009&amp;lt;\u2009.001) and 5-SD method (8.44 [4.89-13.53] vs. 4.30 [1.63-8.21], P\u2009&amp;lt;\u2009.001). More and thicker epicardial effusions were seen in MOCO-LGE than BH-LGE images (81.7% vs. 60.6%, P\u2009=\u2009.001, and 9.16\u2009\u00b1\u20094.44\u2009mm vs. 6.24\u2009\u00b1\u20094.16\u2009mm, P\u2009&amp;lt;\u2009.001).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>MOCO-LGE images demonstrate superior quality compared to BH-LGE images. However, MOCO-LGE images have a tendency to overestimate the extent of subepicardial scar and pericardial effusion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Advances in knowledge<\/jats:title>\n                    <jats:p>Our study demonstrates that MOCO-LGE images tend to overestimate the extent of subepicardial scar and pericardial effusion in comparison to BH-LGE images, suggesting potential diagnostic misconceptions and an area for improvement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/bjr\/tqaf277","type":"journal-article","created":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T18:33:52Z","timestamp":1763490832000},"page":"367-376","source":"Crossref","is-referenced-by-count":0,"title":["Diagnostic pearls and potential pitfalls of free-breathing motion-corrected late gadolinium enhancement: a head-to-head comparative study"],"prefix":"10.1093","volume":"99","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-6829-6932","authenticated-orcid":false,"given":"Yangzhen","family":"Hou","sequence":"first","affiliation":[{"name":"Department of Radiology, Xiangya Hospital, Central South University , Changsha, Hunan 410008,","place":["China"]},{"name":"Hunan Engineering Research Center of Smart Medical Imaging , Changsha, Hunan 410008,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shulin","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xiangya Hospital, Central South University , Changsha, Hunan 410008,","place":["China"]},{"name":"Hunan Engineering Research Center of Smart Medical Imaging , Changsha, Hunan 410008,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yajuan","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xiangya Hospital, Central South University , Changsha, Hunan 410008,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jing","family":"Luo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xiangya Hospital, Central South University , Changsha, Hunan 410008,","place":["China"]},{"name":"Hunan Engineering Research Center of Smart Medical Imaging , Changsha, Hunan 410008,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ji","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xiangya Hospital, Central South University , Changsha, Hunan 410008,","place":["China"]},{"name":"Hunan Engineering Research Center of Smart Medical Imaging , Changsha, Hunan 410008,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yijie","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xiangya Hospital, Central South University , Changsha, Hunan 410008,","place":["China"]},{"name":"Hunan Engineering Research Center of Smart Medical Imaging , Changsha, Hunan 410008,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9603-7451","authenticated-orcid":false,"given":"Hui","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xiangya Hospital, Central South University , Changsha, Hunan 410008,","place":["China"]},{"name":"Hunan Engineering Research Center of Smart Medical Imaging , Changsha, Hunan 410008,","place":["China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2025,11,18]]},"reference":[{"key":"2026022702514629800_tqaf277-B1","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/1532-429X-12-30","article-title":"Extent of late gadolinium enhancement detected by cardiovascular magnetic resonance correlates with the inducibility of ventricular tachyarrhythmia in hypertrophic cardiomyopathy","volume":"12","author":"Fluechter","year":"2010","journal-title":"J Cardiovasc Magn Reson"},{"key":"2026022702514629800_tqaf277-B2","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1080\/10976640701547335","article-title":"Functional outcome after revascularization in patients with chronic ischemic heart disease: a quantitative late gadolinium enhancement CMR study evaluating transmural scar extent, wall thickness and periprocedural necrosis","volume":"9","author":"Bondarenko","year":"2007","journal-title":"J Cardiovasc Magn Reson"},{"key":"2026022702514629800_tqaf277-B3","doi-asserted-by":"crossref","first-page":"900","DOI":"10.2174\/1573405614666180912100253","article-title":"LGE-MRI in the assessment of left-ventricular remodelling in myocarditis","volume":"15","author":"Yuan","year":"2019","journal-title":"Curr Med Imaging Rev"},{"key":"2026022702514629800_tqaf277-B4","doi-asserted-by":"crossref","first-page":"4615","DOI":"10.1007\/s00330-018-5391-5","article-title":"LGE-CMR-derived texture features reflect poor prognosis in hypertrophic cardiomyopathy patients with systolic dysfunction: preliminary results","volume":"28","author":"Cheng","year":"2018","journal-title":"Eur Radiol"},{"key":"2026022702514629800_tqaf277-B5","doi-asserted-by":"crossref","first-page":"2151","DOI":"10.1016\/j.ejrad.2014.09.002","article-title":"Ultra low-dose of gadobenate dimeglumine for late gadolinium enhancement (LGE) imaging in acute myocardial infarction: a feasibility study","volume":"83","author":"Galea","year":"2014","journal-title":"Eur J Radiol"},{"key":"2026022702514629800_tqaf277-B6","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1136\/heartjnl-2013-305187","article-title":"Extensive late gadolinium enhancement on cardiovascular magnetic resonance predicts adverse outcomes and lack of improvement in LV function after steroid therapy in cardiac sarcoidosis","volume":"100","author":"Ise","year":"2014","journal-title":"Heart"},{"key":"2026022702514629800_tqaf277-B7","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/s12968-016-0225-6","article-title":"Role of cardiovascular magnetic resonance in the guidelines of the European society of cardiology","volume":"18","author":"von Knobelsdorff-Brenkenhoff","year":"2016","journal-title":"J Cardiovasc Magn Reson"},{"key":"2026022702514629800_tqaf277-B8","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/1532-429X-10-35","article-title":"Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols","volume":"10","author":"Kramer","year":"2008","journal-title":"J Cardiovasc Magn Reson"},{"key":"2026022702514629800_tqaf277-B9","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1002\/mrm.10051","article-title":"Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement","volume":"47","author":"Kellman","year":"2002","journal-title":"Magn Reson Med"},{"key":"2026022702514629800_tqaf277-B10","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1148\/radiology.218.1.r01ja50215","article-title":"An improved MR imaging technique for the visualization of myocardial infarction","volume":"218","author":"Simonetti","year":"2001","journal-title":"Radiology"},{"key":"2026022702514629800_tqaf277-B11","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1148\/radiol.2471070132","article-title":"Respiratory motion and cardiac arrhythmia effects on diagnostic accuracy of myocardial delayed-enhanced MR imaging in canines","volume":"247","author":"Sievers","year":"2008","journal-title":"Radiology"},{"key":"2026022702514629800_tqaf277-B12","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1081\/JCMR-120022267","article-title":"How we perform delayed enhancement imaging","volume":"5","author":"Kim","year":"2003","journal-title":"J Cardiovasc Magn Reson"},{"key":"2026022702514629800_tqaf277-B13","doi-asserted-by":"crossref","first-page":"300060520964664","DOI":"10.1177\/0300060520964664","article-title":"Motion-corrected free-breathing late gadolinium enhancement combined with a gadolinium contrast agent with a high relaxation rate: an optimized cardiovascular magnetic resonance examination protocol","volume":"48","author":"Yan","year":"2020","journal-title":"J Int Med Res"},{"key":"2026022702514629800_tqaf277-B14","doi-asserted-by":"crossref","first-page":"1893","DOI":"10.1007\/s10554-019-01620-x","article-title":"Motion-corrected free-breathing LGE delivers high quality imaging and reduces scan time by half: an independent validation study","volume":"35","author":"Captur","year":"2019","journal-title":"Int J Cardiovasc Imaging"},{"key":"2026022702514629800_tqaf277-B15","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.3348\/kjr.2020.1296","article-title":"Free-breathing motion-corrected single-shot phase-sensitive inversion recovery late-gadolinium-enhancement imaging: a prospective study of image quality in patients with hypertrophic cardiomyopathy","volume":"22","author":"Cha","year":"2021","journal-title":"Korean J Radiol"},{"key":"2026022702514629800_tqaf277-B16","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1161\/CIRCIMAGING.112.000022","article-title":"Free-breathing, motion-corrected late gadolinium enhancement is robust and extends risk stratification to vulnerable patients","volume":"6","author":"Piehler","year":"2013","journal-title":"Circ Cardiovasc Imaging"},{"key":"2026022702514629800_tqaf277-B17","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1007\/s00247-016-3553-7","article-title":"Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children","volume":"46","author":"Olivieri","year":"2016","journal-title":"Pediatr Radiol"},{"key":"2026022702514629800_tqaf277-B18","doi-asserted-by":"crossref","first-page":"471.e17","DOI":"10.1016\/j.crad.2021.01.018","article-title":"Myocardial motion-corrected phase-sensitive inversion recovery late gadolinium enhancement in free breathing paediatric patients: a comparison with single-shot coherent gradient echo (\"TrueFISP\") phase-sensitive inversion recovery","volume":"76","author":"Xie","year":"2021","journal-title":"Clin Radiol"},{"key":"2026022702514629800_tqaf277-B19","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1002\/jmri.20969","article-title":"Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters","volume":"26","author":"Dietrich","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"2026022702514629800_tqaf277-B20","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1186\/s12968-014-0085-x","article-title":"Accuracy and reproducibility of semi-automated late gadolinium enhancement quantification techniques in patients with hypertrophic cardiomyopathy","volume":"16","author":"Mikami","year":"2014","journal-title":"J Cardiovasc Magn Reson"},{"key":"2026022702514629800_tqaf277-B21","doi-asserted-by":"crossref","first-page":"5047","DOI":"10.3390\/jcm13175047","article-title":"Myocardial fibrosis quantification methods by cardiovascular magnetic resonance imaging in patients with Fabry disease","volume":"13","author":"Sokolska","year":"2024","journal-title":"J Clin Med"},{"key":"2026022702514629800_tqaf277-B22","doi-asserted-by":"crossref","first-page":"O61","DOI":"10.1186\/1532-429X-17-S1-O61","article-title":"3.0T motion-corrected single-shot phase sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) in free-breathing patients compared with conventional segmented breath-held LGE","volume":"17","author":"Lin","year":"2015","journal-title":"J Cardiovasc Magn Reson"},{"key":"2026022702514629800_tqaf277-B23","doi-asserted-by":"crossref","first-page":"93","DOI":"10.12659\/PJR.892628","article-title":"Artifacts in magnetic resonance imaging","volume":"80","author":"Krupa","year":"2015","journal-title":"Pol J Radiol"},{"key":"2026022702514629800_tqaf277-B24","doi-asserted-by":"crossref","first-page":"1452","DOI":"10.1002\/jmri.22824","article-title":"Impact of partial volume effects on visceral adipose tissue quantification using MRI","volume":"34","author":"Zhou","year":"2011","journal-title":"J Magn Reson Imaging"}],"container-title":["British Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/bjr\/advance-article-pdf\/doi\/10.1093\/bjr\/tqaf277\/65372221\/tqaf277.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/99\/1178\/367\/65372221\/tqaf277.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/bjr\/article-pdf\/99\/1178\/367\/65372221\/tqaf277.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T07:52:00Z","timestamp":1772178720000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/bjr\/article\/99\/1178\/367\/8326864"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,18]]},"references-count":24,"journal-issue":{"issue":"1178","published-online":{"date-parts":[[2025,11,18]]},"published-print":{"date-parts":[[2026,2,1]]}},"URL":"https:\/\/doi.org\/10.1093\/bjr\/tqaf277","relation":{},"ISSN":["0007-1285","1748-880X"],"issn-type":[{"value":"0007-1285","type":"print"},{"value":"1748-880X","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,2]]},"published":{"date-parts":[[2025,11,18]]}}}